1.Comparisons of dose distributions between IMPT and VMAT for pancreatic cancer
Yangsen CAO ; Zuofeng LI ; Ning XU ; Xiaojing GUO ; Huojun ZHANG
Chinese Journal of Radiological Medicine and Protection 2022;42(2):103-109
Objective:To compare dose distributions of hypofractionated radiotherapy for pancreatic cancer between IMPT and VMAT.Methods:Ten pancreatic cancer cases were included in this retrospective study. Photon (Edge) and proton (Proteus?PLUS) plans were designed by Eclipse and RayStation TPS, respectively. All plans were transferred to MIM system for extraction of parameters, which included Dmin, Dmean and Dmax of PTV, conformity index (CI), new conformity index (nCI), homogeneity index (HI), gradient index (GI), coverage, Dmax and dose-volume of the organs at risk (OARs). Results:There was no significant difference in CI between the two groups. The higher PTV Dmin, Dmean, Dmax, D98%, D2%, HI, coverage and the better GI, D2 cmwere found in VMAT ( t/ Z=-4.63-5.32, P<0.05). The lower 10%_PD was found in IMPT ( t=-7.47, P<0.05). Regarding the OARs, Dmax of the intestine, stomach, and duodenum and Dmean of the left kidney were similar between two groups without significant difference ( P>0.05). The D5 cm 3 of the intestine, D10 cm 3 of the stomach, D5 cm 3 and D10 cm 3 of the duodenum, D2/3 of the left kidney, Dmean and D2/3 of the right kidney were lower in IMPT than those in VMAT ( t/ Z=-8.12--2.60, P<0.05). However, the Dmax and D0.35 cm 3 of the spinal cord were higher in IMPT than those in VMAT ( t=7.30, 6.77, P<0.05). Conclusions:Both of hypofractionated radiotherapy plans of pancreatic cancer designed by VMAT and IMPT could meet clinical needs. No significant difference was found in Dmax of the adjacent gastrointestinal tracts between the two groups. While IMPT had the advantage over VMAT in the case of lower dose-volumes of the gastrointestinal tracts. Nevertheless, less protections of the OARs in front of the tumor volume could be provided by IMPT compared with VMAT.
2.Intensity of Intraoperative Spinal Cord Hyperechogenicity as a Novel Potential Predictive Indicator of Neurological Recovery for Degenerative Cervical Myelopathy
Guoliang CHEN ; Fuxin WEI ; Jiachun LI ; Liangyu SHI ; Wei ZHANG ; Xianxiang WANG ; Zuofeng XU ; Xizhe LIU ; Xuenong ZOU ; Shaoyu LIU
Korean Journal of Radiology 2021;22(7):1163-1171
Objective:
To analyze the correlations between intraoperative ultrasound and MRI metrics of the spinal cord in degenerative cervical myelopathy and identify novel potential predictive ultrasonic indicators of neurological recovery for degenerative cervical myelopathy.
Materials and Methods:
Twenty-two patients who underwent French-door laminoplasty for multilevel degenerative cervical myelopathy were followed up for 12 months. The Japanese Orthopedic Association (JOA) scores were assessed preoperatively and 12 months postoperatively. Maximum spinal cord compression and compression rates were measured and calculated using both intraoperative ultrasound imaging and preoperative T2-weight (T2W) MRI. Signal change rates of the spinal cord on preoperative T2W MRI and gray value ratios of dorsal and ventral spinal cord hyperechogenicity on intraoperative ultrasound imaging were measured and calculated. Correlations between intraoperative ultrasound metrics, MRI metrics, and the recovery rate JOA scores were analyzed using Spearman correlation analysis.
Results:
The postoperative JOA scores improved significantly, with a mean recovery rate of 65.0 ± 20.3% (p < 0.001). No significant correlations were found between the operative ultrasound metrics and MRI metrics. The gray value ratios of the spinal cord hyperechogenicity was negatively correlated with the recovery rate of JOA scores (ρ = -0.638, p = 0.001), while the ventral and dorsal gray value ratios of spinal cord hyperechogenicity were negatively correlated with the recovery rate of JOA-motor scores (ρ = -0.582, p = 0.004) and JOA-sensory scores (ρ = -0.452, p = 0.035), respectively. The dorsal gray value ratio was significantly higher than the ventral gray value ratio (p < 0.001), while the recovery rate of JOA-motor scores was better than that of JOA-sensory scores at 12 months post-surgery (p = 0.028).
Conclusion
For degenerative cervical myelopathy, the correlations between intraoperative ultrasound and preoperative T2W MRI metrics were not significant. Gray value ratios of the spinal cord hyperechogenicity and dorsal and ventral spinal cord hyperechogenicity were significantly correlated with neurological recovery at 12 months postoperatively.
3.Intensity of Intraoperative Spinal Cord Hyperechogenicity as a Novel Potential Predictive Indicator of Neurological Recovery for Degenerative Cervical Myelopathy
Guoliang CHEN ; Fuxin WEI ; Jiachun LI ; Liangyu SHI ; Wei ZHANG ; Xianxiang WANG ; Zuofeng XU ; Xizhe LIU ; Xuenong ZOU ; Shaoyu LIU
Korean Journal of Radiology 2021;22(7):1163-1171
Objective:
To analyze the correlations between intraoperative ultrasound and MRI metrics of the spinal cord in degenerative cervical myelopathy and identify novel potential predictive ultrasonic indicators of neurological recovery for degenerative cervical myelopathy.
Materials and Methods:
Twenty-two patients who underwent French-door laminoplasty for multilevel degenerative cervical myelopathy were followed up for 12 months. The Japanese Orthopedic Association (JOA) scores were assessed preoperatively and 12 months postoperatively. Maximum spinal cord compression and compression rates were measured and calculated using both intraoperative ultrasound imaging and preoperative T2-weight (T2W) MRI. Signal change rates of the spinal cord on preoperative T2W MRI and gray value ratios of dorsal and ventral spinal cord hyperechogenicity on intraoperative ultrasound imaging were measured and calculated. Correlations between intraoperative ultrasound metrics, MRI metrics, and the recovery rate JOA scores were analyzed using Spearman correlation analysis.
Results:
The postoperative JOA scores improved significantly, with a mean recovery rate of 65.0 ± 20.3% (p < 0.001). No significant correlations were found between the operative ultrasound metrics and MRI metrics. The gray value ratios of the spinal cord hyperechogenicity was negatively correlated with the recovery rate of JOA scores (ρ = -0.638, p = 0.001), while the ventral and dorsal gray value ratios of spinal cord hyperechogenicity were negatively correlated with the recovery rate of JOA-motor scores (ρ = -0.582, p = 0.004) and JOA-sensory scores (ρ = -0.452, p = 0.035), respectively. The dorsal gray value ratio was significantly higher than the ventral gray value ratio (p < 0.001), while the recovery rate of JOA-motor scores was better than that of JOA-sensory scores at 12 months post-surgery (p = 0.028).
Conclusion
For degenerative cervical myelopathy, the correlations between intraoperative ultrasound and preoperative T2W MRI metrics were not significant. Gray value ratios of the spinal cord hyperechogenicity and dorsal and ventral spinal cord hyperechogenicity were significantly correlated with neurological recovery at 12 months postoperatively.
4.Value analysis of ultrasound-guided fine needle and core needle biopsy of cervical lymph nodes in diagnosis
Fengping LIANG ; Rong HUANG ; Yibin WANG ; Qiao JI ; Xuankun LIANG ; Xianxiang WANG ; Yujun HUANG ; Xiaofang LU ; Zuofeng XU
Journal of Chinese Physician 2019;21(2):180-183
Objective To compare the value of ultrasound-guided fine-needle aspiration (FNA) and core needle biopsy (CNB) in diagnosing benign and malignant cervical lymph nodes.Methods A retrospective analysis was performed on 88 patients who received biopsy for cervical lymph node enlargement from January 2015 to May 2017.FNA (n =39) or CNB (n =49) were performed respectively to compare the sensitivity,specificity and accuracy of the two methods in diagnosing benign and malignant cervical lymph node enlargement.Results 84.6% (33/39) of FNA cases were successfully collected,and 98% (48/49) of FNA cases were successfully collected for definite pathological diagnosis (P =0.000).The sensitivity,specificity and accuracy of FNA and CNB in diagnosing malignant cervical lymph nodes were 90.9% and 97.2%,94.1% and 100%,92.3% and 98%,respectively.Compared with FNA,there were statistically significant differences in sensitivity,specificity and accuracy in differentiating benign and malignant lymphatic lesions in cervical enlargement (P <0.01).The sensitivity and specificity of FNA and CNB in diagnosing cervical lymph node metastatic carcinoma were 100% and 100%,95.2% and 100%.Compared with FNA,there was no statistically significant difference in the sensitivity to the diagnosis of cervical lymph node metastatic carcinoma (P =0.102).Conclusions CNB is superior to FNA in sensitivity,specificity and accuracy in diagnosing cervical lymphadenopathy.However,when metastatic cancer was diagnosed,FNA was not significantly different from CNB in sensitivity (P =0.102),and FNA was recommended as the first choice.
5.CEUS in differential diagnosis of renal focal hyperechoic lesions
Yangdi WANG ; Zuofeng XU ; Xiaoyu ZHOU ; Meiqing CHENG ; Mengfei XIAN
Chinese Journal of Medical Imaging Technology 2018;34(2):284-287
Objective To investigate the value of CEUS in differential diagnosis of benign and malignant renal focal hyperechoic lesions.Methods Data of conventional ultrasound (US) and CEUS of 56 patients with single renal focal hyperechoic lesion were retrospectively analyzed,and differential diagnosis of benign and malignant lesions was performed with US and CEUS,respectively.Taking pathological diagnosis as golden standard,the diagnostic efficacy of US and CEUS were calculated and compared.Results The sensibility,specificity,positive predictive value (PPV),negative predictive value (NPV) and accuracy of US was 70.00% (14/20),75.00% (27/36),60.87% (14/23),81.82% (27/33) and 73.21% (41/56),while of CEUS was 80.00% (16/20),94.44% (34/36),88.89% (16/18),89.47% (34/38) and 89.29 % (50/56),respectively.The accuracy,specificity and PPV of CEUS were higher than those of US (all P<0.05).The consistency of CEUS and pathology was good (Kappa=0.761),while of US and pathology was ordinary (Kappa=0.435).Conclusion CEUS can improve differential diagnostic efficacy of renal focal hyperechoic lesions.
6.Application value of contrast-enhanced ultrasound in vascular complications of transplanted kidney
Chuan PENG ; Manxia LIN ; Yan WANG ; Changxi WANG ; Xiaoyan XIE ; Zuofeng XU
Organ Transplantation 2015;(1):41-45
Objective To evaluate the application value of contrast-enhanced ultrasound (CEUS) in the diagnosis of vascular complication (VC) of transplanted kidney. Methods Imaging data of conventional ultrasound and CEUS in 28 patients suspected with VC of transplanted kidney were analyzed retrospectively.The results of computed tomography angiography (CTA)or digital subtraction angiography (DSA)were served as the diagnostic standard. The value of CEUS in diagnosing VC of transplanted kidney was analyzed. Results No adverse reaction related to contrast agent was observed in 28 patients during the CEUS examination. And 22 cases with VC were confirmed. VCs were detected correctly by CEUS in 17 cases,but 5 cases with transplant renal artery stenosis (TRAS ) were missed and 1 case with focal infarction in transplanted kidney was misdiagnosed. The diagnostic sensitivity,specificity,positive predictive value (PPV),negative predictive value (NPV)and accuracy of CEUS for VC of transplanted kidney were 0.77,1.00,1.00,0.55 and 0.82, respectively. The diagnostic sensitivity,specificity,PPV,NPV and accuracy of conventional ultrasound and CEUS for TRAS were 0.37 and 0.74,0.89 and 1.00,0.88 and 1.00,0.40 and 0.64,0.54 and 0.82, respectively. There were significant differences in the sensitivity and accuracy between conventional ultrasound and CEUS (both in P<0.05 ). Conclusions CEUS is an effective method for detecting VC of transplanted kidney.
7.Application of contrast-enhanced ultrasound in percutaneous nephrostomy for the treatment of complex renal calculi
Meiqing CHENG ; Xiaohua XIE ; Xiaoyan XIE ; Mingde Lü ; Zuofeng XU ; Ming LIU ; Zuanan CHEN
Chinese Journal of Ultrasonography 2013;(6):515-517
Objective To investigate the value of contrast-enhanced ultrasound (CEUS) in percutaneous nephrostomy for the treatment of complex renal calculi without hydronephrosis.Methods 22 patients with complex renal calculi underwent puncture and catheterization under the conventional ultrasound guidance,and then were injected with ultrasound contrast agent (SonoVue) through the needles and tubes to confirm appropriate puncture and catheterization.The display rates of puncture needle,renal pelvis,calyces,drainage tube body and distal end under CEUS were observed,and the results were compared with those of routine ultrasonography.The dosage of contrast agent,success rate and complications were also recorded.Results The display rates of puncture needle,renal pelvis,calyces,drainage tube body and distal end under routine ultrasonography were 63.64%,36.36%,63.64%,18.18%,as compared with CEUS the display rates were 100%,100%,100%,81.18%.The differences were statistically significant between CEUS and routine ultrasonography (P < 0.05).Conclusions CEUS guided percutaneous catheterization makes up for the inadequacy of conventional ultrasound in patients of complex renal calculi without hydronephrosis,and it can be worthy for clinical application.
8.Combined ultrasound-guided radiofrequency ablation and ethanol injection with a multipronged needle for the treatment of hepatocellular carcinoma ranging from 3.0 to 7.0 cm in diameter
Guangliang HUANG ; Xiaoyan XIE ; Ming KUANG ; Zuofeng XU ; Guanjian LIU ; Yanling ZHENG ; Mingde Lü
Chinese Journal of Ultrasonography 2013;22(7):591-594
Objective To evaluate the therapeutic efficacy and safety of radiofrequency ablation (RFA) combined with ethanol injection with a multipronged needle under ultrasound guidance for the treatment of hepatocellular carcinoma (HCC) larger than 3 cm in diameter.Methods 65 patients with 67HCC nodules ranging from 3.1 to 7.0 cm in diameter were treated percutaneously under ultrasound guidance.Tumor response and complications after treatment were observed.Results Complete ablation was achieved in 94.0% (63/67) of HCC nodules.4 residual tumor nodules received complete ablation after additional treatment.Ablation-related major complications was occurred in 3 patients,including liver abscess in 1 case,abdominal bleeding in 1 case and massive ascites in 1 case,all were cured by conservative therapy.After a mean follow-up period of (20.0 ± 7.6) months (6.7-32.6 months),local-tumor progression was observed in 10 (14.9%) of 67 HCC nodules,and distant recurrence was observed in 32 (49.2%) of 65patients.The 1-year and 2-year survival rate were 93.1 % and 88.1%,respectively.Conclusions RFA combined with ethanol injetion with a multipronged needle is a safe and effective technique for the treatment of hepatocellular carcinoma larger than 3 cm,especially 3-5 cm in diameter.
9.Comparison of enhancement pattern and differential diagnosis efficacy between contrast-enhanced ultrasound and contrast-enhanced computed tomography for gallbladder diseases
Xiaohua XIE ; Xiaoyan XIE ; Guangjian LIU ; Zuofeng XU ; Yanling ZHENG ; Li LIU ; Zhu WANG ; Mingde Lü
Chinese Journal of Ultrasonography 2012;(12):1048-1051
Objective To compare the enhancement characteristic of the gallbladder diseases and to evaluate the diagnostic efficacy in differential diagnosis of the gallbladder diseases between contrast-enhanced sonography (CEUS) and contrast-enhanced computed tomography (CECT).Methods Seventy-two patiens with gallbladder lesions were examined by CEUS and CECT before operation and all final diagnoses were confirmed by surgery and/or pathological diagnosis.Results 1)In early phase,84.6% (33/39) and 79.5% (31/39) of benign diseases showed hyper-enhancement on CEUS and CECT,and 97.0% (32/33) and 87.9% (29/33) of malignant diseases showed hyper-enhancement on CEUS and CECT respectively (P =0.250).In later phase,91.2% (31/34) and 88.2% (30/34) of benign diseases showing hypo-enhancement (P =1.000),and 100% of the malignant diseases showing hypo-enhancement on CEUS and CECT respectively.2)The time of enhancement from hyper-to hypo in CEUS for benign and malignant diseases were (39.9 ± 15.7)s and (29.9 ± 5.6)s respectively (t =3.61,P =1.000).3)The inhomogeneous enhancement on CEUS and CECT were 41.0% (16/39) and 53.8% (21/39) in the benign diseases respectively (P =0.063),84.8 % (28/33) and 97.0 % (32/33) in the malignant diseases respectively(P =0.125).4)The destruction of the gallbladder wall on CEUS and CECT are 87.9% (29/33) and 90.9% (30/33) respectively(P =1.000).5)The accuracy,diagnostic sensitivity,specificity of CEUS and CECT were 91.7%(66/72) and 87.5%(63/72),97.0%(32/33) and 93.9%(31/33),87.2%(34/39) and 82.15% (32/39) respectively (P =0.250,1.000,0.500).Conclusions The enhancement pattern of the gallbladder diseases on CEUS and CECT were much similar.CEUS has equal diagnostic efficacy in comparison with CECT,but CEUS can supply more diagnostic information than CECT.
10.Identification and adhesion experiment of microbubbles targeted to angiogenesis
Wei WANG ; Guangjian LIU ; Xiaoyan XIE ; Zuofeng XU ; Lida CHEN ; Guangliang HUANG ; Mingde Lü
Chinese Journal of Ultrasonography 2011;20(7):621-624
Objective To identify microbubbles targeted (MBt) to alpha(v)beta(3) (αvβ3) via biotin-avidin bridge and evaluate the adhesion to human umbilical vein endothelial cells (HUVECs) in vitro.Methods MBt produced via biotin-avidin bridge were validated using fluorescence in vitro.Adhesion of αvβ3-integrin targeted MBt (MBαvβ3) to HUVECs was tested using the parallel plate flow chamber (PPFC) test.Results Bright green fluorescence was observed on the biotinylated microbubbles(MBB) incubated with fluorescein isothiocyanate labeled streptavidin (FITC-SA) and on MBB-SA incubated with FITC labeled biotin.There was no fluorescence seen on non-targeted control microbubbles,MBB incubated with FITC labeled protein A and MBB-SA incubated with FITC labeled protein A. The adherent rate of MBαvβ3 was significantly higher than MBt with non-specific antibody (MBN) in PPFC test,with 9.9±3.1 of MBαvβ3 and 0.8±0.3 of MBN adhered to HUVECs,respectively(P<0.05).Conclusions Avβ3 targeted microbubbles using biotin-avidin bridging method is highly efficient and reliable for HUVECs.

Result Analysis
Print
Save
E-mail