1.Feasibility study of using bridging temporary permanent pacemaker in patients with high-degree atrioventricular block after TAVR.
San Shuai CHANG ; Xin Min LIU ; Zhi Nan LU ; Jing YAO ; Cneng Qian YIN ; Wen Hui WU ; Fei YUAN ; Tai Yang LUO ; Zheng Ming JIANG ; Guang Yuan SONG
Chinese Journal of Cardiology 2023;51(6):648-655
Objective: To determine the feasibility of using temporary permanent pacemaker (TPPM) in patients with high-degree atrioventricular block (AVB) after transcatheter aortic valve replacement (TAVR) as bridging strategy to reduce avoidable permanent pacemaker implantation. Methods: This is a prospective observational study. Consecutive patients undergoing TAVR at Beijing Anzhen Hospital and the First Affiliated Hospital of Zhengzhou University from August 2021 to February 2022 were screened. Patients with high-degree AVB and TPPM were included. Patients were followed up for 4 weeks with pacemaker interrogation at every week. The endpoint was the success rate of TPPM removal and free from permanent pacemaker at 1 month after TPPM. The criteria of removing TPPM was no indication of permanent pacing and no pacing signal in 12 lead electrocardiogram (EGG) and 24 hours dynamic EGG, meanwhile the last pacemaker interrogation indicated that ventricular pacing rate was 0. Routinely follow-up ECG was extended to 6 months after removal of TPPM. Results: Ten patients met the inclusion criteria for TPPM, aged (77.0±11.1) years, wirh 7 females. There were 7 patients with third-degree AVB, 1 patient with second-degree AVB, 2 patients with first degree AVB with PR interval>240 ms and LBBB with QRS duration>150 ms. TPPM were applied on the 10 patients for (35±7) days. Among 8 patients with high-degree AVB, 3 recovered to sinus rhythm, and 3 recovered to sinus rhythm with bundle branch block. The other 2 patients with persistent third-degree AVB received permanent pacemaker implantation. For the 2 patients with first-degree AVB and LBBB, PR interval shortened to within 200 ms. TPPM was successfully removed in 8 patients (8/10) at 1 month without permanent pacemaker implantation, of which 2 patients recovered within 24 hours after TAVR and 6 patients recovered 24 hours later after TAVR. No aggravation of conduction block or permanent pacemaker indication were observed in 8 patients during follow-up at 6 months. No procedure-related adverse events occurred in all patients. Conclusion: TPPM is reliable and safe to provide certain buffer time to distinguish whether a permanent pacemaker is necessary in patients with high-degree conduction block after TAVR.
Female
;
Humans
;
Atrioventricular Block/therapy*
;
Feasibility Studies
;
Transcatheter Aortic Valve Replacement
;
Pacemaker, Artificial
;
Bundle-Branch Block
4.The success rate of His-Purkinje system pacing in patients with various sites of atrioventricular block.
Yang GAO ; Miao Miao LI ; Hai Bo YU ; Guo Qing XU ; Bai Ge XU ; Min WU ; Na WANG ; Yan Chun LIANG ; Zu Lu WANG ; Ya Ling HAN
Chinese Journal of Cardiology 2022;50(6):543-548
Objective: To evaluate the success rate of His-Purkinje system pacing (HPSP) in patients with various sites of atrioventricular block (AVB) and provide clinical evidence for the selection of HPSP in patients with AVB. Methods: This is a retrospective case analysis. 637 patients with AVB who underwent permanent cardiac pacemaker implantation and requiring high proportion of ventricular pacing from March 2016 to September 2021 in the Department of Cardiology, General Hospital of Northern Theater Command were enrolled. The site of AVB was determined by electrophysiological examination. His bundle pacing (HBP) was performed in the first 130 patients (20.4%) who were classified as the HBP group and HPSP included HBP and/or left bundle branch pacing (LBBP) was performed in later 507 patients (79.6%) and these patients were classified as the HPSP group. The basic clinical information such as age and sex of the two groups was compared, and the success rates of HBP or HPSP in patients with different sites of AVB and QRS intervals were analyzed. Results: The age of HBP group was (66.4±15.9) years with 75 males (57.7%). The age of HPSP group was (66.8±13.6) years with 288 (56.8%) males. Among 637 patients, 63.0% (401/637) had atrioventricular node block; 22.9% (146/637) had intra-His block; 14.1% (90/637) had distal or inferior His bundle block. Totally, the success rate of HPSP was higher than that of HBP [93.9% (476/507) vs. 86.9% (113/130), P<0.05]. In each group of patients with various AVB sites, the success rate of HPSP was higher than that of HBP respectively and both success rates of HBP and HPSP showed a declining trend with the distant AVB site. The success rate of HBP in patients with atrioventricular node block and intra-His block was higher than that in patients with distal or inferior His bundle block [95.2% (79/83) vs. 47.1% (8/17), P<0.001; 86.7% (26/30) vs. 47.1% (8/17), P=0.010]. The success rate of HPSP was higher than that of HBP in patients with distal or inferior His bundle block [87.7% (64/73) vs 47.1% (8/17), P=0.001]. In patients with QRS<120 ms, 94.9% (520/548) of AVB sites were in atrioventricular node or intra-His, and HBP had a similar high success rate with HPSP [95.6% (109/114) vs. 96.3% (418/434), P=0.943] in these patients. In patients with QRS ≥ 120 ms, 69.7% (62/89) of AVB sites were at distal or inferior His bundle, and the success rate of HBP was only 25.0% (4/16), while the success rate of HPSP was as high as 79.5% (58/73), P<0.001. Conclusions: In patients with QRS<120 ms and atrioventricular node block or intra-His block, success rates of HBP and HPSP are similarly high and HBP might be considered as the first choice. In patients with QRS ≥ 120 ms and AVB site at distal or inferior His bundle, the success rate of HPSP is higher than that of HBP, suggesting LBBP should be considered as the first-line treatment option.
Aged
;
Aged, 80 and over
;
Atrioventricular Block/therapy*
;
Bundle of His/physiology*
;
Cardiac Pacing, Artificial
;
Electrocardiography
;
Female
;
Humans
;
Male
;
Middle Aged
;
Retrospective Studies
;
Treatment Outcome
5.Usefulness of an Implantable Loop Recorder in Diagnosing Unexplained Syncope and Predictors for Pacemaker Implantation
Sung Ho LEE ; Tae Hoon KIM ; Yong Seog OH ; Seil OH ; Jong Il CHOI ; Jin Bae KIM ; Jong Chun NAH ; Sung Il IM ; Ki Woon KANG ; Seongwook HAN ; June Soo KIM
Journal of Korean Medical Science 2020;35(2):11-
atrioventricular block in 2 (5.9%). Overall, ILR detected significant arrhythmia in 99 patients (57.2%) irrespective of syncope. Among patients with clinically relevant arrhythmia detected by ILR, PM implantation was performed in 60 (34.7%), an intra-cardiac defibrillator in 5 (2.9%), and catheter ablation in 4 (2.3%). In a Cox regression analysis, history of paroxysmal atrial fibrillation (PAF) (hazard ratio [HR], 2.34; 95% confidence interval [CI], 1.33–4.12; P < 0.01) and any bundle branch block (BBB) (HR, 2.52; 95% CI, 1.09–5.85; P = 0.03) were significantly associated with PM implantation.CONCLUSION: ILR is useful for detecting syncope-correlated arrhythmia in patients with US. The risk of PM is high in US patients with a history of PAF and any BBB.]]>
Arrhythmias, Cardiac
;
Atrial Fibrillation
;
Atrioventricular Block
;
Bundle-Branch Block
;
Catheter Ablation
;
Defibrillators
;
Follow-Up Studies
;
Humans
;
Korea
;
Male
;
Observational Study
;
Retrospective Studies
;
Sick Sinus Syndrome
;
Syncope
;
Tachycardia
6.Sevoflurane with opioid or dexmedetomidine infusions in dogs undergoing intracranial surgery: a retrospective observational study
Felipe MARQUEZ-GRADOS ; Enzo VETTORATO ; Federico CORLETTO
Journal of Veterinary Science 2020;21(1):8-
atrioventricular block, postoperative presence of agitation, seizures, use of labetalol and dexmedetomidine infusion were also recorded. Data from the two groups were compared with Fisher's exact test and unpaired t tests with Welch's correction. Odds ratio (OR) and 95% confidence interval (CI) were calculated for categorical variables. Intra-operatively, MAP was lower in Sevo-Op [85 (± 6.54) vs. 97.69 (± 7.8) mmHg, p = 0.0009]. Time to extubation was longer in Sevo-Dex [37.69 (10–70) vs. 19.63 (10–25), p = 0.0033]. No differences were found for the other intra-operative and post-operative variables investigated. Post-operative hypertension and agitation were the most common complications (11 and 12 out of 21 animals, respectively). These results suggest that the infusion of dexmedetomidine provides similar intra-operative conditions and post-operative course to a short acting opioid infusion during sevoflurane anesthesia in dogs undergoing elective rostrotentorial or transfrontal intracranial surgery.]]>
Airway Extubation
;
Anesthesia
;
Animals
;
Arterial Pressure
;
Atrioventricular Block
;
Bradycardia
;
Brain Neoplasms
;
Carbon Dioxide
;
Dexmedetomidine
;
Dihydroergotamine
;
Dogs
;
Fever
;
Heart Rate
;
Hypertension
;
Hypotension
;
Hypothermia
;
Labetalol
;
Neurosurgery
;
Observational Study
;
Odds Ratio
;
Retrospective Studies
;
Seizures
;
Tachycardia
7.Feasibility and safety of new simplified left bundle branch area pacing via nine-partition method.
Jun Meng ZHANG ; Yu Xiao ZHANG ; Jie Ruo CHEN ; Ze Feng WANG ; Lin Na ZU ; Li Ting CHENG ; Zi Yu WANG ; Xin Lu WANG ; Fei HANG ; Yong Quan WU
Chinese Journal of Cardiology 2020;48(10):848-852
Objective: To investigate the efficacy and safety of left bundle branch area pacing (LBBaP) with the new simplified approach (nine-partition method). Methods: A total of 118 patients with clinical indications and received pacemaker implantation from December 1, 2018 to December 31, 2019 in Beijing Anzhen Hospital were enrolled. LBBaP was performed with the nine-partition method (in the right anterior oblique 30° position, the ventriculogram was divided into nine partitions and the initial implant sites were located in the lower base 1/3 partitions). In X-ray image, the 3830 lead is located in the left bundle branch area, the unipolar pacing QRS wave is in the form of right bundle branch block, and the peak time from stimulation to left ventricular activation<90 ms is defined as successful operation. The clinical characters, such as the methods of venipuncture, electrode parameters, operation duration, fluoroscopy duration, the peak time from stimulation to left ventricular, pacemaker types, surgical success rate, complications, and immediate postoperative ECG parameters were collected. The patients were followed up after the operation, and the electrode parameters and postoperative complications were recorded. Results: This study is a retrospective study. There were 62 (52.5%) male patients in this cohort, the average age was (65.9±13.4) years old,and there were 49(41.5%) sick sinus syndrome, 6(5.1%) abnormal sinus node and atrioventricular node simultaneously, 63(53.4%) atrioventricular block, 26(22.0%) atrial fibrillation, 20(16.9%) cardiomyopathy; the baseline duration of QRS was (109.21±39.03) ms. Successful LBBaP was achieved in 109 patients with"nine-partition method"and the success rate was 92.4%; 104 patients (95.5%) were axillary vein puncture, 5 (4.6%) were subclavian vein puncture; the operation duration was (80.3±23.0) min, the fluoroscopy duration was (12.29±5.13) min; the QRS duration after LBBaP was (116.36±18.11) ms. The threshold of the left bundle branch (LBB) lead was (0.92±0.63) V, the R wave amplitude was (10.60±5.04) mV and the impedance was (798.71±194.90) Ω. In 1 V pacing, the peak time from stimulation to left ventricular activation was (67.91±12.15) ms, and in 5 V pacing was (67.52±12.45) ms; 1 case (0.9%) with a single-chamber pacemaker implanted, 106 cases (97.3%) with dual-chamber pacemaker and 2 cases (1.8%) with three-chamber pacemakers. There were no hematomas, pneumothorax, hemothorax, electrode dislocation, infection, and capsular hemorrhage and other serious surgery-related complications during the operation. A total of 97 patients (89.0%) were followed up for (6.21±2.90) months. The electrode parameters of all patients were stable and no complications observed. Conclusions: The LBBaP with nine-partition method is a simple, safe and effective physiological pacing approach. However, its long-term effect still needs to be further verified.
Aged
;
Atrioventricular Block
;
Bundle-Branch Block/therapy*
;
Cardiac Pacing, Artificial
;
Feasibility Studies
;
Humans
;
Male
;
Middle Aged
;
Retrospective Studies
8.Management of Arrhythmias Associated with Cardiac Sarcoidosis
Korean Circulation Journal 2019;49(2):119-133
Sarcoidosis is a multisystem granulomatous disorder of unknown etiology. The annual incidence of systemic sarcoidosis is estimated at 10–20 per 100,000 individuals. Owing to the recent advances in imaging modalities, cardiac sarcoidosis (CS) is diagnosed more frequently. The triad of CS includes conduction abnormality, ventricular tachycardia, and heart failure. Atrial and ventricular arrhythmias are caused by either inflammation or scar formation. Inflammation should be treated with immunosuppression and antiarrhythmic agents and scar formation should be treated with antiarrhythmics and/or ablation, in addition to implantable cardioverter defibrillator (ICD) implantation, if necessary. Ablation can provide a good outcome, but it might require bipolar ablation if the critical portion is located mid-myocardium. Late recurrence might be caused by reactivation of sarcoidosis, which would need to be evaluated by positron emission tomography-computed tomography imaging. Risk of sudden cardiac death (SCD) in patients with advanced atrioventricular block is not low, and ICD implantation could be considered instead of a pacemaker. For risk stratification for SCD, late gadolinium enhancement by cardiac magnetic resonance imaging or program stimulation is often used.
Arrhythmias, Cardiac
;
Atrioventricular Block
;
Catheter Ablation
;
Cicatrix
;
Death, Sudden, Cardiac
;
Defibrillators
;
Defibrillators, Implantable
;
Electrons
;
Gadolinium
;
Heart Failure
;
Humans
;
Immunosuppression
;
Incidence
;
Inflammation
;
Magnetic Resonance Imaging
;
Recurrence
;
Sarcoidosis
;
Tachycardia, Ventricular
9.A Case of an Infant Diagnosed with Cow's Milk Allergy and Concurrent Meat Allergy via ImmunoCAP ISAC®
So Yoon JO ; Chan Ho LEE ; Sung Won KIM ; Yoon Ha HWANG
Kosin Medical Journal 2019;34(1):72-77
Approximately 13–20% of infants with milk allergies concurrently exhibit beef allergies. Here, we report a 24-month-old infant who exhibited both pork and beef allergies, concurrently with a milk allergy. The infant's laboratory test results were: 3.73 ISU-E (ISAC standardized unit for IgE) for cow milk β-lactoglobulin, 23.8 ISU-E for casein, 12.8 ISU-E for cow milk Bos d 6 of serum albumin, and 4.85 ISU-E for cat Fel d 2. This case report summarizes an infant patient diagnosed with a meat allergy that was associated with cow's milk allergy, using ImmunoCAP ISAC®. Not only ImmunoCAP ISAC® but also immunocap can be used to diagnose milk allergy and meat allergy at the same time, immunocap testing for component antigen is rare. ImmunoCAP ISAC® is used to diagnose these allergies in our case study, as it has advantage that only 1ml of blood is needed to run various component antigen tests.
Anesthesia, General
;
Animals
;
Atrioventricular Block
;
Bradycardia
;
Caseins
;
Cats
;
Child, Preschool
;
Humans
;
Hypersensitivity
;
Infant
;
Meat
;
Milk Hypersensitivity
;
Milk
;
Red Meat
;
Serum Albumin
10.Persistent Complete Atrioventricular Block after Induction of General Anesthesia in a Healthy Patient
Gyeong Jo BYEON ; Hye Jin KIM ; Hyun Su RI ; Su Sung LEE ; Hee Young KIM
Kosin Medical Journal 2019;34(1):65-71
A 38-year-old female patient had bradycardia in the preoperative electrocardiogram (ECG), and she showed severe bradycardia, with the heart rate (HR) under 40 beats per minute (bpm) even after arrival in the operating room. Immediately after endotracheal intubation, ventricular tachycardia with HR over 200 bpm occurred, but it disappeared voluntarily. The surgery was postponed for additional cardiac evaluation because of the persistent severe bradycardia. On postanesthesia day 2, complete atrioventricular (AV) block appeared. We expected spontaneous recovery over 2 weeks, but the complete AV block persisted. A permanent pacemaker was eventually inserted, and the patient was discharged without other complications on day 4 after insertion of the pacemaker. We report this case because complete AV block has commonly occurred in patients with risk factors such as first AV block, secondary AV block, or bundle branch block, but complete AV block has occurred despite the absence of arrhythmia in this patient.
Adult
;
Anesthesia, General
;
Arrhythmias, Cardiac
;
Atrioventricular Block
;
Bradycardia
;
Bundle-Branch Block
;
Electrocardiography
;
Female
;
Heart Rate
;
Humans
;
Intubation, Intratracheal
;
Operating Rooms
;
Risk Factors
;
Tachycardia, Ventricular

Result Analysis
Print
Save
E-mail