1.Study on Quality Evaluation of Symbiotic Armillaria in Gastrodia elata Bl. Based on AHP-Entropy Weight Method
Yuanfan ZHANG ; Chenghao ZHU ; Yuan JIANG ; Yue ZHANG ; Huairong ZHANG ; Wei ZHANG ; Shengbo ZHAO ; Zhirong SUN
Chinese Journal of Information on Traditional Chinese Medicine 2024;31(7):113-121
Objective To use analytic hierarchy process(AHP)-entropy weight method to evaluate the quality of symbiotic Armillaria in Gastrodia elata Bl.Methods The physiological,growth and chemical indexes of 6 strains of G.elata symbiotic Armillaria were used as evaluation factors,and the weight coefficients of each index were calculated by the AHP-entropy weight method.A comprehensive quality evaluation system was established to evaluate the quality of Armillaria strains,and the results were verified by red G.elata and hybrid G.elata combined planting experiments.Results The quality evaluation results showed that extracellular xylanase activity,extracellular cellulase activity and total sugar weight were relatively high,among which strains N6 and N3 ranked the top.The results showed that strains N5 and N4 combined with red G.elata had better quality,that strains N6 and N3 combined with hybrid G.elata had better quality.Conclusion The correlation of extracellular xylanase activity and total sugar of cellulase activity should be paid attention to in the quality evaluation of symbiotic Armillaria in G.elata.The quality evaluation system constructed in this artilcle is basically consistent with the results of hybrid G.elata combined with hybrid G.elata experiment,which can provide references for the quality screening of symbiotic Armillaria in G.elata.
2.BGB-A445, a novel non-ligand-blocking agonistic anti-OX40 antibody, exhibits superior immune activation and antitumor effects in preclinical models.
Beibei JIANG ; Tong ZHANG ; Minjuan DENG ; Wei JIN ; Yuan HONG ; Xiaotong CHEN ; Xin CHEN ; Jing WANG ; Hongjia HOU ; Yajuan GAO ; Wenfeng GONG ; Xing WANG ; Haiying LI ; Xiaosui ZHOU ; Yingcai FENG ; Bo ZHANG ; Bin JIANG ; Xueping LU ; Lijie ZHANG ; Yang LI ; Weiwei SONG ; Hanzi SUN ; Zuobai WANG ; Xiaomin SONG ; Zhirong SHEN ; Xuesong LIU ; Kang LI ; Lai WANG ; Ye LIU
Frontiers of Medicine 2023;17(6):1170-1185
OX40 is a costimulatory receptor that is expressed primarily on activated CD4+, CD8+, and regulatory T cells. The ligation of OX40 to its sole ligand OX40L potentiates T cell expansion, differentiation, and activation and also promotes dendritic cells to mature to enhance their cytokine production. Therefore, the use of agonistic anti-OX40 antibodies for cancer immunotherapy has gained great interest. However, most of the agonistic anti-OX40 antibodies in the clinic are OX40L-competitive and show limited efficacy. Here, we discovered that BGB-A445, a non-ligand-competitive agonistic anti-OX40 antibody currently under clinical investigation, induced optimal T cell activation without impairing dendritic cell function. In addition, BGB-A445 dose-dependently and significantly depleted regulatory T cells in vitro and in vivo via antibody-dependent cellular cytotoxicity. In the MC38 syngeneic model established in humanized OX40 knock-in mice, BGB-A445 demonstrated robust and dose-dependent antitumor efficacy, whereas the ligand-competitive anti-OX40 antibody showed antitumor efficacy characterized by a hook effect. Furthermore, BGB-A445 demonstrated a strong combination antitumor effect with an anti-PD-1 antibody. Taken together, our findings show that BGB-A445, which does not block OX40-OX40L interaction in contrast to clinical-stage anti-OX40 antibodies, shows superior immune-stimulating effects and antitumor efficacy and thus warrants further clinical investigation.
Mice
;
Animals
;
Receptors, Tumor Necrosis Factor/physiology*
;
Receptors, OX40
;
Membrane Glycoproteins
;
Ligands
;
Antibodies, Monoclonal/pharmacology*
;
Antineoplastic Agents/pharmacology*
3.Comparative effectiveness of different hepatocellular carcinoma screening intervals or modalities: a systematic review and meta-analysis.
Jichun YANG ; Zhirong YANG ; Xueyang ZENG ; Shuqing YU ; Le GAO ; Yu JIANG ; Feng SUN
Chinese Medical Journal 2023;136(11):1322-1330
BACKGROUND:
Current guidelines recommend hepatocellular carcinoma (HCC) screening in high-risk populations. However, the ideal HCC screening interval and screening modality have not been determined. This study aimed to compare the screening efficacy among different modalities with various intervals.
METHODS:
PubMed and other nine databases were searched through June 30, 2021. Binary outcomes were pooled using risk ratio (RR) with 95% confidence intervals (CIs). Survival rates were also pooled using RR with 95% CIs because most eligible studies only provided the number of survival patients instead of hazard ratio.
RESULTS:
In all, 13 studies were included. Two random controlled trials (RCTs) and six cohort studies compared screening intervals for ultrasonography (US) screening and found no significant differences between shorter (3- or 4-month) and longer (6- or 12-month) screening intervals in terms of early HCC proportion, HCC significant mortality, 1-year survival rate; screening at 6-month interval significantly increased the proportion of early HCC (RR = 1.17, 95% confidence interval [CI]: 1.08-1.26) and prolonged the 5-year survival rate (RR = 1.39, 95% CI: 1.07-1.82) relative to the 12-month interval results. Three other RCTs and two cohort studies compared different screening modalities in cirrhosis or chronic hepatitis B, which indicated no statistical differences in the proportion of early HCC (RR = 0.89, 95% CI: 0.40-1.96) and HCC mortality (RR = 0.69, 95% CI: 0.23-2.09) between the biannual US and annual computed tomography (CT screening). Biannual US screening showed a lower proportion of early HCC than biannual magnetic resonance imaging (MRI) (RR = 0.60, 95% CI: 0.37-0.97) and biannual US combined with annual CT (RR = 1.31, 95% CI: 1.13-1.51) screening. The proportion of early HCC in the contrast-enhanced US group was slightly higher than that in the B-mode US (RR = 1.08, 95% CI: 1.00-1.23) group.
CONCLUSIONS:
The evidence suggests that 6 months may be the best HCC screening interval for US screening. The effectiveness of CT and MRI is better than US during same screening intervals. However, MRI and CT are more expensive than US, and CT also can increase the risk of radiation exposure. The selection of CT or MRI instead of US should be carefully considered.
REGISTRATION
No. CRD42020148258 at PROSPERO website ( https://www.crd.york.ac.uk/PROSPERO/ ).
Humans
;
Carcinoma, Hepatocellular/pathology*
;
Liver Neoplasms/pathology*
;
Liver Cirrhosis/complications*
;
Risk Factors
;
Cohort Studies
4.Research progress on fear of dementia
Xiang LONG ; Zhirong JIANG ; Min QING ; Chunhui CHEN ; Lin LONG
Sichuan Mental Health 2022;35(5):483-488
The purpose of this article is to review the research progress on fear of dementia, and to provide references for clinical treatment and nursing care. Fear of dementia is a widespread problem for adults, and adults with high degrees of fear were more likely to develop adverse psychological consequences, including aggravation of anxiety and depression, decreased inclination toward health-promoting behaviours, avoidance of medical treatment, and suicidal ideation. At present, domestic and foreign studies have mainly focused on the current situation and influencing factors of fear of dementia. Therefore, this article gives a review on the fear of dementia in terms of its concept, incidence, impact, influencing factors, assessment tools and intervention measures, with a view to provide a reference for the subsequent studies.
5.Assessment of left atrial volume and function by real-time three-dimensional speckle tracking imaging in end-stage renal disease patients with different dialysis methods
Xiaofei CHEN ; Zhirong JIANG ; Panyu YANG ; Pin SUN ; Xiangqin HE ; Xiaofan WANG ; Qifeng LYU ; Xiaoxia SONG ; Yu TIAN
Chinese Journal of Ultrasonography 2020;29(4):308-313
Objective:To discuss the value of real-time three-dimensional speckle tracking imaging(RT3D-STI) in the evaluation of the left atrial (LA) volume and function in end-stage renal disease (ESRD) patients with different dialysis methods.Methods:Eighty-three ESRD patients who were treated in the Affiliated Hospital of Qingdao University from February to August 2019 were enrolled and divided into non-dialysis group ( n=25), hemodialysis group (HD group, n=31) and peritoneal dialysis group (PD group, n=27). And 30 healthy volunteers were enrolled as control group. Subsequently, the LA volume indexs including LA maximal volume index (LAVImax), LA minimal volume index (LAVImin) and LA presystolic volume index (LAVIpre), the LA function parameters including LA ejection fraction (LAEF), LA passive ejection fraction(LApEF) and LA active ejection fraction (LAaEF) and the LA global strain parameters including global longitudinal strain(GLS), global radial strain(GRS) and global circumferential strain(GCS) were obtained by RT3D-STI. The differences of the parameters among these groups were compared and the correlations between the myocardial strain parameters and dialysis time were analyzed. Results:①The LAVImax, LAVImin and LAVIpre of the non-dialysis group, PD group and HD group were higher than those in the control group, while the LAEF, LApEF, GLS, GRS and GCS were lower than those in the control group(all P<0.05); the LAVImin of the PD group as well as the LAVImin, LAVIpre and LAVImax of HD group were higher than those of non-dialysis group, while the LAEF, LApEF, GLS, GCS of the PD group and the LAEF, LApEF, GLS, GRS, GCS of HD group were lower than those of non-dialysis group (all P<0.05). The LAVImax, LAVImin, LAVIpre of HD group were higher than those of PD group, while the LAEF, LApEF, GLS, GRS and GCS of HD group were lower than those of PD group (all P<0.05). ②The GLS and GCS in PD group were negatively correlated with the dialysis time( r=-0.670, -0.596, all P<0.05), and the GLS, GCS and GRS in HD group were negatively correlated with the dialysis time( r=-0.624, -0.631, -0.551, all P<0.05). Conclusions:RT3D-STI can assess the LA volume and function of ESRD patients with different dialysis methods effectively and can further evaluate the prognosis of patients and guide timely clinical intervention.
6.Dosimetry test of domestically-made accelerator intensity-modulated radiation therapy and volumetric-modulated arc therapy
Dazhen JIANG ; Hui LIU ; Xiaoyong WANG ; Dajiang WANG ; Jiuling SHEN ; Ji CHEN ; Cheng CHEN ; Hongli ZHAO ; Zhirong BAO ; Jun ZHANG
Chinese Journal of Radiation Oncology 2020;29(7):551-553
Objective:To create AAPM TG 119 test plans for intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) in order to evaluate the accuracy of the United Imaging Healthcare′s URT treatment planning system (URT-TPS). The plans were delivered to the phantom using the United Imaging Healthcare′s URT-Linac 506C.Methods:The overall accuracy of IMRT and VMAT planning, measurement, and analysis were evaluated for four test geometries provided by American Association of Physicists in Medicine (AAPM) Task Group Report 119(TG-119) on multi-target, prostate, head and neck and C-shape (easy). The dose distributions were measured in the coronal plane. The point measurements were measured by a Farmer type ion chamber and fluence measurements were completed with film and Delta4 phantom, respectively. Measured planar dose distributions were analyzed using gamma index with criteria 3%/3 mm.Results:For IMRT and VMAT plans, the planning results matched the TG-119 planning results. Measured point doses of IMRT and VMAT were within 2.62% and 3.90% of the planned doses, respectively. Measured film dosimetry gamma values of IMRT and VMAT were> 97.50% and> 93.27%, respectively.Conclusion:Based on these analyses which were performed in line with the TG119 recommendations, it is evident that the URT treatment planning system and URT-Linac 506C have commissioned IMRT and VMAT techniques with adequate accuracy.
7. Assessment of left atrial function in elderly patients with ischemic mitral regurgitation by real-time three-dimensional speckle tracking imaging
Jingxuan JIANG ; Zhirong JIANG ; Xiaofan WANG ; Qifeng LYU ; Xiaoxia SONG ; Yu TIAN
Chinese Journal of Geriatrics 2020;39(1):27-32
Objective:
To assess left atrial(LA)function by evaluating changes of LA wall movement and volume detected by real-time three-dimensional speckle tracking imaging(RT3D-STI)in elderly patients with ischemic mitral regurgitation(IMR).
Methods:
Eighty-six elderly patients with coronary heart disease(CHD)were enrolled in this study.According to whether or not to have IMR, the patients were divided into the pure CHD group(n=32)and the CHD-induced ischemic mitral regurgitation(IMR)group(n=54, including 20 cases of mild IMR, 18 cases of moderate IMR and 16 cases of severe IMR). Thirty-two healthy elderly volunteers were considered as control group.RT3D-STI was used to evaluate the global atrial longitudinal strain(GLS), global circumferential strain(GCS), global radial strain(GRS)and LA maximal, minimal and pre-systolic volumes(LAVmax, LAVmin, and LAVp). LA ejection fraction(LAEF), LA passive ejection fraction(LApEF)and LA active ejection fraction(LAaEF)were calculated.The relationship of LA volume changes and myocardial strain with LA function was analyzed.
Results:
The left ventricular ejection fraction(LVEF)and LAEF were reduced in CHD group and IMR group as compared with the control group, and were lower in IMR group than in CHD group(
8.Implantable sandwich PHBHHx film for burst-free controlled delivery of thymopentin peptide.
Ke PENG ; Chengyu WU ; Guoxu WEI ; Jinghui JIANG ; Zhirong ZHANG ; Xun SUN
Acta Pharmaceutica Sinica B 2018;8(3):432-439
Sustained release and non-parental formulations of peptides and protein drugs are highly desirable because of enhanced therapeutic effects as well as improved patient compliance. This is especially true for small peptides such as thymopentin (TP5). To this end, implantable sandwich poly (hydroxybutyrate--hydroxyhexanoate) (PHBHHx) films were designed to prolong release time and to inhibit burst release phenomenon of TP5 by a simple volatilization method. release studies revealed that sandwich films had nearly no burst release. release time of sandwich films was prolonged to 42 days. Pharmacodynamic evaluation demonstrated that TP5 sandwich films significantly increased survival rates in a rat immunosuppressive model and normalized CD4/CD8 values. These results suggest that TP5 released from sandwich films can attenuate cyclophosphamide's immunosuppressive activity, and possibly achieve results comparable to daily TP5 injection therapy. Thus, sandwich PHBHHx films show excellent potential as a sustained, burst-free release system for small molecular weight, hydrophilic peptide drugs.
9.Operative treatment of complex fractures of midshaft clavicle using a locking plate: a comparison be-tween mini-invasive plate osteosynthesis ( MIPO ) and conventional open reduction
Langqing ZENG ; Lulu ZENG ; Yunfeng CHEN ; Yuwen JIANG ; Hui YANG ; Zhirong LIN ; Peng ZHAN ; Yuanhui LI
Chinese Journal of Orthopaedic Trauma 2018;20(1):68-72
Objective To compare the clinical outcomes of mini-invasive plate osteosynthesis ( MIPO ) and conventional open plating for complex fractures of midshaft clavicle. Methods The authors retrospec-tively reviewed the data of complex fractures of midshaft clavicle ( AO/OTA types 15-B2 and 15-B3 ) which had been treated with MIPO or conventional open plating between January 2010 to February 2016. Forty-one patients were treated with MIPO and 43 with conventional open plating. The 2 groups were compared in terms of incision length, hospital stay, bone union time, postoperative Constant score and Disabilities of the Arm, Shoulder and Hand ( DASH ) score, patients'satisfaction and complications. Results The average follow-up was 21. 2 ± 9. 2 months for MIPO group and 23. 1 ± 11. 8 months for conventional open plating group. The incision length ( 4. 3 ± 0. 5 cm ) , hospital stay ( 7. 7 ± 1. 9 d ) and union time ( 10. 6 ± 3. 2 w ) in the MIPO group were signifi-cantly shorter than those in the conventional open plating group ( 8. 4 ± 1. 3 cm, 9. 6 ± 3. 1 d and 12. 3 ± 3. 9 w, respectively ) ( P <0. 05 ) . The MIPO group had significantly lower incidences of hypertrophic scarring and dysesthesia in the area of incision but significantly higher patients'satisfaction than the conventional open plating group ( P <0. 05 ) . There were no significant differences in the Constant score or DASH score at 3 months, 6 months and the final follow-up ( P > 0. 05 ) . Conclusion In the treatment of complex fractures of midshaft clavicle, although both MIPO and conventional open plating can lead to similar functional outcomes, MIPO may be advantageous over conventional open plating in smaller surgical incision, more rapid fracture union, shorter hospital stay and higher patients'satisfaction.
10.A new type of anatomical locking plate for split fractures of humeral greater tuberosity
Langqing ZENG ; Yuwen JIANG ; Lulu ZENG ; Zhirong LIN ; Yuanhui LI ; Peng ZHAN ; Yang XIANG ; Wei YU ; Longxiang SHEN ; Yunfeng CHEN
Chinese Journal of Orthopaedic Trauma 2018;20(9):743-749
Objective To evaluate the clinical outcomes of split fractures of humeral greater tuberosity treated by our self-designed new type of anatomical locking plate.Methods From September 2012 to February 2017,23 patients were treated for acute split fracture of the humeral greater tuberosity using our self-designed new type of anatomical locking plate.They were 13 males and 10 females with a mean age of 52.8 years (range,from 25 to 81 years).Of them,6 were beyond 60 years old, 12 had comminuted fracture,10 were complicated with glenohumeral dislocation,and 12 with rotator cuff tear.The patients were evaluated clinically with Constant-Murley score,visual analog scale (VAS),range of motion and complications at the last follow-ups.Results This series were followed up for 12 to 30 months (mean,23.2 months).All the fractures healed after an average time of 10.6 weeks (range,from 8 to 12 weeks).Their mean Constant-Murley Score was 92.1 points (range,from 70 to 100 points),giving an excellent and good rate of 95.7% (22/23);their VAS scores averaged 0.8 points (range,from 0 to 4 points).Their forward flexion averaged 160.6°,abduction 157.8°,external rotation 46.4°,and internal rotation up to the T11 level,respectively.Their complications rate was 17.4% (4/23).One case of axillary nerve injury,one case of relapse of glenohumeral dislocation at sports,and 2 cases of stiff shoulder were observed.Conclusion Split fractures of the humeral greater tuberosity can be successfully treated with our new type of anatomical locking plate which serves as a new alternative treatment.

Result Analysis
Print
Save
E-mail