2.Adaptive extended‑field intensity-modulated radiation therapy with simultaneously integrated boost for locally advanced cervical cancer with lymph node metastases
Philippine Journal of Obstetrics and Gynecology 2023;47(6):320-324
Performing external beam radiotherapy alone without chemotherapy or brachytherapy for locally
advanced cervical cancer with multiple lymph node metastases is challenging. The purpose of
this case report is to present the efficacy of high‑dose adaptive extended‑field intensity‑modulated
radiotherapy (IMRT) with simultaneous integrated boost (SIB) in treating locally advanced cervical
cancer with multiple lymph node metastases. A 67‑year‑old woman with locally advanced squamous
cell carcinoma of the uterine cervix was treated by external beam radiotherapy alone due to the refusal
of chemotherapy and intracavitary brachytherapy. In order to maximize the efficacy of treatment,
extended‑field radiotherapy that includes the paraaortic lymph nodes as well as an adaptive IMRT‑SIB
plan, was applied. The treatment was successful, resulting in complete tumor disappearance without
severe adverse events. In conclusion, high‑dose adaptive IMRT‑SIB may be an alternative treatment
option for locally advanced cervical cancer with multiple lymph node metastases.
Radiation Dosage
;
Uterine Cervical Neoplasms
3.Application of micro-bolus injection and piezoelectric sensors to improve the safety of radiopharmaceuticals bolus injection.
Jin LI ; Yan WANG ; Jianxiong MA ; Xinxin PANG ; Wei ZHOU ; Cungui TIAN ; Guohui YANG ; Na ZHAO
Journal of Biomedical Engineering 2023;40(5):982-988
Radiopharmaceutical dynamic imaging typically necessitates intravenous injection via the bolus method. However, manual bolus injection carries the risk of handling errors as well as radiological injuries. Hence, there is potential for automated injection devices to replace manual injection methods. In this study, the effect of micro-bolus pulse injection technology was compared and verified by radioactive experiments using a programmable injection pump, and the overall bubble recognition experiment and rat tail vein simulation injection verification were performed using the piezoelectric sensor preloading method. The results showed that at the same injection peak speed, the effective flushing volume of micro-bolus pulse flushing (about 83 μL/pulse) was 49.65% lower than that of uniform injection and 25.77% lower than that of manual flushing. In order to avoid the dilution effect of long pipe on the volume of liquid, the use of piezoelectric sensor for sealing preloading detection could accurately predict the bubbles of more than 100 μL in the syringe. In the simulated injection experiment of rat tail vein, when the needle was placed in different tissues by preloading 100 μL normal saline, the piezoelectric sensor fed back a large difference in pressure attenuation rate within one second, which was 2.78% in muscle, 17.28% in subcutaneous and 54.71% in vein. Micro-bolus pulse injection method and piezoelectric sensor sealing preloading method have application potential in improving the safety of radiopharmaceutical automatic bolus injection.
Animals
;
Rats
;
Radiopharmaceuticals/administration & dosage*
4.Model construction and software design of computed tomography radiation system based on visualization.
Ying LIU ; Ting MENG ; Haowei ZHANG ; Heqing LU
Journal of Biomedical Engineering 2023;40(5):989-995
The Monte Carlo N-Particle (MCNP) is often used to calculate the radiation dose during computed tomography (CT) scans. However, the physical calculation process of the model is complicated, the input file structure of the program is complex, and the three-dimensional (3D) display of the geometric model is not supported, so that the researchers cannot establish an accurate CT radiation system model, which affects the accuracy of the dose calculation results. Aiming at these two problems, this study designed a software that visualized CT modeling and automatically generated input files. In terms of model calculation, the theoretical basis was based on the integration of CT modeling improvement schemes of major researchers. For 3D model visualization, LabVIEW was used as the new development platform, constructive solid geometry (CSG) was used as the algorithm principle, and the introduction of editing of MCNP input files was used to visualize CT geometry modeling. Compared with a CT model established by a recent study, the root mean square error between the results simulated by this visual CT modeling software and the actual measurement was smaller. In conclusion, the proposed CT visualization modeling software can not only help researchers to obtain an accurate CT radiation system model, but also provide a new research idea for the geometric modeling visualization method of MCNP.
Radiation Dosage
;
Software Design
;
Tomography, X-Ray Computed/methods*
;
Software
;
Algorithms
;
Phantoms, Imaging
;
Monte Carlo Method
6.Dosimetric Impact of Titanium Alloy Implant in Spinal IMRT Plan.
Xiaohui CHEN ; Anjie XU ; Jiayan CHEN ; Weigang HU ; Jiayuan PENG
Chinese Journal of Medical Instrumentation 2023;47(1):110-114
The purpose of this study is to establish and apply a correction method for titanium alloy implant in spinal IMRT plan, a corrected CT-density table was revised from normal CT-density table to include the density of titanium alloy implant. Dose distribution after and before correction were calculated and compared to evaluate the dose deviation. Plans were also copied to a spinal cancer simulation phantom. A titanium alloy fixation system for spine was implanted in this phantom. Plans were recalculated and compared with the measurement result. The result of this study shows that the max dose of spinal cord showed significant difference after correction, and the deviation between calculation results and measurement results was reduced after correction. The method for expanding the range CT-density table, which means that the density of titanium alloy was included, can reduce the error in calculation.
Radiotherapy, Intensity-Modulated/methods*
;
Titanium
;
Radiotherapy Dosage
;
Alloys
;
Radiometry/methods*
;
Radiotherapy Planning, Computer-Assisted/methods*
7.Analysis of risk factors of radiation-induced toxicity in limited-stage small cell lung cancer treated with hypofractionated intensity-modulated radiotherapy.
Jing Jing ZHAO ; Nan BI ; Tao ZHANG ; Jian Yang WANG ; Lei DENG ; Xin WANG ; Dong Fu CHEN ; Jian Rong DAI ; Luhua WANG
Chinese Journal of Oncology 2023;45(7):627-633
Objective: To compare the incidence of radiation-related toxicities between conventional and hypofractionated intensity-modulated radiation therapy (IMRT) for limited-stage small cell lung cancer (SCLC), and to explore the risk factors of hypofractionated radiotherapy-induced toxicities. Methods: Data were retrospectively collected from consecutive limited-stage SCLC patients treated with definitive concurrent chemoradiotherapy in Cancer Hospital of Chinese Academy of Medical Sciences from March 2016 to April 2022. The enrolled patients were divided into two groups according to radiation fractionated regimens. Common Terminology Criteria for Adverse Events (CTCAE, version 5.0) was used to evaluate the grade of radiation esophagus injuries and lung injuries. Logistic regression analyses were used to identify factors associated with radiation-related toxicities in the hypofractionated radiotherapy group. Results: Among 211 enrolled patients, 108 cases underwent conventional IMRT and 103 patients received hypofractionated IMRT. The cumulative incidences of acute esophagitis grade ≥2 [38.9% (42/108) vs 35.0% (36/103), P=0.895] and grade ≥ 3 [1.9% (2/108) vs 5.8% (6/103), P=0.132] were similar between conventional and hypofractionated IMRT group. Late esophagus injuries grade ≥2 occurred in one patient in either group. No differences in the cumulative incidence of acute pneumonitis grade ≥2[12.0% (13/108) vs 5.8% (6/103), P=0.172] and late lung injuries grade ≥2[5.6% (6/108) vs 10.7% (11/103), P=0.277] were observed. There was no grade ≥3 lung injuries occurred in either group. Using multiple regression analysis, mean esophageal dose ≥13 Gy (OR=3.33, 95% CI: 1.23-9.01, P=0.018) and the overlapping volume between planning target volume (PTV) and esophageal ≥8 cm(3)(OR=3.99, 95% CI: 1.24-12.79, P=0.020) were identified as the independent risk factors associated with acute esophagitis grade ≥2 in the hypofractionated radiotherapy group. Acute pneumonitis grade ≥2 was correlated with presence of chronic obstructive pulmonary disease (COPD, P=0.025). Late lung injuries grade ≥2 was correlated with tumor location(P=0.036). Conclusions: Hypofractionated IMRT are tolerated with manageable toxicities for limited-stage SCLC patients treated with IMRT. Mean esophageal dose and the overlapping volume between PTV and esophageal are independently predictive factors of acute esophagitis grade ≥2, and COPD and tumor location are valuable factors of lung injuries for limited-stage SCLC patients receiving hyofractionated radiotherapy. Prospective studies are needed to confirm these results.
Humans
;
Small Cell Lung Carcinoma/pathology*
;
Lung Neoplasms/pathology*
;
Radiotherapy, Intensity-Modulated/methods*
;
Retrospective Studies
;
Lung Injury
;
Radiotherapy Dosage
;
Radiation Injuries/epidemiology*
;
Esophagitis/epidemiology*
;
Risk Factors
;
Pulmonary Disease, Chronic Obstructive/complications*
8.Quality of Images Reconstructed by Deep Learning Reconstruction Algorithm for Head and Neck CT Angiography at 100 kVp.
Xiao-Ping LU ; Yun WANG ; Yu CHEN ; Yan-Ling WANG ; Min XU ; Zheng-Yu JIN
Acta Academiae Medicinae Sinicae 2023;45(3):416-421
Objective To evaluate the impact of deep learning reconstruction algorithm on the image quality of head and neck CT angiography (CTA) at 100 kVp. Methods CT scanning was performed at 100 kVp for the 37 patients who underwent head and neck CTA in PUMC Hospital from March to April in 2021.Four sets of images were reconstructed by three-dimensional adaptive iterative dose reduction (AIDR 3D) and advanced intelligent Clear-IQ engine (AiCE) (low,medium,and high intensity algorithms),respectively.The average CT value,standard deviation (SD),signal-to-noise ratio (SNR),and contrast-to-noise ratio (CNR) of the region of interest in the transverse section image were calculated.Furthermore,the four sets of sagittal maximum intensity projection images of the anterior cerebral artery were scored (1 point:poor,5 points:excellent). Results The SNR and CNR showed differences in the images reconstructed by AiCE (low,medium,and high intensity) and AIDR 3D (all P<0.01).The quality scores of the image reconstructed by AiCE (low,medium,and high intensity) and AIDR 3D were 4.78±0.41,4.92±0.27,4.97±0.16,and 3.92±0.27,respectively,which showed statistically significant differences (all P<0.001). Conclusion AiCE outperformed AIDR 3D in reconstructing the images of head and neck CTA at 100 kVp,being capable of improving image quality and applicable in clinical examinations.
Humans
;
Computed Tomography Angiography/methods*
;
Radiation Dosage
;
Deep Learning
;
Radiographic Image Interpretation, Computer-Assisted/methods*
;
Signal-To-Noise Ratio
;
Algorithms
9.Research Progress in Diagnostic Reference Levels in Interventional Radiology.
Pei-Yi QIAN ; Yun LIU ; Jia REN ; Xiao-Jun XU ; Zhi-Xin ZHAO ; Cheng-Jian CAO ; Lei YANG
Acta Academiae Medicinae Sinicae 2023;45(3):506-511
During interventional procedures,subjects are exposed to direct and scattered X-rays.Establishing diagnostic reference levels is an ideal way to optimize the radiation dose and reduce radiation hazard.In recent years,diagnostic reference levels in interventional radiology have been established in different countries.However,because of the too many indicators for characterizing the radiation dose,the indicators used to establish diagnostic reference levels vary in different countries.The research achievements in this field remain to be reviewed.We carried out a retrospective analysis of the definition,establishment method,application,and main factors influencing the dose difference of the diagnostic reference level,aiming to provide a basis for establishing the diagnostic reference level for interventional procedures in China.
Humans
;
Diagnostic Reference Levels
;
Radiology, Interventional/methods*
;
Radiation Dosage
;
Retrospective Studies
;
Radiography
10.Application of PET-LINAC in Biology-guided Radiotherapy.
Xin YANG ; Wei ZHAO ; Xinzhi TIAN ; Jun CAI ; Siwei XIE ; Qi LIU ; Hao PENG ; Qiyu PENG
Chinese Journal of Medical Instrumentation 2023;47(3):237-241
Biology-guided radiotherapy (BgRT) is a novel technique of external beam radiotherapy, combining positron emission tomography-computed tomography (PET-CT) with a linear accelerator (LINAC). The key innovation is to utilize PET signals from tracers in tumor tissues for real-time tracking and guiding beamlets. Compared with a traditional LINAC system, a BgRT system is more complex in hardware design, software algorithm, system integration and clinical workflow. RefleXion Medical has developed the world's first BgRT system. Nevertheless, its actively advertised function, PET-guided radiotherapy, is still in the research and development phase. In this review study, we presented a number of issues related to BgRT, including its technical advantages and potential challenges.
Positron Emission Tomography Computed Tomography
;
Radiotherapy Planning, Computer-Assisted/methods*
;
Algorithms
;
Particle Accelerators
;
Biology
;
Radiotherapy, Image-Guided/methods*
;
Radiotherapy Dosage


Result Analysis
Print
Save
E-mail