1.Research advances in autoimmune pancreatitis with pancreatic exocrine insufficiency
Xiang AO ; Chenxiao LIU ; Xianda ZHANG ; Taojing RAN ; Chunhua ZHOU ; Duowu ZOU
Journal of Clinical Hepatology 2025;41(2):395-400
Autoimmune pancreatitis is a special type of chronic pancreatitis that can lead to abnormal pancreatic exocrine function in patients. Autoimmune pancreatitis comorbid with pancreatic exocrine insufficiency has a complex pathogenesis, and there is limited research on this topic, leading to the lack of understanding of such patients in clinical practice. This article introduces the epidemiology of autoimmune pancreatitis, briefly describes the pathogenesis of pancreatic exocrine insufficiency caused by autoimmune pancreatitis, and summarizes the various detection methods for pancreatic exocrine function, nutritional assessments, lifestyle management, and drug therapy, in order to strengthen the understanding of autoimmune pancreatitis comorbid with pancreatic exocrine insufficiency and improve the clinical diagnosis and treatment of pancreatic exocrine insufficiency.
2.The Quantitative Analysis of Dynamic Mechanisms Impacting Gastric Cancer Cell Proliferation via Serine/glycine Conversion
Jun-Wu FAN ; Xiao-Mei ZHU ; Zhi-Yuan FAN ; Bing-Ya LIU ; Ping AO ; Yong-Cong CHEN
Progress in Biochemistry and Biophysics 2024;51(3):658-672
ObjectiveGastric cancer (GC) seriously affects human health and life, and research has shown that it is closely related to the serine/glycine metabolism. The proliferation ability of tumor cells is greatly influenced by the metabolism of serine and glycine. The aim of this study was to investigate the molecular mechanism of serine/glycine metabolism can affect the proliferation of gastric cancer cells. MethodsIn this work, a stable metabolic dynamic model of gastric cancer cells was established via a large-scale metabolic network dynamic modeling method in terms of a potential landscape description of stochastic and non-gradient systems. Based on the regulation of the model, a quantitative analysis was conducted to investigate the dynamic mechanism of serine/glycine metabolism affecting the proliferation of gastric cancer cells. We introduced random noise to the kinetic equations of the general metabolic network, and applied stochastic kinetic decomposition to obtain the Lyapunov function of the metabolic network parameter space. A stable metabolic network was achieved by further reducing the change in the Lyapunov function tied to the stochastic fluctuations. ResultsDespite the unavailability of a large number of dynamic parameters, we were able to successfully construct a dynamic model for the metabolic network in gastric cancer cells. When extracellular serine is available, the model preferentially consumes serine. In addition, when the conversion rate of glycine to serine increases, the model significantly upregulates the steady-state fluxes of S-adenosylmethionine (SAM) and S-adenosyl homocysteine (SAH). ConclusionIn this paper, we provide evidence supporting the preferential uptake of serine by gastric cancer cells and the important role of serine/glycine conversion rate in SAM generation, which may affect the proliferation ability of gastric cancer cells by regulating the cellular methylation process. This provides a new idea and direction for targeted cancer therapy based on serine/glycine metabolism.
3.New perspectives on the therapeutic potential of quercetin in non-communicable diseases:Targeting Nrf2 to counteract oxidative stress and inflammation
Zhang LI ; Xu LI-YUE ; Tang FEI ; Liu DONG ; Zhao XIAO-LAN ; Zhang JING-NAN ; Xia JIA ; Wu JIAO-JIAO ; Yang YU ; Peng CHENG ; Ao HUI
Journal of Pharmaceutical Analysis 2024;14(6):805-822
Non-communicable diseases(NCDs),including cardiovascular diseases,cancer,metabolic diseases,and skeletal diseases,pose significant challenges to public health worldwide.The complex pathogenesis of these diseases is closely linked to oxidative stress and inflammatory damage.Nuclear factor erythroid 2-related factor 2(Nrf2),a critical transcription factor,plays an important role in regulating antioxidant and anti-inflammatory responses to protect the cells from oxidative damage and inflammation-mediated injury.Therefore,Nrf2-targeting therapies hold promise for preventing and treating NCDs.Quercetin(Que)is a widely available flavonoid that has significant antioxidant and anti-inflammatory properties.It modulates the Nrf2 signaling pathway to ameliorate oxidative stress and inflammation.Que modulates mitochondrial function,apoptosis,autophagy,and cell damage biomarkers to regulate oxidative stress and inflammation,highlighting its efficacy as a therapeutic agent against NCDs.Here,we discussed,for the first time,the close association between NCD pathogenesis and the Nrf2 signaling pathway,involved in neurodegenerative diseases(NDDs),cardiovascular disease,cancers,organ damage,and bone damage.Furthermore,we reviewed the availability,pharmacokinetics,pharmaceutics,and therapeutic applica-tions of Que in treating NCDs.In addition,we focused on the challenges and prospects for its clinical use.Que represents a promising candidate for the treatment of NCDs due to its Nrf2-targeting properties.
4.Study on the bifid ribs of Tibetan population in Kangbei area based on multi-slice spiral CT
Yu-Lin ZHANG ; Ping AO ; Li ZHU ; Jiao HUANG ; Zhi-Gang XIU ; Mei-Mei YU ; Wei-Min LI
Journal of Regional Anatomy and Operative Surgery 2024;33(5):404-407
Objective To explore the incidence and imaging characteristics of bifid ribs of Tibetan population in Kangbei area by multi-slice spiral CT(MSCT),in order to provide imaging reference for clinical diagnosis and treatment.Methods The imaging data of 1 253 Tibetan patients(661 males and 592 females)in Kangbei area who underwent chest MSCT examination were retrospectively analyzed.The incidence of bifid ribs and its differences between genders and sides were counted.The location of bifid ribs,the morphological charac-teristics of the junction of bifid ribs and costal cartilage,and the change of adjacent intercostal space were observed.Results Among 1 253 patients with chest MSCT,57 patients had bifid ribs,with a total of 64 bifid ribs.The incidence of bifid ribs at the patient level was 4.55%,of which 51 cases had single bifid rib and 6 cases had multiple bifid ribs;the incidence of bifid ribs in male was 4.99%(33/661),the female was 4.05%(24/592),and the difference between genders was not statistically significant(P>0.05).The incidence of bifid ribs was 56.14%(32/57)on the right side,33.33%(19/57)on the left side,and 10.53%(6/57)on both sides,the differences between different sides were statistically significant(P<0.05).The bifid ribs were found in the 2nd to 8th ribs,mainly in the 3rd to 5th ribs.A total of 55(85.94%)junctions of bifid ribs and costal cartilage were obturator type,5(7.81%)junctions were incompletehole shape type,3(4.69%)junctions were double costal cartilage type and 1(1.56%)junction was other type;62(96.88%)junctions were narrow in the upper intercostal space.Conclusion The incidence of bifid ribs of the Tibetan population in Kangbei area is 4.55%,which mainly occurs in the 3rd to 5th ribs,and the obturator type is more common,with the upper intercostal space narrow.MSCT can make accurate diagnosis of bifid ribs and provide accurate imaging evaluation for clinical practice.
6.Robot-assisted single lung transplantation.
Wenjie JIAO ; Ronghua YANG ; Yandong ZHAO ; Nan GE ; Tong QIU ; Xiao SUN ; Yingzhi LIU ; Kun LI ; Zhiqiang LI ; Wencheng YU ; Yi QIN ; Ao LIU
Chinese Medical Journal 2023;136(3):362-364
7.Automatic determination of mandibular landmarks based on three-dimensional mandibular average model.
Zi Xiang GAO ; Yong WANG ; Ao Nan WEN ; Yu Jia ZHU ; Qing Zhao QIN ; Yun ZHANG ; Jing WANG ; Yi Jiao ZHAO
Journal of Peking University(Health Sciences) 2023;55(1):174-180
OBJECTIVE:
To explore an efficient and automatic method for determining the anatomical landmarks of three-dimensional(3D) mandibular data, and to preliminarily evaluate the performance of the method.
METHODS:
The CT data of 40 patients with normal craniofacial morphology were collected (among them, 30 cases were used to establish the 3D mandibular average model, and 10 cases were used as test datasets to validate the performance of this method in determining the mandibular landmarks), and the 3D mandibular data were reconstructed in Mimics software. Among the 40 cases of mandibular data after the 3D reconstruction, 30 cases that were more similar to the mean value of Chinese mandibular features were selected, and the size of the mandibular data of 30 cases was normalized based on the Procrustes analysis algorithm in MATLAB software. Then, in the Geomagic Wrap software, the 3D mandibular average shape model of the above 30 mandibular data was constructed. Through symmetry processing, curvature sampling, index marking and other processing procedures, a 3D mandible structured template with 18 996 semi-landmarks and 19 indexed mandibular anatomical landmarks were constructed. The open source non-rigid registration algorithm program Meshmonk was used to match the 3D mandible template constructed above with the tested patient's 3D mandible data through non-rigid deformation, and 19 anatomical landmark positions of the patient's 3D mandible data were obtained. The accuracy of the research method was evaluated by comparing the distance error of the landmarks manually marked by stomatological experts with the landmarks marked by the method of this research.
RESULTS:
The method of this study was applied to the data of 10 patients with normal mandibular morphology. The average distance error of 19 landmarks was 1.42 mm, of which the minimum errors were the apex of the coracoid process [right: (1.01±0.44) mm; left: (0.56±0.14) mm] and maximum errors were the anterior edge of the lowest point of anterior ramus [right: (2.52±0.95) mm; left: (2.57±1.10) mm], the average distance error of the midline landmarks was (1.15±0.60) mm, and the average distance error of the bilateral landmarks was (1.51±0.67) mm.
CONCLUSION
The automatic determination method of 3D mandibular anatomical landmarks based on 3D mandibular average shape model and non-rigid registration algorithm established in this study can effectively improve the efficiency of automatic labeling of 3D mandibular data features. The automatic determination of anatomical landmarks can basically meet the needs of oral clinical applications, and the labeling effect of deformed mandible data needs to be further tested.
Humans
;
Imaging, Three-Dimensional/methods*
;
Mandible/diagnostic imaging*
;
Software
;
Algorithms
;
Anatomic Landmarks/anatomy & histology*
8.Preliminary study on three-dimensional morphological reconstruction method for external nose defect based on three-dimensional face template.
Ao Nan WEN ; Yong WANG ; Hong Qiang YE ; Zi Xiang GAO ; Yu Jia ZHU ; Qing Zhap QIN ; Hui Zhen HU ; Yun Song LIU ; Yi Jiao ZHAO
Chinese Journal of Stomatology 2023;58(5):414-421
Objective: To provide a new solution for the digital design of nasal prostheses, this study explores the three-dimensional (3D) facial morphology completion method for external nasal defects based on the non-rigid registration process of 3D face template. Methods: A total of 20 male patients with tooth defect and dentition defect who visited the Department of Prosthodontics, Peking University School and Hospital of Stomatology from June to December 2022 were selected, age 18-45 years old. The original 3D facial data of patients were collected, and the 3D facial data of the external nose defect was constructed in Geomagic Wrap 2021 software. Using the structured 3D face template data constructed in the previous research of the research group, the 3D face template was deformed and registered to the 3D facial data of external nose defect (based on the morphology of non-defective area) by non-rigid registration algorithm (MeshMonk program), and the personalized deformed data of the 3D face template was obtained, as the complemented facial 3D data. Based on the defect boundary of the 3D facial data of the external nose defect, the complemented external nose 3D data can be cut out from the complemented facial 3D data. Then the nasofacial angle and nasolabial angle of the complemented facial 3D data and the original 3D facial data was compared and analyzed, the ratio between the nose length and mid-face height, nose width and medial canthal distance of the complemented facial 3D data was measured, the edge fit between the edge curve of the complemented external nose 3D data and the defect edge curve of the 3D facial data of external nose defect was evaluated, and the morphological difference of the nose between the complemented external nose 3D data and the original 3D facial data was analyzed. Results: There was no significant statistically difference (t=-0.23, P=0.823; Z=-1.72, P=0.086) in the nasofacial angle (28.2°±2.9°, 28.4°±3.5° respectively) and nasolabial angle [95.4°(19.2°), 99.9°(9.5°) respectively] between the 20 original 3D facial data and the complemented facial 3D data. The value of the ratio of nose length to mid-face height in the complemented facial 3D data was 0.63±0.03, and the value of the ratio of nose width to medial canthal distance was 1.07±0.08. The curve deviation (root mean square value) between the edge curve of the complemented external nose 3D data and the defect edge curve of the 3D facial data of external nose defect was (0.37±0.09) mm, the maximum deviation was (1.14±0.32) mm, and the proportion of the curve deviation value within±1 mm was (97±3)%. The distance of corresponding nose landmarks between the complemented facial 3D data and the original 3D facial data were respectively, Nasion: [1.52(1.92)] mm; Pronasale: (3.27±1.21) mm; Subnasale: (1.99±1.09) mm; Right Alare: (2.64±1.34) mm; Left Alare: (2.42± 1.38) mm. Conclusions: The method of 3D facial morphology completion of external nose defect proposed in this study has good feasibility. The constructed complemented external nose 3D data has good facial coordination and edge fit, and the morphology is close to the nose morphology of the original 3D facial data.
9.The design method of the digital sequential tooth-sectioning guide for the extraction of mandibular impacted third molars.
Zi Xiang GAO ; Yi Jiao ZHAO ; Yu Jia ZHU ; Ning XIAO ; Ao Nan WEN ; Wei ZHOU ; Bo Chun MAO ; Yun ZHANG ; Wei QI ; Yong WANG
Chinese Journal of Stomatology 2023;58(5):435-441
Objective: To explore a method for digitally designing and fabricating a sequential tooth-sectioning guide that can assist in the extraction of mandibular horizontal impacted third molars, preliminarily evaluate its feasibility and provide a reference for clinical application. Methods: Twenty patients with mandibular low level impacted third molars who visited the Department of General Dentistry, Peking University School and Hospital of Stomatology from March 2021 to January 2022 were selected. Cone-beam CT showed direct contact between the roots and mandibular canal, and full range impressions of the patients' intraoral teeth were taken and optical scans of the dental model were performed. The patients' cone-beam CT data and optical scan data were reconstructed in three dimensions, anatomical structure extraction, registration fusion, and the design of the structure of the guide (including crown-sectioning guide and root-sectioning guide) by Mimics 24.0, Geomagic Wrap 2021, and Magics 21.0 software, and then the titanium guide was three dimension printed, and the guide was tried on the dental model. After confirmation, the guide was used to assist the dentist in the operation. We observed whether the guide was in place, the number of tooth splitting, the matching of tooth splitting with the preoperative design, the operation time, and whether there were any complications. Results: In this study, 20 sectioning guides were successfully printed, all of them were well fitted in the patients' mouth, the average number of section was 3.4 times, the tooth parts was better matched with the preoperative design, and the average operative time of the guides was (29.2±9.8) minutes without complications such as perforation of the bone cortex. Conclusions: The use of sequential sectioning guides to assist in the extraction of mandibular impacted third molars was initially validated to accurately replicate the preoperative sectioning design, and is expected to provide a digital solution to improve surgical precision and ensure safety. Further studies with larger sample sizes are needed to evaluate its accuracy and safety.
10.Study on the method of automatically determining maxillary complex landmarks based on non-rigid registration algorithms.
Zi Xiang GAO ; Jing WANG ; Ao Nan WEN ; Yu Jia ZHU ; Qing Zhao QIN ; Yong WANG ; Yi Jiao ZHAO
Chinese Journal of Stomatology 2023;58(6):554-560
Objective: To explore an automatic landmarking method for anatomical landmarks in the three-dimensional (3D) data of the maxillary complex and preliminarily evaluate its reproducibility and accuracy. Methods: From June 2021 to December 2022, spiral CT data of 31 patients with relatively normal craniofacial morphology were selected from those who visited the Department of Oral and Maxillofacial Surgery, Peking University School and Hospital of Stomatology. The sample included 15 males and 16 females, with the age of (33.3±8.3) years. The maxillary complex was reconstructed in 3D using Mimics software, and the resulting 3D data of the maxillary complex was mesh-refined using Geomagic software. Two attending physicians and one associate chief physician manually landmarked the 31 maxillary complex datasets, determining 24 anatomical landmarks. The average values of the three expert landmarking results were used as the expert-defined landmarks. One case that conformed to the average 3D morphological characteristics of healthy individuals' craniofacial bones was selected as the template data, while the remaining 30 cases were used as target data. The open-source MeshMonk program (a non-rigid registration algorithm) was used to perform an initial alignment of the template and target data based on 4 landmarks (nasion, left and right zygomatic arch prominence, and anterior nasal spine). The template data was then deformed to the shape of the target data using a non-rigid registration algorithm, resulting in the deformed template data. Based on the unchanged index property of homonymous landmarks before and after deformation of the template data, the coordinates of each landmark in the deformed template data were automatically retrieved as the automatic landmarking coordinates of the homonymous landmarks in the target data, thus completing the automatic landmarking process. The automatic landmarking process for the 30 target data was repeated three times. The root-mean-square distance (RMSD) of the dense corresponding point pairs (approximately 25 000 pairs) between the deformed template data and the target data was calculated as the deformation error of the non-rigid registration algorithm, and the intra-class correlation coefficient (ICC) of the deformation error in the three repetitions was analyzed. The linear distances between the automatic landmarking results and the expert-defined landmarks for the 24 anatomical landmarks were calculated as the automatic landmarking errors, and the ICC values of the 3D coordinates in the three automatic landmarking repetitions were analyzed. Results: The average three-dimensional deviation (RMSD) between the deformed template data and the corresponding target data for the 30 cases was (0.70±0.09) mm, with an ICC value of 1.00 for the deformation error in the three repetitions of the non-rigid registration algorithm. The average automatic landmarking error for the 24 anatomical landmarks was (1.86±0.30) mm, with the smallest error at the anterior nasal spine (0.65±0.24) mm and the largest error at the left oribital (3.27±2.28) mm. The ICC values for the 3D coordinates in the three automatic landmarking repetitions were all 1.00. Conclusions: This study established an automatic landmarking method for three-dimensional data of the maxillary complex based on a non-rigid registration algorithm. The accuracy and repeatability of this method for landmarking normal maxillary complex 3D data were relatively good.
Male
;
Female
;
Humans
;
Adult
;
Imaging, Three-Dimensional/methods*
;
Reproducibility of Results
;
Algorithms
;
Software
;
Tomography, Spiral Computed
;
Anatomic Landmarks/anatomy & histology*

Result Analysis
Print
Save
E-mail