1.Comparison Trial between I-SCAN-Optical Enhancement and Chromoendoscopy for Evaluating the Horizontal Margins of Gastric Epithelial Neoplasms
Myeongseok KOH ; Jong Yoon LEE ; Song-Hee HAN ; Seong Woo JEON ; Su Jin KIM ; Joo Young CHO ; Seong Hwan KIM ; Jae Young JANG ; Gwang Ho BAIK ; Jin Seok JANG
Gut and Liver 2023;17(2):234-242
Background/Aims:
Endoscopic submucosal dissection is a widely used treatment for gastric epithelial neoplasms. Accurate delineation of the horizontal margins is necessary for the complete resection of gastric epithelial neoplasms. Recently, image-enhanced endoscopy has been used to evaluate horizontal margins of gastric epithelial neoplasms. The aim of this study was to investigate whether I-SCAN-optical enhancement (I-SCAN-OE) is superior to chromoendoscopy in evaluating the horizontal margin of gastric epithelial neoplasms.
Methods:
This was a multicenter, prospective, and randomized trial. The participants were divided into two groups: I-SCAN-OE and chromoendoscopy. For both groups, we first evaluated the horizontal margins of early gastric cancer or high-grade dysplasia using white-light imaging, and then evaluated, the horizontal margins using I-SCAN-OE or chromoendoscopy. We devised a unique scoring method based on the pathological results obtained after endoscopic submucosal dissection to accurately evaluate the horizontal margins of gastric epithelial neoplasms. The delineation scores of both groups were compared, as were the ratios of positiveegative horizontal margins.
Results:
In total, 124 patients were evaluated for gastric epithelial neoplasms, of whom 112 were enrolled in the study. A total of 112 patients participated in the study, and 56 were assigned to each group (1:1). There was no statistically significant difference in the delineation scores between the groups (chromoendoscopy, 7.80±1.94; I-SCAN-OE, 8.23±2.24; p=0.342).
Conclusions
I-SCAN-OE did not show superiority over chromoendoscopy in delineating horizontal margins of gastric epithelial neoplasms.
2.Automated Composition Analysis of Thrombus from Endovascular Treatment in Acute Ischemic Stroke Using Computer Vision
JoonNyung HEO ; Young SEOG ; Hyungwoo LEE ; Il Hyung LEE ; Sungeun KIM ; Jang-Hyun BAEK ; Hyungjong PARK ; Kwon-Duk SEO ; Gyu Sik KIM ; Han-Jin CHO ; Minyoul BAIK ; Joonsang YOO ; Jinkwon KIM ; Jun LEE ; Yoon-Kyung CHANG ; Tae-Jin SONG ; Jung Hwa SEO ; Seong Hwan AHN ; Heow Won LEE ; Il KWON ; Eunjeong PARK ; Young Dae KIM ; Hyo Suk NAM
Journal of Stroke 2022;24(3):433-435
3.Diode Laser—Can It Replace the Electrical Current Used in Endoscopic Submucosal Dissection? (with Video)
Yunho JUNG ; Gwang Ho BAIK ; Weon Jin KO ; Bong Min KO ; Seong Hwan KIM ; Jin Seok JANG ; Jae-Young JANG ; Wan-Sik LEE ; Young Kwan CHO ; Sun Gyo LIM ; Hee Seok MOON ; In Kyung YOO ; Joo Young CHO
Clinical Endoscopy 2021;54(4):555-562
Background/Aims:
A new medical fiber-guided diode laser system (FDLS) is expected to offer high-precision cutting with simultaneous hemostasis. Thus, this study aimed to evaluate the feasibility of using the 1,940-nm FDLS to perform endoscopic submucosal dissection (ESD) in the gastrointestinal tract of an animal model.
Methods:
In this prospective animal pilot study, gastric and colorectal ESD using the FDLS was performed in ex vivo and in vivo porcine models. The completeness of en bloc resection, the procedure time, intraprocedural bleeding, histological injuries to the muscularis propria (MP) layer, and perforation were assessed.
Results:
The en bloc resection and perforation rates in the ex vivo study were 100% (10/10) and 10% (1/10), respectively; those in the in vivo study were 100% (4/4) and 0% for gastric ESD and 100% (4/4) and 25% (1/4) for rectal ESD, respectively. Deep MP layer injuries tended to occur more frequently in the rectal than in the gastric ESD cases, and no intraprocedural bleeding occurred in either group.
Conclusions
The 1,940-nm FDLS was capable of yielding high en bloc resection rates without intraprocedural bleeding during gastric and colorectal ESD in animal models.
4.Diode Laser—Can It Replace the Electrical Current Used in Endoscopic Submucosal Dissection? (with Video)
Yunho JUNG ; Gwang Ho BAIK ; Weon Jin KO ; Bong Min KO ; Seong Hwan KIM ; Jin Seok JANG ; Jae-Young JANG ; Wan-Sik LEE ; Young Kwan CHO ; Sun Gyo LIM ; Hee Seok MOON ; In Kyung YOO ; Joo Young CHO
Clinical Endoscopy 2021;54(4):555-562
Background/Aims:
A new medical fiber-guided diode laser system (FDLS) is expected to offer high-precision cutting with simultaneous hemostasis. Thus, this study aimed to evaluate the feasibility of using the 1,940-nm FDLS to perform endoscopic submucosal dissection (ESD) in the gastrointestinal tract of an animal model.
Methods:
In this prospective animal pilot study, gastric and colorectal ESD using the FDLS was performed in ex vivo and in vivo porcine models. The completeness of en bloc resection, the procedure time, intraprocedural bleeding, histological injuries to the muscularis propria (MP) layer, and perforation were assessed.
Results:
The en bloc resection and perforation rates in the ex vivo study were 100% (10/10) and 10% (1/10), respectively; those in the in vivo study were 100% (4/4) and 0% for gastric ESD and 100% (4/4) and 25% (1/4) for rectal ESD, respectively. Deep MP layer injuries tended to occur more frequently in the rectal than in the gastric ESD cases, and no intraprocedural bleeding occurred in either group.
Conclusions
The 1,940-nm FDLS was capable of yielding high en bloc resection rates without intraprocedural bleeding during gastric and colorectal ESD in animal models.
5.Posterior Correction of Adolescent Idiopathic Scoliosis with High-Density Pedicle Screw-Only Constructs: 5 Years of Follow-Up
Chang Ju HWANG ; Jong Min BAIK ; Jae Hwan CHO ; So Jeong YOON ; Dong Ho LEE ; Choon Sung LEE
Yonsei Medical Journal 2020;61(4):323-330
PURPOSE: This study aimed to analyze radiological outcomes in patients with adolescent idiopathic scoliosis (AIS) who underwent posterior correction with high-density pedicle screw-only constructs. We hypothesized that high-density pedicle screw-only constructs in AIS would provide a high correction rate and would facilitate the maintenance of the correction or obviate the loss thereof.MATERIALS AND METHODS: We retrospectively analyzed radiological outcomes over a minimum follow-up period of 5 years in patients with AIS who underwent posterior correction with high-density pedicle screw-only constructs. A total of 124 consecutive patients were included. Demographic data, including age, sex, operated fusion level, numbers of screw, Lenke curve type, Risser stage, and follow-up period were retrospectively collected from electronic medical records and radiological measurements including serial follow-up.RESULTS: The average number of pedicle screws was 1.96/vertebra. The average curve correction was 48.3% for the proximal thoracic (PT) curve, 83.1% for the main thoracic (MT) curve, and 80.2% for the thoracolumbar/lumbar (TL/L) curve at final follow-up. Use of high-density pedicle screw-only constructs helped achieve excellent correction rates, with no significant loss of correction at final follow-up.CONCLUSION: We obtained excellent correction rates of 48.3% for PT, 83.1% for MT, and 80.2% for TL/L curves using high-density pedicle screw-only constructs in AIS, with no significant loss of correction at final follow-up.
6.Use of Three-dimensional Transesophageal Echocardiography for the Chiari Network
Jeong-Min HONG ; Ah-Reum CHO ; Seung-Hoon BAIK ; Dea-Hwan MOON
Kosin Medical Journal 2020;35(2):151-155
The Chiari network is an embryonic remnant of the sinus venosus valve, which is characterized by a fenestrated, netlike structure in the right atrium and has the potential to be misdiagnosed as another right atrial pathology. Additionally, the Chiari network has been frequently reported to entrap intracardiac devices during surgical procedures. In this case report, we present two patients with a Chiari network confirmed by three-dimensional transesophageal echocardiography, which assisted in preventing device entrapment during intracardiac procedures.
7.Use of Three-dimensional Transesophageal Echocardiography for the Chiari Network
Jeong-Min HONG ; Ah-Reum CHO ; Seung-Hoon BAIK ; Dea-Hwan MOON
Kosin Medical Journal 2020;35(2):151-155
The Chiari network is an embryonic remnant of the sinus venosus valve, which is characterized by a fenestrated, netlike structure in the right atrium and has the potential to be misdiagnosed as another right atrial pathology. Additionally, the Chiari network has been frequently reported to entrap intracardiac devices during surgical procedures. In this case report, we present two patients with a Chiari network confirmed by three-dimensional transesophageal echocardiography, which assisted in preventing device entrapment during intracardiac procedures.
8.Self-Forgiveness Moderates the Effects of Depression on Suicidality
Minjee JUNG ; Yeonsoo PARK ; Seung Yeon BAIK ; Cho Long KIM ; Hyang Sook KIM ; Seung Hwan LEE
Psychiatry Investigation 2019;16(2):121-129
OBJECTIVE:
Not all depressive individuals are suicidal. An increasing body of studies has examined forgiveness, especially self-forgiveness, as a protective factor of suicide based on that suicide is often accompanied by negative self-perceptions. However, less has been studied on how different subtypes of forgiveness (i.e., forgiveness-of-self, forgiveness-of-others and forgiveness-of-situations) could alleviate the effects of depression on suicide. Hence, this study examined forgiveness as a moderator of depression and suicidality.
METHODS:
305 participants, consisted of 87 males and 218 females, were included in the study. The mean age was 41.05 (SD: 14.48; range: 19–80). Depression, anxiety, and forgiveness were measured through self-report questionnaires, and suicidal risk was measured through a structuralized interview. Moderations were examined through hierarchical regression analyses.
RESULTS:
Depression positively correlated with suicidality. Results of the hierarchical regression analysis indicated forgiveness as a moderator of depression on suicidality. Further analysis indicated only forgiveness-of-self as a significant moderator; the effects of forgiveness-of-others and forgiveness-of-situation were not significant.
CONCLUSION
These findings suggest that forgiveness-of-self is essential in reducing of the effects of depression on suicidality. It is suggested that self-acceptance and the promotion of self-forgiveness should be considered as an important factor when developing suicide prevention strategies.
9.Screening Tool for Anxiety Disorders: Development and Validation of the Korean Anxiety Screening Assessment.
Yeseul KIM ; Yeonsoo PARK ; Gyeongcheol CHO ; Kiho PARK ; Shin Hyang KIM ; Seung Yeon BAIK ; Cho Long KIM ; Sooyun JUNG ; Won Hye LEE ; Younyoung CHOI ; Seung Hwan LEE ; Kee Hong CHOI
Psychiatry Investigation 2018;15(11):1053-1063
OBJECTIVE: This study evaluated the psychometric properties of the Korean Anxiety Screening Assessment (K-ANX) developed for screening anxiety disorders. METHODS: Data from 613 participants were analyzed. The K-ANX was evaluated for reliability using Cronbach’s alpha, item-total correlation, and test information curve, and for validity using focus group interviews, factor analysis, correlational analysis, and item characteristics based on item response theory (IRT). The diagnostic sensitivity and specificity of the K-ANX were compared with those of the Beck Anxiety Inventory (BAI) and Generalized Anxiety Disorder 7-item scale (GAD-7). RESULTS: The K-ANX showed excellent internal consistency (α=0.97) and item-total coefficients (0.92–0.97), and a one-factor structure was suggested. All items were highly correlated with the total scores of the BAI, GAD-7, and Penn State Worry Questionnaire. IRT analysis indicated the K-ANX was most informative as a screening tool for anxiety disorders at the range between 0.8 and 1.6 (i.e., top 21.2 to 5.5 percentiles). Higher sensitivity (0.795) and specificity (0.937) for identifying anxiety disorders were observed in the K-ANX compared to the BAI and GAD-7. CONCLUSION: The K-ANX is a reliable and valid measure to screen anxiety disorders in a Korean sample, with greater sensitivity and specificity than current measures of anxiety symptoms.
Anxiety Disorders*
;
Anxiety*
;
Focus Groups
;
Mass Screening*
;
Psychometrics
;
Sensitivity and Specificity
10.Characterization of Specific IgA Response to Antigenic Determinants of Helicobacter pylori Urease Encoded by ureA and ureB in Children.
Min Kyoung SHIN ; Jin Su JUN ; Soon Wook KWON ; Dong Hae LEE ; Jong Hun HA ; Jin Sik PARK ; Dae Hyun SONG ; Myung Hwan JUNG ; Hyung Lyun KANG ; Seung Chul BAIK ; Ji Sook PARK ; Hee Shang YOUN ; Myung Je CHO ; Ji Hyun SEO ; Woo Kon LEE
Journal of Bacteriology and Virology 2018;48(1):14-22
Helicobacter pylori (H. pylori), a causative agent of chronic gastritis and gastric cancer, has several virulent factors for own survival and progression toward gastric diseases in human stomach. Of those, H. pylori produces mainly urease (10~15% total protein weight) that neutralize the gastric acid for survival. Here, we identified the antigenic epitope of urease and then developed an ELISA using the antigen including the epitope of urease. We identified the antigenic epitope of urease that induces IgA antibodies in human using truncated mutants. Eight kinds of serially-truncated mutant of UreA and UreB were prepared and subjected to immunoblot using pooled sera of patients with gastric disorders. UreBEnd protein containing UreB epitope was produced and investigated its diagnostic value via ELISA in children. As a result, mutants having last 24 amino acid residues of UreB carboxyl terminus deleted did not show IgA-reactive band. The clones that contained the downstream of 448(th) amino acid in UreB showed IgA-reactive band. The serodiagnostic value of the UreBEnd recombinant protein including identified epitope was confirmed via IgA ELISA and shown to have 97% sensitivity and 100% specificity. These results demonstrated that carboxyl terminal region of UreB carries an antigenic epitope for IgA response in human. It may be useful for detecting H. pylori infection with improved test accuracy and minimum use of endoscopy.
Antibodies
;
Child*
;
Clone Cells
;
Endoscopy
;
Enzyme-Linked Immunosorbent Assay
;
Epitopes*
;
Gastric Acid
;
Gastritis
;
Helicobacter pylori*
;
Helicobacter*
;
Humans
;
Immunoglobulin A*
;
Sensitivity and Specificity
;
Stomach
;
Stomach Diseases
;
Stomach Neoplasms
;
Urea*
;
Urease*

Result Analysis
Print
Save
E-mail