1.Evolution and development: engine-driven endodontic rotary nickel-titanium instruments.
International Journal of Oral Science 2022;14(1):12-12
Various engine-driven NiTi endodontic files have been indispensable and efficient tools in cleaning and shaping of root canals for practitioners. In this review, we introduce the relative terms and conceptions of NiTi file, including crystal phase composition, the design of the cutting part, types of separation. This review also analysis the main improvement and evolution of different generations of engine-driven nickel-titanium instruments in the past 20 years in the geometric design, manufacturing surface treatment such as electropolishing, thermal treatment, metallurgy. And the variety of motion modes of NiTi files to improve resistance to torsional failure were also discussed. Continuous advancements by the designers, provide better balance between shaping efficiency and resistance to of NiTi systems. In clinical practice an appropriate system should be selected based on the anatomy of the root canal, instrument characteristics, and operators' experience.
Dental Alloys/chemistry*
;
Dental Instruments
;
Equipment Design
;
Nickel/chemistry*
;
Root Canal Preparation
;
Titanium/chemistry*
2.Bionic mechanical design and 3D printing of novel porous Ti6Al4V implants for biomedical applications.
Wen-Ming PENG ; Yun-Feng LIU ; Xian-Feng JIANG ; Xing-Tao DONG ; Janice JUN ; Dale A BAUR ; Jia-Jie XU ; Hui PAN ; Xu XU
Journal of Zhejiang University. Science. B 2019;20(8):647-659
In maxillofacial surgery, there is a significant need for the design and fabrication of porous scaffolds with customizable bionic structures and mechanical properties suitable for bone tissue engineering. In this paper, we characterize the porous Ti6Al4V implant, which is one of the most promising and attractive biomedical applications due to the similarity of its modulus to human bones. We describe the mechanical properties of this implant, which we suggest is capable of providing important biological functions for bone tissue regeneration. We characterize a novel bionic design and fabrication process for porous implants. A design concept of "reducing dimensions and designing layer by layer" was used to construct layered slice and rod-connected mesh structure (LSRCMS) implants. Porous LSRCMS implants with different parameters and porosities were fabricated by selective laser melting (SLM). Printed samples were evaluated by microstructure characterization, specific mechanical properties were analyzed by mechanical tests, and finite element analysis was used to digitally calculate the stress characteristics of the LSRCMS under loading forces. Our results show that the samples fabricated by SLM had good structure printing quality with reasonable pore sizes. The porosity, pore size, and strut thickness of manufactured samples ranged from (60.95± 0.27)% to (81.23±0.32)%, (480±28) to (685±31) μm, and (263±28) to (265±28) μm, respectively. The compression results show that the Young's modulus and the yield strength ranged from (2.23±0.03) to (6.36±0.06) GPa and (21.36±0.42) to (122.85±3.85) MPa, respectively. We also show that the Young's modulus and yield strength of the LSRCMS samples can be predicted by the Gibson-Ashby model. Further, we prove the structural stability of our novel design by finite element analysis. Our results illustrate that our novel SLM-fabricated porous Ti6Al4V scaffolds based on an LSRCMS are a promising material for bone implants, and are potentially applicable to the field of bone defect repair.
Alloys
;
Bionics
;
Bone Substitutes/chemistry*
;
Bone and Bones/pathology*
;
Compressive Strength
;
Elastic Modulus
;
Finite Element Analysis
;
Humans
;
Lasers
;
Materials Testing
;
Maxillofacial Prosthesis Implantation
;
Porosity
;
Pressure
;
Printing, Three-Dimensional
;
Prostheses and Implants
;
Prosthesis Design
;
Stress, Mechanical
;
Surgery, Oral/instrumentation*
;
Tissue Engineering/methods*
;
Titanium/chemistry*
3.Osteoblast integration of dental implant materials after challenge by sub-gingival pathogens: a co-culture study in vitro.
Bingran ZHAO ; ; Minie RUSTEMA-ABBING ; Henk J BUSSCHER ; Yijin REN
International Journal of Oral Science 2015;7(4):250-258
Sub-gingival anaerobic pathogens can colonize an implant surface to compromise osseointegration of dental implants once the soft tissue seal around the neck of an implant is broken. In vitro evaluations of implant materials are usually done in monoculture studies involving either tissue integration or bacterial colonization. Co-culture models, in which tissue cells and bacteria battle simultaneously for estate on an implant surface, have been demonstrated to provide a better in vitro mimic of the clinical situation. Here we aim to compare the surface coverage by U2OS osteoblasts cells prior to and after challenge by two anaerobic sub-gingival pathogens in a co-culture model on differently modified titanium (Ti), titanium-zirconium (TiZr) alloys and zirconia surfaces. Monoculture studies with either U2OS osteoblasts or bacteria were also carried out and indicated significant differences in biofilm formation between the implant materials, but interactions with U2OS osteoblasts were favourable on all materials. Adhering U2OS osteoblasts cells, however, were significantly more displaced from differently modified Ti surfaces by challenging sub-gingival pathogens than from TiZr alloys and zirconia variants. Combined with previous work employing a co-culture model consisting of human gingival fibroblasts and supra-gingival oral bacteria, results point to a different material selection to stimulate the formation of a soft tissue seal as compared to preservation of osseointegration under the unsterile conditions of the oral cavity.
Acid Etching, Dental
;
methods
;
Alloys
;
chemistry
;
Bacterial Adhesion
;
physiology
;
Bacteriological Techniques
;
Biofilms
;
Cell Adhesion
;
physiology
;
Cell Culture Techniques
;
Cell Line, Tumor
;
Cell Movement
;
physiology
;
Ceramics
;
chemistry
;
Coculture Techniques
;
Dental Alloys
;
chemistry
;
Dental Etching
;
methods
;
Dental Implants
;
microbiology
;
Dental Materials
;
chemistry
;
Dental Polishing
;
methods
;
Humans
;
Osseointegration
;
physiology
;
Osteoblasts
;
physiology
;
Porphyromonas gingivalis
;
physiology
;
Prevotella intermedia
;
physiology
;
Surface Properties
;
Titanium
;
chemistry
;
Yttrium
;
chemistry
;
Zirconium
;
chemistry
4.Effect of colouring green stage zirconia on the adhesion of veneering ceramics with different thermal expansion coefficients.
Guliz AKTAS ; Erdal SAHIN ; Pekka VALLITTU ; Mutlu OZCAN ; Lippo LASSILA
International Journal of Oral Science 2013;5(4):236-241
This study evaluated the adhesion of zirconia core ceramics with their corresponding veneering ceramics, having different thermal expansion coefficients (TECs), when zirconia ceramics were coloured at green stage. Zirconia blocks (N=240; 6 mm×7 mm×7 mm) were manufactured from two materials namely, ICE Zirconia (Group 1) and Prettau Zirconia (Group 2). In their green stage, they were randomly divided into two groups. Half of the specimens were coloured with colouring liquid (shade A2). Three different veneering ceramics with different TEC (ICE Ceramic, GC Initial Zr and IPS e.max Ceram) were fired on both coloured and non-coloured zirconia cores. Specimens of high noble alloys (Esteticor Plus) veneered with ceramic (VM 13) (n=16) acted as the control group. Core-veneer interface of the specimens were subjected to shear force in the Universal Testing Machine (0.5 mm⋅min(-1)). Neither the zirconia core material (P=0.318) nor colouring (P=0.188) significantly affected the results (three-way analysis of variance, Tukey's test). But the results were significantly affected by the veneering ceramic (P=0.000). Control group exhibited significantly higher mean bond strength values (45.7±8) MPa than all other tested groups ((27.1±4.1)-(39.7±4.7) and (27.4±5.6)-(35.9±4.7) MPa with and without colouring, respectively) (P<0.001). While in zirconia-veneer test groups, predominantly mixed type of failures were observed with the veneering ceramic covering <1/3 of the substrate surface, in the metal-ceramic group, veneering ceramic was left adhered >1/3 of the metal surface. Colouring zirconia did not impair adhesion of veneering ceramic, but veneering ceramic had a significant influence on the core-veneer adhesion. Metal-ceramic adhesion was more reliable than all zirconia-veneer ceramics tested.
Adhesiveness
;
Ceramics
;
chemistry
;
Color
;
Dental Bonding
;
Dental Materials
;
chemistry
;
Dental Porcelain
;
chemistry
;
Dental Stress Analysis
;
instrumentation
;
Dental Veneers
;
Gold Alloys
;
chemistry
;
Humans
;
Materials Testing
;
Metal Ceramic Alloys
;
chemistry
;
Prosthesis Coloring
;
Stress, Mechanical
;
Surface Properties
;
Thermodynamics
;
Yttrium
;
chemistry
;
Zirconium
;
chemistry
5.Tooth wear against ceramic crowns in posterior region: a systematic literature review.
International Journal of Oral Science 2013;5(4):183-190
The objective of this systematic review was to assess tooth wear against ceramic crowns in posterior region in vitro and in vivo. An electronic PubMed search was conducted to identify studies on tooth wear against ceramic crowns in posterior region. The selected studies were analyzed in regard to type of crowns, natural antagonist, measuring protocol and outcome. From a yield of 1 000 titles, 43 articles were selected for full-text analysis; finally, no in vitro and only five in vivo studies met the inclusion criteria. As there is heterogeneity in design, used measuring method, ceramics and analysis-form, a meta-analysis was not possible. Results of these studies are very controversial which makes a scientifically valid comparison impossible. This review indicated that some all-ceramic crowns are as wear friendly as metal-ceramic crowns. Up to now, it has been impossible to associate tooth wear with any specific causal agent. The role of ceramic surface treatment that might be responsible for the changing in rate of tooth wear seems undetermined as yet through clinical trials. The literature reveals that studies on this topic are subject to a substantial amount of bias. Therefore, additional clinical studies, properly designed to diminish bias, are warranted.
Crowns
;
Dental Enamel
;
pathology
;
Dental Porcelain
;
chemistry
;
classification
;
Humans
;
Metal Ceramic Alloys
;
chemistry
;
Surface Properties
;
Tooth Crown
;
pathology
;
Tooth Wear
;
etiology
6.Urinary levels of nickel and chromium associated with dental restoration by nickel-chromium based alloys.
Bo CHEN ; Gang XIA ; Xin-Ming CAO ; Jue WANG ; Bi-Yao XU ; Pu HUANG ; Yue CHEN ; Qing-Wu JIANG
International Journal of Oral Science 2013;5(1):44-48
This paper aims to investigate if the dental restoration of nickel-chromium based alloy (Ni-Cr) leads to the enhanced excretions of Ni and Cr in urine. Seven hundred and ninety-five patients in a dental hospital had single or multiple Ni-Cr alloy restoration recently and 198 controls were recruited to collect information on dental restoration by questionnaire and clinical examination. Urinary concentrations of Ni and Cr from each subject were measure by graphite furnace atomic absorption spectrometry. Compared to the control group, the urinary level of Ni was significantly higher in the patient group of <1 month of the restoration duration, among which higher Ni excretions were found in those with either a higher number of teeth replaced by dental alloys or a higher index of metal crown not covered with the porcelain. Urinary levels of Cr were significantly higher in the three patient groups of <1, 1 to <3 and 3 to <6 months, especially in those with a higher metal crown exposure index. Linear curve estimations showed better relationships between urinary Ni and Cr in patients within 6-month groups. Our data suggested significant increased excretions of urinary Ni and Cr after dental restoration. Potential short- and long-term effects of Ni-Cr alloy restoration need to be investigated.
Adult
;
Chromium
;
urine
;
Chromium Alloys
;
chemistry
;
Creatinine
;
urine
;
Crowns
;
Dental Porcelain
;
chemistry
;
Female
;
Humans
;
Male
;
Metal Ceramic Alloys
;
chemistry
;
Middle Aged
;
Nickel
;
urine
;
Spectrophotometry, Atomic
;
Surface Properties
;
Time Factors
7.In vivo experimental study on MAO-ZK60 magnesium alloy bio-safety and degradation.
Yi YIN ; Qiang ZHANG ; Zheng-Rong QI ; Yan WANG
China Journal of Orthopaedics and Traumatology 2013;26(5):423-428
OBJECTIVETo investigate the tissue toxicity and degradation of ZK60 magnesium alloy with micro-arc oxidation coatings (MAO-ZK60), in order to discuss the possibility of its potential application for orthopedic implantation.
METHODSEighteen Sprague-Dawley rats were randomized equally to three groups of A, B, C. MAO-ZK60 sticks were implanted in the femoral condyles of rats in group A (experimental group). Sticks of ZK60 magnesium alloy without any surface treatment (ZK60) were implanted in the femoral condyles of rats in group B (control group). The poly L-lactic acid (PLLA) sticks were implanted in the femoral condyles of rats in group C (control group). The changes of blood bio-chemical indexes of different groups were observed and compared. All the rats were sacrificed at 12 weeks and histological observation of liver and kidney were carried out to evaluate the hepatic and renal toxicity. Micro-CT was used to evaluate the degradation of the implants and to observe the bone-implant interface. GEHC MicroView software was operated to calculate the volume variation of magnesium alloy.
RESULTSThere was no apparent biochemical index change with time in each group, and there was no significant change among each group. No significant pathology change of liver and kidney was detected among three groups. By using a micro-CT, a gap was found on the bone-implant interface at 4 weeks after implantation in group A, which decreased gradually at 8 weeks after implantation and continued to decrease at 12 weeks after implantation. A good combination between bone and implant formed at 12 weeks after implantation. Group A has less change of volume with time than group B (P < 0.05).
CONCLUSIONZK60 magnesium alloy with micro-arc oxidation coatings is safe in vivo. It has higher corrosion resistance than ZK60 magnesium alloy without any surface treatment.
Alloys ; chemistry ; metabolism ; toxicity ; Animals ; Magnesium ; chemistry ; Male ; Rats ; Rats, Sprague-Dawley
9.The investigation of nickel dissolution from nitinol under different extraction conditions in biological tests.
Xiantao WEN ; Xueying HE ; Jian LI ; Juli TANG ; Yongfu HUANG
Chinese Journal of Medical Instrumentation 2013;37(2):129-131
The dissolution of nickel from nitinol alloy under different extraction conditions was investigated when biological tests of nitinol medical devices were carried out. It discussed the equivalence of these extraction conditions and found the best extraction conditions. In the experiment, two brands of nitinol were chosen and extracted under different extraction conditions according to GB/T 16886-12. Plasma emission spectrometer was used to analyse the concentration of nickel in extract liquid. The results show that there is no equivalence among these extraction conditions for nitinol materials. And it is suggested that (37 +/- 1) degree C, (72 +/- 2) h could be used as normal extraction condition and (70 +/- 2) degrees C, (24 +/- 2) h as accelerated extraction condition.
Alloys
;
chemistry
;
Biocompatible Materials
;
Materials Testing
;
Nickel
;
chemistry
;
Temperature
;
Titanium
10.Influence of masticatory fatigue on the fracture resistance of the pulpless teeth restored with quartz-fiber post-core and crown.
Er-Min NIE ; Xia-Yun CHEN ; Chun-Yuan ZHANG ; Li-Li QI ; Ying-He HUANG
International Journal of Oral Science 2012;4(4):218-220
To investigate whether masticatory fatigue affects the fracture resistance and pattern of lower premolars restored with quartz-fiber post-core and full crown, 44 single rooted lower premolars recently extracted from orthodontic patients were divided into two groups of 22 each. The crowns of all teeth were removed and endodontically treated and then restored with quartz-fiber post-core and full crown. Twenty-two teeth in one group were selected randomly and circularly loaded at 45° to the long axis of the teeth of 127.4 N at a 6 Hz frequency, and the other group was not delivered to cyclic loading and considered as control. Subsequently, all teeth in two groups were continually loaded to fail at 45° to the long axis of the teeth at a crosshead speed of 1 mm⋅min(-1). The mean destructive force values were (733.88±254.99) and (869.14±280.26) N for the experimental and the control group, respectively, and no statistically significant differences were found between two groups (P>0.05). Bevel fracture and horizontal fracture in the neck of root were the major fracture mode of the specimens. Under the circumstances of this study, it seems that cyclic loading does not affect the fracture strength and pattern of the quartz-fiber post-core-crown complex.
Acid Etching, Dental
;
methods
;
Adult
;
Bicuspid
;
Bite Force
;
Chromium Alloys
;
chemistry
;
Crowns
;
Dental Prosthesis Design
;
Dental Restoration Failure
;
Dental Stress Analysis
;
instrumentation
;
Humans
;
Materials Testing
;
Methacrylates
;
chemistry
;
Phosphoric Acids
;
chemistry
;
Post and Core Technique
;
instrumentation
;
Quartz
;
chemistry
;
Resin Cements
;
chemistry
;
Stress, Mechanical
;
Tooth Fractures
;
physiopathology
;
Tooth Root
;
injuries
;
Tooth, Nonvital
;
rehabilitation

Result Analysis
Print
Save
E-mail