1.Medium term follow up outcomes of uncemented total hip arthroplasty for traumatic arthritis after intramedullary nail fixation of femoral intertrochanteric fracture.
Guan-Ming TIAN ; Pei LI ; Da-Wei BI
China Journal of Orthopaedics and Traumatology 2023;36(11):1026-1030
OBJECTIVE:
To evaluate the effect of uncemented total hip arthroplasty(THA) on treatment of traumatic arthritis caused by intramedullary nailing interfixation of intertrochanteric fractures.
METHODS:
Total of 22 patients treated with THA due to traumatic arthritis caused by intramedullary nailing interfixation of intertrochanteric fractures from January 2012 to January 2017 were studied retrospectively, including 10 males and 12 females with a mean age of (72.5±9.8) years old ranging from 61 to 84 years old. Initial internal fixation method:14 patients were treated with Gamma nails and 8 patients were treated wit PFNA.The time from internal fixation surgery to THA was 10 to 68 months with an average of (32.2±21.3) months.Harris scores of the hip joint before and after surgery were compared, and the position of the prosthesis through postoperative imaging at 3, 6, 12 months and the last follow-up were evaluated.
RESULTS:
One patient was died due to heart failure 1 year after operation. Two patients was died to advanced tumor 2 years after operation. The other 19 patients were followed up for 36 to 64 months with an average of (48.5±11.9) months. At final follow up, 14 patients regained the ability to walk independently, 4 patients needed support of a cane, 1 patient needed assistance of a walker. No serious complications such as joint dislocation, periprosthetic fracture and deep venous thrombosis occurred during follow-up. There were no signs of loosening and subsidence of the prosthesis at the final follow-up. Mean Harris hip score increased from (29.2±12.9) points preoperatively to (74.2±11.2) points at the final follow up(P<0.05);the score was excellent in 9 patients, good in 7 and fair in 3.
CONCLUSION
Uncemented total hip arthroplasty for traumatic arthritis after intramedullary nail fixation of femoral intertrochanteric fracture can significantly improve hip function and effectively avoid bone cement implantation syndrome. The medium-term effect is satisfactory.
Male
;
Female
;
Humans
;
Middle Aged
;
Aged
;
Aged, 80 and over
;
Arthroplasty, Replacement, Hip/methods*
;
Follow-Up Studies
;
Treatment Outcome
;
Retrospective Studies
;
Bone Nails
;
Hip Fractures/surgery*
;
Fracture Fixation, Intramedullary/adverse effects*
;
Arthritis/surgery*
2.Possible Risk Factors for Severe Complications Occurring after Primary Total Knee Arthroplasty.
Ma LU-LU ; Yu XUE-RONG ; Weng XI-SHENG ; Lin JIN ; Jin JIN ; Qian WEN-WEI ; Huang YU-GUANG
Chinese Medical Sciences Journal 2022;37(4):303-308
Objective Total knee arthroplasty is one of the most common orthopedic surgeries. Readmission due to severe complications after total knee arthroplasty is a grave concern to surgeons. In this study, we evaluated the risk factors for severe complications after primary total knee arthroplasty. Methods We retrospectively collected clinical data of 2,974 patients who underwent primary total knee arthroplasty from July 2013 to June 2019 in our hospital. Postoperative complication ≥ grade Ⅲ was defined as severe complication according to Clavien-Dindo classification system. Binary logistic regression was used to identify the predictive risk factors for severe complications. Results The complication rate after primary total knee arthroplasty was 6.8% and severe complication rate was 2.5%. Male (OR = 2.178, 95%CI: 1.324-3.585, P= 0.002), individuals above 75 years old (OR = 1.936, 95%CI: 1.155-3.244, P= 0.012), arrhythmia (OR = 2.913, 95%CI: 1.350-6.285, P= 0.006) and cerebrovascular disease (OR = 2.804, 95%CI: 1.432-5.489, P= 0.003) were predictive risk factors for severe complications after primary total knee arthroplasty. Conclusion Advanced age, male, arrhythmia, and cerebrovascular disease might be patients-related risk factors for postoperative severe complications after primary total knee arthroplasty. Special attention should be paid to patients with risk factors.
Humans
;
Male
;
Aged
;
Arthroplasty, Replacement, Knee/methods*
;
Comorbidity
;
Retrospective Studies
;
Risk Factors
;
Postoperative Complications/etiology*
;
Arthroplasty, Replacement, Hip/adverse effects*
3.Total hip arthroplasty for posttraumatic osteoarthritis following acetabular fracture: A systematic review of characteristics, outcomes, and complications.
Robert D STIBOLT ; Harshadkumar A PATEL ; Samuel R HUNTLEY ; Eva J LEHTONEN ; Ashish B SHAH ; Sameer M NARANJE
Chinese Journal of Traumatology 2018;21(3):176-181
PURPOSEPosttraumatic arthritis (PTA) may develop years after acetabular fracture, hindering joint function and causing significant chronic musculoskeletal pain. Given the delayed onset of PTA, few studies have assessed outcomes of delayed total hip arthroplasty (THA) in acetabular fracture patients. This study systematically reviewed the literature for outcomes of THA in patients with PTA and prior acetabular fracture.
METHODSPubmed, EMBASE, SCOPUS, and Cochrane library were searched for articles containing the keywords "acetabular", "fracture", "arthroplasty", and "post traumatic arthritis" published between 1995 and August 2017. Studies with less than 10 patients, less than 2 years of follow-up, conference abstracts, and non-English language articles were excluded. Data on patient demographics, surgical characteristics, and outcomes of delayed THA, including implant survival, complications, need for revision, and functional scores, was collected from eligible studies.
RESULTSWith 1830 studies were screened and data from 10 studies with 448 patients were included in this review. The median patient age on date of THA was 51.5 years, ranging from 19 to 90 years. The median time from fracture to THA was 37 months, with a range of 27-74 months. Mean follow-up times ranged from 4 to 20 years. The mean Harris hip scores (HHS) improved from 41.5 pre-operatively, to 87.6 post-operatively. The most prevalent postoperative complications were heterotopic ossification (28%-63%), implant loosening (1%-24%), and infection (0%-16%). The minimum 5-year survival of implants ranged from 70% to 100%. Revision rates ranged from 2% to 32%.
CONCLUSIONDespite the difficulties associated with performing THA in patients with PTA from previous acetabular fracture (including soft tissue scarring, existing hardware, and acetabular bone loss) and the relatively high complication rates, THA in patients with PTA following prior acetabular fracture leads to significant improvement in pain and function at 10-year follow-up. Further high quality randomized controlled studies are needed to confirm the outcomes after delayed THA in these patients.
Acetabulum ; injuries ; Adult ; Aged ; Aged, 80 and over ; Arthroplasty, Replacement, Hip ; adverse effects ; methods ; Fractures, Bone ; complications ; Humans ; Middle Aged ; Osteoarthritis ; surgery ; Postoperative Complications ; etiology
4.Continuous lumbar plexus block reduces the incidence of early postoperative cognitive dysfunction in elderly patients undergoing hip arthroplasty.
Jing LI ; Buhuai DONG ; Wenbo CAI ; Gang WANG
Journal of Central South University(Medical Sciences) 2018;43(8):858-863
To observe the impacts of continuous lumbar plexus block (CLPB) on postoperative cognitive dysfunction (POCD) in elderly patients undergoing hip arthroplasty.
Methods: Sixty elderly patients scheduled for hip arthroplasty with general anesthesia, were randomly allocated into a CLPB group and a PCIA group (n=30 each). In the CLPB group, lumbar plexus block was performed before trachea intubation, and CLPB was used for postoperative analgesia. In the PCIA group, intravenous analgesia was controlled in patients after operation. Visual Analogue Scale (VAS) at 12, 24, and 48 h after operation was recorded. Mini-Mental State Examination (MMSE) scale was used to evaluate the cognitive dysfunction at the 1st day before operation (D0) and at the 1st (D1), 3rd (D3), and 7th (D7) days after operation and the occurrence of POCD was recorded. S-100β concentrations were detected by ELISA at D1, D3, and D7. Postoperative adverse events were recorded.
Results: VAS scores at 12, 24, and 48 h after operation in the CLPB group were significantly lower than those in the PCIA group (P<0.05). Compared with the PCIA group, the MMSE scores were significantly higher (P<0.05), and the incidence of POCD at D1 and D3 was obviously reduced in the CLPB group (P<0.05). S-100β concentration at D1 and D3 in the CLPB group was significantly lower than that in the PCIA group (P<0.05).
Conclusion: Application of CLPB in elderly patients undergoing hip arthroplasty could obviously relieve their postoperative pain, inhibit the production of S-100β, and reduce the incidence of early postoperative cognitive dysfunction.
Aged
;
Analgesics
;
administration & dosage
;
Arthroplasty, Replacement, Hip
;
adverse effects
;
Cognitive Dysfunction
;
prevention & control
;
Humans
;
Incidence
;
Lumbosacral Plexus
;
Nerve Block
;
methods
;
Pain Measurement
;
Pain, Postoperative
;
prevention & control
;
Postoperative Complications
;
prevention & control
5.Research progress in strategy of lateral femoral offset reconstruction in total hip arthroplasty.
Qiu-ping FAN ; Bo WANG ; Wei-ping JI
China Journal of Orthopaedics and Traumatology 2016;29(2):192-196
As an important indicator of total hip arthroplasty (THA) the rate and degree of offset reconstruction play an important role in improving the prognosis and life quality of patients. The reconstruction of femoral offset is closely related to reserved length of calcar femorale, the head and neck length of prosthesis, angle degree of neck shaft and whether lower limb is isometric. Reconstruction strategy includes making a meticulous and standard measurement before the surgery, predicting the reserved length of calcar femorale, selecting a prosthesis with approximate anatomical neck-shaft angle and reconstructing offset by adjusting the head and neck length of the prosthetic during the operation. The aim of this article was to introduce the research progress and influence of offset on hip function, prosthetic wear and postoperative complications such as pain, limp and unequal leg length, and to discuss the reconstruction strategy.
Arthroplasty, Replacement, Hip
;
adverse effects
;
methods
;
Femur
;
surgery
;
Humans
;
Reconstructive Surgical Procedures
;
adverse effects
;
methods
6.Case-control study on methods of limb length control in hip arthroplasty.
Yang-yang ZHANG ; Jian-lin ZUO ; Zhong-li GAO
China Journal of Orthopaedics and Traumatology 2016;29(2):102-106
OBJECTIVETo introduce a new measuring tool for measuring postoperative limb length exactly, and to provide a convenient and effective method to control limb length after total hip replacement.
METHODSFrom January 2013 to September 2014, 102 patients undergoing primary unilateral hip replacement were divided into two groups: experimental group and control group. There were 51 patients in the experimental group, including 25 males and 26 females, ranging in age from 37 to 92 years old, with an average of 60.41 years old. The patients in experimental group were treated with new method to control limb length. Other 51 patients in the control group, including 27 males and 24 females, ranging in age from 35 to 87 years old, with an average of 61.00 years old. The patients in the control group were treated with normal methods such as shuck test or limb touching. All the patients were operated by the same experienced surgeon. In the experimental group,total hip arthroplasties (THA) were performed on 35 patients with avascular necrosis of the femoral head or femoral neck fracture, and 16 patients were treated with hemiarthroplasty (HA). In the control group, 38 patients received THA and 13 patients received HA. On the anterior-posterior X-ray radiograph, several indexes were measured as follows: the distance of bilateral femoral offset (a), the height from tip of great trochanter to the rotation center of the femoral head (b) and the vertical distance between the top of the minor trochanter and the two tear drops line (c). The leg length discrepancy can be assessed with three parameters as follows: d1, the absolute value of the difference between the bilateral a values; d2, the difference between the bilateral b values; d3, the difference between the bilateral c values. The SPSS 21.0 was applied for the statistical analysis.
RESULTSIn the experimental and control groups, d1 were 4.49 mm and 7.32 mm (P = 0.013); d2 were 2.37 mm and 4.32 mm (P = 0.033); d3 were 3.32 mm and 6.08 mm (P = 0.031). The values of d1, d2 and d3 in the experimental group were significant smaller than those in the control group.
CONCLUSIONThe new measuring tool and method can be used to control the limb length and offset effectively during operation.
Adult ; Aged ; Aged, 80 and over ; Arthroplasty, Replacement, Hip ; adverse effects ; methods ; Case-Control Studies ; Female ; Humans ; Leg Length Inequality ; prevention & control ; Male ; Middle Aged
7.Results of Total Hip Arthroplasty after Core Decompression with Tantalum Rod for Osteonecrosis of the Femoral Head.
Gun Woo LEE ; Kyung Soon PARK ; Do Youn KIM ; Young Min LEE ; Kamolhuja Eshnazarovich ESHNAZAROV ; Taek Rim YOON
Clinics in Orthopedic Surgery 2016;8(1):38-44
BACKGROUND: Early stage osteonecrosis of the femoral head (ONFH) has many treatment options including core decompression with implantation of a tantalum rod. The purpose of this study was to evaluate clinical and radiological outcomes and potential complications during conversion total hip arthroplasty (THA) in such patients. METHODS: Six male patients (8 hips) underwent THA subsequent to removing a tantalum rod (group I) from April 2010 to November 2011. We retrospectively reviewed the medical records of these patients. We enrolled 12 age- and sex-matched patients (16 hips) during the same period, who had undergone primary THA without a previous operation as the control group (group II). All patients were followed for at least 3 years. We checked the Harris hip score (HHS), operative time, and volume of blood loss. Radiological results, including inclination, anteversion of the acetabular cup, presence of periprosthetic osteolysis, and subsidence of femoral stem were checked at the last follow-up. RESULTS: The mean preoperative HHS values were 56.5 (range, 50 to 62) and 59.1 (range, 42 to 70) in groups I and II, respectively. The HHS improved to 96.0 (range, 93 to 100) and 97.6 (range, 93 to 100), respectively, at the 3-year follow-up (p = 0.172). Mean operation time was 98.8 minutes (range, 70 to 120 minutes) in group I and 77.5 minutes (range, 60 to 115 minutes) in group II (p = 0.006). Total blood loss volumes were 1,193.8 mL (range, 960 to 1,360 mL) and 944.1 mL (range, 640 to 1,280 mL) in groups I and II, respectively (p = 0.004). No significant differences in inclination or anteversion of acetabular cup and no evidence of osteolysis or subsidence of the femoral stem were reported in either group in radiological follow-up results. However, one case of squeaking occurred in group I during the follow-up. CONCLUSIONS: The two groups showed no clinical or radiological differences except extended operative time and increased blood loss. However, the incidence of squeaking (1 of 8 hips) was higher, as compared to the control group or previously reported values.
Adult
;
*Arthroplasty, Replacement, Hip/adverse effects/methods/statistics & numerical data
;
Case-Control Studies
;
*Decompression, Surgical/adverse effects/methods/statistics & numerical data
;
Femur Head/diagnostic imaging/surgery
;
Femur Head Necrosis/diagnostic imaging/*surgery
;
Humans
;
Male
;
Postoperative Complications
;
Reoperation
;
Retrospective Studies
;
Tantalum/*therapeutic use
;
Tomography, X-Ray Computed
;
Treatment Outcome
8.Total Hip Arthroplasty around the Inception of the Interface Bioactive Bone Cement Technique.
Hiroyuki OONISHI ; Hirotsugu OHASHI ; Ikuo KAWAHARA
Clinics in Orthopedic Surgery 2016;8(3):237-242
BACKGROUND: To augment cement-bone fixation, Dr. Hironobu Oonishi attempted additional physicochemical bonding through interposition of osteoconductive crystal hydroxyapatite (HA) granules at the cement-bone interface in 1982. He first used the interface bioactive bone cement (IBBC) technique in 12 selected patients (12 hips) in 1982 (first stage) and followed them for 2 years. In 1985, the technique was applied in 25 total hip arthroplasty (THA) patients (second stage) and the effects were investigated by comparing the side with the IBBC technique and the other side without the IBBC technique. He has employed this technique in all THA patients since 1987 (third stage). METHODS: In the IBBC technique, HA granules (2 to 3 g) were smeared on the bone surface just before the acetabular and femoral components were cemented. In the first stage, 12 hips were operated using the IBBC technique in 1982. In the second stage, THA was performed without the IBBC technique on one side and with the IBBC technique on the other side within 1 year in 25 patients. In the third stage, THA was performed with the IBBC technique in 285 hips in 1987. RESULTS: In the first stage patients, implant loosening was not detected at 30 years after operation. In the second stage patients, revision was required in 7 hips without the IBBC technique due to cup loosening (5 hips) and stem loosening (2 hips), whereas no hip was revised after THA with the IBBC technique at 26 years after operation. In the third stage patients, the incidence of radiolucent lines and osteolysis was very few at 25 years after operation. CONCLUSIONS: The long-term follow-up of THA performed around the inception of the IBBC technique has revealed low incidences of radiolucent lines, osteolysis, and revision surgery.
Adult
;
Aged
;
Aged, 80 and over
;
*Arthroplasty, Replacement, Hip/adverse effects/instrumentation/methods
;
*Bone Cements/adverse effects/therapeutic use
;
Bone-Implant Interface/physiology
;
Follow-Up Studies
;
Hip/diagnostic imaging/surgery
;
Humans
;
Hydroxyapatites/therapeutic use
;
Middle Aged
;
Young Adult
9.Progress of clinical application of ETO in rTHR.
Zhi-Yue ZHA ; Xin QI ; Chen YANG ; Shu-Qiang LI
China Journal of Orthopaedics and Traumatology 2015;28(3):286-290
How to remove the well fixed cement or cementless prosthesis and get a completely distal cement removal in the rTHR are critical to the outcome of revision. Because of higher rate of union, excellent intraoperative exposure, and adjustment of abductor tension, ETO has been widely applied to rTHR and complicated primary THR by foreign scholars. Furthermore, this technology has wide indications, very few contraindications, high cure rates,and low complications rate. ETO turns out to be a safe and effective revision technology. In the article, the indication, contraindication, complications and advantages of this technique were reviewed.
Arthroplasty, Replacement, Hip
;
methods
;
Humans
;
Osteotomy
;
adverse effects
;
methods
10.Analysis on morphology and stability of femoral hip prosthesis based on the revision operation.
Zhong-Han MIN ; Hong-Mei ZHANG ; Ying ZHOU ; Shi-Gui YAN ; Hong-Min QIN ; Xian-Cai YE ; Zhen-Kang ZHU ; Jing LIN ; Ge-Jun ZHAO
China Journal of Orthopaedics and Traumatology 2015;28(3):205-209
OBJECTIVEAccording to the information obtained from the revision of total hip arthroplasty, the situations of the artificial femoral stem under physiological stress were analyzed preliminarily. In order to accumulate clinical experience, the discussions about how to enlongate the life of artifical joints were performed.
METHODSFifty-three patients required revision operations were selected, including 28 males and 25 females,with an average age of 74.66 years old (61 to 84 years old). The average life of artificial joints was 18.24 years (3 to 27 years). The initial weightbearing was started 11 days (5 to 16 days) after the first operation. The main reasons for the revision were the spontaneous loosening and trauma. Based on imaging and surgical findings, as well as the histological pathology, the situations of the stems in human bodies were determined.
RESULTSFemoral prosthesis would sink under physiological stress. The design of femoral stems, motion of patients', and bone growth determined the secondary stability. Straight stems were helpful for physiological subsidence of prosthesis, achieving the stability with close bone-implant contact by bone growth,which allowed the patient to do early landing exercise. The collared prosthesis and prosthesis combined with internal fixation limited the subsidence of femoral stems. Their stability depends on the time of initial placement and the bone growth for supporting. Delaying the inital weightbearing was suggested for patients with these protheses.
CONCLUSIONAccording to the actual situation of the patients, the appropriate chosen of femoral stems and time to perform the weightbearing can extend the life of the femoral prosthesis.
Aged ; Aged, 80 and over ; Arthroplasty, Replacement, Hip ; adverse effects ; methods ; Female ; Hip Prosthesis ; Humans ; Male ; Middle Aged ; Prosthesis Design

Result Analysis
Print
Save
E-mail