1.Clinical features and risk factors of left ventricular hypertrophy in children with primary hypertension.
Yang LIU ; Lin SHI ; Yao LIN ; Ya Qi LI ; Yan Yan LIU ; Hong Wei ZHANG
Chinese Journal of Pediatrics 2023;61(11):1031-1037
Objective: To assess the clinical features and relative factors of left ventricular hypertrophy (LVH) in children with primary hypertension. Methods: In this retrospective cohort study, 430 children diagnosed with primary hypertension in Children's Hospital, Capital Institute of Pediatrics from January 2019 to September 2022 were enrolled. Their clinical data was analyzed and LVH was assessed by echocardiography. According to left ventricular geometry, these children were assigned to the LVH group and normal geometry group. General conditions, laboratory indicators and ambulatory blood pressure parameters between two groups were compared by independent sample t-test or Mann-Whitney U test. Spearman correlation coefficient was used to analyze the correlation between LVH and clinical indicators including blood pressure, biochemical and metabolic indicators. The independent risk factors of LVH were analyzed by multivariable logistic regression. The receiver operating characteristic (ROC) curve was used to explore the value of risk factors in the diagnosis of LVH. Results: Among the 430 children with primary hypertension, 342 (79.5%) were males and 88 (20.5%) females. Their age was (12.6±2.3) years, and 123 children (28.6%) of them had LVH. Body mass index (BMI) ((30.0±5.2) vs. (26.2±4.3) kg/m2), ratio of stage 2 hypertension (75.6% (93/123) vs. 59.6% (183/307)), 24-hour systolic blood pressure (24 h SBP)((131±10) vs. (128±10) mmHg,1 mmHg=0.133 kPa), daytime systolic blood pressure (SBP) ((135±11) vs. (131±11) mmHg), nighttime SBP ((128±11) vs. (123±10) mmHg), cholesterol level ((4.0±0.7) vs. (3.9±0.7) mmol/L), serum uric acid level ((447±81) vs. (426±91) μmol/L) and incidence of hyperinsulinemia (69.9% (86/123) vs.59.0% (181/307)) were significantly elevated in the LVH group compared with those in the normal geometry group (all P<0.05). There were more patients with a disease course over 5 years in the LVH group than in the normal geometry group, with a statistically significant difference (χ2=8.90,P=0.031). Spearman correlation analysis showed that BMI, 24 h SBP, daytime SBP, nighttime SBP, triglyceride, uric acid, and serum sodium level were positively correlated with LVMI (r=0.43, 0.20, 0.18, 0.18, 0.18, 0.16, and 0.12, all P<0.05). BMI, hyperinsulinemia, and cholesterol level were positively correlated with relative wall thickness (RWT) (r=0.22, 0.12, and 0.16, all P<0.05). The multivariate logistic regression analysis showed that BMI (OR=1.17, 95%CI 1.10-1.25) and 24 h SBP (OR=1.04, 95%CI 1.01-1.08) were the independent risk factors for LVH (both P<0.05). The area under the receiver operator characteristic curve, combined with BMI and 24 h SBP, was 0.72 (95%CI 0.67-0.77, P<0.05), with a sensitivity and specificity of 71.5% and 64.8%, respectively. Conclusions: BMI and 24 h SBP are the independent risk factors for LVH in children with primary hypertension, and the combination of BMI and 24 h SBP has an acceptable diagnostic value for LVH. Early monitoring of these indexes is necessary to predict preclinical cardiac damage.
Male
;
Female
;
Humans
;
Child
;
Adolescent
;
Hypertension/diagnosis*
;
Hypertrophy, Left Ventricular/etiology*
;
Uric Acid
;
Blood Pressure Monitoring, Ambulatory
;
Retrospective Studies
;
Blood Pressure/physiology*
;
Risk Factors
;
Essential Hypertension
;
Hyperinsulinism
;
Cholesterol
2.Development of Vital Signal Monitoring System Based on Accelerometer.
Jian CEN ; Xingliang JIN ; Sanchao LIU ; Huacheng LUO ; Nong YAN ; Xianliang HE ; Yumei MA ; Hanyuan LUO ; Jie QIN ; Yinbing YANG
Chinese Journal of Medical Instrumentation 2023;47(6):602-607
OBJECTIVE:
Reduce the number of false alarms and measurement time caused by movement interference by the sync waveform of the movement.
METHODS:
Vital signal monitoring system based on motion sensor was developed, which collected and processed the vital signals continuously, optimized the features and results of vital signals and transmitted the vital signal results and alarms to the interface.
RESULTS:
The system was tested in many departments, such as digestive department, cardiology department, internal medicine department, hepatobiliary surgery department and emergency department, and the total collection time was 1 940 h. The number of false electrocardiograph (ECG) alarms decreased by 82.8%, and the proportion of correct alarms increased by 28%. The average measurement time of non-invasive blood pressure (NIBP) decreased by 16.1 s. The total number of false respiratory rate measurement decreased by 71.9%.
CONCLUSIONS
False alarms and measurement failures can be avoided by the vital signal monitoring system based on accelerometer to reduce the alarm fatigue in clinic.
Humans
;
Monitoring, Physiologic
;
Electrocardiography
;
Arrhythmias, Cardiac
;
Blood Pressure
;
Accelerometry
;
Clinical Alarms
3.Effect of Home Blood Pressure Telemonitoring Plus Additional Support on Blood Pressure Control: A Randomized Clinical Trial.
Wen Wen MENG ; Yong Yi BAI ; Li YAN ; Wei ZHENG ; Qiang ZENG ; Yan Song ZHENG ; Lin ZHA ; Hong Ying PI ; Xiao Yong SAI
Biomedical and Environmental Sciences 2023;36(6):517-526
OBJECTIVE:
Current clinical evidence on the effects of home blood pressure telemonitoring (HBPT) on improving blood pressure control comes entirely from developed countries. Thus, we performed this randomized controlled trial to evaluate whether HBPT plus support (patient education and clinician remote hypertension management) improves blood pressure control more than usual care (UC) in the Chinese population.
METHODS:
This single-center, randomized controlled study was conducted in Beijing, China. Patients aged 30-75 years were eligible for enrolment if they had blood pressure [systolic (SBP) ≥ 140 mmHg and/or diastolic (DBP) ≥ 90 mmHg; or SBP ≥ 130 mmHg and/or DBP ≥ 80 mmHg with diabetes]. We recruited 190 patients randomized to either the HBPT or the UC groups for 12 weeks. The primary endpoints were blood pressure reduction and the proportion of patients achieving the target blood pressure.
RESULTS:
Totally, 172 patients completed the study, the HBPT plus support group ( n = 84), and the UC group ( n = 88). Patients in the plus support group showed a greater reduction in mean ambulatory blood pressure than those in the UC group. The plus support group had a significantly higher proportion of patients who achieved the target blood pressure and maintained a dipper blood pressure pattern at the 12th week of follow-up. Additionally, the patients in the plus support group showed lower blood pressure variability and higher drug adherence than those in the UC group.
CONCLUSION
HBPT plus additional support results in greater blood pressure reduction, better blood pressure control, a higher proportion of dipper blood pressure patterns, lower blood pressure variability, and higher drug adherence than UC. The development of telemedicine may be the cornerstone of hypertension management in primary care.
Humans
;
Blood Pressure
;
Blood Pressure Monitoring, Ambulatory
;
Hypertension/therapy*
;
Telemedicine/methods*
;
Hypotension
4.Blood Pressure Variability May Be a New Predictor for the Occurrence and Prognosis of Ischemic Stroke.
Ke-Qiong YAN ; Qi-Si WU ; Jun YANG
Chinese Medical Sciences Journal 2023;38(3):242-249
Despite declines in morbidity and mortality in recent years, ischemic stroke (IS) remains one of the leading causes of death and disability from cerebrovascular diseases. Addressing the controllable risk factors underpins the successful clinical management of IS. Hypertension is one of the most common treatable risk factors for IS and is associated with poor outcomes. Ambulatory blood pressure monitoring has revealed that patients with hypertension have a higher incidence of blood pressure variability (BPV) than those without hypertension. Meanwhile, increased BPV has been identified as a risk factor for IS. The risk of IS is higher and the prognosis after infarction is worse with higher BPV, no matter in the acute or subacute phase. BPV is multifactorial, with alterations reflecting individual physiological and pathological changes. This article reviews the current research advances in the relationship between BPV and IS, with an attempt to raise awareness of BPV among clinicians and IS patients, explore the increased BPV as a controllable risk factor for IS, and encourage hypertensive patients to control not only average blood pressure but also BPV and implement personalized blood pressure management.
Humans
;
Blood Pressure/physiology*
;
Ischemic Stroke/complications*
;
Blood Pressure Monitoring, Ambulatory
;
Hypertension
;
Stroke/complications*
;
Prognosis
5.A study to identify obstructive sleep apnea syndrome based on 24 h ambulatory blood pressure data.
Jian ZHANG ; Jiaojie REN ; Shuchen SUN ; Zhengbo ZHANG
Journal of Biomedical Engineering 2022;39(1):1-9
Sleep apnea causes cardiac arrest, sleep rhythm disorders, nocturnal hypoxia and abnormal blood pressure fluctuations in patients, which eventually lead to nocturnal target organ damage in hypertensive patients. The incidence of obstructive sleep apnea hypopnea syndrome (OSAHS) is extremely high, which seriously affects the physical and mental health of patients. This study attempts to extract features associated with OSAHS from 24-hour ambulatory blood pressure data and identify OSAHS by machine learning models for the differential diagnosis of this disease. The study data were obtained from ambulatory blood pressure examination data of 339 patients collected in outpatient clinics of the Chinese PLA General Hospital from December 2018 to December 2019, including 115 patients with OSAHS diagnosed by polysomnography (PSG) and 224 patients with non-OSAHS. Based on the characteristics of clinical changes of blood pressure in OSAHS patients, feature extraction rules were defined and algorithms were developed to extract features, while logistic regression and lightGBM models were then used to classify and predict the disease. The results showed that the identification accuracy of the lightGBM model trained in this study was 80.0%, precision was 82.9%, recall was 72.5%, and the area under the working characteristic curve (AUC) of the subjects was 0.906. The defined ambulatory blood pressure features could be effectively used for identifying OSAHS. This study provides a new idea and method for OSAHS screening.
Blood Pressure
;
Blood Pressure Monitoring, Ambulatory
;
Humans
;
Hypertension/complications*
;
Polysomnography
;
Sleep Apnea, Obstructive/diagnosis*
6.Status of home blood pressure monitoring and influencing factors of regular home blood pressure monitoring among elderly uncontrolled hypertensive patients in Central and Western China.
Jia Ying LI ; Ting Xuan YANG ; Run Qing JI ; Wei LI ; Xue Ke BAI ; Jing LI ; Jia Min LIU
Chinese Journal of Cardiology 2022;50(10):1007-1013
Objective: To describe the prevalence of home blood pressure monitoring and analyze the factors influencing regular blood pressure monitoring among elderly uncontrolled hypertensive patients in Central and Western China. Methods: It was a cross-sectional study, which enrolled hypertensive patients aged over 60 years with office blood pressure ≥140/90 mmHg (1 mmHg=0.133 kPa) from September 2019 to July 2020 in 72 hospitals in Central and Western China. Patients completed the electronic questionnaires, and were divided into regular and irregular home blood pressure monitoring groups. The proportion of patients using different types of sphygmomanometers and the percentage of patients with regular home blood pressure monitoring (at least weekly) were explored. The generalized linear mixed model was used to define the influencing factors of regular home blood pressure monitoring. Results: A total of 3 857 patients were included in this study. Age was 67(64,71) years old and there were 2 163 males (56.1%). Overall, sphygmomanometer was available at home for 3 044(78.9%) patients, 2 168(56.2%) patients conducted regular home blood pressure monitoring. Among the patients with a sphygmomanometer at home, 2 370(77.9%) of the sphygmomanometers were upper arm electronic device. Older age, higher income, longer history of hypertension, multiple antihypertensive medications and awareness of diagnostic criteria of hypertension and hypertension complications were associated with a higher prevalence of regular home blood pressure monitoring (all P<0.05). Conclusions: Among the elderly hypertensive patients with uncontrolled blood pressure in Central and Western China, there is a relatively high prevalence of home sphygmomanometer ownership and regular monitoring. Age, family income, history of hypertension, number of antihypertensive drugs and knowledge of hypertension are the influencing factors of regular home blood pressure monitoring in this population.
Aged
;
Male
;
Humans
;
Middle Aged
;
Blood Pressure Monitoring, Ambulatory
;
Antihypertensive Agents/therapeutic use*
;
Cross-Sectional Studies
;
Hypertension/drug therapy*
;
Blood Pressure
;
China/epidemiology*
7.Effect of electrode temperature on measurements of transcutaneous carbon dioxide partial pressure and oxygen partial pressure in very low birth weight infants.
Bing-Hui LI ; Chang-Liang ZHAO ; Shun-Li CAO ; Hong-Li GENG ; Jing-Jing LI ; Min ZHU ; Shi-Ping NIU
Chinese Journal of Contemporary Pediatrics 2021;23(8):809-813
OBJECTIVES:
To evaluate the accuracy and safety of measurements of transcutaneous carbon dioxide partial pressure (TcPCO
METHODS:
A total of 45 very low birth weight infants were enrolled. TcPCO
RESULTS:
There was no significant difference in TcPCO
CONCLUSIONS
Lower electrode temperatures (38-41℃) can accurately measure blood carbon dioxide partial pressure in very low birth weight infants, and thus can be used to replace the electrode temperature of 42°C. Transcutaneous measurements at the lower electrode temperatures may be helpful for understanding the changing trend of blood oxygen partial pressure.
Blood Gas Monitoring, Transcutaneous
;
Carbon Dioxide
;
Electrodes
;
Humans
;
Infant
;
Infant, Newborn
;
Infant, Very Low Birth Weight
;
Oxygen
;
Partial Pressure
;
Temperature
8.Association between glycated hemoglobin and ambulatory blood pressure or heart rate in hypertensive patients.
Yuan LI ; Bin DENG ; Yuxuan GUO ; Qingling PENG ; Tao HU ; Ke XIA
Journal of Central South University(Medical Sciences) 2021;46(5):488-496
OBJECTIVES:
To determine the association between glycosylated hemoglobin (HbA1c) and ambulatory blood pressure or heart rate in hypertensive patients.
METHODS:
A total of 585 patients, who performed ambulatory blood pressure monitoring (ABPM) from September 2018 to April 2019 in Xiangya Hospital, Central South University, were enrolled and assigned into 2 groups (470 in a hypertensive group and 115 in a normal group). HbA1c levels were compared. According to the HbA1c level, the hypertensive group was divided into 2 subgroups: A high HbA1c group (HbA1c≥6.1%,
RESULTS:
The hypertensive group had higher HbA1c level than the normal group [(6.1±1.3)% vs (5.1±1.7)%,
CONCLUSIONS
In hypertensive patients, HbA1c is positively correlated with ambulate blood pressure, blood pressure load, and heart rate, and it has no correlation with blood pressure variability, heart rate variability, or morning blood pressure.
Blood Pressure
;
Blood Pressure Monitoring, Ambulatory
;
Glycated Hemoglobin A/analysis*
;
Heart Rate
;
Humans
;
Hypertension
9.Effects of SGLT2i on 24-hour ambulatory blood pressure in patients with type 2 diabetes complicating hypertension: a meta-analysis.
Li TIAN ; Qiong Ying WANG ; Run Min SUN ; Miao Miao QI ; Ya Xin LI ; Xin GAO ; Li Qiong ZHANG ; Xue MA ; Hang SHI ; Jing YU ; Feng BAI
Chinese Journal of Cardiology 2021;49(10):1000-1011
Objective: To analyze the effects of different types of sodium-glucose cotransporter 2 inhibitors (SGLT2i) on 24-hour ambulatory blood pressure in patients with type 2 diabetes mellitus and hypertension. Method: In this meta-analysis, we searched for randomized controlled trials on the effect of SGLT2i on 24-hour ambulatory blood pressure in patients with type 2 diabetes and hypertension. Three databases, namely PubMed, Web of Science and Cochrane Library, were searched. The search was organized on the concept of 3 conceptual groups: the first group contained terms used to describe SGLT2i, the second group contained terms related to blood pressure, and the third group contained terms used to describe randomized controlled trials. The search time was from the establishment of the database to December 2020. The inclusion and exclusion criteria were formulated in accordance with the requirements of the Cochrane systematic review. According to whether the heterogeneity of the study was significant or not, a random effect model or a fixed effect model were used to conduct the analysis on the impact of different types of SGLT2i on 24-hour ambulatory blood pressure and day and night blood pressure in patients with type 2 diabetes and hypertension. Further subgroup analysis was performed to define potential factors, which might lead to clinical heterogeneity. Results: Seven clinical trials were finally included. The result of the meta-analysis showed that compared with placebo group, SGLT2i could reduce the 24-hour dynamic systolic blood pressure of patients with type 2 diabetes and hypertension by 4.36 mmHg (1 mmHg=0.133 kPa). Reduction was 4.59, 3.74, 5.06, and 3.64 mmHg by canagliflozin, dapagliflozin, empagliflozin, and ertugliflozin respectively; SGLT2i could reduce the 24-hour dynamic diastolic blood pressure of patients with type 2 diabetes and hypertension by 2.20 mmHg, and the reduction was 2.30, 1.22, 2.00, and 2.69 mmHg by canagliflozin, dapagliflozin, empagliflozin and ertugliflozin respectively. SGLT2i could reduce the daytime systolic blood pressure of patients with type 2 diabetes and hypertension by 5.25 mmHg, and reduction was 5.38, 4.87, 6.00, and 4.37 mmHg by canagliflozin, dapagliflozin, empagliflozin and ertugliflozin, respectively. Simultaneously, SGLT2i could reduce the diastolic blood pressure of patients with type 2 diabetes and hypertension by 2.62 mmHg, and the reduction was 2.56, 2.47, and 2.80 mmHg by canagliflozin, empagliflozin and ertugliflozin, respectively. SGLT2i could reduce the nighttime systolic blood pressure of patients with type 2 diabetes and hypertension by 3.62 mmHg, and the reduction was 2.09, 2.06, 3.92, and 2.45 mmHg by canagliflozin, dapagliflozin, empagliflozin and ertugliflozin, respectively. At the same time, SGLT2i could reduce the nighttime diastolic blood pressure of patients with type 2 diabetes and hypertension by 1.60 and 1.51 mmHg, the reduction was 1.53 and 2.58 mmHg by canagliflozin, empagliflozin and ertugliflozin, respectively. Conclusion: SGLT2i can reduce 24-hour ambulatory blood pressure in patients with type 2 diabetes and hypertension.
Blood Pressure
;
Blood Pressure Monitoring, Ambulatory
;
Diabetes Mellitus, Type 2/drug therapy*
;
Humans
;
Hypertension/drug therapy*
;
Sodium-Glucose Transporter 2 Inhibitors/therapeutic use*
10.Comparison of pulse pressure variation, stroke volume variation, and plethysmographic variability index in pediatric patients undergoing craniotomy.
Ya Fei LIU ; Lin Lin SONG ; Mao Wei XING ; Li Xin CAI ; Dong Xin WANG
Journal of Peking University(Health Sciences) 2021;53(5):946-951
OBJECTIVE:
To compare well-known preload dynamic parameters intraoperatively including stroke volume variation (SVV), pulse pressure variation (PPV), and plethysmographic variability index (PVI) in children who underwent craniotomy for epileptogenic lesion excision.
METHODS:
A total of 30 children aged 0 to 14 years undergoing craniotomy for intracranial epileptogenic lesion excision were enrolled. During surgery, we measured PPV, SVV (measured by the Flotrac/Vigileo device), and PVI (measured by the Masimo Radical-7 monitor) simultaneously and continuously. Preload dynamic parameter measurements were collected at predefined steps: after induction of anesthesia, during opening the skull, intraoperative electroencephalogram monitoring, excision of epileptogenic lesion, skull closure, at the end of the operation. After exclusion of outliers, agreement among SVV, PPV, and PVI was assessed using repeated measures of Bland-Altman approach. The 4-quadrant and polar plot techniques were used to assess the trending ability among the changes in the three parameters.
RESULTS:
The mean SVV, PPV, and PVI were 8%±2%, 10%±3%, and 15%±7%, respectively during surgery. We analyzed a total of 834 paired measurements (3 to 8 data sets for each phase per patient). Repeated measures Bland-Altman analysis identified a bias of -2.3 and 95% confidence intervals between -1.9 and -2.7 (95% limits of agreement between -6.0 and 1.5) between PPV and SVV, showing significant correlation at all periods. The bias between PPV and PVI was -5.0 with 95% limits of agreement between -20.5 and 10.5, and that between SVV and PVI was -7.5 with 95% limits of agreement between -22.7 and 7.8, both not showing significant correlation. Reflected by 4-quadrant plots, the con-cordance rates showing the trending ability between the changes in PPV and SVV, PPV and PVI, SVV and PVI were 88.6%, 50.4%, and 50.1%, respectively. The concordance rate between PPV and SVV was higher (92.7%) in children aged less than 3 years compared with those aged 3 and more than 3 years. The mean angular bias, radial limits of agreement, and angular concordance rate in the polar analysis were not clinically acceptable in the changes between arterial pressure waveform-based parameters and volume-based PVI (PPV vs. PVI: angular mean bias 8.4°, angular concordance rate 29.9%; SVV vs. PVI: angular mean bias 2.4°, angular concordance rate 29.1%). There was a high concordance between the two arterial pressure waveform-based parameters reflected by the polar plot (angular mean bias -0.22°, angular concordance rate 86.6%).
CONCLUSION
PPV can be viewed as a surrogate for SVV, especially in children aged less than 3 years. The agreement between arterial pressure waveform-based preload parameters (PPV and SVV) and PVI is poor and these two should not be considered interchangeable. Attempt to combine PVI and PPV for improving the anesthesiologist's ability to monitor cardiac preload in major pediatric surgery is warranted.
Arterial Pressure
;
Blood Pressure
;
Child
;
Craniotomy
;
Humans
;
Monitoring, Intraoperative
;
Stroke Volume

Result Analysis
Print
Save
E-mail