1.Internal tension relieving technique assisted anterior cruciate ligament reconstruction to promote ligamentization of Achilles tendon grafts in small ear pigs in southern Yunnan province
Bohan XIONG ; Guoliang WANG ; Yang YU ; Wenqiang XUE ; Hong YU ; Jinrui LIU ; Zhaohui RUAN ; Yajuan LI ; Haolong LIU ; Kaiyan DONG ; Dan LONG ; Zhao CHEN
Chinese Journal of Tissue Engineering Research 2025;29(4):713-720
BACKGROUND:We have successfully established an animal model of small ear pig in southern Yunnan province with internal tension relieving technique combined with autologous Achilles tendon for anterior cruciate ligament reconstruction,and verified the stability and reliability of the model.However,whether internal tension relieving technique can promote the ligamentalization process of autologous Achilles tendon graft has not been studied. OBJECTIVE:To investigate the differences in the process of ligamentalization between conventional reconstruction and internal reduction reconstruction of the anterior cruciate ligament by gross view,histology and electron microscopy. METHODS:Thirty adult female small ear pigs in southern Yunnan province were selected.Anterior cruciate ligament reconstruction was performed on the left knee joint with the ipsilateral knee Achilles tendon(n=30 in the normal group),and anterior cruciate ligament reconstruction was performed on the right knee joint with the ipsilateral knee Achilles tendon combined with the internal relaxation and enhancement system(n=30 in the relaxation group).The autogenous right forelimb was used as the control group;the anterior cruciate ligament was exposed but not severed or surgically treated.At 12,24,and 48 weeks after surgery,10 animals were sacrificed,respectively.The left and right knee joint specimens were taken for gross morphological observation to evaluate the graft morphology.MAS score was used to evaluate the excellent and good rate of the ligament at each time point.Hematoxylin-eosin staining was used to evaluate the degree of ligament graft vascularization.Collagen fibers and nuclear morphology were observed,and nuclear morphology was scored.Ultrastructural remodeling was evaluated by scanning electron microscopy and transmission electron microscopy. RESULTS AND CONCLUSION:(1)The ligament healing shape of the relaxation group was better at various time points after surgery,and the excellent and good rate of MAS score was higher(P<0.05).Moreover,the relaxation group could obtain higher ligament vascularization score(P<0.05).(2)The arrangement of collagen bundles and fiber bundles in the two groups gradually tended to be orderly,and the transverse fiber connections between collagen gradually increased and thickened,suggesting that the strength and shape degree of the grafts were gradually improved,but the ligament remodeling in the relaxation group was always faster than that in the normal group at various time points after surgery.(3)The diameter,distribution density,and arrangement degree of collagen fibers in the relaxation group were better than those in the normal group at all time points,especially in the comparison of collagen fiber diameter between and within the relaxation group(P<0.05).
2.Overview of Chinese Pharmacopoeia 2025 Edition Volume Ⅲ
CAO Yan ; ZHAO Xiong ; WANG Xiaojuan ; CHEN Huiyi ; LI Huiyi
Drug Standards of China 2025;26(1):028-033
“Chinese Pharmacopoeia” is the legal basis for drug development, production, operation, use and management in China, and the Chinese Pharmacopoeia 2025 Edition is going to be issued and implemented. This article introduces the revision and amendment situations, analyzes the characteristics of the new edition of the Pharmacopoeia and the future development direction of national standards for better understanding and implementation of the latest edition of pharmacopoeia.
3.Application of "balance-shaped sternal elevation device" in the subxiphoid uniportal video-assisted thoracoscopic surgery for anterior mediastinal masses resection
Jinlan ZHAO ; Weiyang CHEN ; Chunmei HE ; Yu XIONG ; Lei WANG ; Jie LI ; Lin LIN ; Yushang YANG ; Lin MA ; Longqi CHEN ; Dong TIAN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(03):308-312
Objective To introduce an innovative technique, the "balance-shaped sternal elevation device" and its application in the subxiphoid uniportal video-assisted thoracoscopic surgery (VATS) for anterior mediastinal masses resection. Methods Patients who underwent single-port thoracoscopic assisted anterior mediastinal tumor resection through the xiphoid process at the Department of Thoracic Surgery, West China Hospital, Sichuan University from May to June 2024 were included, and their clinical data were analyzed. Results A total of 7 patients were included, with 3 males and 4 females, aged 28-72 years. The diameter of the tumor was 1.9-17.0 cm. The operation time was 62-308 min, intraoperative blood loss was 5-100 mL, postoperative chest drainage tube retention time was 0-9 days, pain score on the 7th day after surgery was 0-2 points, and postoperative hospital stay was 3-12 days. All patients underwent successful and complete resection of the masses and thymus, with favorable postoperative recovery. Conclusion The "balance-shaped sternal elevation device" effectively expands the retrosternal space, providing surgeons with satisfactory surgical views and operating space. This technique significantly enhances the efficacy and safety of minimally invasive surgery for anterior mediastinal masses, reduces trauma and postoperative pain, and accelerates patient recovery, demonstrating important clinical significance and application value.
4.Association between Mediterranean diet scores and dental caries among children and adolescents with neurodevelopmental disorders
XIONG Wenjuan, SU Yuanyuan, LIU Zhao, HUANG Xiaoqing, QU Zhiyi, CUI Shanshan
Chinese Journal of School Health 2025;46(2):172-176
Objective:
To explore the association between mediterranean diet (MD) patterns and dental caries among children and adolescents with neurodevelopmental disorders (NDD), so as to provide a basis for developing scientific anti caries strategies related to diet.
Methods:
From December 2021 to June 2024, a questionnaire survey, a three day 24 hour dietary review survey, oral health examination, physical development measurement and Childhood Autism Rating Scale (CARS) evaluation were conducted involving 147 children and adolescents aged 2-22 years with NDD from nine special education schools and rehabilitation institutions in Tianjin. Group comparisons were carried out using the Mann-Whitney U test, Chi-square test, or Fisher s exact probability method. The correlation between dietary quality and dental caries was analyzed by adopting multiple linear regression analysis and restricted cubic spline.
Results:
There were 46 children and adolescents (31.3%) in the non dental caries group and 101 children and adolescents (68.7%) in the dental caries group. The number of decayed missing and filled teeth (dmft) was 2.0 (4.0), and the MD score was 4.0 (2.0) points. There were 62 children and adolescents (42.2%) in the low MD scores group and 85 children and adolescents (57.8%) in the high MD scores group. There was no significant difference in MD scores between NDD children in the non dental caries group and those in the dental caries group [nondental caries group:4.0(2.0), dental caries group:4.0(2.0), Z= -0.14, P >0.05]. The MD scores and dmft exhibited increasing and then decreasing trend ( P total =0.02, P non lineary = 0.04 ). Children and adolescents with NDD in the MD high scores group had a lower number of dmft than those in the MD low scores group ( β= -2.00 , 95%CI =-3.39 to -0.62, P <0.05). However, in children and adolescents with NDD and CARS scores ≥30, the above association was insignificant ( β=-0.63, 95%CI=-0.29-0.15, P >0.05).
Conclusion
Children and adolescents with NDD who have dietary patterns similar to the Mediterranean diet, are found to have fewer dental caries, and this is observed among those with no or mild symptoms of autism spectrum disorder.
5.Impact of shift work and obesity on risk of hyperuricemia in coal miners: A cross-sectional design based dose-response relationships and interaction analysis
Zeyuan ZHANG ; Yingjun CHEN ; Yingtong CHEN ; Mengtian XIONG ; Zichao PANG ; Gaisheng LIU ; Hongxia ZHAO ; Liuquan JIANG ; Qingsong CHEN
Journal of Environmental and Occupational Medicine 2025;42(4):451-458
Background The prevalence of hyperuricemia (HUA) among Chinese residents has been increasing annually, with occupational populations facing a higher risk of HUA due to shift work or obesity. Objective To investigate the impact of shift work and obesity on HUA among coal miners, and to provide scientific data for the prevention of HUA in this occupational group. Methods A cross-sectional study was conducted with
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
9.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
10.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.


Result Analysis
Print
Save
E-mail