1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
6.Interpretation of the World Health Organization global report on hypertension 2023
Qin SUN ; Weifan TIAN ; Tingting LUO ; Jing YU ; Dongze LI ; Haihong ZHANG ; Rui ZENG ; Zhi WAN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2024;31(02):203-208
		                        		
		                        			
		                        			The World Health Organization (WHO) released the “Global report on hypertension” on September 19, 2023. This report systematically summarizes the prevalence, mortality, diagnosis and treatment of hypertension in various countries, and elucidates the current situation of hypertension management, and gives a series of suggestions on how to manage hypertension, providing new thinking and inspiration for countries to optimize hypertension management. Through the summary of relevant studies and reports, this paper further reviews the present situation, early identification and management of hypertension.
		                        		
		                        		
		                        		
		                        	
7.Application of droplet digital PCR in etiological diagnosis of severe acute pancreatitis patients with suspected bloodstream infection
Xin-Yu WANG ; Gang LI ; Wen-Jian MAO ; Jie YANG ; Jing-Zhu ZHANG ; Lu KE ; Wei-Qin LI ; Zhi-Hui TONG
Chinese Journal of Infection Control 2024;23(1):9-15
		                        		
		                        			
		                        			Objective To explore the value of droplet digital polymerase chain reaction(ddPCR)in the etiological diagnosis of severe acute pancreatitis(SAP)patients with suspected bloodstream infection(BSI).Methods SAP patients admitted to the department of critical care medicine in a hospital July to September 2022 were enrolled.When BSI was suspected,venous blood was collected for both ddPCR detection and blood culture(BC)with antimi-crobial susceptibility testing(AST)simultaneously.The time required for two detection methods was recorded,and the detection results of ddPCR and BC were compared.The etiological diagnostic efficacy of ddPCR was calculated,and the correlation between the value of pathogen load detected by ddPCR and the level of infection parameters was explored.Results A total of 22 patients were included in the analysis,and 52 venous blood specimens were collec-ted for detection.BC revealed 17 positive specimens(32.7%)and 29 pathogenic strains,while ddPCR showed 41 positive specimens(78.8%)and 73 pathogenic strains.Detection time required for ddPCR was significantly lower than that of BC([0.16±0.03]days vs[5.92±1.20]days,P<0.001).Within the detection range of ddPCR and taking BC results as the gold standard,the sensitivity and specificity of ddPCR were 80.0%and 28.6%,respective-ly.With the combined assessment of BSI based on non-blood specimen microbial evidence within a week,the sensi-tivity and specificity of ddPCR detection increased to 91.9%and 76.9%,respectively.ddPCR detected resistance genes of blaKPC,blaNDM/IMP,VanA/VanM,and mecA from 19,9,6,and 5 specimens,respectively.Correlation analysis showed a positive correlation between pathogen load and levels of C-reactive protein as well as procalcitonin(r=0.347,0.414,P<0.05).Conclusion As a supplementary detection method for BC in BSI diagnosis,ddPCR has the advantages of higher sensitivity and shorter detection time,and is worthy of further exploration in clinical application.
		                        		
		                        		
		                        		
		                        	
8.Development and in vivo biomechanics of goat mobile artificial lumbar spine complex
Feng ZHANG ; Xi-Jing HE ; Jian-Tao LIU ; Rui WANG ; Jie QIN ; Quan-Jin ZANG ; Ting ZHANG ; Zhi-Yu LIU
China Journal of Orthopaedics and Traumatology 2024;37(3):281-287
		                        		
		                        			
		                        			Objective Mobile artificial lumbar complex(MALC)which suitable for reconstruction after subtotal lumbar resection in goats was developed,and to test stability of the complex and postoperative lumbar segmental motor function.Methods Eighteen male boer goats aged from 1 to 2 years old(weighted from 35 to 45 kg)were selected and divided into con-trol group,fusion group and non-fusion group,with 6 goats in each group.According to preoperative CT scans and MRI exami-nations of lumbar,the goat MALC was designed and performed by 3D printed for non-fusion group.Operation was performed on three groups respectively,and only vertebral body and disc were exposed in control group.In fusion group,L4 part of vertebral body and the upper and lower complete disc tissues were removed,and the lumbar spine bone plate fixation was performed with titanium mesh bone grafting.In non-fusion group,vertebral body and disc were removed in the same way,and MALC was im-planted.AP and lateral X-rays of lumbar vertebrae in goat were taken at 6 months after surgery,in order to understand whether the plant was dislocated,displaced and fractured.Biomechanical tests were performed on the specimens by mechanical instru-ment to measure range of motion(ROM)of L2,3,L,4,L4,5intervertebral space and the overall ROM of L2-5 lumbar vertebrae.Results MALC of lumbar vertebra was designed by 3D printing,and its component artificial vertebrae and upper and lower ar-tificial end plates were manufactured.The semi-spherical structure was fabricated by precision lathe using high-crosslinked polyethylene material,and the prosthesis was assembled.Postoperative AP and lateral X-rays of lumbar vertebra at 6 months showed the implant position of implant and MALC were good without displacement and dislocation.In vitro biomechanical test of lumbar vertebrae specimens:(1)There were no statistical significance in ROM of lumbar intervertebral space flexion and extension,lateral flexion and rotation on L.4 and L4,5,between non-fusion group and control group(P>0.05),while ROM of fu-sion group was significantly reduced compared with the other two groups(P<0.05).There were no significant difference in ROM of L2.3 intervertebral flexion and extension,lateral flexion and rotation between non-fusion group and control group(P>0.05),while fusion group was significantly increased compared with the other two groups(P<0.001).(2)There was no signifi-cant difference in overall lumbar ROM of L2-5(P>0.05).Conclusion The individual MALC could restore intervertebral height of lumbar vertebra while maintaining the stability of lumbar vertebra and re-establishing motor function of lumbar space.
		                        		
		                        		
		                        		
		                        	
9.Nanodrug Delivery System: a Promising Targeting Strategy for Treatment of Pancreatic Ductal Adenocarcinoma
Ji-Miao ZHANG ; Zhi-Qin WANG ; Yi-Ye LI ; Guang-Jun NIE
Progress in Biochemistry and Biophysics 2024;51(10):2661-2676
		                        		
		                        			
		                        			Pancreatic ductal adenocarcinoma (PDAC) is a highly malignant solid tumor of the digestive system, characterized by rapid progression and difficulties of early diagnosis. Five-year survival rate of the patients is less than 9%. With the acceleration of global population aging and lifestyle change, the incidence of PDAC has been increasing annually. Currently, surgical treatment and chemotherapy remain the standard treatment options for PDAC patients. Early symptoms of PDAC are so undetectable that most patients miss the optimal opportunity for radical surgical resection. Even among those who undergo surgery, the high recurrence rate remains a major problem. PDAC is known for its unique tumor microenvironment. The cellular and non-cellular components in the tumor microenvironment account for as much as 90% of the tumor stroma, presenting many potential targets for PDAC therapy. Activated pancreatic stellate cells within PDAC tissue express specific proteins and secrete various cytokines and metabolites, which directly contribute to the proliferation, invasion, and metastasis of PDAC cells. These elements are critical in extracellular matrix production, connective tissue hyperplasia, immune tolerance, and drug resistance. Immune cells, such as macrophages and neutrophils, exert immunosuppressive and tumor-promoting roles in PDAC progression. The extracellular matrix, which serve as a natural physical barrier, induces interstitial hypertension and reduces blood supply, thereby hindering the delivery of drugs to the tumor. Additionally, it helps the metastasis and differentiation of PDAC cells, reducing the efficacy of clinical chemotherapy and immunotherapy. Although chemotherapeutic agents like gemcitabine have been used in the clinical treatment of PDAC for more than 20 years, the curative effect is obstructed by their poor stability in the bloodstream, low cellular uptake, and poor targeting. While small-molecule inhibitors targeting mutations such as KRASG12C, BRCA, and NTRK fusion have shown great potential for molecular targeted treatments and gene therapies of PDAC, their broader application is limited by side effects and restricted scope of patients. The advancement of nanotechnology brings new strategies for PDAC treatment. By virtue of unique size characteristics and actual versatility, different drug-delivery nanosystems contribute to overcome the dense stromal barrier, prolong the circulation time of therapeutics and realize precise PDAC treatment by targeted drug delivery. Clinical nanodrugs such as albumin-bound paclitaxel (nab-paclitaxel) and irinotecan liposome greatly improve the pharmacokinetics of conventional chemotherapeutics and promote drug accumulation inside the tumor, thereby are applying to the first-line treatment of PDAC. It is noteworthy that none nanodrugs with active targeting design have been approved for clinical treatment yet, though many are in clinical trials. In this review, we discuss promising targeting strategies based on different nanodrug delivery systems for treatment of PDAC. One major nanostrategy focuses on the tumor cell targeting and its applications in chemotherapy, molecular targeting therapy, gene therapy, and immunotherapy of PDAC. Another nanostrategy targets the tumor microenvironment, which highlights the nanosystems specifically regulating pancreatic stellate cells, immune cells and the extracellular matrix. Recent progress of developing new nanotheraputics for breakthrough in the fight of PDAC are elaborated in this review. We also provide our perspectives on the challenges and opportunities in the field. 
		                        		
		                        		
		                        		
		                        	
10.RNA SNP Detection Method With Improved Specificity Based on Dual-competitive-padlock-probe
Qin-Qin ZHANG ; Jin-Ze LI ; Wei ZHANG ; Chuan-Yu LI ; Zhi-Qi ZHANG ; Jia YAO ; Hong DU ; Lian-Qun ZHOU ; Zhen GUO
Progress in Biochemistry and Biophysics 2024;51(11):3021-3033
		                        		
		                        			
		                        			ObjectiveThe detection of RNA single nucleotide polymorphism (SNP) is of great importance due to their association with protein expression related to various diseases and drug responses. At present, splintR ligase-assisted methods are important approaches for RNA direct detection, but its specificity will be limited when the fidelity of ligases is not ideal. The aim of this study was to create a method to improve the specificity of splintR ligase for RNA detection. MethodsIn this study, a dual-competitive-padlock-probe (DCPLP) assay without the need for additional enzymes or reactions is proposed to improve specificity of splintR ligase ligation. To verify the method, we employed dual competitive padlock probe-mediated rolling circle amplification (DCPLP-RCA) to genotype the CYP2C9 gene. ResultsThe specificity was well improved through the competition and strand displacement of dual padlock probe, with an 83.26% reduction in nonspecific signal. By detecting synthetic RNA samples, the method demonstrated a dynamic detection range of 10 pmol/L-1 nmol/L. Furthermore, clinical samples were applied to the method to evaluate its performance, and the genotyping results were consistent with those obtained using the qPCR method. ConclusionThis study has successfully established a highly specific direct RNA SNP detection method, and provided a novel avenue for accurate identification of various types of RNAs. 
		                        		
		                        		
		                        		
		                        	
            
Result Analysis
Print
Save
E-mail