1.Principles, technical specifications, and clinical application of lung watershed topography map 2.0: A thoracic surgery expert consensus (2024 version)
Wenzhao ZHONG ; Fan YANG ; Jian HU ; Fengwei TAN ; Xuening YANG ; Qiang PU ; Wei JIANG ; Deping ZHAO ; Hecheng LI ; Xiaolong YAN ; Lijie TAN ; Junqiang FAN ; Guibin QIAO ; Qiang NIE ; Mingqiang KANG ; Weibing WU ; Hao ZHANG ; Zhigang LI ; Zihao CHEN ; Shugeng GAO ; Yilong WU
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(02):141-152
With the widespread adoption of low-dose CT screening and the extensive application of high-resolution CT, the detection rate of sub-centimeter lung nodules has significantly increased. How to scientifically manage these nodules while avoiding overtreatment and diagnostic delays has become an important clinical issue. Among them, lung nodules with a consolidation tumor ratio less than 0.25, dominated by ground-glass shadows, are particularly worthy of attention. The therapeutic challenge for this group is how to achieve precise and complete resection of nodules during surgery while maximizing the preservation of the patient's lung function. The "watershed topography map" is a new technology based on big data and artificial intelligence algorithms. This method uses Dicom data from conventional dose CT scans, combined with microscopic (22-24 levels) capillary network anatomical watershed features, to generate high-precision simulated natural segmentation planes of lung sub-segments through specific textures and forms. This technology forms fluorescent watershed boundaries on the lung surface, which highly fit the actual lung anatomical structure. By analyzing the adjacent relationship between the nodule and the watershed boundary, real-time, visually accurate positioning of the nodule can be achieved. This innovative technology provides a new solution for the intraoperative positioning and resection of lung nodules. This consensus was led by four major domestic societies, jointly with expert teams in related fields, oriented to clinical practical needs, referring to domestic and foreign guidelines and consensus, and finally formed after multiple rounds of consultation, discussion, and voting. The main content covers the theoretical basis of the "watershed topography map" technology, indications, operation procedures, surgical planning details, and postoperative evaluation standards, aiming to provide scientific guidance and exploration directions for clinical peers who are currently or plan to carry out lung nodule resection using the fluorescent microscope watershed analysis method.
2.Follow-up study of left heart valve regurgitation after implantation of left ventricular assist device
Junjiang LIU ; Wenrui MA ; Dingqian LIU ; Yun ZHAO ; Lili DONG ; Zhe LUO ; Kefang GUO ; Chunsheng WANG ; Xiaoning SUN
Chinese Journal of Clinical Medicine 2025;32(1):72-77
Objective To explore the valve regurgitation status of left heart after the implantation of left ventricular assist device (LVAD) and its effect on prognosis of patients with LVAD implantation. Methods A total of 35 patients with cardiomyopathy who underwent magnetic levitation LVAD implantation at Zhongshan Hospital, Fudan University from February 2021 to July 2024 were retrospectively selected. Clinical data during hospitalization were collected, including preoperative basic data and postoperative valve regurgitation status. Telephone follow-ups were conducted to monitor patients’ survival status and transthoracic echocardiography was used to assess left valve function. Kaplan-Meier survival curves and log-rank test were employed to compare the survival rate of patients with different levels of valve regurgitation. Results The 35 patients had a mean age of (53.9±11.1) years, with 85.7% male, and 3 patients (8.6%) died during hospitalization. Preoperatively, 17 patients (48.6%) had moderate or greater mitral regurgitation, while all 35 patients had less than moderate aortic regurgitation. One month postoperatively, thirty patients were followed up, among which 24 patients (80%) had less than moderate mitral regurgitation, including 11 cases with alleviated regurgitation compared to pre-surgery; 6 patients (20%) had moderate or greater mitral regurgitation, including 4 cases with stable regurgitation and 2 cases with progression of regurgitation compared to pre-surgery; 2 patients (6.7%) had progression of aortic regurgitation to moderate or greater. The follow-up time was 1.2 (1.0, 2.1) years, with 1-year survival rate of 91.4% and 3-year survival rate of 71.1%. Survival analysis showed that the 3-year survival rate of patients with moderate or greater mitral regurgitation one month postoperatively was significantly lower than that of patients with less than moderate regurgitation (66.7% vs 83.3%, P=0.046). Conclusions After the implantation of magnetic levitation LVAD, most patients showed improvement in mitral regurgitation, while aortic regurgitation remained unchanged. The degree of mitral regurgitation one month postoperatively is associated with prognosis.
3.Expert consensus on dispensing management of intravenous infusion drugs for clinical trials in PIVAS
Xingchen YANG ; Wenhuan FU ; Donghui LAO ; Jing ZHAO ; Jianzhong ZHANG ; Group PHARMACY ; Committee HOSPITAL ; Association Pharmaceutical SHANGHAI
China Pharmacy 2025;36(1):1-6
OBJECTIVE To further standardize the dispensing management standard of intravenous infusion drugs for clinical trials in pharmacy intravenous admixture services (PIVAS), and provide reference for medical institutions to provide high-quality pharmaceutical services. METHODS Initiated by PIVAS Group, Hospital Pharmacy Professional Committee, Shanghai Pharmaceutical Association, jointly led by Longhua Hospital, Shanghai University of Traditional Chinese Medicine and Shanghai Geriatric Medical Center, a writing group was established by PIVAS experts from multiple medical institutions to discuss the basic requirements and dispensing process of intravenous infusion drugs for clinical trials in PIVAS. The experts from the leading unit sorted out, summarized, analyzed, fed back and revised the opinions, and finally reached Expert Consensus on Dispensing Management of Intravenous Infusion Drugs for Clinical Trials in PIVAS. RESULTS & CONCLUSIONS The main contents of this consensus include information management, operation process, fund management and document management of intravenous infusion drugs for clinical trials in PIVAS. This consensus establishes a more standardized model for dispensing management of intravenous infusion drugs for clinical trials in PIVAS, by standardizing clinical trail drug management operational procedures, accurately recording and preserving drug-related information, with the aim of achieving standardized and meticulous management of PIVAS’s receipt of clinical trial drugs.
4.Herbal Textual Research on Houttuyniae Herba in Famous Classical Formulas
Dan ZHAO ; Changgui YANG ; Chuanzhi KANG ; Chenghong XIAO ; Zhikun WU ; Hongliang MA ; Jiwen WANG ; Xiufu WAN ; Sheng WANG ; Zhilai ZHAN
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(8):250-259
This article systematically analyzes the historical evolution of the name, medicinal parts, origin, harvesting, processing and other aspects of Houttuyniae Herba(HH) by referring to the medical books, prescription books and other documents of the past dynasties, combined with the research materials related to modern and contemporary times, in order to provide a basis for the development of famous classical formulas containing this herb. In ancient literature, HH was often referred to as "Ji" and "Jicai", the name of "Ji" was first recorded in Mingyi Bielu during the Han and Wei dynasties, and the name of Yuxingcao was first seen in Lyuchanyan Bencao during the southern Song dynasty and has continued to this day. The origin of HH used throughout history is consistent, all of which are the whole herb or aboveground parts of Houttuynia cordata in Saururaceae family. HH recorded throughout history has a wide range of production areas, mostly self-produced self-marketing. In ancient times, fresh HH was often used as medicine by pounding its juice without involving any processing steps. Both fresh and dried products can be used as medicine, the fresh products uses the whole plant, while the dried products uses the aboveground parts, which are cleaned, selected and processed before use. Fresh products are harvested regardless of season, while dried products are harvested in both summer and autumn, with summer as the best. In ancient times, there were no specific requirements for the quality of HH, while in modern times, "intact stems and leaves with a strong fishy smell" are preferred. In addition, the medicinal properties of HH have undergone significant changes from ancient to modern times. In the early period, it was believed that its medicinal property was slightly warm, until the 1977 edition of Chinese Pharmacopoeia officially changed it to slightly cold. Both ancient and modern literature states that HH can be used for the treatment of carbuncle and malignant sores, Lyuchanyan Bencao for the first time introduced HH fresh juice can relieve summer heat, since Diannan Bencao recorded that it can be used for lung carbuncle, and gradually developed into the first choice for the treatment of lung carbuncle. Based on the research results, it is suggested that fresh herb or dried aboveground parts of H. cordata are used as medicine when developing famous classical formulas.
5.Value of three-dimensional inversion-recovery with real reconstruction sequence using an ultralong repetition time for endolymphatic hydrops
Menglong ZHAO ; Huaili JIANG ; Shujie ZHANG ; Zhuang LIU ; Kai LIU ; Di WU ; Xinsheng HUANG ; Mengsu ZENG
Chinese Journal of Clinical Medicine 2025;32(2):200-206
Objective To evaluate the value of an optimized three-dimensional inversion-recovery with real reconstruction (3D-real IR) sequence with a longer repetition time (TR, 16 000 ms) based on modulated flip angle technique in refocused imaging with extended echo train (MATRIX) in the endolymphatic hydrops (EH) imaging after intratympanic gadolinium (Gd) administration, and to compare it with a conventional 3D-real IR based on the turbo spin echo (TSE) sequence. Methods From July 2021 to November 2022, twenty-seven patients received both the conventional and optimized 3D-real IR sequences after bilateral intratympanic Gd administration. Images of the two sequences were qualitativly evaluated and compared. Contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR), and area ratio of endolymph against the total lymphatic space from the two sequences were measured and compared. Results 14(25.9%) ears with insufficient contrast for the EH diagnosis on the conventional sequence were clearly displayed on the optimized sequence. Image score, CNR and SNR of the optimized sequence were significantly higher than those of the conventional sequence (P < 0.001). The scanning time of two sequences was similar. The area ratio of endolymph against the total lymphatic space in the cochlear was significantly higher on the conventional 3D-real IR than that on the optimized 3D-real IR (P < 0.001); there was no statistical difference in the vestibule between the two sequences. Conclusions Compared with conventional sequence, optimized 3D-real IR sequence with a longer TR may be better for evaluation of EH after intratympanic Gd administration.
6.Application of three-dimensional fluid-attenuated inversion recovery sequence using artificial intelligence-assisted compressed sensing technique in intravenous gadolinium contrast-enhanced magnetic resonance imaging of inner ear
Kai LIU ; Jian WANG ; Huaili JIANG ; Shujie ZHANG ; Di WU ; Xinsheng HUANG ; Mengsu ZENG ; Menglong ZHAO
Chinese Journal of Clinical Medicine 2025;32(2):212-217
Objective To investigate the value of artificial intelligence-assisted compressed sensing (ACS) technology for intravenous gadolinium contrast-enhanced magnetic resonance imaging of the inner ear using three-dimensional fluid-attenuated inversion recovery (3D-FLAIR) sequence. Methods The patients received gadolinium contrast-enhanced magnetic resonance imaging using ACS and united compressed sensing (uCS) 3D-FLAIR at Zhongshan Hospital, Fudan University from January to November 2024 were prospectively enrolled. The repetition time was 16 000 ms, and acquisition time was 6 min 40 s and 10 min 24 s in ACS 3D-FLAIR and uCS 3D-FLAIR, respectively. The images on the two sequences were evaluated independently by two radiologists. The image quality of the two sequences was subjectively evaluated and compared. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were compared between the two sequences. The grading consistencies using two sequences and between the two doctors were analyzed. Results There was no statistically difference in subjective score of image quality between the two sequences. SNR and CNR of the ACS 3D-FLAIR sequence were significantly higher than those of the uCS 3D-FLAIR sequence (P<0.001). The kappa values of grades of cochlear and vestibular endolymphatic hydrops were 0.942 and 0.888 using two sequences (P<0.001). The kappa values of grades of cochlear and vestibular endolymphatic hydrops using the ACS 3D-FLAIR sequence between the two doctors were 0.784 and 0.831, respectively (P<0.001); the kappa values of grades of cochlear and vestibular endolymphatic hydrops using uCS 3D-FLAIR sequence between the two doctors were 0.725 and 0.756, respectively (P<0.001). Conclusions ACS 3D-FLAIR could provide higher SNR and CNR than uCS 3D-FLAIR, and is more suitable for intravenous gadolinium contrast-enhanced magnetic resonance imaging of the inner ear; the endolymphatic hydrops grades using ACS 3D-FLAIR is similar to use uCS 3D-FLAIR.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
9.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
10.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.

Result Analysis
Print
Save
E-mail