1.Preparation of HA-modified emodin-contained multi-walled carbon nanotubes drug delivery system and its inhi-bitory effect on breast cancer cells
Yuduo LI ; Juan DU ; Yunlong LIU ; Feng GENG ; Xiaobing CHEN
China Pharmacy 2025;36(12):1463-1469
OBJECTIVE To prepare hyaluronic acid (HA)-modified emodin (EMD)-contained multi-walled carbon nanotubes (MWCNTs) drug delivery system (HA-MWCNTs-EMD) and explore its in vitro inhibitory effect on breast cancer cells. METHODS EMD was loaded onto MWCNTs to prepare a drug delivery system MWCNTs-EMD; subsequently, the system was further modified with HA to obtain the drug delivery system HA-MWCNTs-EMD. The two drug delivery systems mentioned above were characterized. With free EMD as the reference, the drug release in vitro of the above two drug delivery systems was investigated; the uptake of EMD by two breast cancer cells (MCF-7, MDA-MB-231 cells) was detected. The impacts of the above two drug delivery systems on the expression of surface glycoprotein differentiation group 44 (CD44), activity, apoptosis and lactate dehydrogenase (LDH) release of two breast cancer cells were detected. RESULTS The encapsulation efficiencies of MWCNTs-EMD and HA-MWCNTs-EMD were both (63.52±2.74)%, with drug loading rates of (25.01±1.83)% and (12.13± 1.96)%, particle sizes of (865.95±2.16) and (351.86±1.68) nm, polydispersity indexes of 0.54±0.02 and 0.23±0.01, and Zeta potentials of (23.87±0.14) and (-42.79±0.39) mV, respectively. The 2, 4, 6, 8, 10, 12 and 24-hour cumulative release rates of EMD in MWCNTs-EMD and HA-MWCNTs-EMD were significantly lower than those in free EMD, while the cumulative release rate of HA-MWCNTs-EMD was significantly higher than that of MWCNTs-EMD (P<0.05); the EMD uptakes of MWCNTs-EMD and HA-MWCNTs-EMD by the two types of breast cancer cells were significantly higher than their uptake of free EMD (P<0.05). Compared with the free EMD group, the MWCNTs-EMD and MWCNTs-EMD groups showed significantly higher apoptosis rate and LDH release, significantly lower surface CD44 expression (except for the MWCNTs-EMD group) and cell viability in both cell types, and the effect of HA-MWCNTs-EMD was more pronounced (P<0.05). CONCLUSIONS A novel drug delivery system HA-MWCNTs- EMD loaded with EMD is developed successfully; the drug delivery system has a certain slow-release effect, which can significantly reduce the activity of breast cancer cells, promote their apoptosis and increase the release of LDH, and the above anti- breast cancer effect is significantly stronger than that of free EMD and MWCNTs-EMD.
2.Research progress on mesenchymal stem cell products and their exosomes in the treatment of inflammatory bowel disease
Jingwen YANG ; Qian CHEN ; Yunlong SHAN ; Jiali LIU ; Ning WEI ; Jing WANG ; Guangji WANG ; Fang ZHOU
Journal of China Pharmaceutical University 2024;55(1):103-114
Abstract: Inflammatory bowel disease (IBD), whose pathogenesis remains elusive, is a group of autoimmune diseases characterized by chronic, progressive, and lifelong inflammation of the digestive tract. The pathogenesis of IBD remains elusive. Although a number of drugs have been developed to treat IBD, their effects are merely anti-inflammatory. In addition, current treatments for IBD are easily susceptible to resistance in clinical practice. Mesenchymal stem cells (MSCs) have been reported to have the ability to migrate to the site of inflammation, with potent immunoregulatory effects, and to rebalance the immune microenvironment and restore the integrity of the epithelial barrier with significant value of application, particularly for patients who are refractory to classic medicines. In this paper, we reviewed the clinical applications, mechanisms and engineerable properties of MSC products and their exosomes to provide some reference for the use of MSCs and their exosomes in the treatment of IBD.
3.Progress of single-cell protein imaging methods
Chunlu YAO ; Weijie ZHANG ; Yunlong ZHANG ; Zhaoxia DENG ; Mengling WANG ; Zuoling ZHANG ; Chen WANG ; Qinxin SONG ; Bingjie ZOU
Journal of China Pharmaceutical University 2024;55(2):147-157
Abstract: The differential expression and subcellular localization of single-cell proteins are closely related to the physiological state and pathological mechanisms of the body. The development of single-cell protein in situ imaging methods provides powerful tools for spatial single-cell proteomics research and single-cell protein profiling. This article summarizes the single-cell protein imaging methods developed in recent years, including the circulating immunofluorescence imaging methods based on ordered multi-round antibody incubation, mass spectrometry imaging based on metal element labeled antibodies, fluorescence imaging based on DNA-barcoded antibody, gene encoded fluorescence protein imaging and spectral imaging based on Raman spectroscopy or X-ray spectroscopy, with brief explanation of the imaging principles of these methods. It focuses on the multiple performance, imaging resolution and signal amplification performance of these methods, and analyzes their application characteristics in practical scientific research and clinical work, in the hope of providing some reference for the development of more revolutionary single-cell imaging methods, and promoting the development of biomedical and precision medicine.
4.Construction of risk prediction model for predicting death or readmission in acute heart failure patients during vulnerable phase based on machine learning
Jing ZENG ; Xiaolong HE ; Huajuan HU ; Xiaoyu LUO ; Zhinian GUO ; Yunlong CHEN ; Min WANG ; Jiang WANG
Journal of Army Medical University 2024;46(7):738-745
Objective To construct risk prediction models of death or readmission in patients with acute heart failure(AHF)during the vulnerable phase based on machine learning algorithms and screen the optimal model.Methods A total of 651 AHF patients with admitted to Department of Cardiology of the Second Affiliated Hospital of Army Medical University from October 2019 to July 2021 were included.The clinical data consisting of admission vital signs,comorbidities and laboratory results were collected from electronic medical records.The composite endpoint was defined as all-cause death or readmission for worsening heart failure within 3 months after discharge.The patients were divided into a training set(521 patients)and a test set(130 patients)in a ratio of 8:2 through the simple random sampling.Six machine learning models were developed,including logistic regression(LR),random forest(RF),decision tree(DT),light gradient boosting machine(LGBM),extreme gradient boosting(XGBoost)and neural networks(NN).Receiver operating characteristic(ROC)curve and decision curve analysis(DCA)were used to evaluate the predictive performance and clinical benefit of the models.Shapley additive explanation(SHAP)was used to explain and evaluate the effect of different clinical characteristics on the models.Results A total of 651 AHF patients were included,of whom 203 patients(31.2%)died or were readmitted during the vulnerable phase.ROC curve analysis showed that the AUC values of the LR,RF,DT,LGBM,XGBoost and NN model were 0.707,0.756,0.616,0.677,0.768 and 0.681,respectively.The XGBoost model had the highest AUC value.DCA showed that the XGBoost model exhibited greater clinical net benefit compared with other models,with the best predictive performance.SHAP algorithm analysis showed that the clinical features that had the greatest impact on the output of the model were serum uric acid,D-dimer,mean arterial pressure,B-type natriuretic peptide,left atrial diameter,body mass index,and New York Heart Association(NYHA)classification.Conclusion The XGBoost model has the best predictive performance in predicting the risk of death or readmission of AHF patients during the vulnerable phase.
5.Detection value of double inversion recovery sequence in cerebral white matter hyperintensities in patients with acute ischemic stroke
Jiaqi CHEN ; Yunlong YUE ; Rui FU ; Rui NIU
Chinese Journal of Neuromedicine 2024;23(2):140-145
Objective:To evaluate the detective effect of double inversion recovery (DIR) sequence on cerebral white matter hyperintensities (WMH) in patients with acute ischemic stroke, and compare with those of T2WI and FLAIR sequences.Methods:Seventy-three acute ischemic stroke patients with WMH within 14 d of onset, admitted to Department of Neurology, Beijing Shijitan Hospital, Capital Medical University from November 2018 to March 2021, were chosen. MRI T2WI, FLAIR and DIR sequences were used to detect WMH. According to Fazekas scale, patients with periventricular white matter hyperintensities (PVWMH) or deep white matter hyperintensities (DWMH) were divided into mild group (score of 0-1) and moderate to severe group (scores≥2); the differences in WMH volume detected by T2WI, FLAIR and DIR sequences, and signal intensity, cross-sectional area and contrast of isolated lesions were compared.Results:(1) Seventy-three patients were with PVWMH (36 into the mild group and 37 into the moderate to severe group); in patients from the moderate to severe group, PVWMH volume detected by FLAIR sequence was statistically larger compared with that by DIR sequence, and PVWMH volume detected by T2WI sequence was significantly smaller compared with that by FLAIR sequence ( P<0.05). Fifty-seven patients were with DWMH (44 into the mild group and 13 into the moderate to severe group); the DWMH volume detected by FLAIR and T2WI sequences was significantly larger than that by DIR sequence ( P<0.05). (2) A total of 60 isolated lesions were detected, ranged 5.0-9.1 mm in length; isolated lesions enjoying significantly larger cross-sectional area, higher signal intensity, and lower contrast detected by FLAIR and T2WI sequences compared with those by DIR sequence ( P<0.05); isolated lesions enjoying significantly higher signal intensity and contrast detected by T2WI sequence compared with those by FLAIR sequence ( P<0.05). Conclusion:DIR sequence enjoys better effect in detecting WMH than FLAIR and T2WI sequences; the mismatch area of DIR sequence with FLAIR or T2WI sequences suggests WMH penumbra.
6.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
7.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
8.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
9.Effect of modified attention and interpretation therapy on fatigue and sleep quality in patients with post-stroke hemiplegia
Jie CHENG ; Lu CHEN ; Qing MA ; Siqi ZHENG ; Yuhan WANG ; Yunlong WANG
Sichuan Mental Health 2024;37(5):427-432
Background Patients with post-stroke hemiplegia are likely to experience fatigue and sleep disorder.Attention and interpretation therapy(AIT)has been shown to promote psychological flexibility,thereby alleviating their stress,improving emotional management and somatopsychic adaptation.Currently,there is a lack of application of AIT in patients with post-stroke hemiplegia.Objective To explore the effect of modified AIT on fatigue and sleep quality in patients with post-stroke hemiplegia,so as to provide references for physical and mental rehabilitation nursing of post-stroke hemiplegia patients.Methods A total of 120 patients with post-stroke hemiplegia attending the rehabilitation medicine department of North China University of Science and Technology Affiliated Hospital from August 1,2021 to June 30,2022 and fulfilling the Chinese guidelines for diagnosis and treatment of acute ischemic stroke 2018 and the Chinese guidelines for diagnosis and treatment of acute intracerebral hemorrhage 2019 were enrolled.Patients were assigned into two groups using random number table methods,each with 60 cases.Control group was given chronic illness trajectory model-based nursing,while study group received modified AIT intervention.All participants were evaluated using the Chinese version of Neurological Fatigue Index for Stroke(NFI-Stroke)and Pittsburgh Sleep Quality Index(PSQI)at the baseline,after 4 weeks and 8 weeks of intervention.Results The repeated measures ANOVA on PSQI total score and scores on sleep quality,sleep time,sleep duration,sleep efficiency,sleep disturbance and daytime dysfunction revealed a significant group effect,time effect and interaction effect(Fgroup=4.281,5.598,8.814,4.351,4.302,4.091,7.608,Ftime=122.230,19.698,19.289,16.403,15.421,28.879,90.876,Finteraction=19.508,3.227,11.586,5.237,5.507,5.799,3.338,P<0.05).Significant group effect,time effect and interaction effect were reported on NFI-Stroke total score and scores on physical subscale and cognitive subscale(Fgroup=7.140,5.466,5.547,Ftime=362.192,309.817,70.888,Finteraction=21.079,13.430,13.354,P<0.05).Conclusion Modified AIT may help alleviate fatigue and improve sleep quality in patients with post-stroke hemiplegia.
10.Investigation of coordinated development between blood banks and apheresis plasma collection banks
Qun LIU ; Dunzhu GONGJUE ; Qian ZHANG ; Hui YE ; Hua SHEN ; Mingming QIAO ; Linwei LI ; Xingzhe ZHANG ; Xiangwen CHEN ; Liliang CHEN ; Yang LIU ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(8):927-932
Objective To explore the factors that affect the coordinated development of blood banks and apheresis plas-ma collection banks(hereinafter referred to as plasma banks),and explore feasible measures for the coordinated develop-ment of blood banks and plasma banks.Methods The blood information management system and blood source information management system were used to retrieve related data of blood and plasma donation from 9 cities in Shandong province from 2017 to 2021.The number of blood donors and plasma donors and the intersection of them were analyzed.The data analysis was performed using chi-square test,and a questionnaire survey was conducted to investigate the policies and information status,as well as expectations for coordinated development for blood and plasma donation.Results From 2017 to 2021,the total number of blood donors in 9 cities was higher than that of plasma donors,both have been increasing year by year,and the increase in plasma donors was significantly higher than that of blood donors(131.78%vs 23.90%,P<0.05).The inter-section proportion of blood and plasma donors had increased from 0.45%in 2017 to 1.04%in 2021,with an increase of 131.11%.Among the administrative regions where the participating blood and plasma banks located,94.2%have not re-leased relevant policy to promote the coordinated development of blood and plasma donation.The majority(63%)expected blood banks and plasma banks to be set at a distance more than 50 km apart.The top four functional requirements for the in-terconnection between blood banks and plasma banks management information system were blood test results(94.61%),ID number(87.54%),blood and plasma donation records(85.51%)and health consultation/examination results(82.15%).The top four elements of coordinated development between blood and plasma banks were policy support(96.25%),informa-tion networking(92.36%),top-level design(87.44%)and cultural construction(86.58%).Conclusion The number of donors who donate both blood(mainly whole blood)and plasma has been increasing year by year,which deserves our close attention.To achieve the coordinated development of blood donation and plasma donation,policy support is the most crucial and fundamental means.Establishment of a standard system and the share of blood and plasma donation information is neces-sary for blood informatization construction.It was critical to promote the coordinated development of blood and plasma dona-tion and ensure blood safety with improving legislation,formulating policies for coordinated development,strengthening top-level design,standardizing the publicity of blood and plasma donation and establishing the idea that blood and plasma dona-tion are equally honorable.

Result Analysis
Print
Save
E-mail