1.The Near-infrared II Emission of Gold Clusters and Their Applications in Biomedicine
Zhen-Hua LI ; Hui-Zhen MA ; Hao WANG ; Chang-Long LIU ; Xiao-Dong ZHANG
Progress in Biochemistry and Biophysics 2025;52(8):2068-2086
		                        		
		                        			
		                        			Optical imaging is highly valued for its superior temporal and spatial resolution. This is particularly important in near-infrared II (NIR-II, 1 000-3 000 nm) imaging, which offers advantages such as reduced tissue absorption, minimal scattering, and low autofluorescence. These characteristics make NIR-II imaging especially suitable for deep tissue visualization, where high contrast and minimal background interference are critical for accurate diagnosis and monitoring. Currently, inorganic fluorescent probes—such as carbon nanotubes, rare earth nanoparticles, and quantum dots—offer high brightness and stability. However, they are hindered by ambiguous structures, larger sizes, and potential accumulation toxicity in vivo. In contrast, organic fluorescent probes, including small molecules and polymers, demonstrate higher biocompatibility but are limited by shorter emission wavelengths, lower quantum yields, and reduced stability. Recently, gold clusters have emerged as a promising class of nanomaterials with potential applications in biocatalysis, fluorescence sensing, biological imaging, and more. Water-soluble gold clusters are particularly attractive as fluorescent probes due to their remarkable optical properties, including strong photoluminescence, large Stokes shifts, and excellent photostability. Furthermore, their outstanding biocompatibility—attributed to good aqueous stability, ultra-small hydrodynamic size, and high renal clearance efficiency—makes them especially suitable for biomedical applications. Gold clusters hold significant potential for NIR-II fluorescence imaging. Atomic-precision gold clusters, typically composed of tens to hundreds of gold atoms and measuring only a few nanometers in diameter, possess well-defined three-dimensional structures and clear spatial coordination. This atomic-level precision enables fine-tuned structural regulation, further enhancing their fluorescence properties. Variations in cluster size, surface ligands, and alloying elements can result in distinct physicochemical characteristics. The incorporation of different atoms can modulate the atomic and electronic structures of gold clusters, while diverse ligands can influence surface polarity and steric hindrance. As such, strategies like alloying and ligand engineering are effective in enhancing both fluorescence and catalytic performance, thereby meeting a broader range of clinical needs. In recent years, gold clusters have attracted growing attention in the biomedical field. Their application in NIR-II imaging has led to significant progress in vascular, organ, and tumor imaging. The resulting high-resolution, high signal-to-noise imaging provides powerful tools for clinical diagnostics. Moreover, biologically active gold clusters can aid in drug delivery and disease diagnosis and treatment, offering new opportunities for clinical therapeutics. Despite the notable achievements in fundamental research and clinical translation, further studies are required to address challenges related to the standardized synthesis and complex metabolic behavior of gold clusters. Resolving these issues will help accelerate their clinical adoption and broaden their biomedical applications. 
		                        		
		                        		
		                        		
		                        	
2.Study on the Substance Benchmark Characteristic Chromatogram and Multi-Component Content Determination of Classical Formula Fuzi Decoction
Zhen-Zhen PAN ; Yu-Jie XU ; Jia-Hui LIU ; Hui-Min YE ; Zhen-Hua WANG ; Chang-Qing LI
Journal of Guangzhou University of Traditional Chinese Medicine 2024;41(9):2442-2451
		                        		
		                        			
		                        			Objective To establish a high performance liquid chromatography(HPLC)characteristic chromatogram and multi-component content determination method for the substance benchmark of Fuzi Decoction.Methods The characteristic chromatogram method of Fuzi Decoction substance benchmark was established,and the Similarity Evaluation System of Chromatographic Fingerprint of Traditional Chinese Medicine(2012 Edition)was used to analyze the characteristic chromatograms of 15 batches of Fuzi Decoction substance benchmark samples.The HPLC content determination methods of 1 1 components in the Fuzi Decoction substance benchmark samples were established respectively,and the dry extract rate of 15 batches of Fuzi Decoction substance benchmark samples was determined.Results The similarity of characteristic chromatograms of 15 batches of Fuzi Decoction substance benchmark samples was greater than 0.9,and 12 common peaks were selected and eight of them were identified.The results showed that the contents of benzoylmesaconine,benzoylhypaconine,atractylenolide Ⅲ,ginsenoside Rg1,ginsenoside Re,ginsenoside Rb1,gallic acid,albiflorin,paeoniflorin,1,2,3,4,6-penta-galloyl glucose and benzoyl paeoniflorin were 0.050 3-0.191 1,0.026 7-0.047 0,0.043 0-0.127 6,0.554 6-1.006 8,0.568 7-0.979 5,0.929 9-1.726 1,1.058 9-2.118 4,1.430 3-4.965 5,6.882 9-9.511 1,0.056 1-0.262 5,0.160 6-0.369 0 mg/g,respectively.The average dry extract rate of the 15 batches of Fuzi Decoction substance benchmark samples was 29.54%.Conclusion The established characteristic chromatogram and multi-index content determination method are accurate and stable,which provides a basis for the quality control of the substance benchmark and related preparations of Fuzi Decoction.
		                        		
		                        		
		                        		
		                        	
3.Effects of chest wall compensation film thickness and patient's body characteristics on setup errors and dosimetry in intensity-modulated radiotherapy for breast cancer
Yuping LIU ; Zhen ZHANG ; Yu WANG ; Juanjuan CHANG ; Guangming WANG
Chinese Journal of Medical Physics 2024;41(6):678-682
		                        		
		                        			
		                        			Objective To investigate the effects of the thickness of the chest wall compensation film and the patient's body characteristics on the setup errors and radiation dose of breast cancer patients receiving intensity-modulated radiotherapy following surgery.Methods A total of 103 patients with breast cancer who were treated in the Tumor Radiotherapy Center of Fuyang Cancer Hospital from January 2021 to June 2023 were selected for a prospective study.All patients received cone-beam CT scan.The effects of body mass index(BMI),tumor location,chest circumference,and the affected breast volume on the setup errors were analyzed;and the effects of different compensation film thicknesses on the radiation doses to the planning target volume(PTV),lung,heart,and spinal cord were explored.Results The left-right setup errors didn't differ significantly in breast cancer patients with different BMI and affected sides(P>0.05);but the patients with chest circumference≥89.0 cm and affected breast volume≥650 cm3 had greater left-right setup errors than the other patients(chest circumference<89.0 cm and affected breast volume<650 cm3)(P<0.05).The difference in the superior-inferior setup errors was trivial in breast cancer patients with different affected sides(P>0.05),but the superior-inferior setup errors were greater in patients with BMI≥23.1 kg/m2,chest circumference≥89.0 cm,and breast volume on the affected side≥650 cm3 than the others(BMI<23.1 kg/m2,chest circumference<89.0 cm,and breast volume on the affected side<650 cm3)(P<0.05).There was no significant difference in the anterior-posterior setup errors in breast cancer patients with different BMI,chest circumferences,breast volumes,and affected sides(P>0.05).For left-sided breast cancer,the measured values of D95%and D5%of PTV,V20%of left lung,V30%and Dmean of heart,Dmax of spinal cord,MU,and HI in patients with 0.5 and 1.0 cm compensation films were close(P>0.05);while lower CI was found in patients with 0.5 cm compensation film than those with 1.0 cm compensation film(P<0.05).For right-sided breast cancer,the measured values of D95%and D5%of PTV,V20%of right lung,Dmax of spinal cord,MU,CI,and HI didn't differ significantly between patients using 0.5 and 1.0 cm compensation films(P>0.05).Conclusion The BMI,chest circumference,and breast volume on the affected side in breast cancer patients undergoing intensity-modulated radiotherapy are all associated with the setup errors.Both 0.5 and 1.0 cm chest wall compensation films can be used for postoperative radiotherapy,which has little effect on the dosimetry and accelerator MU.
		                        		
		                        		
		                        		
		                        	
4.Robot-assisted screw fixation for unstable pelvic ring fractures
Zhen ZHANG ; Xueguang WANG ; Shengjun DUAN ; Yanbin SUN ; Bo TANG ; Daofu JIA ; Chang LI ; Houling ZHAO ; Shang LI ; Hongfei LI ; Huashui LIU
Chinese Journal of Orthopaedics 2024;44(7):470-476
		                        		
		                        			
		                        			Objective:To investigate the clinical efficacy of robot-assisted screw fixation for unstable pelvic ring multifocal fractures.Methods:A retrospective analysis was performed on 76 patients with unstable pelvic fractures treated with orthopaedic robot-assisted screw fixation in the Trauma Center of the Affiliated Central Hospital of Shandong First Medical University from January 2015 to June 2022, including 43 males and 33 females, aged 52.53±13.68 years (range, 16-87 years). There were 43 cases of falling injuries from high places, 22 cases of traffic accidents, 11 cases of crushing injuries and heavy objects. Fifty-five patients were employed before the injury, while 21 were not. Fractures were classified according to the Tile classification, with 72 cases classified as type B and 4 cases as type C. Robot-assisted fixation techniques included internal fixator (INFIX), anterior ring screws, sacroiliac screws, and LC-II screws. Intraoperative blood loss, fluoroscopy frequency, surgical time, and the success rate of initial guidewire placement were recorded. Fracture reduction quality was evaluated using the Matta criteria, and postoperative pelvic function recovery was assessed using the Majeed criteria.Results:A total of 150 surgical procedures were performed on 76 patients, including 34 cases of INFIX fixation, 48 cases of anterior ring screws, 61 cases of sacroiliac joint screws, and 7 cases of LC-II screws. The mean intraoperative fluoroscopy frequency was 46.63±17.50 times (range, 15-93 times). Intraoperative fluoroscopy frequency varied among different fixation techniques, with INFIX group at 16.44±4.32 times, LC-II group at 21.59±5.80 times, anterior ring screws group at 29.44±11.65 times, and sacroiliac screws group at 23.10±11.87 times. The intraoperative blood loss was 20 (10, 47.5) ml (range, 5-300 ml), and the surgical time was 105 (86, 150) min (range, 30-290 min). The mean surgical time varied among different fixation techniques. All patients were followed up for an average of 6.46±2.26 months (range, 3-16 months). Clinical healing was achieved in all patients within 6 months, with an average time of 3.14±0.50 months. At the last follow-up, fracture reduction quality assessed by the Matta score was excellent in 21 cases and good in 43 cases, with an excellent/good rate of 84% (64/76). The Majeed score was 81.82±9.14 points (range, 50-92 points). For patients who were employed before the injury, the Majeed score was 86.55±4.85 points (range, 60-92 points), with 49 cases rated as excellent, 5 cases as good, and 1 case as fair. For patients who were not employed before the injury, the Majeed score was 69.43±5.34 points (range, 50-73 points), with 18 cases rated as excellent, 2 cases as good, and 1 case as fair. The overall excellent and good rate was 97% (74/76). Among patients who underwent INFIX internal fixation, 8 cases experienced lateral femoral cutaneous nerve injury postoperatively, all of which recovered sensation after 3 months; 1 case using LC-II screws experienced screw loosening postoperatively and was advised to reduce activity, then the screw was removed after fracture healing at 6 months postoperatively; 1 case using anterior ring channel screws experienced surgical site infection postoperatively, which was controlled after debridement.Conclusion:In the treatment of unstable pelvic ring multiple fractures, robot-assisted screw fixation has less blood loss, less fluoroscopy times, high success rate of planning guide needle, satisfactory reduction quality and postoperative function.
		                        		
		                        		
		                        		
		                        	
5.Pathogenic and molecular characteristics of Klebsiella pneumoniae in fecal samples from diarrhea cases in a district of Beijing in 2018-2021
Shuang ZHANG ; Juan ZHAO ; Chang LIU ; Hai-Rui WANG ; Xi YANG ; Hui-Bo WANG ; Yuan-Yuan WANG ; Hui LI ; Jian-Tao ZHANG ; Zhen-Dong ZHANG ; Nan CHEN ; Ying LI ; Mao-Jun ZHANG ; Rui TIAN
Chinese Journal of Zoonoses 2024;40(8):745-749,757
		                        		
		                        			
		                        			This study was aimed at investigating the pathogenic and molecular characteristics of Klebsiella pneumoniae(KP)in fecal samples of diarrhea cases in a district of Beijing.Fecal samples from diarrhea cases in an outpatient department in a district of Beijing from 2018 to 2021 were collected,and used for isolation and culture of KP.The KP strains isolated strains were subjected to drug resistance phenotype testing and whole-genome sequencing.Multilocus sequence typing and whole-genome phyletic evolution analysis were performed on the sequencing results.The cases'epidemiological and clinical characteristics were analyzed.From 2018 to 2021,1 103 fecal samples were collected and detected.The total detection rate of KP was 10.43%(115/1 103),and the infection rate of KP mixed with other diarrhea-causing pathogens was 42.61%(49/115).The positivity rate was slightly high(12.47%,61/489)a-mong females and was highest in young adults 16-45 years of age.Small peaks were observed in January,April to May,and August to September.The gastrointestinal symptoms in cases were mainly nausea and watery stool,and the suspicious food was unknown.Ampicillin,tetracycline,and sulfafurazole were the top three antibiotics to which these 115 KP strains showed resistance,and 29 strains were resistant to multiple antibiotics.The strains were divided into 72 sequence types,among which ST23 was dominant.According to the phylogenetic tree,the strains were divided into four main branches,among which 14 ST23 strains had a very close genetic relationship with the highly virulent NTUH-K2044 reference strain.KP infection persisted in fecal samples from diarrhea cases in the district of Beijing.Women and young adults were particularly susceptible.The drug resistance of KP strains in this region was very serious,and the ST types were diverse.Moreover,the ST23 pathogenic strains were closely related to high virulence strains.
		                        		
		                        		
		                        		
		                        	
6.Whole-genome sequence analysis of Anhui strain of enzootic nasal tumor virus in goats
Lingxu LI ; Zhen WANG ; Wenqing GUO ; Ziyan LIN ; Guangjun CHANG ; Dawei YAO
Chinese Journal of Veterinary Science 2024;44(11):2341-2347
		                        		
		                        			
		                        			This study aims to obtain two whole-genome sequences of enzootic nasal tumor virus of goats(ENTV-2)from Anhui Province and analyzed the genetic diversity of ENTV-2 gene.Nasal secretion samples and blood samples of six goats with enzootic nasal adenocarcinoma(ENA)were collected from a goat farm in Anhui Province.The total RNA was extracted by the TRIzol method.The DNA interference was removed by the two-step reverse transcription.The ENTV-2 was detec-ted by PCR.Then,two positive samples were selected and five pairs of primers were used to ampli-fy the whole-genome sequences of ENTV-2.After sequencing and splicing,two sequences were up-loaded to the database for comparative analysis with the sequences in the NCBI database.Finally,the genetic evolution tree was constructed.ENTV-2 was detected in the nasal secretion samples,but not in the blood of the six ENA goats.The ENTV-2 genes were approximately 7 400 bp in length,named ENTV-2AH1(DDBJ accession no.:LC762616)and ENTV-2AH2(DDBJ accession no.:LC762617),respectively.Two sequences showed 99.2%and 99.1%homology with the Fujian strain(ENTV-2FJ)and Guangxi strain(ENTV-2-DA0),respectively.They were in the same evo-lutionary branch.In this study,two whole-genome sequences of ENTV-2 were obtained in Anhui for the first time,which can help to further study the genetic diversity of ENTV-2 in China.
		                        		
		                        		
		                        		
		                        	
7.On-line Measurement of Styrene Secondary Organic Aerosol Using Synchrotron Radiation Vacuum Ultraviolet Photoionization Aerosol Mass Spectrometer
Ming-Qiang HUANG ; Xiao-Bin SHAN ; Liu-Si SHENG ; Zhen-Ya WANG ; Chang-Jin HU ; Xue-Jun GU ; Wei-Jun ZHANG
Chinese Journal of Analytical Chemistry 2024;52(8):1200-1210
		                        		
		                        			
		                        			Secondary organic aerosol(SOA)produced by photooxidation of styrene and other aromatic compounds is a major part of fine particles in urban atmosphere.In this study,the measurement of component and content of SOA formed from photooxidation of styrene in smog chamber using synchronous radiation vacuum-ultraviolet photoionization aerosol mass spectrometer(VUV-PIAMS)was conducted.Photoionization mass spectra of styrene SOA was detected by synchrotron radiation photon with 10.5 eV,and the proportion of main components was quantified based on the peak area of each ion peak.The photoionization efficiency curve of ion peak was obtained under synchrotron radiation photons in the range from 7.5 to 11.5 eV,and then the ionization potential was acquired for qualitative analysis of the component structure.The results showed that the photoionization mass spectra of styrene SOA mainly contained ion peaks at m/z 106,108,120 and 122,and the ionization potentials of each peak were(9.41±0.03)eV,(8.93±0.03)eV,(9.24±0.03)eV and(9.25±0.03)eV,respectively.Combined with quantum chemistry calculation and off-line measurement verification of infrared absorption spectra and electrospray ionization mass spectra,it was determined that benzaldehyde,benzyl alcohol,4-vinylphenol and benzoic acid were main components of styrene SOA,accounting for 32.5%,17.5%,25%and 15%of the measured components,respectively,and the generated quantity ratio was 13∶7∶10∶6.VUV-PIAMS could overcome the disadvantages of off-line method,and could on-line detect component and content of SOA,proving a useful tool to measure the chemical components and reveal the formation process of SOA particles.
		                        		
		                        		
		                        		
		                        	
8.Research on Electrochemical Chemical Oxygen Demand Sensor
Shan YUN ; Lei WANG ; Li-Guo WAN ; Zhen-Yu PENG ; Hong-Chang WANG ; Jun-Feng ZHAI ; Shao-Jun DONG
Chinese Journal of Analytical Chemistry 2024;52(9):1298-1306
		                        		
		                        			
		                        			An electrochemical chemical oxygen demand(COD)sensor was proposed based on a FTO/TiO2/PbO2 electrode and a thin-layer electrochemical cell.The FTO/TiO2/PbO2 electrode was characterized by X-ray photoelectronic spectroscopy(XPS),X-ray diffraction(XRD)spectroscopy and electrochemical technique,and the results indicated that the rapid decrease in the output signals of the electrochemical COD sensor could be attributed to oxidation of PbSO4 occurring on the surface of FTO/TiO2/PbO2 electrode.The PbO2 deposition time and concentration of Na2SO4 were further optimized and then the electrochemical COD sensor was challenged by real samples including laker water sample,river water sample and wastewater sample.The evolution trend of signals of the electrochemical COD sensor in response to lake and river water samples was identical with that obtained with the standard method(HJ/T399-2007,Water quality-determination of the chemical oxygen demand-fast digestion-spectrophotometric method).The electrochemical COD sensor exhibited significant increase in the signal intensity after the samples were switched from lake water to wastewater sample,and a mean value of 32.5 mg/L with relative standard deviation(RSD)of 6.8%were obtained after measuring 45 times the wastewater with COD value of 30 mg/L under a sampling interval of 400 s.The as-prepared electrochemical COD sensor possessed good promise in regular monitoring of COD,discharge of wastewater and industrial process control,with advantages such as a small sampling interval,mild reaction conditions and no requirement of toxic and harmful chemical reagents.
		                        		
		                        		
		                        		
		                        	
9.Age Estimation by Machine Learning and CT-Multiplanar Reformation of Cra-nial Sutures in Northern Chinese Han Adults
Xuan WEI ; Yu-Shan CHEN ; Jie DING ; Chang-Xing SONG ; Jun-Jing WANG ; Zhao PENG ; Zhen-Hua DENG ; Xu YI ; Fei FAN
Journal of Forensic Medicine 2024;40(2):128-134,142
		                        		
		                        			
		                        			Objective To establish age estimation models of northern Chinese Han adults using cranial suture images obtained by CT and multiplanar reformation(MPR),and to explore the applicability of cranial suture closure rule in age estimation of northern Chinese Han population.Methods The head CT samples of 132 northern Chinese Han adults aged 29-80 years were retrospectively collected.Volume reconstruction(VR)and MPR were performed on the skull,and 160 cranial suture tomography images were generated for each sample.Then the MPR images of cranial sutures were scored according to the closure grading criteria,and the mean closure grades of sagittal suture,coronal sutures(both left and right)and lambdoid sutures(both left and right)were calculated respectively.Finally taking the above grades as independent variables,the linear regression model and four machine learning models for age estimation(gradient boosting regression,support vector regression,decision tree regression and Bayesian ridge regression)were established for northern Chinese Han adults age estimation.The accu-racy of each model was evaluated.Results Each cranial suture closure grade was positively correlated with age and the correlation of sagittal suture was the highest.All four machine learning models had higher age estimation accuracy than linear regression model.The support vector regression model had the highest accuracy among the machine learning models with a mean absolute error of 9.542 years.Conclusion The combination of skull CT-MPR and machine learning model can be used for age esti-mation in northern Chinese Han adults,but it is still necessary to combine with other adult age estima-tion indicators in forensic practice.
		                        		
		                        		
		                        		
		                        	
10.Clinical trial of Morinda officinalis oligosaccharides in the continuation treatment of adults with mild and moderate depression
Shu-Zhe ZHOU ; Zu-Cheng HAN ; Xiu-Zhen WANG ; Yan-Qing CHEN ; Ya-Ling HU ; Xue-Qin YU ; Bin-Hong WANG ; Guo-Zhen FAN ; Hong SANG ; Ying HAI ; Zhi-Jie JIA ; Zhan-Min WANG ; Yan WEI ; Jian-Guo ZHU ; Xue-Qin SONG ; Zhi-Dong LIU ; Li KUANG ; Hong-Ming WANG ; Feng TIAN ; Yu-Xin LI ; Ling ZHANG ; Hai LIN ; Bin WU ; Chao-Ying WANG ; Chang LIU ; Jia-Fan SUN ; Shao-Xiao YAN ; Jun LIU ; Shou-Fu XIE ; Mao-Sheng FANG ; Wei-Feng MI ; Hong-Yan ZHANG
The Chinese Journal of Clinical Pharmacology 2024;40(6):815-819
		                        		
		                        			
		                        			Objective To observe the efficacy and safety of Morinda officinalis oligosaccharides in the continuation treatment of mild and moderate depression.Methods An open,single-arm,multi-center design was adopted in our study.Adult patients with mild and moderate depression who had received acute treatment of Morinda officinalis oligosaccharides were enrolled and continue to receive Morinda officinalis oligosaccharides capsules for 24 weeks,the dose remained unchanged during continuation treatment.The remission rate,recurrence rate,recurrence time,and the change from baseline to endpoint of Hamilton Depression Scale(HAMD),Hamilton Anxiety Scale(HAMA),Clinical Global Impression-Severity(CGI-S)and Arizona Sexual Experience Scale(ASEX)were evaluated.The incidence of treatment-related adverse events was reported.Results The scores of HAMD-17 at baseline and after treatment were 6.60±1.87 and 5.85±4.18,scores of HAMA were 6.36±3.02 and 4.93±3.09,scores of CGI-S were 1.49±0.56 and 1.29±0.81,scores of ASEX were 15.92±4.72 and 15.57±5.26,with significant difference(P<0.05).After continuation treatment,the remission rate was 54.59%(202 cases/370 cases),and the recurrence rate was 6.49%(24 cases/370 cases),the recurrence time was(64.67±42.47)days.The incidence of treatment-related adverse events was 15.35%(64 cases/417 cases).Conclusion Morinda officinalis oligosaccharides capsules can be effectively used for the continuation treatment of mild and moderate depression,and are well tolerated and safe.
		                        		
		                        		
		                        		
		                        	
            
Result Analysis
Print
Save
E-mail