1.Targeting FAPα-positive lymph node metastatic tumor cells suppresses colorectal cancer metastasis.
Shuran FAN ; Ming QI ; Qi QI ; Qun MIAO ; Lijuan DENG ; Jinghua PAN ; Shenghui QIU ; Jiashuai HE ; Maohua HUANG ; Xiaobo LI ; Jie HUANG ; Jiapeng LIN ; Wenyu LYU ; Weiqing DENG ; Yingyin HE ; Xuesong LIU ; Lvfen GAO ; Dongmei ZHANG ; Wencai YE ; Minfeng CHEN
Acta Pharmaceutica Sinica B 2024;14(2):682-697
Lymphatic metastasis is the main metastatic route for colorectal cancer, which increases the risk of cancer recurrence and distant metastasis. The properties of the lymph node metastatic colorectal cancer (LNM-CRC) cells are poorly understood, and effective therapies are still lacking. Here, we found that hypoxia-induced fibroblast activation protein alpha (FAPα) expression in LNM-CRC cells. Gain- or loss-function experiments demonstrated that FAPα enhanced tumor cell migration, invasion, epithelial-mesenchymal transition, stemness, and lymphangiogenesis via activation of the STAT3 pathway. In addition, FAPα in tumor cells induced extracellular matrix remodeling and established an immunosuppressive environment via recruiting regulatory T cells, to promote colorectal cancer lymph node metastasis (CRCLNM). Z-GP-DAVLBH, a FAPα-activated prodrug, inhibited CRCLNM by targeting FAPα-positive LNM-CRC cells. Our study highlights the role of FAPα in tumor cells in CRCLNM and provides a potential therapeutic target and promising strategy for CRCLNM.
2.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
3.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
4.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
5.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
6.Investigation of coordinated development between blood banks and apheresis plasma collection banks
Qun LIU ; Dunzhu GONGJUE ; Qian ZHANG ; Hui YE ; Hua SHEN ; Mingming QIAO ; Linwei LI ; Xingzhe ZHANG ; Xiangwen CHEN ; Liliang CHEN ; Yang LIU ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(8):927-932
Objective To explore the factors that affect the coordinated development of blood banks and apheresis plas-ma collection banks(hereinafter referred to as plasma banks),and explore feasible measures for the coordinated develop-ment of blood banks and plasma banks.Methods The blood information management system and blood source information management system were used to retrieve related data of blood and plasma donation from 9 cities in Shandong province from 2017 to 2021.The number of blood donors and plasma donors and the intersection of them were analyzed.The data analysis was performed using chi-square test,and a questionnaire survey was conducted to investigate the policies and information status,as well as expectations for coordinated development for blood and plasma donation.Results From 2017 to 2021,the total number of blood donors in 9 cities was higher than that of plasma donors,both have been increasing year by year,and the increase in plasma donors was significantly higher than that of blood donors(131.78%vs 23.90%,P<0.05).The inter-section proportion of blood and plasma donors had increased from 0.45%in 2017 to 1.04%in 2021,with an increase of 131.11%.Among the administrative regions where the participating blood and plasma banks located,94.2%have not re-leased relevant policy to promote the coordinated development of blood and plasma donation.The majority(63%)expected blood banks and plasma banks to be set at a distance more than 50 km apart.The top four functional requirements for the in-terconnection between blood banks and plasma banks management information system were blood test results(94.61%),ID number(87.54%),blood and plasma donation records(85.51%)and health consultation/examination results(82.15%).The top four elements of coordinated development between blood and plasma banks were policy support(96.25%),informa-tion networking(92.36%),top-level design(87.44%)and cultural construction(86.58%).Conclusion The number of donors who donate both blood(mainly whole blood)and plasma has been increasing year by year,which deserves our close attention.To achieve the coordinated development of blood donation and plasma donation,policy support is the most crucial and fundamental means.Establishment of a standard system and the share of blood and plasma donation information is neces-sary for blood informatization construction.It was critical to promote the coordinated development of blood and plasma dona-tion and ensure blood safety with improving legislation,formulating policies for coordinated development,strengthening top-level design,standardizing the publicity of blood and plasma donation and establishing the idea that blood and plasma dona-tion are equally honorable.
7.Qidan Granules Improves Insulin Resistance of Adipocytes by Promoting CTRP3 to Activate PI3K/AKT Signaling Pathway
Yue ZHANG ; Xu-Xi GUO ; Ren-Qun YE
Journal of Guangzhou University of Traditional Chinese Medicine 2024;41(6):1581-1588
Objective To explore the mechanism of Qidan Granules prevent insulin resistance(IR)in adipocytes.Methods The IR model of 3T3-L1 adipocytes was induced by palmitic acid culture method.The blank control group,model group,Qidan Granules low-,medium-and high-dose groups,Qidan Granules+C1q/TNF-related protein 3(CTRP3)siRNA group were set up.Determination of glucose consumption in cell supernatant was performed;the levels of tumor necrosis factor α(TNF-α)and interleukin 6(IL-6)in the cell supernatant were determined by enzyme-linked immunosorbent assay(ELISA).Real-time quantitative polymerase chain reaction(qRT-PCR)was used to detect the gene expressions of CTRP3,TNF-α,IL-6 and glucose transporter 4(GLUT4).The protein expressions and phosphorylation levels of CTRP3,phosphoinositide-3 kinase(PI3K)and protein kinase B(AKT)were detected by Western Blot.Results Compared with the model group,the glucose consumption was increased and tended to 70%-82%of the blank control group,TNF-α content was decreased by 25%-45%,IL-6 content was decreased by 40%-55%,GLUT4 mRNA expression level was increased by 50%,and mRNA and protein expression levels of CTRP3 were increased by 25%-40%in the medium-and high-dose groups of Qidan Granules(all P<0.05).Compared with the Qidan Granules group,the glucose consumption and GLUT4 mRNA expression level in the Qidan Granules+CTRP3 siRNA group were decreased by 33%and 27%,respectively,the contents of IL-6 and TNF-α were increased by 42%and 41%,respectively,and the protein expressions of p-PI3K and p-AKT were increased by 190%and 180%,respectively(all P<0.05).Conclusion Qidan Granules may improve the insulin sensitivity of IR 3T3-L1 adipocytes and improve IR of adipocytes by promoting CTRP3 expression to reduce inflammatory response and activate PI3K/AKT signaling pathway.
8.Changing trend and multivariate analysis of prevalence rates of healthcare-associated infection in a tertiary hospital for 10 years
Zi-Quan ZHOU ; Jin-Ai QIN ; Juan HUANG ; Yong-Kang YE ; Qun-Xiu GUO ; Lan-Lan LI ; Jing-Jing YA ; Ying-Hua ZHANG
Chinese Journal of Infection Control 2024;23(9):1135-1141
Objective To describe the changing trend and related factors of prevalence rates of healthcare-associa-ted infection(HAI)in a tertiary hospital in the past 10 years,and analyze the influencing factors for HAI.Methods A cross-sectional survey on HAI was conducted for 10 consecutive years from 2013 to 2022(one day was selected as the survey day each year),data were collected.The distribution and related factors of prevalence rates of HAI were analyzed by trend-x2 test and Pearson correlation coefficient.Multivariate logistic regression and multilayer percep-tron(MLP)models were constructed to analyze the independent effect and significance of factors.Results From 2013 to 2022,the prevalence rates of HAI ranged from 4.66%to 8.07%in this hospital,showing a linear upward trend.The proportions of ICU patients and utilization rate of central venous catheters within 2 days before the sur-vey showed linear upward trends,while the proportion of patients with urinary catheters within 2 days before the survey and proportion of patients undergoing surgery within 30 days before the survey decreased.The MLP model revealed that the top 3 important factors for HAI were length of hospital stay>10 days,admission in ICU,and in-dwelling central venous catheters within 2 days before the survey.Multivariate logistic regression model indicated that length of hospital stay>10 days,indwelling central venous catheters or urinary catheters within 2 days before the survey,surgery within 30 days before the survey,and admission in ICU were independent influencing factors for HAI.Conclusion The incidence of HAI in this hospital presents a linear increase in recent 10 years,the causes should be further analyzed and the direction of intervention should be determined through targeted surveillance.Adopting trend test statistical analysis method,logistic regression,MLP multi-factor model can further explore the data value of HAI prevalence survey.
9.Chinese expert consensus on blood support mode and blood transfusion strategies for emergency treatment of severe trauma patients (version 2024)
Yao LU ; Yang LI ; Leiying ZHANG ; Hao TANG ; Huidan JING ; Yaoli WANG ; Xiangzhi JIA ; Li BA ; Maohong BIAN ; Dan CAI ; Hui CAI ; Xiaohong CAI ; Zhanshan ZHA ; Bingyu CHEN ; Daqing CHEN ; Feng CHEN ; Guoan CHEN ; Haiming CHEN ; Jing CHEN ; Min CHEN ; Qing CHEN ; Shu CHEN ; Xi CHEN ; Jinfeng CHENG ; Xiaoling CHU ; Hongwang CUI ; Xin CUI ; Zhen DA ; Ying DAI ; Surong DENG ; Weiqun DONG ; Weimin FAN ; Ke FENG ; Danhui FU ; Yongshui FU ; Qi FU ; Xuemei FU ; Jia GAN ; Xinyu GAN ; Wei GAO ; Huaizheng GONG ; Rong GUI ; Geng GUO ; Ning HAN ; Yiwen HAO ; Wubing HE ; Qiang HONG ; Ruiqin HOU ; Wei HOU ; Jie HU ; Peiyang HU ; Xi HU ; Xiaoyu HU ; Guangbin HUANG ; Jie HUANG ; Xiangyan HUANG ; Yuanshuai HUANG ; Shouyong HUN ; Xuebing JIANG ; Ping JIN ; Dong LAI ; Aiping LE ; Hongmei LI ; Bijuan LI ; Cuiying LI ; Daihong LI ; Haihong LI ; He LI ; Hui LI ; Jianping LI ; Ning LI ; Xiying LI ; Xiangmin LI ; Xiaofei LI ; Xiaojuan LI ; Zhiqiang LI ; Zhongjun LI ; Zunyan LI ; Huaqin LIANG ; Xiaohua LIANG ; Dongfa LIAO ; Qun LIAO ; Yan LIAO ; Jiajin LIN ; Chunxia LIU ; Fenghua LIU ; Peixian LIU ; Tiemei LIU ; Xiaoxin LIU ; Zhiwei LIU ; Zhongdi LIU ; Hua LU ; Jianfeng LUAN ; Jianjun LUO ; Qun LUO ; Dingfeng LYU ; Qi LYU ; Xianping LYU ; Aijun MA ; Liqiang MA ; Shuxuan MA ; Xainjun MA ; Xiaogang MA ; Xiaoli MA ; Guoqing MAO ; Shijie MU ; Shaolin NIE ; Shujuan OUYANG ; Xilin OUYANG ; Chunqiu PAN ; Jian PAN ; Xiaohua PAN ; Lei PENG ; Tao PENG ; Baohua QIAN ; Shu QIAO ; Li QIN ; Ying REN ; Zhaoqi REN ; Ruiming RONG ; Changshan SU ; Mingwei SUN ; Wenwu SUN ; Zhenwei SUN ; Haiping TANG ; Xiaofeng TANG ; Changjiu TANG ; Cuihua TAO ; Zhibin TIAN ; Juan WANG ; Baoyan WANG ; Chunyan WANG ; Gefei WANG ; Haiyan WANG ; Hongjie WANG ; Peng WANG ; Pengli WANG ; Qiushi WANG ; Xiaoning WANG ; Xinhua WANG ; Xuefeng WANG ; Yong WANG ; Yongjun WANG ; Yuanjie WANG ; Zhihua WANG ; Shaojun WEI ; Yaming WEI ; Jianbo WEN ; Jun WEN ; Jiang WU ; Jufeng WU ; Aijun XIA ; Fei XIA ; Rong XIA ; Jue XIE ; Yanchao XING ; Yan XIONG ; Feng XU ; Yongzhu XU ; Yongan XU ; Yonghe YAN ; Beizhan YAN ; Jiang YANG ; Jiangcun YANG ; Jun YANG ; Xinwen YANG ; Yongyi YANG ; Chunyan YAO ; Mingliang YE ; Changlin YIN ; Ming YIN ; Wen YIN ; Lianling YU ; Shuhong YU ; Zebo YU ; Yigang YU ; Anyong YU ; Hong YUAN ; Yi YUAN ; Chan ZHANG ; Jinjun ZHANG ; Jun ZHANG ; Kai ZHANG ; Leibing ZHANG ; Quan ZHANG ; Rongjiang ZHANG ; Sanming ZHANG ; Shengji ZHANG ; Shuo ZHANG ; Wei ZHANG ; Weidong ZHANG ; Xi ZHANG ; Xingwen ZHANG ; Guixi ZHANG ; Xiaojun ZHANG ; Guoqing ZHAO ; Jianpeng ZHAO ; Shuming ZHAO ; Beibei ZHENG ; Shangen ZHENG ; Huayou ZHOU ; Jicheng ZHOU ; Lihong ZHOU ; Mou ZHOU ; Xiaoyu ZHOU ; Xuelian ZHOU ; Yuan ZHOU ; Zheng ZHOU ; Zuhuang ZHOU ; Haiyan ZHU ; Peiyuan ZHU ; Changju ZHU ; Lili ZHU ; Zhengguo WANG ; Jianxin JIANG ; Deqing WANG ; Jiongcai LAN ; Quanli WANG ; Yang YU ; Lianyang ZHANG ; Aiqing WEN
Chinese Journal of Trauma 2024;40(10):865-881
Patients with severe trauma require an extremely timely treatment and transfusion plays an irreplaceable role in the emergency treatment of such patients. An increasing number of evidence-based medicinal evidences and clinical practices suggest that patients with severe traumatic bleeding benefit from early transfusion of low-titer group O whole blood or hemostatic resuscitation with red blood cells, plasma and platelet of a balanced ratio. However, the current domestic mode of blood supply cannot fully meet the requirements of timely and effective blood transfusion for emergency treatment of patients with severe trauma in clinical practice. In order to solve the key problems in blood supply and blood transfusion strategies for emergency treatment of severe trauma, Branch of Clinical Transfusion Medicine of Chinese Medical Association, Group for Trauma Emergency Care and Multiple Injuries of Trauma Branch of Chinese Medical Association, Young Scholar Group of Disaster Medicine Branch of Chinese Medical Association organized domestic experts of blood transfusion medicine and trauma treatment to jointly formulate Chinese expert consensus on blood support mode and blood transfusion strategies for emergency treatment of severe trauma patients ( version 2024). Based on the evidence-based medical evidence and Delphi method of expert consultation and voting, 10 recommendations were put forward from two aspects of blood support mode and transfusion strategies, aiming to provide a reference for transfusion resuscitation in the emergency treatment of severe trauma and further improve the success rate of treatment of patients with severe trauma.
10.Serum myostatin and follistatin as biomarkers of sarcopenia in elderly women
Yanping DU ; Ye YANG ; Wenjing TANG ; Minmin CHEN ; Huilin LI ; Weijia YU ; Xiaoqing WU ; Liu SHEN ; Xuemei ZHANG ; Yuxiang ZHENG ; Jianfei GU ; Qun CHENG
Chinese Journal of Endocrinology and Metabolism 2024;40(6):500-504
Objective:This study aimed to explore the clinical value of myostatin(MST) and follistatin(FST) as biological biomarkers in evaluating sarcopenia in elderly women.Methods:This was a retrospective cross-sectional study that enrolled 350 females aged 20-89 years who underwent physical examinations in Shanghai Huadong Hospital in 2021. Demographic characteristics, muscle mass, fat mass, bone mineral density, hand grip strength, gait speed, and serum indices of MST and FST were collected.Results:The serum levels of MST did not change significantly with age. However, the serum levels of FST increased with age. In women aged≥60 years, MST was positively correlated with total lean mass and appendicular skeletal muscle index(ASMI; r=0.236, P=0.041; r=0.289, P=0.014), while FST was negatively correlated with ASMI( r=-0.265, P=0.030). In multivariate stepwise regression analysis, after adjusting for age, body mass index, hip bone mineral density, and total fat mass, only FST was independently correlated with ASMI( β=-0.238, P=0.006), while MST was not correlated with ASMI. The receiver operating characteristic curve was plotted using muscle mass reduction as the state variable and serum FST level as the test variable. The area under the curve was 0.753. And when the FST cutoff value was 17.49 ng/mL, the maximum Jordan index was 0.46, with a sensitivity of 77.3% and a specificity of 68.7%. Women aged ≥60 years were divided into three groups based on serum FST levels. Compared to the upper third of the serum FST level group, the low third of the FST level group had a significantly reduced risk of suffering from sarcopenia( OR=0.098, P =0.036). Conclusions:Serum FST lever has a better correlation with muscle mass among elderly women, making it a promising biomarker for evaluating muscle mass.

Result Analysis
Print
Save
E-mail