1.Effect of autologous blood transfusion device on preventing blood loss in primary total knee arthroplasty using comprehensive hemostatic methods.
Yang LI ; Bang Guo LI ; Ran ZHAO ; Hua TIAN ; Ke ZHANG
Journal of Peking University(Health Sciences) 2018;50(4):651-656
OBJECTIVE:
To analyze the conventional application of using comprehensive hemostatic methods during the perioperative period, and the effect of autologous blood transfusion (ABT) device compared with non-negative pressure drainage on preventing blood loss and allogenic blood transfusion after primary total knee arthroplasty (TKA).
METHODS:
A total of 131 patients (131 knees) with severe knee osteoarthritis who underwent unilateral primary TKA by the same surgeon in Peking University Third Hospital from June 2014 to June 2015 were enrolled in this study. The patients were divided into ABT group (64 patients) and control group (67 patients). ABT devices were used for drainage and blood transfusion in the ABT group while the control group used the non-negative pressure drainage only. The results of the drainage fluid volume, the decrease of hemoglobin, the total blood loss, the hidden blood loss and blood transfusion after TKA were compared between the two groups.
RESULTS:
The drainage fluid volume in ABT group was significantly higher than that in control group [515 mL (80-1 610 mL) vs. 260 mL (40-670 mL), P<0.001]. The autologous blood transfusion in ABT group was 245 mL (60-1 070 mL). There were no significant differences between the two groups in the value of hemoglobin decrease 1 day after surgery (P=0.340) and 3 days after surgery (P=0.524). There were no significant differences in the total blood loss (P=0.101) and the hidden blood loss (P=0.062) between the two groups either. There were 9 patients in the 131 patients who received allogeneic blood transfusion, of whom 5 in the ABT group (5/64, the blood transfusion rate was 7.8%) and 4 in the control group (4/67, the blood transfusion rate was 6.0%), and no significant differences in the blood transfusion rate between the two groups (P=0.943).
CONCLUSION
With the conventional application of using comprehensive hemostatic methods during perioperative period, the ABT device did not show the effective result of controlling postoperative blood loss and failed to reduce the rate of allogeneic blood transfusion in patients with unilateral primary TKA. However, the ABT device could increase the drainage fluid volume and improve the patient's hospitalization expenses. Therefore, there is no need for routine application of ABT device in unilateral primary TKA.
Arthroplasty, Replacement, Knee
;
Blood Loss, Surgical/prevention & control*
;
Blood Transfusion
;
Blood Transfusion, Autologous/instrumentation*
;
Hemostatics
;
Humans
2.Case-control study on individual osteotomy instrument and conventional total knee arthroplasty for the treatment of knee osteoarthritis.
Hua-chen YU ; Yu ZHANG ; Paul WONG
China Journal of Orthopaedics and Traumatology 2016;29(6):513-516
OBJECTIVETo compare clinical efficacy of individual osteotomy instrument and total knee arthrolplasty (TKA) in treating patients with knee osteoarthritis.
METHODSFrom June 2014 to December 2014, 40 patients with unilateral knee osteoarthritis were randomly divided into two groups and 20 cases were in each group. One group (individual group) were treated with TKA with individual osteotomy instrument,including 5 males and 15 females with an average age of (67.3 ± 6.5) years old; 8 cases on the left side and 12 cases on the right side. Another group (conventional group) were treated with conventional TKA , including 6 males and 14 females with an average age of (66.8 ± 7.3) years old; 9 cases on the left side and 11 cases on the right side. Operative time, blood loss, postoperative HSS score at 6 months, and changes of mechanical alignment before and after operation were analyzed.
RESULTSOperative time in individual group was (79.3 ± 4.7) min, and (83.5 ± 3.2) min in conventional group; blood loss in individual group was (287.1 ± 24.9) ml and (363.4 ± 47.2) ml in conventional group, there were statistical differences between two groups in these two items. There was no significant difference in postoperative HSS score at 6 months between individual group (84.8 ± 3.2) and conventional group (84.2 ± 2.5). Postoperative limb alignment in individual group was (2.8 ± 0.6)°, and (2.8 ± 0.6)° in conventional group, with no significant difference between two groups.
CONCLUSIONTKA with individual osteotomy instrument could reduce operative time and blood loss, but there was no differences in knee function, changes of mechanical alignment compared with TKA.
Adult ; Aged ; Arthroplasty, Replacement, Knee ; methods ; Case-Control Studies ; Female ; Humans ; Knee Joint ; surgery ; Male ; Operative Time ; Osteoarthritis, Knee ; surgery ; Osteotomy ; instrumentation ; methods ; Treatment Outcome
3.Are Western Knee Designs Dimensionally Correct for Korean Women? A Morphometric Study of Resected Femoral Surfaces during Primary Total Knee Arthroplasty.
Jun Bae KIM ; Suk Joo LYU ; Hyung Wook KANG
Clinics in Orthopedic Surgery 2016;8(3):254-261
BACKGROUND: The purpose of this study was to determine the shape of the distal femur of Korean women compared with the prostheses currently available in Korea. METHODS: Morphometric data (5 parameters) were measured in 356 resected femurs of Korean women undergoing primary total knee arthroplasty (TKA) utilizing the LCS knee implant (DePuy). The data were then compared with 5 additional contemporary TKA implant systems. RESULTS: Implant designs based on Caucasian population data do not ideally match the distal femoral morphology of Korean women. Overhang at the anterior mediolateral width was observed in 84.8% for the LCS while a gender-specific implant resulted in undercoverage of the bone in 86%. Posterior overhang was observed in up to 51.2%. Most implant designs have a narrower intercondylar notch than the morphologic data of Korean women. CONCLUSIONS: Since there is some difference between the shape of distal femur of Korean women and that of the implants, surgeons should have this in mind when selecting an implant for a patient. These data may also be used as a guideline for future prosthetic design options for Korean women population.
Aged
;
Aged, 80 and over
;
Arthroplasty, Replacement, Knee/*instrumentation/statistics & numerical data
;
Asian Continental Ancestry Group/*statistics & numerical data
;
Cohort Studies
;
Female
;
Femur/*anatomy & histology/*surgery
;
Humans
;
Knee Joint/surgery
;
Middle Aged
;
Prosthesis Design
;
Republic of Korea
4.Relationship between screw numbers and severity of tibial bone defect in primary total knee arthroplasty.
Chong ZHENG ; Yong-gang ZHOU ; Hai-yang MA ; Zhuo ZHANG ; Hua-hao FU ; Wen-ming WU ; Shang PIAO ; Yin-qiao DU ; Sen WANG
China Journal of Orthopaedics and Traumatology 2016;29(5):415-420
OBJECTIVETo summarize experience of using screws and cement to rebuild tibial bone defect in primary total knee arthroplasty (TKA) and to discuss the relationship between the number of required screws and the severity of tibial bone defects.
METHODSFrom July 2009 to May 2015, 34 patients (40 knees) with varus knees underwent TKA, and the screw and cement technique was used to rebuild medial tibia plateau during operation. There were 8 males (8 knees) and 26 females (32 knees), and the average age was (65.00 +/- 7.25) years old (ranged,55 to 82 years old). One to 6 screws were used in each case. Extension stems were used in 2 cases (4 and 5 screws was used respectively). The area percentages of the bone defects measured as defect area/tibia plateau area, depth of each defect, the number of screws needed in each case, were all used to determine the relationship between the number of screws and the area percentage in certain depth of bone defect by statistic methods, as well as the relationship between screw number and defect depth.
RESULTSAll the patients were followed up and the average duration was 24 months (ranged, 1 to 72 months). The average preoperative HSS score was 43.33 +/- 6.11 (ranged, 32 to 51 scores). Whereas the average postoperative HSS score was 92.15 +/- 4.64 (ranged,83 to 96 scores). The preoperative individual scores including pain, function, activity, nuscle strength, flexion deformity and stability were all improved compared with preoperation,and the differences were statistically significant. All the patients received normal alignment postoperatively, femoraltibial angle was improved from (167.00 +/- 6.39) degrees preoperatively to (175.00 +/- 2.69) degrees postoperatively, the tibial angle was improved from (78.09 +/- 4.51) degrees preoperatively to (88.75 +/- 1.24) degrees postoperatively. Both area percentage and depth of bone defect in a fitting Ologistic model had a significant statistical relationship with the screw number, and a rectangular coordinate system could be formed according to the relationship.
CONCLUSIONScrews and cement technique is a simple, safe and convenient method to rebuild tibial bone defects in primary TKA and its short-term and midterm effect are both reliable. During opera- tion, according to the rectangular coordinate system, the screw number needed in the operation can be inferred form th area and depth of tibia defect, which could have a guiding function in surgery.
Aged ; Aged, 80 and over ; Arthroplasty, Replacement, Knee ; instrumentation ; methods ; Bone Screws ; utilization ; Female ; Fracture Fixation, Internal ; Humans ; Knee Injuries ; surgery ; Knee Joint ; surgery ; Male ; Middle Aged ; Tibia ; surgery
5.A Novel Non-Invasive Adjuvant Biomechanical Treatment for Patients with Altered Rehabilitation after Total Knee Arthroplasty: Results of a Pilot Investigation.
Lee YAARI ; Yona KOSASHVILI ; Ganit SEGAL ; Shai SHEMESH ; Steven VELKES ; Amit MOR ; Ronen DEBI ; Benjamin BERNFELD ; Avi ELBAZ
Clinics in Orthopedic Surgery 2015;7(2):191-198
BACKGROUND: Many factors contribute to suboptimal results after total knee arthroplasty (TKA) but little is known regarding the value of postsurgical rehabilitation after TKA. We examined the effects of an enhanced closed kinematic chain exercises program (AposTherapy) on gait patterns and clinical outcomes among patients with a lack of progress in their postsurgical rehabilitation. METHODS: Twenty-two patients were prospectively followed during the study. Gait spatiotemporal parameters were measured at the initial evaluation, after 15 minutes of therapy, and after 3 months of therapy. The Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and the short form (SF) 36 health survey were completed by patients before treatment and after 3 months of treatment. RESULTS: The WOMAC and SF-36 scores improved significantly after 3 months of treatment. Gait velocity, single limb support, and step length of the operated leg improved significantly even after a single 15 minutes treatment. Normal gait velocity was observed in 36% of patients after 3 months of treatment. CONCLUSIONS: A physiotherapy program that included enhanced closed kinematic chain biomechanical therapy was beneficial for patients who experienced a suboptimal rehabilitation course after TKA.
Aged
;
Aged, 80 and over
;
Arthroplasty, Replacement, Knee/*rehabilitation
;
Biomechanical Phenomena
;
Female
;
Humans
;
Male
;
Middle Aged
;
Physical Therapy Modalities/*instrumentation
;
Pilot Projects
;
Postoperative Complications/*therapy
;
Prospective Studies
;
Shoes
;
Treatment Failure
6.Two-Stage Revision for Infected Total Knee Arthroplasty: Based on Autoclaving the Recycled Femoral Component and Intraoperative Molding Using Antibiotic-Impregnated Cement on the Tibial Side.
Byoung Joo LEE ; Hee Soo KYUNG ; Seong Dae YOON
Clinics in Orthopedic Surgery 2015;7(3):310-317
BACKGROUND: The purpose of this study was to determine the degree of infection control and postoperative function for new articulating metal-on-cement spacer. METHODS: A retrospective study of 19 patients (20 cases), who underwent a two-stage revision arthroplasty using mobile cement prosthesis, were followed for a minimum of 2 years. This series consisted of 16 women and 3 men, having an overall mean age of 71 years. During the first stage of revision, the femoral implant and all the adherent cement was removed, after which it was autoclaved before replacement. The tibial component was removed and a doughy state, antibiotic-impregnated cement was inserted on the tibial side. To achieve joint congruency, intraoperative molding was performed by flexing and extending the knee joint. Each patient was evaluated clinically and radiologically. The clinical assessments included range of motion, and the patients were scored as per the Hospital for Special Surgery (HSS) and Knee Society (KS) criteria. RESULTS: The mean range of knee joint motion was 70degrees prior to the first stage operation and 72degrees prior to the second stage revision arthroplasty; following revision arthroplasty, it was 113degrees at the final follow-up. The mean HSS score and KS knee and function scores were 86, 82, and 54, respectively, at the final follow-up. The success rate in terms of infection eradication was 95% (19/20 knees). No patient experienced soft tissue contracture requiring a quadriceps snip. CONCLUSIONS: This novel technique provides excellent radiological and clinical outcomes. It offers a high surface area of antibiotic-impregnated cement, a good range of motion between first and second stage revision surgery for the treatment of chronic infection after total knee arthroplasty, and is of a reasonable cost.
Aged
;
Anti-Bacterial Agents/*administration & dosage/*therapeutic use
;
Arthroplasty, Replacement, Knee/*adverse effects/*instrumentation/methods
;
Bone Cements/*therapeutic use
;
Female
;
Humans
;
Male
;
Middle Aged
;
Prosthesis-Related Infections/*surgery
;
Range of Motion, Articular/physiology
;
Reoperation/*instrumentation/methods
;
Retrospective Studies
;
Treatment Outcome
7.Total Knee Replacement Arthroplasty with Buechel and Pappas Knee: Minimum 2-Year Follow-up.
Kyoung Ho MOON ; Seung Hyun HONG ; Taek Ho HONG
Clinics in Orthopedic Surgery 2015;7(1):62-68
BACKGROUND: Clinical and radiologic evaluation and analyses of the surgeries using Buechel and Pappas (B-P) knee implants. METHODS: The study was conducted on 60 patients who underwent 94 total knee replacement arthroplasty with B-P knee implants from May 2009 to December 2010. The results were compared to the results of 41 patients who underwent 60 knee joint surgeries using NexGen-LPS implants from January 2008 to August 2009. RESULTS: The American Knee Society score of the B-P knee group increased from an average of 66.9 (clinical score) and 65.5 (functional score) to 93.4 and 90.3, respectively; while those for the NexGen-LPS group increased from an average of 68.8 (clinical score) and 62.4 (functional score) to 86.3 and 76, respectively. The average ranges of motion of the B-P knee group and the NexGen-LPS group were 119.1degrees and 114.8degrees, respectively, before surgery and improved to 121.0degrees and 123.0degrees at final follow-up after the surgery. The visual analogue scale scores for the B-P knee group and the NexGen-LPS group improved from 4.7 and 4.6 to 1.4 and 1.8, respectively. The flexion contracture also improved from 5.1degrees and 6.3degrees to 0.64degrees and 1.72degrees. The tibio-femoral angle for the B-P knee group and the NexGen-LPS group also improved greatly after the surgery, from varus 0.34degrees and 0.73degrees each to valgus 6.7degrees and 6.9degrees, respectively. CONCLUSIONS: The evaluation of more than 2 years of total knee replacement arthroplasty using B-P knee implants showed good results. B-P knee implants showed a relatively higher degree of satisfaction in clinical knee score and less intraoperative bone mass removal than NexGen-LPS implants.
Aged
;
Aged, 80 and over
;
Arthroplasty, Replacement, Knee/*instrumentation
;
Female
;
Follow-Up Studies
;
Humans
;
Knee Joint/radiography/*surgery
;
*Knee Prosthesis
;
Male
;
Middle Aged
;
Osteoarthritis, Knee/radiography/*surgery
8.Advantage of Minimal Anterior Knee Pain and Long-term Survivorship of Cemented Single Radius Posterior-Stabilized Total Knee Arthroplasty without Patella Resurfacing.
Hyung Min JI ; Yong Chan HA ; Ji Hoon BAEK ; Young Bong KO
Clinics in Orthopedic Surgery 2015;7(1):54-61
BACKGROUND: The single radius total knee prosthesis was introduced with the advantage of reduced patellar symptoms; however, there is no long-term follow-up study of the same. The purpose of this study was to determine the survival rate of single radius posterior-stabilized total knee arthroplasty and patellofemoral complication rates in a consecutive series. METHODS: Seventy-one patients (103 knees) who underwent arthroplasty without patellar resurfacing using a single radius posterior-stabilized total knee prosthesis were followed up for a minimum 10 years. Clinical evaluation using Knee Society knee and function scores and radiologic evaluation were performed at regular intervals. Anterior knee pain as well as patellofemoral complications were evaluated with a simple questionnaire. The Kaplan-Meier product-limit method was used to estimate survival. RESULTS: Seventeen patients (23 knees) were excluded due to death (12 knees) or lost to follow-up (11 knees). Of the 80 knees enrolled, all femoral components and 78 tibial components were well fixed without loosening at final follow-up. Two revisions were performed because of tibial component loosening and periprosthetic joint infection. One patient with tibial component loosening refused to have revision surgery. No obvious tibial insert polyethylene wear was observed. The survivorships at 132 months were 96.7% using revision or pending revision as end points. Anterior knee pain was present in 6 patients (6 knees, 7.5%) at the latest follow-up. No patellofemoral complication requiring revision was encountered. CONCLUSIONS: The single radius posterior-stabilized total knee prosthesis demonstrated an excellent minimum 10-year survivorship. The low rates of implant loosening and 7.5% of anterior knee pain as a patellofemoral complication are comparable with those reported for other modern total knee prosthesis.
Aged
;
Arthralgia/*surgery
;
Arthroplasty, Replacement, Knee/*instrumentation/*methods
;
Cementation
;
Female
;
Follow-Up Studies
;
Humans
;
Knee Joint/*surgery
;
Knee Prosthesis
;
Male
;
Middle Aged
;
Patella/surgery
;
Prosthesis Failure
;
Retrospective Studies
;
Treatment Outcome
9.Does Limited Tourniquet Usage in Primary Total Knee Arthroplasty Result in Better Functional Outcomes?
Gurpal SINGH ; Fucai HAN ; Ratnakar Rao KAKI ; Liang SHEN ; Saminathan Suresh NATHAN
Annals of the Academy of Medicine, Singapore 2015;44(8):302-306
Aged
;
Arthroplasty, Replacement, Knee
;
adverse effects
;
methods
;
Case-Control Studies
;
Female
;
Follow-Up Studies
;
Humans
;
Incidence
;
Intraoperative Care
;
instrumentation
;
methods
;
Male
;
Middle Aged
;
Osteoarthritis, Knee
;
surgery
;
Postoperative Complications
;
diagnosis
;
epidemiology
;
etiology
;
prevention & control
;
Recovery of Function
;
Risk Assessment
;
Singapore
;
epidemiology
;
Tourniquets
;
adverse effects
;
Treatment Outcome
10.Saline-Coupled Bipolar Sealing in Simultaneous Bilateral Total Knee Arthroplasty.
Atul F KAMATH ; Daniel C AUSTIN ; Peter B DERMAN ; R Carter CLEMENT ; Jonathan P GARINO ; Gwo Chin LEE
Clinics in Orthopedic Surgery 2014;6(3):298-304
BACKGROUND: The efficacy of saline-coupled bipolar sealing devices in joint arthroplasty is uncertain, and the utility in simultaneous bilateral total knee arthroplasty (TKA) has not been reported. METHODS: This study compares the use of bipolar sealing and conventional electrocautery in 71 consecutive patients. The experimental and control groups were matched for age, sex, body mass index, American Society of Anesthesiologists (ASA) classification, and preoperative hemoglobin. Variables of interest included blood loss, transfusion requirements, and operative characteristics. RESULTS: In comparison to patients treated with conventional electrocautery, those treated with the bipolar sealer were 35% less likely to require transfusion. The median number of transfusions per case was also significantly lower in the experimental group. Hemoglobin change, total blood loss, and length of stay were not significantly different between the groups. The experimental group had longer operative times. CONCLUSIONS: Bipolar sealing shows promise as a blood loss reduction tool in simultaneous bilateral TKA. The marginal savings attributed to reduced transfusion rates with use of the bipolar sealer did not exceed the additional per-case expense of using the device. The decision to use the device with the goal of less blood loss must come with the additional expense associated with its use.
Adult
;
*Arthroplasty, Replacement, Knee
;
Blood Loss, Surgical/*prevention & control
;
Catheter Ablation/instrumentation
;
Electrocoagulation/*instrumentation
;
Female
;
Humans
;
Male

Result Analysis
Print
Save
E-mail