1.Effect of chromosome-instability-associated gene GALNT7 on proliferation and apoptosis of HCT116 colon cancer cells
Xiao Fang ; Wei Zhao ; Wenying Yu ; Lingjie Pei ; Wenxuan Qian ; Ya Zhao
Acta Universitatis Medicinalis Anhui 2025;60(1):96-101
Objective :
To investigate the effect of chromosome instability(CIN) associated gene polypeptide N-acetylgalactosaminyltransferase 7(GALNT7) on proliferation and apoptosis of HCT116 colon cancer cells.
Methods :
The HCT116 cell line withGALNT7knockdown was constructed by lentiviral infection. The correlation betweenGALNT7and CIN was verified by chromosome spread assay. The effect ofGALNT7on cell proliferation was detected by live cell counting, and the effect ofGALNT7on cell cycle distribution was detected by flow cytometry and Western blot. Caspase-3 activity and Western blot assays were used to detect the effect ofGALNT7on apoptosis.
Results :
HCT116 cells showed a slower proliferation rate upon knocking down ofGALNT7, and exhibited a more scattered karyotype distribution and a phenotype of increased degree of CIN. Inhibition ofGALNT7in HCT116 cells resulted in cell cycle arrest, upregulation of P21 and downregulation of CDK6 protein levels, as well as increased levels of Caspase-3 activity, cleaved PARP1 and PUMA protein expression, and decreased levels of BCL-2 protein expression.
Conclusion
TheGALNT7gene may promote proliferation and inhibit apoptosis of HCT116 colon cancer cells through the suppression of CIN generation.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Analysis of physical fitness test results for freshmen with different nutritional status at Civil Aviation University of China from 2014 to 2024
SHEN Shunfa, PENG Ziye, CHEN Xuedong, LI Huichao, ZHAO Kun, PEI Zhengcun
Chinese Journal of School Health 2025;46(6):857-862
Objective:
To analyze the status and trends of physical fitness test data among college freshmen with different body mass index (BMI) groups from 2014 to 2024, providing the scientific evidence for monitoring and intervening in college students physical health.
Methods:
A census was conducted on all 67 949 freshmen at Civil Aviation University of China from 2014 to 2024. Physical tests included vital capacity, sit and reach, sit ups, 50 m sprint, standing long jump, pull ups, and 800 m/1 000 m run. Freshmen were divided into underweight, normal weight, overweight and obese groups according to WHO BMI standards. The Kruskal-Wallis H test was used to compare differences in physical fitness indicators across gender and BMI groups, while the Mann-Kendall trend test was employed to detect upward or downward trends in physical indicators over time.
Results:
From 2014 to 2024, statistically significant differences were observed in vital capacity, 50 m sprint, standing long jump, and sit and reach among different BMI groups for both genders (boy: Z =2 396.40, 4 160.33, 4 662.23, 531.85; girl: Z =593.37, 308.86, 499.37, 128.70). Significant differences were also found in 1 000 m run and pull ups for boys, and 800 m run and sit ups for girls across BMI groups (boy: Z =6 574.80, 6 880.48; girl: Z =528.56, 146.18) ( P <0.01). Overall physical test scores showed a declining trend during 2014-2024, particularly pronounced in overweight and obese groups. Male vital capacity in 2014 exceeded national survey data( d =320 mL), with the gap widening to 734 mL by 2019, while the female vital capacity difference increased from 271 mL in 2014 to 576 mL in 2019. Male 1 000 m run times were 23.0 s and 17.5 s faster than national data in 2014 and 2019 respectively, while female 800 m run times were 22.3 s and 21.5 s faster than corresponding national data.
Conclusions
Physical health status among freshmen at this university varies across BMI groups and changes over time. Although overall test scores remain higher than national levels, the declining trend in physical fitness performance requires attention.
8.Comparative study of MS-39, Sirius, and Pentacam in assisting size selection of implantable collamer lens
Jiaqi YUE ; Xindi WANG ; Yimeng FAN ; Zhao LIU ; Cheng PEI
International Eye Science 2025;25(9):1505-1510
AIM: To assess the consistency of the new anterior segment analyzer, MS-39, the Sirius and Pentacam in measuring corneal white-to-white(WTW)and central anterior chamber depth(ACD), and to compare their differences in guiding implantable collamer lens(ICL)size selection.METHODS: Retrospective case study. A total of 210 consecutive patients(420 eyes)who treated at the Ophthalmology Refractive Surgery Center of the First Affiliated Hospital of Xi'an Jiaotong University between September 2019 and September 2020 were enrolled. Three anterior segment analysis systems, MS-39, Sirius, and Pentacam, were utilized to assess the WTW and ACD, with comparative analysis of the results. The sizing of the ICL V4c was simulated using the method recommended by the STAAR company. Data correlation and consistency were evaluated.RESULTS: The WTW measurement results obtained from MS-39, Sirius, and Pentacam were 11.39±0.35, 11.42±0.36, and 11.46±0.35 mm, respectively. Notably, the WTW measurement value from MS-39 was significantly lower than that from Pentacam(P=0.002), while no statistically significant differences were observed between MS-39 and Sirius, or between Sirius and Pentacam(all P>0.05). The WTW measurements from the three devices exhibited a strong positive correlation, with correlation coefficients(r)of 0.942 between MS-39 and Sirius, 0.925 between MS-39 and Pentacam, and 0.882 between Sirius and Pentacam(all P<0.0001). The ACD measurements values from the MS-39, Sirius and Pentacam were 3.28±0.22, 3.28±0.24, and 3.21±0.23 mm, respectively. While, no statistically significant difference was found between MS-39 and Sirius(P>0.05), both measurements were significantly higher than that of Pentacam(both P<0.0001). The ACD measurements also demonstrated a strong positive correlation, with r values of 0.959 between MS-39 and Sirius, 0.947 between MS-39 and Pentacam, and 0.932 between Sirius and Pentacam(all P<0.0001). In terms of ICL size selection based on the measurements from the three devices, the 12.6 mm size was the most frequently selected, while the 13.7 mm size was the least common, the distribution of size selections across the devices was similar.CONCLUSION: MS-39 demonstrated strong positive correlation with both Sirius and Pentacam for WTW and ACD measurements, indicating that the results can be considered clinically interchangeable. Furthermore, the outcomes derived from MS-39 for ICL size selection were closely aligned with those from Sirius and Pentacam, suggesting its clinical feasibility.
9.Analysis of risk factors for diaphragmatic dysfunction after cardiovascular surgery with extracorporeal circulation: A retrospective cohort study
Xupeng YANG ; Yi SHI ; Fengbo PEI ; Simeng ZHANG ; Hao MA ; Zengqiang HAN ; Zhou ZHAO ; Qing GAO ; Xuan WANG ; Guangpu FAN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(08):1140-1145
Objective To clarify the risk factors of diaphragmatic dysfunction (DD) after cardiac surgery with extracorporeal circulation. Methods A retrospective analysis was conducted on the data of patients who underwent cardiac surgery with extracorporeal circulation in the Department of Cardiovascular Surgery of Peking University People's Hospital from January 2023 to March 2024. Patients were divided into two groups according to the results of bedside diaphragm ultrasound: a DD group and a control group. The preoperative, intraoperative, and postoperative indicators of the patients were compared and analyzed, and independent risk factors for DD were screened using multivariate logistic regression analysis. Results A total of 281 patients were included, with 32 patients in the DD group, including 23 males and 9 females, with an average age of (64.0±13.5) years. There were 249 patients in the control group, including 189 males and 60 females, with an average age of (58.0±11.2) years. The body mass index of the DD group was lower than that of the control group [(18.4±1.5) kg/m2 vs. (21.9±1.8) kg/m2, P=0.004], and the prevalence of hypertension, chronic obstructive pulmonary disease, heart failure, and renal insufficiency was higher in the DD group (P<0.05). There was no statistical difference in intraoperative indicators (operation method, extracorporeal circulation time, aortic clamping time, and intraoperative nasopharyngeal temperature) between the two groups (P>0.05). In terms of postoperative aspects, the peak postoperative blood glucose in the DD group was significantly higher than that in the control group (P=0.001), and the proportion of patients requiring continuous renal replacement therapy was significantly higher than that in the control group (P=0.001). The postoperative reintubation rate, tracheotomy rate, mechanical ventilation time, and intensive care unit stay time in the DD group were higher or longer than those in the control group (P<0.05). Multivariate logistic regression analysis showed that low body mass index [OR=0.72, 95%CI (0.41, 0.88), P=0.011], preoperative dialysis [OR=2.51, 95%CI (1.89, 4.14), P=0.027], low left ventricular ejection fraction [OR=0.88, 95%CI (0.71, 0.93), P=0.046], and postoperative hyperglycemia [OR=3.27, 95%CI (2.58, 5.32), P=0.009] were independent risk factors for DD. Conclusion The incidence of DD is relatively high after cardiac surgery, and low body mass index, preoperative renal insufficiency requiring dialysis, low left ventricular ejection fraction, and postoperative hyperglycemia are risk factors for DD.
10.Prevalence trends of elevated blood pressure and its association with nutritional status among primary and secondary school students in Inner Mongolia
Chinese Journal of School Health 2025;46(9):1342-1345
Objective:
To analyze the prevalence trends of different types of elevated blood pressure and their association with nutritional status among primary and secondary school students in Inner Mongolia from 2019 to 2024, providing references for targeted prevention strategies.
Methods:
From September 2019 to 2024, a stratified random cluster sampling method was used to select 12 primary and secondary schools from each league city in Inner Mongolia Autonomous Region. A total of 177 108, 137 758, 190 182, 180 084 , 188 056, 180 351 primary and secondary school students (excluding grades one to three of primary school) were included for physical examination. The correlation between their nutritional status and high blood pressure was analyzed based on the basic situation of 129 821 primary and secondary school students who completed a questionnaire survey at the same time in 2024. Statistical analysis was conducted using a Chi-square test and multiple Logistic regression model.
Results:
From 2019 to 2024, the detection rates of elevated blood pressure were 13.60%, 13.68%, 17.60%, 17.24%, 14.77% and 15.96%, respectively. The rates for isolated systolic hypertension were 4.24%, 5.83%, 7.26%, 7.19%, 6.24% and 6.93%; isolated diastolic hypertension rates were 6.38%, 4.99%, 6.23 %, 6.41%, 5.39% and 5.66%; and combined systolic and diastolic hypertension rates were 2.97%, 2.86%, 4.11%, 3.65%, 3.14 % and 3.36%. Multivariate Logistic regression analysis showed that girls, junior high school, senior high school, overweight, and obesity were positively associated with elevated blood pressure risk ( OR =1.27, 1.25, 1.32, 1.66, 3.07, all P <0.05); conversely, county residence, Mongolian ethnicity, and other ethnicities showed negative associations ( OR =0.90, 0.93, 0.90, all P <0.05).
Conclusions
Overweight and obesity among children and adolescents are closely related to various types of elevated blood pressure. Prevention strategies should prioritize effectively controlling weight issues among children and adolescents, thereby effectively reducing the incidence of elevated blood pressure.


Result Analysis
Print
Save
E-mail