1.Validating the pathogenic mechanism of chronic obstructive pulmonary disease induced by negative emotions via Mendelian randomization and traditional Chinese medicine theory of emotions
Zhiying WANG ; Yun LI ; Zhixian ZHONG ; Ling XU ; Yi ZHONG ; Jian CHEN
Digital Chinese Medicine 2025;8(2):196-205
		                        		
		                        			Objective:
		                        			We employed Mendelian randomization (MR) to test the traditional Chinese medicine (TCM) theory of emotional pathogenesis concept and explore the causal relationship between negative emotions and chronic obstructive pulmonary disease (COPD). 
		                        		
		                        			Methods:
		                        			Data of negative emotions, bronchitis, emphysema, and C-reactive protein (CRP) levels were downloaded from genome-wide association study (GWAS) public database for a two-sample MR analysis. Independent single-nucleotide polymorphisms (SNPs) associated with negative emotions, bronchitis, and emphysema were selected as instrumental variables. Primary causal estimates were derived using inverse-variance weighting (IVW), supplemented by weighted median (WM), and simple mode (SM) methods. Sensitivity analyses included MR-Egger regression and MR-PRESSO to assess pleiotropy, Cochran’s Q test for heterogeneity, and multivariate MR to adjust for smoking. Mediation analysis evaluated the role of inflammatory markers. Reverse MR was tested for bidirectional causality. Weak instrument bias was mitigated via F-statistic thresholds (> 10). All analyses were conducted in RStudio. 
		                        		
		                        			Results:
		                        			MR analysis identified significant causal effects of several negative emotions on COPD. Genetically, the IVW analysis of seen doctors for nerves anxiety tension or depression [ORIVW = 1.006, 95% CI = (1.002, 1.010), P = 0.002], sensitivity/hurt feelings [ORIVW = 1.024, 95% CI = (1.004, 1.044), P = 0.017], and irritability [ORIVW = 1.019, 95% CI = (1.003, 1.035), P = 0.019 were robustly associated with increased risks of COPD. No heterogeneity was detected among the different instrumental variables (IVs) for depression (P = 0.655) and irritability (P = 0.163). MR-Egger regression intercepts for all emotional exposures were close to zero and statistically non-significant, indicating no evidence of directional pleiotropy. The horizontal pleiotropy results showed that except for worry (MR-PRESSO P = 0.006), other emotion exposures confirming no substantial pleiotropic bias. Multivariable MR demonstrated that anxiety remained independently associated with COPD after adjusting for smoking (P = 0.002), while associations with other negative emotions were attenuated post-adjustment. The mediation analysis revealed that CRP mediated 3.93% of the total effect of anxiety on COPD. However, reverse MR analysis found no evidence of reverse causality. 
		                        		
		                        			Conclusion
		                        			This study confirmed the causal effects of negative emotions on COPD through MR analysis and revealed that negative emotions may trigger CRP production, which plays an essential mediating role in this relationship. This study provides a reliable modern theoretical basis for emotion theory in TCM.  
		                        		
		                        		
		                        		
		                        	
2.Feixin Decoction Treats Hypoxic Pulmonary Hypertension by Regulating Pyroptosis in PASMCs via PPARγ/NF-κB/NLRP3 Signaling Pathway
Junlan TAN ; Xianya CAO ; Runxiu ZHENG ; Wen ZHANG ; Chao ZHANG ; Jian YI ; Feiying WANG ; Xia LI ; Jianmin FAN ; Hui LIU ; Lan SONG ; Aiguo DAI
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(18):1-9
		                        		
		                        			
		                        			ObjectiveTo investigate the mechanism by which Feixin decoction treats hypoxic pulmonary hypertension (HPH) by regulating the peroxisome proliferator-activated receptor gamma (PPARγ)/nuclear factor-kappa B (NF-κB)/NOD-like receptor pyrin domain containing 3 (NLRP3) signaling pathway. MethodsForty-eight male SD rats were randomly allocated into normal, hypoxia, and low-, medium- and high-dose (5.85, 11.7, 23.4 g·kg-1, respectively) Feixin decoction groups, with 8 rats in each group. Except the normal group, the remaining five groups were placed in a hypoxia chamber with an oxygen concentration of (10.0±0.5)% for 8 h per day, 28 days, and administrated with corresponding drugs during the modeling process. After 4 weeks of treatment, echocardiographic parameters [pulmonary artery acceleration time (PAT), pulmonary artery ejection time (PET), right ventricular anterior wall thickness (RVAWd), and tricuspid annular plane systolic excursion (TAPSE)] were measured for each group. The right ventricular systolic pressure (RVSP) was measured by the right heart catheterization method, and the right ventricular hypertrophy index (RVHI) was calculated by weighing the heart. The pathological changes in pulmonary arterioles were observed by hematoxylin-eosin staining. The co-localization of α-smooth muscle actin (α-SMA) with NLRP3, N-terminal gasdermin D (N-GSDMD), and cysteinyl aspartate-specific proteinase-1 (Caspase-1) in pulmonary arteries was detected by immunofluorescence. The protein levels of PPARγ, NF-κB, NLRP3, apoptosis-associated speck-like protein containing a CARD (ASC), N-GSDMD, interleukin-1β (IL-1β), interleukin-18(IL-18), and cleaved Caspase-1 in the lung tissue was determined by Western blot. The ultrastructural changes in pulmonary artery smooth muscle cells (PASMCs) were observed by transmission electron microscopy. ResultsCompared with the normal group, the hypoxia group showed increased RVSP and RVHI (P<0.01), decreased right heart function (P<0.01), increased pulmonary vascular remodeling (P<0.01), increased co-localization of α-SMA with NLRP3, N-GSDMD, and Caspase-1 in pulmonary arterioles (P<0.01), up-regulated protein levels of NF-κB, NLRP3, ASC, N-GSDMD, IL-1β, IL-18, and cleaved Caspase-1 in the lung tissue (P<0.05, P<0.01), a down-regulated protein level of PPARγ (P<0.05, P<0.01), and pyroptosis in PASMCs. Compared with the hypoxia group, Feixin decoction reduced RVSP and RVHI, improved the right heart function and ameliorated pulmonary vascular remodeling (P<0.05, P<0.01), decreased the co-localization of α-SMA with NLRP3, N-GSDMD, and Caspase-1 (P<0.05, P<0.01), down-regulated the protein levels of NF-κB, NLRP3, ASC, N-GSDMD, IL-1β, IL-18, and cleaved Caspase-1 in the lung tissue (P<0.05, P<0.01), up-regulated the protein level of PPARγ (P<0.05, P<0.01), and alleviated pyroptosis in PASMCs. ConclusionFeixin decoction can ameliorate pulmonary vascular remodeling and right heart dysfunction in chronically induced HPH rats by regulating pyroptosis in PASMCs through the PPARγ/NF-κB/NLRP3 pathway. 
		                        		
		                        		
		                        		
		                        	
3.Research progress of nano drug delivery system based on metal-polyphenol network for the diagnosis and treatment of inflammatory diseases
Meng-jie ZHAO ; Xia-li ZHU ; Yi-jing LI ; Zi-ang WANG ; Yun-long ZHAO ; Gao-jian WEI ; Yu CHEN ; Sheng-nan HUANG
Acta Pharmaceutica Sinica 2025;60(2):323-336
		                        		
		                        			
		                        			 Inflammatory diseases (IDs) are a general term of diseases characterized by chronic inflammation as the primary pathogenetic mechanism, which seriously affect the quality of patient′s life and cause significant social and medical burden. Current drugs for IDs include nonsteroidal anti-inflammatory drugs, corticosteroids, immunomodulators, biologics, and antioxidants, but these drugs may cause gastrointestinal side effects, induce or worsen infections, and cause non-response or intolerance. Given the outstanding performance of metal polyphenol network (MPN) in the fields of drug delivery, biomedical imaging, and catalytic therapy, its application in the diagnosis and treatment of IDs has attracted much attention and significant progress has been made. In this paper, we first provide an overview of the types of IDs and their generating mechanisms, then sort out and summarize the different forms of MPN in recent years, and finally discuss in detail the characteristics of MPN and their latest research progress in the diagnosis and treatment of IDs. This research may provide useful references for scientific research and clinical practice in the related fields. 
		                        		
		                        		
		                        		
		                        	
4.Study of adsorption of coated aldehyde oxy-starch on the indexes of renal failure
Qian WU ; Cai-fen WANG ; Ning-ning PENG ; Qin NIE ; Tian-fu LI ; Jian-yu LIU ; Xiang-yi SONG ; Jian LIU ; Su-ping WU ; Ji-wen ZHANG ; Li-xin SUN
Acta Pharmaceutica Sinica 2025;60(2):498-505
		                        		
		                        			
		                        			 The accumulation of uremic toxins such as urea nitrogen, blood creatinine, and uric acid of patients with renal failure 
		                        		
		                        	
5.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
		                        		
		                        			 Purpose:
		                        			This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard. 
		                        		
		                        			Methods:
		                        			Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated. 
		                        		
		                        			Results:
		                        			Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001). 
		                        		
		                        			Conclusion
		                        			Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD. 
		                        		
		                        		
		                        		
		                        	
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
7.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
		                        		
		                        			 Purpose:
		                        			This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard. 
		                        		
		                        			Methods:
		                        			Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated. 
		                        		
		                        			Results:
		                        			Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001). 
		                        		
		                        			Conclusion
		                        			Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD. 
		                        		
		                        		
		                        		
		                        	
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
9.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
		                        		
		                        			 Purpose:
		                        			This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard. 
		                        		
		                        			Methods:
		                        			Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated. 
		                        		
		                        			Results:
		                        			Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001). 
		                        		
		                        			Conclusion
		                        			Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD. 
		                        		
		                        		
		                        		
		                        	
10.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
            
Result Analysis
Print
Save