1.Diagnostic yield of fine needle aspiration with simultaneous core needle biopsy for thyroid nodules
Mohammad Ali HASANNIA ; Ramin POURGHORBAN ; Hoda ASEFI ; Amir ARIA ; Elham NAZAR ; Hojat EBRAHIMINIK ; Alireza MOHAMADIAN
Journal of Pathology and Translational Medicine 2025;59(3):180-187
Background:
Fine needle aspiration (FNA) is a widely utilized technique for assessing thyroid nodules; however, its inherent non-diagnostic rate poses diagnostic challenges. The present study aimed to evaluate and compare the diagnostic efficacy of FNA, core needle biopsy (CNB), and their combined application in the assessment of thyroid nodules.
Methods:
A total of 56 nodules from 50 patients was analyzed using both FNA and simultaneous CNB. The ultrasound characteristics were categorized according to the American College of Radiology Thyroid Imaging Reporting and Data Systems classification system. The study compared the sensitivity, specificity, and accuracy of FNA, CNB, and the combination of the two techniques.
Results:
The concordance between FNA and CNB was notably high, with a kappa coefficient of 0.837. The sensitivity for detecting thyroid malignancy was found to be 25.0% for FNA, 66.7% for CNB, and 83.3% for the combined FNA/CNB approach, with corresponding specificities of 84.6%, 97.4%, and 97.4%. The accuracy of the FNA/CNB combination was the highest at 94.1%.
Conclusions
The findings of this study indicate that both CNB and the FNA/CNB combination offer greater diagnostic accuracy for thyroid malignancy compared to FNA alone, with no significant complications reported. Integrating CNB with FNA findings may enhance management strategies and treatment outcomes for patients with thyroid nodules.
2.Diagnostic yield of fine needle aspiration with simultaneous core needle biopsy for thyroid nodules
Mohammad Ali HASANNIA ; Ramin POURGHORBAN ; Hoda ASEFI ; Amir ARIA ; Elham NAZAR ; Hojat EBRAHIMINIK ; Alireza MOHAMADIAN
Journal of Pathology and Translational Medicine 2025;59(3):180-187
Background:
Fine needle aspiration (FNA) is a widely utilized technique for assessing thyroid nodules; however, its inherent non-diagnostic rate poses diagnostic challenges. The present study aimed to evaluate and compare the diagnostic efficacy of FNA, core needle biopsy (CNB), and their combined application in the assessment of thyroid nodules.
Methods:
A total of 56 nodules from 50 patients was analyzed using both FNA and simultaneous CNB. The ultrasound characteristics were categorized according to the American College of Radiology Thyroid Imaging Reporting and Data Systems classification system. The study compared the sensitivity, specificity, and accuracy of FNA, CNB, and the combination of the two techniques.
Results:
The concordance between FNA and CNB was notably high, with a kappa coefficient of 0.837. The sensitivity for detecting thyroid malignancy was found to be 25.0% for FNA, 66.7% for CNB, and 83.3% for the combined FNA/CNB approach, with corresponding specificities of 84.6%, 97.4%, and 97.4%. The accuracy of the FNA/CNB combination was the highest at 94.1%.
Conclusions
The findings of this study indicate that both CNB and the FNA/CNB combination offer greater diagnostic accuracy for thyroid malignancy compared to FNA alone, with no significant complications reported. Integrating CNB with FNA findings may enhance management strategies and treatment outcomes for patients with thyroid nodules.
3.Diagnostic yield of fine needle aspiration with simultaneous core needle biopsy for thyroid nodules
Mohammad Ali HASANNIA ; Ramin POURGHORBAN ; Hoda ASEFI ; Amir ARIA ; Elham NAZAR ; Hojat EBRAHIMINIK ; Alireza MOHAMADIAN
Journal of Pathology and Translational Medicine 2025;59(3):180-187
Background:
Fine needle aspiration (FNA) is a widely utilized technique for assessing thyroid nodules; however, its inherent non-diagnostic rate poses diagnostic challenges. The present study aimed to evaluate and compare the diagnostic efficacy of FNA, core needle biopsy (CNB), and their combined application in the assessment of thyroid nodules.
Methods:
A total of 56 nodules from 50 patients was analyzed using both FNA and simultaneous CNB. The ultrasound characteristics were categorized according to the American College of Radiology Thyroid Imaging Reporting and Data Systems classification system. The study compared the sensitivity, specificity, and accuracy of FNA, CNB, and the combination of the two techniques.
Results:
The concordance between FNA and CNB was notably high, with a kappa coefficient of 0.837. The sensitivity for detecting thyroid malignancy was found to be 25.0% for FNA, 66.7% for CNB, and 83.3% for the combined FNA/CNB approach, with corresponding specificities of 84.6%, 97.4%, and 97.4%. The accuracy of the FNA/CNB combination was the highest at 94.1%.
Conclusions
The findings of this study indicate that both CNB and the FNA/CNB combination offer greater diagnostic accuracy for thyroid malignancy compared to FNA alone, with no significant complications reported. Integrating CNB with FNA findings may enhance management strategies and treatment outcomes for patients with thyroid nodules.
4.Effects of Chromium Picolinate Supplementation on Cardiometabolic Biomarkers in Patients with Type 2 Diabetes Mellitus: a Randomized Clinical Trial
Aria Tavakoli TALAB ; Hadi ABDOLLAHZAD ; Seyyed Mustafa NACHVAK ; Yahya PASDAR ; Shahryar EGHTESADI ; Azimeh IZADI ; Mir Amir AGHDASHI ; Mohammad Reza Mohammad Hossseini AZAR ; Sedighe MORADI ; Behzad MEHAKI ; Shima MORADI
Clinical Nutrition Research 2020;9(2):97-106
Type 2 diabetes mellitus (T2DM) is a serious public health problem accompanies with several complications. This study was conducted to evaluate the effects of chromium picolinate (CrPic) supplementation on the glycemic status and lipid profile in patients with T2DM. The patients with T2DM (n = 52) were randomly allocated into 2 groups. One group received 400 μg CrPic per day and the other group took placebo; the intervention duration was 8 weeks. Anthropometric indices and metabolic factors were measured at the beginning, and at end of the study. The patients were recommended not to change their normal diet, life style and medication. No significant changes were observed for weight, body mass index, and fasting blood glucose (FBG) in both groups; while intra-groups changes in homeostatic model assessment for insulin resistance (HOMA-IR) value was significant (p < 0.05). Results of analysis of covariance showed that there were significance differences between groups in total cholesterol, low density lipoprotein cholesterol and HOMA-IR at the end of the intervention adjusting for baseline levels (p = 0.035, 0.030 and < 0.001, respectively). In this study, oral supplementation with 400 μg CrPic for eight weeks did not alter FBG concentration as well as anthropometric parameters in individuals with T2DM. However, the modest beneficial effects of chromium supplementation on insulin resistance as indicated by HOMA-IR and lipid profile were found.
5.Mirror Therapy as an Alternative Treatment for Phantom Limb Pain: A Short Literature Review.
Farshad HASANZADEH KIABI ; Mohammad Reza HABIBI ; Aria SOLEIMANI ; Amir EMAMI ZEYDI
The Korean Journal of Pain 2013;26(3):309-311
No abstract available.
Phantom Limb
6.Can Vitamin C Be Used as an Adjuvant for Managing Postoperative Pain? A Short Literature Review.
Farshad HASANZADEH KIABI ; Aria SOLEIMANI ; Mohammad Reza HABIBI ; Amir EMAMI ZEYDI
The Korean Journal of Pain 2013;26(2):209-210
No abstract available.
Ascorbic Acid
;
Vitamins

Result Analysis