1.Finite element analysis of various root shield thicknesses in maxillary central incisor socket-shield technique
Guangneng CHEN ; Siyang LUO ; Mei WANG ; Bin YE ; Jiawen CHEN ; Yin LIU ; Yuwen ZUO ; Xianyu HE ; Jiajin SHEN ; Minxian MA
Chinese Journal of Tissue Engineering Research 2025;29(10):2052-2060
BACKGROUND:Socket-shield technique can effectively maintain labial soft and hard tissues,but the incidence of postoperative complications such as exposure and displacement of root shield is relatively high.It is speculated that the root shield may be exposed and displaced due to excessive load after long-term function of dental implants. OBJECTIVE:Through three-dimensional finite element analysis,we aim to study the influence of varying root shield thicknesses on the stress distribution,equivalent stress peaks,and displacement in the root shield,periodontal ligaments,implant,and surrounding alveolar bone under normal occlusal loading.We also attempt to analyze the correlation between the thickness of the root shield and occurrence of mechanical events such as root shield exposure,displacement,and fracture. METHODS:Cone-beam CT data of a patient who met the indication standard of socket-shield technique for maxillary central incisor were retrieved from database.Reverse engineering techniques were used to build models of the maxillary bone and root shield,while forward engineering was used to create models for the implant components based on their parameters.Models depicting various root shield thicknesses(0.5,1.0,1.5,and 2.0 mm)were created using Solidworks 2022 software.ANSYS Workbench 2021 software was then used to simulate and analyze the effects of varying root shield thicknesses on stress distribution,equivalent stress peaks,and displacement of the root shields,periodontal ligaments,implants,and surrounding alveolar bone under normal occlusion. RESULTS AND CONCLUSION:(1)In all root shield models,the stress was concentrated on the palatal cervical side,both sides of the edges and the lower edge of the labial side.As the thickness of the root shield increased,the equivalent stress peak and displacement showed a decreasing trend.The 0.5 mm thickness model produced a stress concentration of 176.20 MPa,which exceeded the yield strength(150 MPa)of tooth tissue.(2)The periodontal ligament stress in each group was concentrated in the neck margin and upper region.With the increase of root shield thickness,the equivalent stress peak and displacement of periodontal ligament showed a decreasing trend.(3)Implant stress in all models was concentrated in the neck of the implant and the joint of the implant-repair abutment,and the labial side was more concentrated than the palatal side.With the increase of root shield thickness,the equivalent stress peak of the implant in the model showed an increasing trend.(4)In each group of models,stress of cortical bone concentrated around the neck of the implant and the periphery of the root shield,and the labial side was more concentrated than the palatal side.With the increase of the thickness of the root shield,the equivalent stress peak around the root shield decreased;the peak value of the equivalent stress of the bone around the neck of the implant showed an increasing trend.In the model,the stress of cancellous bone was mainly concentrated around the neck of the lip of the implant,the top of the thread,the root tip and the lower margin of the root shield,and the labial side was more concentrated than the palatal side.With the increase of the thickness of the root shield,the peak value of the equivalent stress of the bone around the root shield in the model showed a decreasing trend.The minimum principal stress of cortical bone in each group of models was concentrated around the neck of the implant,exhibiting a fan-shaped distribution.As the thickness of the root shield increased,the minimum principal stress of cortical bone showed an increasing trend.(5)These results indicate that different thicknesses of the root shield have different biomechanical effects.The root shield with a thickness of 0.5 mm is easy to fracture.For patients with sufficient bone width,the root shield with a thickness of 2.0 mm is an option to reduce the risk of complications such as root shield exposure,fracture,and displacement.Meanwhile,it should be taken into account to protect the periodontal ligament in the preparation process,and rounding treatments ought to be carried out on both sides and the lower edge of the root shield.
2.A novel anti-ischemic stroke candidate drug AAPB with dual effects of neuroprotection and cerebral blood flow improvement.
Jianbing WU ; Duorui JI ; Weijie JIAO ; Jian JIA ; Jiayi ZHU ; Taijun HANG ; Xijing CHEN ; Yang DING ; Yuwen XU ; Xinglong CHANG ; Liang LI ; Qiu LIU ; Yumei CAO ; Yan ZHONG ; Xia SUN ; Qingming GUO ; Tuanjie WANG ; Zhenzhong WANG ; Ya LING ; Wei XIAO ; Zhangjian HUANG ; Yihua ZHANG
Acta Pharmaceutica Sinica B 2025;15(2):1070-1083
Ischemic stroke (IS) is a globally life-threatening disease. Presently, few therapeutic medicines are available for treating IS, and rt-PA is the only drug approved by the US Food and Drug Administration (FDA) in the US. In fact, many agents showing excellent neuroprotection but no blood flow-improving activity in animals have not achieved ideal clinical efficacy, while thrombolytic drugs only improving blood flow without neuroprotection have limited their wider application. To address these challenges and meet the huge unmet clinical need, we have designed and identified a novel compound AAPB with dual effects of neuroprotection and cerebral blood flow improvement. AAPB significantly reduced cerebral infarction and neural function deficit in tMCAO rats, pMCAO rats, and IS rhesus monkeys, as well as displayed exceptional safety profiles and excellent pharmacokinetic properties in rats and dogs. AAPB has now entered phase I of clinical trials fighting IS in China.
3.Value of CT Quantitative Parameters in Prediction of Pathological Types of Lung Ground Glass Nodules
SHI YIQIU ; SHEN YUWEN ; CHEN JIE ; YAN WANYING ; LIU KEFU
Chinese Journal of Lung Cancer 2024;27(2):118-125
Background and objective The pathological types of lung ground glass nodules(GGNs)show great significance to the clinical treatment.This study was aimed to predict pathological types of GGNs based on computed tomog-raphy(CT)quantitative parameters.Methods 389 GGNs confirmed by postoperative pathology were selected,including 138 cases of precursor glandular lesions[atypical adenomatous hyperplasia(AAH)and adenocarcinoma in situ(AIS)],109 cases of microinvasive adenocarcinoma(MIA)and 142 cases of invasive adenocarcinoma(IAC).The morphological characteristics of nodules were evaluated subjectively by radiologist,as well as artificial intelligence(AI).Results In the subjective CT signs,the maximum diameter of nodule and the frequency of spiculation,lobulation and pleural traction increased from AAH+AIS,MIA to IAC.In the AI quantitative parameters,parameters related to size and CT value,proportion of solid component,energy and entropy increased from AAH+AIS,MIA to IAC.There was no significant difference between AI quantitative parameters and the subjective CT signs for distinguishing the pathological types of GGNs.Conclusion AI quantitative parameters were valu-able in distinguishing the pathological types of GGNs.
4.Three cases of occupational chronic chloropropene poisoning
Yuwen CHEN ; Xin ZHOU ; Jie LIU ; Chunyan MIN ; Yulin KONG
Chinese Journal of Industrial Hygiene and Occupational Diseases 2024;42(8):602-604
Chronic chloropropene poisoning is a disease mainly caused by peripheral nerve damage due to close contact with chloropropene in industrial production, its clinical manifestations include varying degrees of sensory, motor, or tendon reflex disorders in the distal limbs, and neuromyography can show neurogenic damage. This article analyzed and summarized the clinical characteristics, diagnosis and treatment methods of three patients with occupational chronic chloropropene poisoning, in order to enhance the clinical understanding of occupational chronic chloropropene poisoning and provide reference for clinical diagnosis and treatment.
5.Three cases of occupational chronic chloropropene poisoning
Yuwen CHEN ; Xin ZHOU ; Jie LIU ; Chunyan MIN ; Yulin KONG
Chinese Journal of Industrial Hygiene and Occupational Diseases 2024;42(8):602-604
Chronic chloropropene poisoning is a disease mainly caused by peripheral nerve damage due to close contact with chloropropene in industrial production, its clinical manifestations include varying degrees of sensory, motor, or tendon reflex disorders in the distal limbs, and neuromyography can show neurogenic damage. This article analyzed and summarized the clinical characteristics, diagnosis and treatment methods of three patients with occupational chronic chloropropene poisoning, in order to enhance the clinical understanding of occupational chronic chloropropene poisoning and provide reference for clinical diagnosis and treatment.
6.Molecular characteristics of Japanese encephalitis virus carried by Culex tritaeniorhynchus in Dongchuan District, Kunming City, Yunnan Province
Yangyang GU ; Yuwen HE ; Yiju CHEN ; Zhenxing YANG ; Nan LI ; Shunyan LÜ ; Yantao ZHU ; Fangchao RUAN ; Jiali WANG ; Jinglin WANG
Chinese Journal of Schistosomiasis Control 2024;36(4):361-369
Objective To isolate the Japanese encephalitis virus carried by Culex tritaeniorhynchus in Dongchuan District of Yunnan Province and analyze its molecular characteristics, so as to provide insights into the prevention and control of Japanese encephalitis in Yunnan Province. Methods Mosquito specimens were collected using mosquito-trapping lamps from pig farms in Batang Village and Xiaoxin Village, Dongchuan District, Kunming City, Yunnan Province in July 2016, and the mosquito species was identified according to the mosquito morphology. Then, 60 to 100 mosquitoes of each species served as a group and were ground. Baby hamster kidney-21 (BHK-21) cells and Aedes albopictus clone C6/36 cells were used for virus isolation, and positive isolates were identified using flavivirus primers. The positive isolates were amplified using reverse transcription polymerase chain reaction (RT-PCR) assay with 15 pairs of specific primers covering the full length of the genotype I Japanese encephalitis virus, and DNA sequence assembly was performed using the software SeqMan in the DNASTAR package. The obtained sequences were aligned with the complete sequences of 38 Japanese encephalitis virus downloaded from the GenBank with the software MegAlign, and the nucleotide and amino acid homology analyses of the obtained sequences were performed. The difference in amino acid sites was analyzed with the software GeneDoc, and phylogenetic trees were created based on the sequences of the coding region and E protein of the isolated Japanese encephalitis virus with the software Mega X. In addition, the secondary and tertiary structures of the E protein of the Japanese encephalitis virus were predicted using the online tool SOPMA and the software Swiss-Model. Results A total of 5 820 mosquitoes were collected and 3 843 Cx. tritaeniorhynchus (66.03%) were identified according to the mosquito morphology. A positive virus isolate, termed YNDC55-33, was isolated from Cx. tritaeniorhynchoides following batches of virus isolation from mosquito specimens, and cytopathic effect was observed following inoculation into BHK-21 and C6/36 cells. The YNDC55-33 virus isolate was successfully amplified with the flavivirus primes, and a long sequence containing 300 nucleotides was obtained. Following sequence alignment using the BLAST tool, the sequence of the YNDC55-33 virus isolate had high homology with that of the genotype I Japanese encephalitis virus. A long sequence with 10 845 nucleotides in length, which encoded 3 432 amino acids, was obtained by splicing the full sequence of the YNDC55-33 virus isolate. Phylogenetic analysis based on the whole-genome sequence and E gene sequence of the YNDC55-33 virus isolate showed that the new YNDC55-33 virus isolate was most closely related to the genotype I Guizhou isolate (GenBank accession number: HM366552), with nucleotide homology of 98.5% and amino acid homology of 99.4%, and the YNDC55-33 virus isolate shared 97.96% ± 0.33% nucleotide homology and 99.35% ± 0.08% amino acid homology with other genotype I Japanese encephalitis virus isolates, and < 90% nucleotide homology and < 98% amino acid homology with other genotypes of Japanese encephalitis virus. The YNDC55-33 virus isolate and the live attenuated virus vaccine candidate SA14-14-2 isolate differed at 16 amino acid sites on E gene, and 7 out of 8 key amino acid sites related to neurovirulence. The secondary and tertiary structures of the E protein of the YNDC55-33 virus isolate were predicted to be characterized by random coils. Conclusions A genotype I Japanese encephalitis virus was isolated from Cx. tritaeniorhynchus in Dongchuan District, Kunming City. This virus isolate and the live attenuated virus vaccine candidate SA14-14-2 isolate does not differ at antigenic epitopes-related key amino acid sites, and the major protein structure of the virus isolate is random coils. This study adds new data for the epidemiological distribution of Japanese encephalitis virus in Yunnan Province, which may provide insights into the prevention and control of Japanese encephalitis in the province.
7.Study on the influencing factors of unplanned extubation of PICC in 7 298 patients with hematological diseases
Junxia WANG ; Huimin ZHANG ; Miaomiao YANG ; Mengchuan WANG ; Yuwen CHEN ; Li XU
Chongqing Medicine 2024;53(2):239-245
Objective To analyze the influencing factors of unplanned extubation(UE)occurrence of peripherally inserted central catheter(PICC)in the patients with hematological diseases.Methods A retro-spective cohort study method was adopted.The data of 7 298 patients with hematological diseases implanted with PICC catheter and followed up to its removal from January 1,2016 to December 31,2020 in the Hematol-ogy Hospital of Chinese Academy of Medical Sciences were collected,including the demographic information,catheterization records,maintenance and extubation records.According to whether UE occurring,they were divided into the UE group(n=262)and normal extubation group(n=7 036).The general data were com-pared between the two groups.The COX regression was used to analyze the influencing factors of UE in pa-tients with hematological diseases.The dose-effect relationship between age and PICC UE occurrence risk was studied by the restrictive cubic spline method.Results The incidence rate of UE was 3.6%(262/7 298).The COX regression analysis results showed that the gender,disease diagnosis,fibrinogen,prothrombin time,PLT,catheter material,number of punctures during catheterization,positioning method of catheter tip,num-ber of catheter-related complications occurrence were related to PICC UE occurrence in the patients with he-matological diseases(P<0.05).The results of restricted cubic spline showed that there was a"U"-type non-linear relationship between age and UE risk(X2=17.710,P<0.05),and the risk of UE was the lowest when the age was 30 years old.Conclusion In PICC,the emphasis should be paid to the male patients with hemato-logical malignancies who have repeated punctures during catheterization,no intracardiac electrocardiographic positioning during catheterization,bleeding tendency,indwelling polyurethane catheters and repeated catheter-related complications in order to decrease the UC occurrence probability.
8.Construction and Evaluation of A Theoretical Model for the Generation of Urine Testing Instruments
Zhifang LU ; Dacheng LIU ; Xianjie MENG ; Yakang JIN ; Yuwen CHEN
Journal of Modern Laboratory Medicine 2024;39(2):175-180
With the progress of information technology and intelligent technology,the intelligent development of urine testing instruments is facing new opportunities.Using the disease cybernetics theory model to analyze the business process and current urine testing instruments of clinical urine analyzer,a generational theoretical model of urine testing instruments has been constructed,which is conducive to guiding the intelligent development direction of urine testing instruments.The study divides urine testing instruments into one to four generations of products,with the first-generation of products being operated by doctors.The second-generation products are currently available for laboratory technicians to use various urine analyzers.The third-generation products further optimize the testing process and intelligence,without the need for inspectors to operate.The fourth-generation products are unmanned and do not require sampling.It can be seen that with the development of technology,urine analysis has indeed become more convenient,but after all,various instruments have their limitations.Therefore,the establishment of a theoretical model for the generation of urine testing instruments should be applied in clinical urine testing,which can not only improve the efficiency of urine analysis but also improve its quality.
9.Care of a child with human herpesvirus-6B encephalitis after chimeric antigen receptor T-cell therapy
Yi YANG ; Junxia WANG ; Yuwen CHEN ; Huimin ZHANG ; Mengchuan WANG
Chinese Journal of Practical Nursing 2024;40(9):687-692
Summarizing the nursing experience of a child with HHV-6B encephalitis after umbilical cord blood transplantation and CAR-T therapy. The child was 4 years old and was diagnosed with acute T lymphocytic leukemia on May 28, 2021. Nursing points: meticulously observe symptoms for early diagnosis and treatment; develop a specialized management plan, implement individualized care; enhance medication management to improve the quality of care; establish a shared decision-making communication model to prevent hospital-acquired infections; provide patient-centered care for lumbar puncture; assess the needs of the child and family, alleviate negative emotions; improve pre-discharge preparation, emphasize continuity of care. With proactive treatment and careful nursing, the child′s condition improved, and they were discharged. Follow-up for six months showed the child in a sustained remission state with no adverse sequelae, and normal life resumed.
10.Research progresses of deep learning in shoulder joint imaging
Yuwen ZHENG ; Yuhua WU ; Xiaofei CHEN ; Fuwen DONG ; Ping WANG ; Sheng ZHOU
Chinese Journal of Medical Imaging Technology 2024;40(2):302-305
Shoulder pain ranks the third in musculoskeletal pain,with relatively high incidence in the population.Early diagnosis of shoulder diseases is crucial.Deep learning(DL)in shoulder joint imaging was conducive to clinical diagnosis,treatment and prognosis evaluation of shoulder diseases.The research progresses of DL in shoulder joint imaging were reviewed in this article.

Result Analysis
Print
Save
E-mail