1.Application of Suture Traction Suspension Method in Anterior Chest Approach Endoscopic Thyroid Cancer Radical Surgery
Zhenhua ZHOU ; Xiping LIU ; Ke SUN
Chinese Journal of Minimally Invasive Surgery 2024;24(1):19-24
Objective To explore the application value of suture traction suspension method in endoscopic thyroid cancer radical surgery through the anterior chest approach.Methods A retrospective analysis was made on 108 cases of papillary thyroid cancer from January 2020 to December 2022,who underwent unilateral lobectomy and ipsilateral central lymph node dissection through anterior chest approach.After May 2021,the suture traction and suspension method was gradually carried out by using 2-0 polypropylene suture to suspend the muscles,trachea,and thyroid gland lobes.There were 51 cases in the suture traction suspension group and 57 cases in the conventional endoscopic group.The intraoperative and postoperative indicators were compared between the two groups.Results The surgery was successfully completed in both groups.As compared to the conventional endoscopic group,the suture traction suspension group had shorter surgical time for thyroidectomy[(35.3±7.3)min vs.(43.4±8.4)min,t =-5.342,P<0.001],shorter surgical time for central lymph node dissection[(20.1±3.5)min vs.(27.7±4.9)min,t =-9.271,P<0.001],less intraoperative bleeding[10(5-15)ml vs.15(5-30)ml,Z =-6.250,P<0.001],and more central lymph nodes dissected[8(3-13)vs.6(4-10),Z =3.272,P =0.001].There were fewer cases of transient recurrent laryngeal nerve injury after surgery in the suture traction suspension group,but no statistical significance was noted(1 case vs.8 cases,χ2 =3.678,P =0.055).There were no statistically significant differences in postoperative hospitalization time,postoperative lymph leakage,parathyroid gland detection in postoperative specimens,postoperative hypoparathyroidism,postoperative pain score,and postoperative cosmetic effect score between the two groups(P>0.05).Conclusion Suture traction suspension method can shorten surgical time,reduce intraoperative bleeding,reduce the occurrence of recurrent laryngeal nerve injury,and increase the number of central lymph node dissection.
2.3D CT reconstruction for diagnosis of chronic lateral ankle instability combined with syndesmotic diastasis
Ke FU ; Jingjing ZHAO ; Cheng HAO ; Wei XIE ; Shiwei LIN ; Chenyu XU ; Zhenhua FANG
Chinese Journal of Orthopaedic Trauma 2024;26(10):865-871
Objective:To investigate the value of 3D CT reconstruction in diagnosis of chronic lateral ankle instability (CLAI) combined with syndesmotic diastasis (SD).Methods:A retrospective study was conducted to analyze the clinical data of 160 patients with CLAI who had been examined by arthroscopy from January 2018 to September 2022 at Department of Foot and Ankle Surgery, Wuhan Fourth Hospital. There were 64 males and 96 females with an age of (39.8±12.6) years. Eighty-one left and 79 right feet were affected; the time from injury to surgery was (27.3±11.6) months. The patients were divided into a widened interval group and a normal interval group according to the syndesmotic width measured, with 2 mm as a critical value. After preoperative 3D CT reconstruction, the differences in anterior tibiofibular distance, posterior tibiofibular distance, the narrowest tibiofibular distance, fibular translation, fibular rotation, and syndesmotic area (SA) were compared between the 2 groups. Univariate and multivariate analyses were performed successively to identify the risk factors. The receiver operating characteristic (ROC) curve was used to identify the best predictive factor and critical value. According to the findings of previous research, the above analyses were repeated to determine the best predictive factor and critical value respectively in the sex subgroup, fibular morphology subgroup and incisura feature subgroup.Results:The binary logistic regression showed that SA was a risk factor for CLAI combined with SD ( OR=1.196, 95% CI: 1.122 to 1.275, P < 0.001). The ROC curve revealed an area under curve of 0.847 and the difference critical value of 22.06 mm 2 that indicated a sensitivity of 80.4% and a specificity of 78.9%, respectively. Subgroup analyses showed that SA was suitable for male and female patients and patients with different fibular morphologies and incisura features but the difference critical values were different. Conclusion:In 3D CT reconstruction, measurement of SA may help the diagnosis of CLAI combined with SD.
3.Safety of early antiplatelet therapy for non-cardioembolic mild stroke patients with thrombocytopenia
Dongjuan XU ; Huan ZHOU ; Mengmeng HU ; Yilei SHEN ; Hongfei LI ; Lianyan WEI ; Jing XU ; Zhuangzhuang JIANG ; Xiaoli SHAO ; Zhenhua XI ; Songbin HE ; Min LOU ; Shaofa KE
Journal of Zhejiang University. Medical sciences 2024;53(2):175-183
Objective:To investigate the safety of early antiplatelet therapy for non-cardioembolic mild stroke patients with thrombocytopenia.Methods:Data of acute ischemic stroke patients with baseline National Institutes of Health Stroke Scale(NIHSS)score≤3 and a platelet count<100×109/L were obtained from a multicenter register.Those who required anticoagulation or had other contraindications to antiplatelet therapy were excluded.Short-term safety outcomes were in-hospital bleeding events,while the long-term safety outcome was a 1-year all-cause death.The short-term neurological outcomes were evaluated by modified Rankin scale(mRS)score at discharge.Results:A total of 1868 non-cardioembolic mild stroke patients with thrombocytopenia were enrolled.Multivariate regression analyses showed that mono-antiplatelet therapy significantly increased the proportion of mRS score of 0-1 at discharge(OR=1.657,95%CI:1.253-2.192,P<0.01)and did not increase the risk of intracranial hemorrhage(OR=2.359,95%CI:0.301-18.503,P>0.05),compared with those without antiplatelet therapy.However,dual-antiplatelet therapy did not bring more neurological benefits(OR=0.923,95%CI:0.690-1.234,P>0.05),but increased the risk of gastrointestinal bleeding(OR= 2.837,95%CI:1.311-6.136,P<0.01)compared with those with mono-antiplatelet therapy.For patients with platelet counts≤75×109/L and>90×109/L,antiplatelet therapy significantly improved neurological functional outcomes(both P<0.05).For those with platelet counts(>75-90)×109/L,antiplatelet therapy resulted in a significant improvement of 1-year survival(P<0.05).For patients even with concurrent coagulation abnormalities,mono-antiplatelet therapy did not increase the risk of various types of bleeding(all P>0.05)but improved neurological functional outcomes(all P<0.01).There was no significant difference in the occurrence of bleeding events,1-year all-cause mortality risk,and neurological functional outcomes between aspirin and clopidogrel(all P>0.05).Conclusions:For non-cardioembolic mild stroke patients with thrombocytopenia,antiplatelet therapy remains a reasonable choice.Mono-antiplatelet therapy has the same efficiency as dual-antiplatelet therapy in neurological outcome improvement with lower risk of gastrointestinal bleeding.
4.Analysis on related factors for internal fixation failure in proximal femoral nail antirotation for treating intertrochanteric fracture
Xian WANG ; Ke SUN ; Zhenhua LIN ; Bin LIANG
Chongqing Medicine 2024;53(8):1226-1230
Objective To investigate the risk factors of internal fixation failure in proximal femoral nail antirotation (PFNA) for treating intertrochanteric fracture.Methods The imageological data of 179 patients with intertrochanteric fracture receiving PFNA internal fixation were analyzed retrospectively.The univariate analysis was adopted to analyze the influence of the gender,degree of osteoporosis,AO/OTA fracture type,top apex distance (TAD),postoperative coxa vara,lateral wall state,fracture reduction situation and screw blade position on the internal fixation failure.The logistic regression model was constructed.The risk factors of internal fixation failure were analyzed.Results Among 179 patients,the internal fixation failure occurred in 16 cases.The univariate analysis showed the AO/OTA fracture type,TAD,postoperative coxa vara,lateral wall state,fracture reduction effect and screw blade location were related with the internal fixation failure (P<0.05).The logistic regression analysis prompted that postoperative coxa vara (OR=6.97,95%CI:2.24-21.68,P=0.001) and the lateral wall breakage (OR=3.08,95%CI:1.03-9.22,P=0.045) were the risk factors of internal fixation failure in femoral intertrochanteric fracture.Conclusion Coxa vara and lateral wall breakage are the risk factors of internal fixation failure in PENA for treating femoral intertrochanteric fracture,and the operation reduction should avoid the coxa vara appearance.
5.Research advances on pelvic floor deformation characteristics and biomechanical axial in apical suspension
Haifeng WANG ; Han LIN ; Zhenhua GAO ; Kunbin KE ; Jihong SHEN
Journal of Modern Urology 2023;28(11):998-1001
Female pelvic organ prolapse (POP) is caused by damage or loss of pelvic floor support, resulting in displacement of the pelvic organs, which leads to abnormalities in the position and function of the organs, mainly due to damage to the pelvic floor mechanical support structures caused by transvaginal birth, loss of elasticity of the pelvic floor mechanical support structures in old women, and loss of the ability to maintain the pelvic floor. The key to POP surgery is the repair of the apical vagina, but treatment based on this theory has failed to achieve satisfactory clinical outcomes. This article will analyze the common procedures of apical suspension in the treatment of mid-pelvic prolapse from the perspective of pelvic floor morphological features and pelvic floor biomechanics axially.
6.Evaluation of the efficacy of TIPS in 27 patients with hepatic sinus obstruction syndrome in the near and medium term
Lei WANG ; Yu ZHANG ; Xiuqi WANG ; Zhendong YUE ; Zhenhua FAN ; Yifan WU ; Fuquan LIU ; Jian DONG ; Ke ZHANG ; Li JIANG ; Huiguo DING ; Yuening ZHANG
Chinese Journal of Hepatology 2023;31(8):842-846
Objective:intrahepatic portocaval shunt (TIPS) in the treatment of hepatic sinusoidal obstruction syndrome (HSOS).Methods:A retrospective analysis was performed on 27 patients with HSOS who were treated with TIPS in our center from July 2018 to July 2020. The changes of portal vein pressure (PVP), portal vein pressure gradient (PPG) and liver function were observed, so as to evaluate the efficacy. Paired t test was adopted to evaluate the quantitative parameters, while χ2 test was used to analyze qualitative parameters, with P < 0.05 as statistical difference. Results:PVP decreased from (4.41 ± 0.18) kPa before shunt to (2.69 ± 0.11) kPa after shunt ( t = 82.41, P < 0.001), PPG decreased from (3.23 ± 0.18) kPa before shunt to (1.46 ± 0.23) kPa after shunt ( t = 32.41, P < 0.001). The liver function improved significantly after operation. After 24 months of follow-up, 3 patients developed stent restenosis and recanalized after balloon dilation. Three patients developed hepatic encephalopathy, which was improved after drug treatment. One patient underwent liver transplantation due to liver failure. Conclusion:TIPS is effective in the treatment of HSOS in the short and medium term, and can provide time for liver transplantation patients to wait for liver source.
7.Effect of intrahepatic veno-venous communications on the consistency of hepatic venous pressure gradient and portal vein pressure gradient
Mingming MENG ; Qingkun SONG ; Fan YANG ; Zhendong YUE ; Lei WANG ; Hongwei ZHAO ; Zhenhua FAN ; Yifan WU ; Yu ZHANG ; Chengbin DONG ; Ke ZHANG ; Li JIANG ; Huiguo DING ; Yuening ZHANG ; Fuquan LIU
Chinese Journal of General Surgery 2022;37(6):414-419
Objective:By using balloon occlusive hepatic angiography in cirrhotic portal hypertension to evaluate contrast doses on the detection rate of intrahepatic venous-lateral branch shunt (HVVC), and the effect on hepatic venous pressure gradient (HVPG) and portal vein pressure gradient (PPG).Methods:From Jan 2018 to Jun 2021, 131 patients received transjugular intrahepatic portosystemic shunt (TIPS) at Beijing Shijitan Hospital.Results:A positive correlation between PVP and weged hepatic venous pressure (WHVP) ( r=0.241, P=0.001) was found when only by right hepatic vein approach. Ten ml of iodine contrast medium when compared to 5ml doses found more cases of intrahepatic venous-venous lateral branch shunt. The mean PPG of patients with HVVC was significantly higher than the mean of HVPG( P<0.05).The right hepatic vein was the only reliable vein by which WHVP was measured. Conclusions:Right hepatic vein manometry,adequate ballon occlusion and using 10ml of iodine contrast help get reliable WHVP and found HVVC; HVVC can affect the consistency of HVPG and PPG.
8.Current status and prospect of biomarker research for schizophrenia
Mengyuan ZHU ; Qing CHEN ; Dan LI ; Mengxia WANG ; Renyu WANG ; Yuxin ZHU ; Weifeng JIN ; Shuzi CHEN ; Ping LI ; Zhenhua LI ; Peijun MA ; Shuai LIU ; Qiong GAO ; Xiaoyan LOU ; Jie XU ; Lili ZHU ; Ling ZHAO ; Kangyi LIANG ; Jinghong CHEN ; Xunjia CHENG ; Ke DONG ; Xiaokui GUO ; Qingtian LI ; Yun SHI ; Junyu SUN ; Huabin XU ; Ping LIN
Chinese Journal of Laboratory Medicine 2022;45(11):1191-1196
Schizophrenia is a serious mental disease. The diagnosis of schizophrenia so far relies heavily on subjective evidence, including self-reported experiences by patients, manifestations described by relatives, and abnormal behaviors assessed by psychiatrists. The diagnosis, monitoring of the disease progression and therapy efficacy assessment are challenging due to the lack of established laboratory biomarkers. Based on the current literature, clinical consensus, guidelines, and expert recommendations, this review highlighted evidence-based potential laboratory biomarkers for the diagnosis of schizophrenia, including genetic biomarkers, neurotransmitters, neurodevelopmental-related proteins, and intestinal flora, and discussed the potential future directions for the application of these biomarkers in this field, aiming to provide an objective basis for the use of these biomarkers in the early and accurate diagnosis, treatment, and prognosis and rehabilitation assessment of schizophrenia.
9.Study on the correlation between PPG and HVPG in patients with portal hypertension
Lei WANG ; Qingkun SONG ; Zhendong YUE ; Hongwei ZHAO ; Zhenhua FAN ; Yifan WU ; Fuquan LIU ; Mingming MENG ; Ke ZHANG ; Li JIANG ; Huiguo DING ; Yuening ZHANG
Chinese Journal of Hepatology 2022;30(7):722-727
Objective:To explore the correlation between portal vein pressure gradient (PPG) and hepatic vein pressure gradient (HVPG) in patients with portal hypertension (PHT).Methods:752 cases with portal hypertension (PHT) who underwent transjugular intrahepatic portosystemic shunt (TIPS) and met the enrollment criteria between January 2016 to December 2019 were analyzed for hepatic vein, inferior vena cava and portal vein pressure. Paired t-test was used for analysis. Pearson correlation test was used to estimate correlation coefficient and coefficient of determination. P<0.05 were considered statistically significant. Results:Wedged hepatic vein pressure (WHVP), portal vein pressure (PVP), correlation coefficient, and coefficient of determination were 27.98±8.95 mmHg, 33.85±7.33 mmHg, 0.329 ( P<0.001), and 0.108, respectively. HVPG, PPG,correlation coefficient, and coefficient of determination were 16.84±7.97 mmHg, 25.11±6.95 mmHg ( P<0.001), 0.145, and 0.021 ( P<0.001), respectively. The difference between HVPG and PPG was greater than 5 mmHg in 524 cases, accounting for 69.7%. The difference between HVPG and PPG was within 5 mmHg or basically equal in 228 cases, accounting for 30.3%. The correlation coefficient between free hepatic venous pressure (FHVP) and inferior vena cava pressure (IVCP) was 0.568 ( P<0.001), and the coefficient of determination was 0.323. According to the presence or absence of hepatic venous collaterals after balloon occluded hepatic angiography, they were divided into two groups: 157 (20.9%) cases in the group with hepatic venous collaterals, and 595 (79.1%) cases in the group without hepatic venous collaterals. The parameters of the two groups were compared: WHVP (15.73±3.63) mmHg vs. (31.22±6.90) mmHg, P<0.001; PVP (31.69±8.70) mmHg vs. (34.42±6.81) mmHg, P<0.001; HVPG (7.18±4.40) mmHg vs. (19.40±6.62) mmHg, P<0.001; PPG (24.24±8.11) mmHg vs. (25.34±6.60) mmHg, P<0.001; free hepatic venous pressure (FHVP) (8.58±3.37) mmHg vs. (11.82±5.07) mmHg , P<0.001; inferior vena cava pressure (IVCP) (7.45±3.29) mmHg vs. (9.09±4.14) mmHg, P<0.001. Conclusion:The overall correlation is poor between HVPG and PPG. HVPG of most patients is not an accurate representation of PPG, and the former is lower than the latter. Hepatic venous collateral formation is one of the important reasons for the serious underestimation of HVPG values.
10.Evaluation of the performance of systems for whole blood C-reactive protein detection: a multi-center study
Juan CHENG ; Huaiyuan LI ; Haipeng LIU ; Yuxin WANG ; Jin XU ; Shangyang SHE ; Wei QU ; Yidong WU ; Guixia LI ; Junmei YANG ; Liya MO ; Yun XIANG ; Jiangwei KE ; Liyue KUI ; Lei ZHENG ; Hongbing CHEN ; Zhili YANG ; Xin LYU ; Hong ZHANG ; Zhenhua TANG ; Lijuan MA ; Hongquan LUO ; Xiangyang LI ; Wenli ZHANG ; Hui JIA ; Huiming YE ; Lijun TIAN ; Qiuhui PAN
Chinese Journal of Laboratory Medicine 2021;44(7):633-643
Objective:To explore the performance of the commonly used whole blood C-reactive protein (CRP) detection systems and give related recommendation on the performance requirements of detection systems.Methods:A total of 7 540 venous blood samples from 26 maternal, child and children′s hospitals were collected to conduct this multi-center study on the analytical performance of 5 commonly used whole blood CRP detection systems from March to April in 2019. The blank check, carryover, repeatability, intermediate precision, linearity, sample stability, influence of hematocrit/triglyceride/bilirubin, comparison with SIEMENS specific protein analyzer and trueness were evaluated. The 5 systems included BC-5390CRP autohematology analyzer, AstepPLUS specific protein analyzer, Ottoman-1000 Automated Specific Protein POCT Workstation, i-CHROMA Immunofluorometer equipment Reader and Orion QuikRead go detecting instrument. The 5 systems were labeled as a, b, c, d and e randomly.Results:Within the 5 systems, all values of blank check were less than 1.00 mg/L, the carryovers were lower than 1.00%. The repeatability of different ranges of CRP concentrations including 3.00-10.00, 10.00-30.00 and>30.00 mg/L were less than 10.00%, 6.00% and 5.00%, respectively, and the intermediate precision was less than 10.00%. The linearity correlation coefficients of the 5 systems were all above 0.975, while the slope was within 0.950-1.050. Whole blood samples were stable within 72 hours both at room temperature (18-25 ℃) and refrigerated temperature (2-8 ℃). The CRP results were rarely influenced by high triglyceride or bilirubin, except for the immmunoturbidimetric test based on microparticles coated with anti-human CRP F(ab) 2 fragments. When triglyceride was less than 15.46 mmol/L, the deviation of CRP was less than 10.00%. When bilirubin was less than 345.47 μmol/L, the deviation of CRP was less than 10.00%. CRP was more susceptible to Hct on the systems without Hct correction. The deviation of CRP between different Hct dilution concentration and 40% dilution concentration can reach as high as 67.48%. The correlation coefficients ( r) of 5 systems were all more than 0.975 in the range of 0-300.00 mg/L compared with Siemens specific protein analyzer. All systems passed the trueness verification using the samples with specified values of 12.89 and 30.60 mg/L. Conclusion:The performance of 5 systems can basically meet the clinical needs, but it is suggested that the whole blood CRP detection system without automatic Hct correction should be modified manually.

Result Analysis
Print
Save
E-mail