3.Gender differences in mortality following tanscatheter aortic valve replacement (TAVR): a single-centre retrospective analysis from China.
Qi LIU ; Yali WANG ; Yijian LI ; Tianyuan XIONG ; Fei CHEN ; Yuanweixiang OU ; Xi WANG ; Yijun YAO ; Kaiyu JIA ; Yujia LIANG ; Xin WEI ; Xi LI ; Yong PENG ; Jiafu WEI ; Sen HE ; Qiao LI ; Wei MENG ; Guo CHEN ; Wenxia ZHOU ; Mingxia ZHENG ; Xuan ZHOU ; Zhengang ZHAO ; Chen MAO ; Feng YUAN
Chinese Medical Journal 2023;136(20):2511-2513
4.Peri-procedural myocardial injury predicts poor short-term prognosis after TAVR: A single-center retrospective analysis from China.
Qi LIU ; Kaiyu JIA ; Yijun YAO ; Yijian LI ; Tianyuan XIONG ; Fei CHEN ; Yuanweixiang OU ; Xi WANG ; Yujia LIANG ; Xi LI ; Yong PENG ; Jiafu WEI ; Sen HE ; Qiao LI ; Wei MENG ; Guo CHEN ; Wenxia ZHOU ; Mingxia ZHENG ; Xuan ZHOU ; Yuan FENG ; Mao CHEN
Chinese Medical Journal 2023;136(24):3013-3015
6.In Vitro Experimental Study on Hemodynamics of Transcatheter Aortic Valve Replacement.
Chinese Journal of Medical Instrumentation 2023;47(4):383-390
The patient-specific aortic silicone model was established based on CTA data. The digital particle image velocimetry (DPIV) test method in the modified ViVitro pulsatile flow system was used to investigate the aortic hemodynamic performance and flow field characteristics before and after transcatheter aortic valve replacement (TAVR). The results showed that the hemodynamic parameters were consistent with the clinical data, which verified the accuracy of the model. From the comparative study of preoperative and postoperative effective orifice area (0.33 cm2 and 1.78 cm2), mean pressure difference (58 mmHg and 9 mmHg), percentage of regurgitation (52% and 8%), peak flow velocity (4.60 m/s and 1.81 m/s) and flow field distribution (eccentric jet and uniform jet), the immediate efficacy after TAVR is good. From the perspective of viscous shear stress and Reynolds shear stress, the risk of hemolysis and thrombotic problems was low in preoperative and postoperative patient-specific models. This study provides a set of reliable DPIV testing methods for aortic flow field, and provides biomechanical basis for the immediate and long-term effectiveness of TAVR from the perspective of hemodynamics and flow field characteristics. It has important application value in clinical diagnosis, surgical treatment and long-term evaluation.
Humans
;
Transcatheter Aortic Valve Replacement/methods*
;
Aortic Valve/surgery*
;
Heart Valve Prosthesis
;
Hemodynamics
;
Aortic Valve Stenosis/diagnosis*
;
Treatment Outcome
10.Preliminary experience of transcatheter pulmonary valve replacement using domestic balloon-expandable valve.
Zhen Gang ZHAO ; Rui Tao LI ; Xin WEI ; Yong PENG ; Jia Fu WEI ; Sen HE ; Qiao LI ; Xiao LI ; Yi Jian LI ; Xiang LI ; Xuan ZHOU ; Ming Xia ZHENG ; Guo CHEN ; Qi AN ; Mao CHEN ; Yuan FENG
Chinese Journal of Cardiology 2023;51(8):825-831
Objectives: To evaluate the feasibility and preliminary clinical results of transcatheter pulmonary valve replacement (TPVR) with the domestically-produced balloon-expandable Prizvalve system. Methods: This is a prospective single-center observational study. Patients with postoperative right ventricular outflow tract (RVOT) dysfunction, who were admitted to West China Hospital of Sichuan University from September 2021 to March 2023 and deemed anatomically suitable for TPVR with balloon-expandable valve, were included. Clinical, imaging, procedural and follow-up data were analyzed. The immediate procedural results were evaluated by clinical implant success rate, which is defined as successful valve implantation with echocardiography-assessed pulmonary regurgitation
Male
;
Humans
;
Pulmonary Valve/surgery*
;
Heart Valve Prosthesis/adverse effects*
;
Heart Valve Prosthesis Implantation
;
Constriction, Pathologic/surgery*
;
Prospective Studies
;
Ventricular Outflow Obstruction/surgery*
;
Treatment Outcome
;
Cardiac Catheterization/methods*
;
Transcatheter Aortic Valve Replacement

Result Analysis
Print
Save
E-mail