1.Research progress in data processing methods of neuronal soma calcium imaging
Wenlong XIA ; Zhe ZHAO ; Ming FAN ; Haitao WU
Military Medical Sciences 2024;48(1):68-74
The recording and analysis of activities of calcium signals in neurons is of critical importance in the field of neuroscience.Over the past three decades,various fluorescent calcium imaging techniques not only have been used in the imaging study of functional activities of neuronal communities,but also can be combined with specific markers to record the functional activities of specific types of neuronal communities.To analyze neural activities at the cellular level,a series of preprocessing such as motion correction,cell body recognition,calcium signal extraction and peak deconvolution is required for the collected video.However,current methods for manual preprocessing are time-consuming and laborious,so computer automatic analysis technology is urgently needed to quickly repair the jitter in the video,identify the position and outline of a single cell,extract its activity trajectory and infer the action potential peak.In this paper,the methods of calcium imaging data processing used in recent years are summarized,and the future developments are predicted.
2.HDCGUnet:a neural network for image segmentation of calcium imaging
Wenlong XIA ; Yan WU ; Zhe ZHAO ; Ming FAN ; Haitao WU
Military Medical Sciences 2024;48(2):122-128
Objective To build a neural network based on the Unet infrastructure for recognition and segmentation of two-dimensional calcium imaging fluorescence images.Methods The in vivo miniaturized two-photon microscope(mTPM)was used for brain calcium imaging in freely moving mice.The imaging data was motion corrected using the NoRMCorre algorithm and processed using ImageJ software to obtain the original images after correction,and the labels were produced using the Labelme software.The neural network HDCGUnet was built using the original images and labels for training,and optimized to improve the model structure according to the training effect.Finally,the evaluation indexes were selected and compared with those of other models to verify the utility of this model.Results The HDCGUnet model,which was collected and made on our own,performed best in the two-photon calcium imaging dataset compared to other models,and performed well on the BBBC dataset either.Conclusion The HDCGUnet model provides a novel alternative for the recognition and segmentation of two-photon calcium imaging images.
3.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
4.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
5.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
6.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
7.IL2rg-/- rats support prolonged infection of human RSV
Rui XIONG ; Yong WU ; Yanwei YANG ; Zhe QU ; Susu LIU ; Yuya WANG ; Liying MA ; Rui FU ; Yihong PENG ; Chunnan LIANG ; Changfa FAN
Acta Laboratorium Animalis Scientia Sinica 2024;32(1):17-24
Objective To overcome the limitations of existing human respiratory syncytial virus(hRSV)animal models,such as semi-permissiveness and short duration of infection,this study established an IL2rg gene knockout(IL2rg-/-)rat model using TALEN gene editing technology.Methods The animal model was infected with hRSV intranasally.Clinical characteristics,body weight,and temperature changes were observed over the infection period(0~35 days).The total viral loads in respiratory organs,such as the nasal tissue,trachea,and lungs,were measured at various time points(4,11,20,and 35 days post-infection).Pathological analysis was conducted on target organs at the endpoint of observation(35 days post-infection).Changes in peripheral blood T,B,NK,and NKT cells and various cytokines were assessed at various time points(4,20,and 35 days post-infection).Results(1)IL2rg/-knockout rats sustained high viral loads in the nasal cavity upon intranasal inoculation with hRSV.The average peak titer rapidly reached 1 × 1010 copies/g in nasal tissue and 1 × 107 copies/g up to 5 weeks post-infection.(2)However,no significant pathological changes were noted in nasal,tracheal,or lung tissues.(3)An increase was observed in the content of peripheral blood B cells in hRSV-infected IL2rg--rats.(4)IL-6 and MCP-1 were increased in the early stage of infection and then decreased at the end of the observation period.Conclusions This study established a new IL2rg-/-rat model using TALEN technology and found that this model effectively supported high-level replication and long-term infection of hRSV,providing a good basis for antiviral drug screening and in vivo efficacy evaluation of anti-hRSV antibodies.
8.Clinical guidelines for the treatment of ankylosing spondylitis combined with lower cervical fracture in adults (version 2024)
Qingde WANG ; Yuan HE ; Bohua CHEN ; Tongwei CHU ; Jinpeng DU ; Jian DONG ; Haoyu FENG ; Shunwu FAN ; Shiqing FENG ; Yanzheng GAO ; Zhong GUAN ; Hua GUO ; Yong HAI ; Lijun HE ; Dianming JIANG ; Jianyuan JIANG ; Bin LIN ; Bin LIU ; Baoge LIU ; Chunde LI ; Fang LI ; Feng LI ; Guohua LYU ; Li LI ; Qi LIAO ; Weishi LI ; Xiaoguang LIU ; Hongjian LIU ; Yong LIU ; Zhongjun LIU ; Shibao LU ; Yong QIU ; Limin RONG ; Yong SHEN ; Huiyong SHEN ; Jun SHU ; Yueming SONG ; Tiansheng SUN ; Yan WANG ; Zhe WANG ; Zheng WANG ; Hong XIA ; Guoyong YIN ; Jinglong YAN ; Wen YUAN ; Zhaoming YE ; Jie ZHAO ; Jianguo ZHANG ; Yue ZHU ; Yingjie ZHOU ; Zhongmin ZHANG ; Wei MEI ; Dingjun HAO ; Baorong HE
Chinese Journal of Trauma 2024;40(2):97-106
Ankylosing spondylitis (AS) combined with lower cervical fracture is often categorized into unstable fracture, with a high incidence of neurological injury and a high rate of disability and morbidity. As factors such as shoulder occlusion may affect the accuracy of X-ray imaging diagnosis, it is often easily misdiagnosed at the primary diagnosis. Non-operative treatment has complications such as bone nonunion and the possibility of secondary neurological damage, while the timing, access and choice of surgical treatment are still controversial. Currently, there are no clinical practice guidelines for the treatment of AS combined with lower cervical fracture with or without dislocation. To this end, the Spinal Trauma Group of Orthopedics Branch of Chinese Medical Doctor Association organized experts to formulate Clinical guidelines for the treatment of ankylosing spondylitis combined with lower cervical fracture in adults ( version 2024) in accordance with the principles of evidence-based medicine, scientificity and practicality, in which 11 recommendations were put forward in terms of the diagnosis, imaging evaluation, typing and treatment, etc, to provide guidance for the diagnosis and treatment of AS combined with lower cervical fracture.
9.A novel anchor-loop internal fixation system in coracoclavicular ligament reconstruction for acromioclavicular dislocation: a biomechanical study
Chen WANG ; Na YANG ; Lisong HENG ; Wei FAN ; Yangjun ZHU ; Kun ZHANG ; Zhe SONG
Chinese Journal of Orthopaedic Trauma 2024;26(2):125-129
Objective:To explore the biomechanical stability of a novel anchor-loop internal fixation system in the treatment of acromioclavicular joint dislocation using cadaveric specimens.Methods:The acromioclavicular ligaments were severed in 12 complete shoulder joint specimens, in which the quasi-static non-destructive cycle experiment was performed until the coracoclavicular ligaments failed. The failure intensities of the coracoclavicular ligaments were recorded. Next, the 12 specimens were randomly divided into groups A, B, C and D ( n=3), in which 4 different internal fixation materials were used respectively to reduce and fix the acromioclavicular joint. Group A was subjected to 3.5 mm clavicular hook locking compression plate, group B to 5 mm soft tissue with wire anchor, group C to 10 mm Endobutton steel plate, and group D to the novel anchor-loop internal fixation system (5 mm soft tissue with wire anchor + 10 mm Endobutton steel plate). An X-ray machine was used to evaluate the reduction and internal fixation of the acromioclavicular joint. After the shoulder specimens were securely fastened by a homemade fixation jig to a 100 KN electronic universal mechanical testing machine, each experimental specimen was subjected to a destructive static tensile mechanic determination in the vertical direction at a loading speed of 100 mm/min. The load-displacement curves were recorded and drawn by a computer connected with the biomechanical testing machine. The failure strength and failure causes were recorded for each internal fixation. Results:The fracture strength of the coracoclavicular ligament in 12 cadaver specimens was (374.6±0.8) N. The mechanical load of internal fixation failure was (409.5±2.6) N in group A, (297.8±3.4) N in group B, (375.2±3.1) N in group C and (376.2±3.1) N in group D. The internal fixation failure was due to clavicular fracture in 2 specimens and to acromial fracture in 1 specimen in group A, to anchor protrusion in all the 3 specimens in group B, to coracoid base fracture in all the 3 specimens in group C, and to anchor protrusion in all the 3 specimens in group D. The mechanical loads of internal fixation failure were significantly different among the 4 experimental groups ( P<0.05). The mechanical load of internal fixation failure in group D was significantly different from that in groups A and B ( P<0.05). Conclusions:Our self-developed novel anchor-loop internal fixation system can effectively reposit the acromioclavicular joint to treat acromioclavicular joint dislocation, because it conforms to the biomechanical characteristics of the acromioclavicular joint, and is easy to handle. Therefore, its feasibility is high.
10.Effect of early immunotherapy in preventing conversion of ocular myasthenia gravis to generalized myasthenia gravis
Zhe RUAN ; Fan NING ; Yue SU ; Ting CHANG ; Qiumin QU
Journal of Xi'an Jiaotong University(Medical Sciences) 2024;45(2):312-319
【Objective】 To compare the risk of generalization in patients with ocular myasthenia gravis (OMG) receiving or not receiving immunosuppressive treatment. 【Methods】 The data of patients with OMG registered in Tangdu Hospital of Air Force Military Medical University from January 1, 2015 to May 1, 2019 were reviewed; the patients were divided into treatment group and control group according to whether they had received immunosuppressive treatment. The multivariate Cox proportional hazards regression model analysis was used to compare the risk of generalization between the two groups of patients within 2 years of onset. Sensitivity analysis was used to evaluate the duration of immunosuppressive treatment and the risk of generalization under different immunotherapy regimens. By using stratified analysis, the consistency of the main results across different levels of subgroup factors was evaluated. 【Results】 A total of 702 OMG patients were collected. Of them 367 patients (52.3%) were included in the treatment group, with an average onset age of (50.54±15.1) years, and 159 (43.3%) being female. Another 335 patients (47.7%) were included in the control group, with an average age of (49.1±14.6) years, and 159 ones (47.5%) were female. A total of 28 cases (7.7%) in the treatment group and 106 cases (31.6%) in the control group developed generalization during the observation period. After multivariate-adjusted Cox model analysis, patients who had received immunosuppressive treatment had a significantly lower risk of generalization compared with the control group (HR=0.24; 95% CI: 0.15-0.37; P<0.001). Sensitivity analysis found that the longer the duration of immunosuppression, the lower the risk of generalization (HR=0.88; 95% CI: 0.85-0.91; P<0.001). Stratified analysis showed that immunosuppressive therapy reduced the risk of generalization in different subgroups of patients. 【Conclusion】 Early immunosuppressive treatment can significantly reduce the risk of generalization in patients with OMG.

Result Analysis