1.Effect of "Fahan" on Metabolites of Blumea balsamifera Analyzed by Non-targeted Metabolomics
Jiayuan CAO ; Xin XU ; Xiangsheng ZHANG ; Bingnan LIU ; Yongyao WEI ; Ke ZHONG ; Yuxin PANG
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(2):200-207
		                        		
		                        			
		                        			ObjectiveTo characterize the changes of metabolites of Blumea balsamifera in the process of sweating by non-targeted metabolomics, and to investigate the influence of sweating processing on the constituents of B. balsamifera. MethodsUltra performance liquid chromatography-quadrupole/electrostatic field orbitrap high resolution mass spectrometry(UPLC-Q-Exactive Orbitrap-MS) metabolomics was used to identify the metabolites in no sweating group(F1), sweating 2 d group(F2) and sweating 4 d group(F3), the differences of metabolites between the groups were compared by principal component analysis(PCA) and orthogonal partial least squares-discriminant analysis(OPLS-DA), and differential metabolites were screened according to the variable importance in the projection(VIP) value>1 and P<0.05, and the pathway enrichment of the differential metabolites was analyzed by Kyoto Encyclopedia of Genes and Genomes(KEGG). ResultsThe results of PCA and OPLS-DA showed a clear distinction between the three groups of samples, indicating significant differences in the compositions of the three groups of samples. A total of 433 differential metabolites were screened between the F1 and F2, with 154 up-regulated and 279 down-regulated, the significant up-regulated metabolites were tangeritin, 5-O-demethylnobiletin and so on, while the metabolites with significant down-regulation included alternariol, fortunellin, etc. A total of 379 differential metabolites were screened between the F2 and F3, with 150 up-regulated and 229 down-regulated, the significant up-regulated metabolites were isoimperatorin, helianyl octanoate and so on, and the significant down-regulated metabolites were hovenoside I, goyasaponin Ⅲ, etc. KEGG pathway enrichment analysis showed that tyrosine metabolism, isoquinoline alkaloid biosynthesis, phenylalanine, tyrosine and tryptophan biosynthesis, tryptophan metabolism, valine, leucine and isoleucine biosynthesis, pantothenate and coenzyme A biosynthesis may be the key pathways affecting metabolite differences of B. balsamifera after sweating treatment. ConclusionSweating can reduce the content of endophytic mycotoxins in B. balsamifera and has a great impact on the synthesis and metabolic pathways of total flavonoids and auxin. This study can provide a reference for the process research on the sweating conditions of B. balsamifera. 
		                        		
		                        		
		                        		
		                        	
2.Analysis of the trend of radiological diagnostic examination frequency and the related influencing factors
Yongxian ZHANG ; Yantao NIU ; Tianliang KANG ; Yunfu LIU ; Liping XU ; Lin XU ; Senlin GUO ; Dandan LIU ; Binbin YU ; Junfang XIAN
Chinese Journal of Radiological Medicine and Protection 2024;44(1):29-35
		                        		
		                        			
		                        			Objective:To investigate the trend of radiological diagnostic examination frequency and the related influencing factors in a general hospital in recent four years.Methods:The hospital information system and the radiology information system were used to collect the information on the numbers of the outpatients, the emergency patients, and the inpatients and the radiology examination information from 2019 to 2022. The examination frequency and proportion of various imaging equipment were counted by using the perspective table of data, and the examination items and the proportion of the radiological diagnostic examinations were calculated. The positive rates of the radiological examinations were measured from 2019 to 2022. The gender and age distribution of the patients were analyzed. Spearman correlation analysis was used to analyze the relationships between the numbers of the patients undergoing radiological examinations and the numbers of the outpatients, emergency patients and the inpatients.Results:The annual frequency of radiological diagnostic examinations from 2019 to 2022 were 307 306, 245 418, 317 250 and 325 625, respectively, with a total of 1 195 599. Among them, the proportions of CT, X-rays, bedside X-rays, bone density, gastrointestinal imaging and mammography were 59.74%, 38.04%, 1.39%, 0.42%, 0.21% and 0.19%, respectively. In each year, the proportion of CT in all radiological diagnostic examinations was 49.58%, 63.40%, 60.40% and 65.20%, respectively. The frequency of emergency CT and emergency chest CT was correlated with the number of emergency patients( r =0.63, 0.61, P<0.05), and the frequency of non-emergency CT was correlated with the number of outpatients and inpatients ( r =0.61, 0.66, P<0.05). The positive rates of the CT examinations were higher than 80% except the lowest of 79.95% in 2021. Conclusions:Radiological examinations especially CT examinations have increased significantly, and played an important role in the diagnosis of diseases. However, attention should be paid to the Justification of the CT examinations. Timely statistical analysis of radiological examination information can provide data supports and references for scientific management of radiological examinations.
		                        		
		                        		
		                        		
		                        	
3.A controlled study on the impacts of different scanning protocols on image quality and radiation dose in chest CT
Chulin XU ; Wentao MA ; Yongxian ZHANG ; Yunfu LIU ; Tianliang KANG ; Senlin GUO ; Yantao NIU
Chinese Journal of Radiological Medicine and Protection 2024;44(9):789-796
		                        		
		                        			
		                        			Objective:To explore and compare the impacts of different scanning protocols on image quality and radiation dose in chest computed tomography (CT) scans.Methods:A retrospective analysis was conducted for the data of 65 randomly selected patients who underwent chest CT scans using a tube voltage of 120 kV, the automatic modulation technique for tube current, and z-axis radiation dose modulation at the Emergency Department of our hospital from June to July 2023. The enrolled cases were divided into two groups: the high-resolution group ( n = 34) and the conventional group ( n = 31), with the settings for scanning protocols identical to those for phantom scans. For patients in both groups, thin-layer images of the cross-sections in the lung and mediastinal windows were reconstructed using thickness/intervals of 1 mm/1 mm and 2 mm/1 mm, respectively. Meanwhile, high-resolution and conventional CT scans were conducted using a Catphan500 phantom under a tube voltage of 120 kV and a tube current of 150 mAs. Of both scanning protocols, the high-resolution CT scan utilized the lung nodule-orientated scanning mode, pitch of 1.5, and a detector combination providing a collimation of 16 × 0.75 mm. In contrast, the conventional CT scan was performed using the body-orientated scanning mode, pitch of 0.813, and a detector combination providing a collimation of 16 × 1.5 mm. Then, the high-contrast resolutions of the phantom images obtained using the two scanning protocols were objectively evaluated. Both coronal chest images in the lung window and cross-sectional images in the mediastinal window were reconstructed with a thickness/interval of 5 mm/5 mm for both groups. Then, the obtained images were imported into the Radimetrics system to compare the body size-specific dose estimation (SSDE), doses to sensitive organs on the body surface, and scanning time of both groups. For the cross-sectional images in the mediastinal window, the contrast-noise-ratio (CNR), signal-to-noise ratio (SNR), and figure-of-merit (FOM) were measured and calculated at the fixed anatomical parts. For the cross-sectional images in the lung window, their quality was subjectively evaluated by two senior diagnostic radiologists. Results:The result of phantom scans indicated that high-resolution CT scans yielded images with an approximately 5% increase in the spatial resolution in the xy-plane and a nearly 20% increase in the spatial resolution along the z-axis compared to conventional CT scans. The result of clinical data demonstrated that the conventional group exhibited significantly higher doses to the thyroid and the female breast ( t = 2.8, 2.3, P < 0.05), along with notably elevated SNR, CNR, and FOM values of the right trapezius, compared to the high-resolution group ( t = 4.1, 5.8, z=4.4, P < 0.001). However, the high-resolution group manifested significantly higher SNR, CNR, and FOM values of the thoracic aorta compared to the conventional group ( t = 3.4, 4.4, z=3.4, P < 0.001). In addition, the cross-sectional and coronal images in the lung window of the clinical cases in the high-resolution group exhibited more stable quality, with subjective scores exceeding 4 and the average scores of both groups not statistically significantly different. Conclusions:For chest CT examination, high-resolution CT scans are more suitable for observations focusing on the details of the lungs and mediastinum, while conventional CT is more suitable for those centering on soft tissues on the body surface.
		                        		
		                        		
		                        		
		                        	
4.Key points for differential diagnosis between nasal NK/T-Cell lymphoma and chronic rhinosinusitis
Yi DONG ; Shunjiu CUI ; Qian HUANG ; Yan SUN ; Yunfu LIU
Chinese Archives of Otolaryngology-Head and Neck Surgery 2024;31(10):642-646
		                        		
		                        			
		                        			OBJECTIVE To compare the clinical characteristics of natural killer/T-cell lymphoma(NKTL),and chronic rhinosinusitis(CRS),analyzing key points for differential diagnosis.METHODS Data from 29 nasal NKTL cases and 54 CRS cases were collected and compared,including medical history,clinical presentations,and imaging data.RESULTS The NKTL group had a shorter duration of symptom appearance(P<0.001)and more frequent symptoms of bloody nasal discharge(P=0.002).There was diffuse mucosal swelling of the turbinates and nasal septum(P<0.001),and signs of structural destruction within the nasal cavity(P=0.024).MRI more frequently showed involvement of the inferior turbinate(P=0.034),nasal septum(P<0.001),nasopharynx(P=0.002),and skull base(P=0.024),with cast-like changes or extranasal infiltration.The CRS group more frequently reported symptoms of olfactory reduction(P<0.001),swelling in the middle nasal meatus,and nasal masses(P<0.001).CT more commonly showed sinus bone hyperplasia(P=0.002).CONCLUSION Compared to CRS,nasal NKTL has a shorter symptom duration,commonly presents with diffuse nasal swelling and structural destruction both inside and outside the nasal cavity.MRI frequently shows involvement of the inferior turbinate,nasal septum,nasopharynx,and skull base,along with cast-like features and skip infiltration.
		                        		
		                        		
		                        		
		                        	
5.Feasibility study of ethmoidal foramen in the medial wall of the orbit based on 10 μm ultra-high resolution CT
Xiwen WANG ; Ping WANG ; Yongxian ZHANG ; Yue KANG ; Yue SHI ; Yunfu LIU ; Zhaohui LIU
Chinese Archives of Otolaryngology-Head and Neck Surgery 2024;31(10):647-651
		                        		
		                        			
		                        			OBJECTIVE To investigate the feasibility of ultra-high resolution CT(U-HRCT)in demonstrating and evaluating ethmoidal foramen in the medial wall of the orbit.METHODS Nine cadavers(18 side orbits)fixed in 10%buffered formalin were enrolled and underwent U-HRCT and multislice helical CT(MSCT).Subjective and objective evaluations of image quality were performed by two experienced radiologists independently.Anterior,middle,and posterior ethmoidal foramen(AEF,MEF,and PEF)were recorded and the distance among them was measured.RESULTS The results of subjective and objective evaluations were not significant differences between evaluators and consistency was strong.CNR of U-HRCT and MSCT were 43.09±8.87 and 11.04±0.66 and SNR were 2.13±1.45 and 0.55±0.13,respectively.CNR and SNR of U-HRCT were significantly higher than MSCT(P<0.05).Objective scores of the U-HRCT and MSCT groups were 10.00 points(9.00 points,10.00 points)and 6.00 points(5.75 points,7.00 points).Objective scores of the U-HRCT were higher than MSCT(P<0.05).All eighteen AEF were shown by U-HRCT and MSCT.Among 18 PEF showed by U-HRCT,17 of them demonstrated by MSCT,and no significant difference was found in the display rate between groups(P>0.05).Nine MEF(7 single hole and 2 double holes)were found by U-HRCT,but only 2 of them were shown by MSCT.The MEF display rate of U-HRCT was higher than MSCT(P<0.05).The distance from MEF to AEF,from MEF to PEF,and from AEF to PEF were(9.43±1.13)mm,(4.75±1.09)mm,(14.18±1.14)mm,respectively.CONCLUSION U-HRCT is better to evaluate ethmoidal foramen than MSCT.It could be used to show the number and position of ethmoidal foramen before surgery to avoid complications.
		                        		
		                        		
		                        		
		                        	
6.Assessment of Radiation Shielding Requirements in Room of Radiotherapy Installations—Part 1: General Principle (GBZ/T 201.1—2007): A survey of relevant personnel in technical service institutions
Hezheng ZHAI ; Quan WU ; Yunfu YANG ; Wei LI ; Xiaojun CHENG ; Chuanpeng HU ; Hailiang LI ; Zechen FENG ; Ribala HA ; Xiao XU ; Deming LIU ; Chuanwen WANG ; Chunyong YANG
Chinese Journal of Radiological Health 2023;32(5):479-483
		                        		
		                        			Objective  :
		                        			To evaluate the implementation, application, and problems and suggestions of the Radiation Shield-
ing Requirements in Room of Radiotherapy Installations—Part 1: General Principle (GBZ/T 201.1—2007) through a survey of relevant personnel in radiation health technical service institutions, and to provide a scientific basis for further revision and implementation of this standard.
		                        		
		                        			Methods:
		                        			A questionnaire survey was conducted among randomly selected per-
sonnel in radiation health technical services across China, which mainly investigated the awareness, training, application, and
revision suggestions related to the GBZ/T 201.1—2007. The results were aggregated and analyzed.
		                        		
		                        			Results:
		                        			A total of 184 evaluation questionnaires on the GBZ/T 201.1—2007 were collected from technical service staff in 25 provinces. Among the
responders, 64.1% thought that the standard had been widely applied; 91.8% thought that the standard could meet work
needs; only 54.3% ever received relevant training on the standard; 68.5% used the standard once or more per year; 33.7% thought that the standard needed to be revised.
		                        		
		                        			Conclusion
		                        			The personnel in radiation health technical services have a high
awareness rate of the GBZ/T 201.1—2007 and its contents, but their familiarity with and application of the standard need to
be improved. Relevant departments should strengthen the training and promotion of the standard, and part of the standard should be revised.
		                        		
		                        		
		                        		
		                        	
7.Study on the effect of virtual grid on chest X-ray image quality
Tianliang KANG ; Yunfu LIU ; Yongxian ZHANG ; Senlin GUO ; Wentao MA ; Yantao NIU
Chinese Journal of Radiology 2023;57(5):547-552
		                        		
		                        			
		                        			Objective:To explore the image quality and its evaluation method using virtual grid under different tube voltages in the clinical chest X-ray exam.Methods:According to the conditions of chest X-ray photography commonly used in clinical practice, the corresponding thickness of plexiglass (20 cm, including CDRAD phantom) was determined as the experimental object. With a fixed tube loading of 4 mAs and the tube voltage from 60 to 125 kV, the experimental object was imaged in three ways: physical grid, none grid and virtual grid. The common physical parameters (CNR, σ, C, SNR), texture analysis (Angular second moment, texture Contrast, Correlation, Inverse difference moment, Entropy) and CDRAD phantom score (IQF inv) were evaluated. Two-way ANOVA test was used for each group of common physical parameters, and further pairwise comparisons were made. At the same time, applying virtual grids on the obtained images with chest anthropomorphic model and texture indexing the images with and without virtual grids, then rank sum test of paired sample can be conducted. Results:There were differences in image quality among the three groups of grid mode( P<0.05), and the physical grid delivered the best image quality. The tube voltage had an impact on all image quality evaluation indexes ( P<0.05). The tube voltage was positively correlated with CNR, SNR, angular second moment, inverse difference moment and IQF inv ( P<0.05), and negatively correlated with σ, C, texture contrast and entropy ( P<0.05). There was no significant correlation between the tube voltage and Correlation ( P>0.05). The chest anthropomorphic model images were used to evaluate the virtual grids, and the texture indexes (Angle second moment, Contrast, Correlation, Inverse difference moment, Entropy) were statistically significant (P<0.05). Conclusions:The virtual grid can improve the image quality of chest X-ray photography, and the image texture analysis method can be a useful supplement to the image quality evaluation parameters.
		                        		
		                        		
		                        		
		                        	
8.The effect of CT detector width and signal acquisition positions on image quality
Senlin GUO ; Yue REN ; Yongxian ZHANG ; Tianliang KANG ; Yunfu LIU ; Lei ZHU ; Yantao NIU
Chinese Journal of Radiology 2023;57(6):684-688
		                        		
		                        			
		                        			Objective:To evaluate the influence of different detector widths and signal acquisition positions of wide-detector CT in different scanning modes on CT number and noise, and to provide a basis for reasonable selection of scanning modes and related parameters in clinical practice.Methods:The body dose phantom was scanned by GE Revolution CT. The scan was performed with detector widths of 40, 80 and 160 mm in sequential scanning mode and with detector width/pitch combinations of 40 mm/0.516, 40 mm/0.984, 80 mm/0.508 and 80 mm/0.992 in spiral scanning mode. The phantom was placed at the central and peripheral of the selected detector widths, and the adjacent positions between two axial scans. The images of the phantom were evaluated subjectively and the CT numbers and SDs were measured. The differences between the measured values at different imaging parameters were compared. The multi-group Friedman test was used to compare CT numbers and SD under different scanning parameters in sequential scanning mode, and the Wilcoxon test was used to compare CT numbers and SD in spiral scanning mode.Results:There was no statistically significant difference in the geometric shapes of the phantom images obtained at any combination of parameters. In sequential scanning mode, the differences at different detector widths were statistically significant (χ 2=14.00, P=0.001) with CT numbers at 40 mm and 160 mm greater than CT numbers at 80 mm ( P<0.05). The differences at different signal acquisition positions were statistically significant (χ 2=12.04, P=0.002) with CT numbers at peripheral and adjacent greater than CT numbers at central ( P<0.05). In spiral scanning mode CT numbers at detector width at 80 mm were greater than CT numbers at 40 mm ( Z=-2.10, P=0.036). For SD, the differences at different detector widths were statistically significant in sequential scanning modes (χ 2=8.17, P=0.017) with SD at 160 mm greater than SD at 80 mm ( P<0.05). The differences at different signal acquisition positions were statistically significant (χ 2=13.50, P=0.001) with SD at peripheral greater than SD at central ( P<0.05). In spiral scanning mode SDs at pitches 0.984 and 0.992 were greater than SDs at 0.516 and 0.508 ( Z=-2.66, P=0.008). There were no significant differences among other groups. Conclusion:The selection of scanning mode, detector width and signal acquisition position of wide-detector CT will affect the image CT numbers and SDs.
		                        		
		                        		
		                        		
		                        	
9.Effect of neck CT arteriovenous simultaneous enhancement methods on image quality and radiation dose
Yunfu LIU ; Tianliang KANG ; Yongxian ZHANG ; Senlin GUO ; Lin FU ; Qinggang XU ; Yingying CAO ; Junfang XIAN ; Yantao NIU
Chinese Journal of Radiology 2023;57(7):756-761
		                        		
		                        			
		                        			Objective:To investigate the feasibility of simultaneous arteriovenous enhancement of neck CT with two-stage injection of contrast agent and its effect on image quality and radiation dose.Methods:A total of 30 patients undergoing neck CT enhancement scan due to space-occupying lesions in Beijing Tongren Hospital, Capital Medical University from February to April 2022 were prospectively included as the experimental group. The neck CT enhancement scan was performed with two-stage injection of contrast agent and arteriovenous simultaneous enhancement. The dosage of contrast agent was calculated according to the patient′s body weight, and the method of two-stage injection was adopted. The dosage of contrast agent in the first stage was 0.7 ml/kg, with normal saline in the middle stage, and the second stage (began at 35 s) was 0.3 ml/kg. A total of 30 patients with gender and age matching with the experimental group from December 2021 to January 2022 were retrospectively collected as the control group. The control group was treated with the traditional arterial phase and venous phase scanning method with the dosage of 1.0 ml/kg contrast agent. The arterial phase was scanned at the 30 s and the venous phase was scanned at the 60 s. The CT values of bilateral carotid arteries and jugular veins in the experimental group were measured, the CT values of bilateral carotid arteries in the arterial phase were measured in the control group, and the CT values of bilateral carotid arteries and jugular veins in the venous phase were measured. Carotid artery enhancement score was performed for images of experimental group and control group in arterial and venous phase, and jugular vein and lesion enhancement score was performed for images of experimental group and control group in venous phase. The effective dose was calculated for both groups. The difference of carotid artery CT values between images was compared by one-way analysis of variance, and LSD method was used for pairwise comparison. The CT values of jugular vein were compared using independent sample t test. Kruskal-Wallis test was used to compare carotid artery enhancement scores, and Nemenyi method was used for pairwise comparison. Jugular vein and lesion enhancement scores and effective dose were compared by Mann-Whitney U test. Results:The CT value of carotid artery of experimental group [left (276±24) HU, right (273±25) HU] was lower than that of control group in arterial phase [left (329±33) HU, right (327±32) HU], and higher than that in the venous phase [left (147±15) HU, right (148±16) HU]. All the differences were statistically significant ( P<0.001). The CT value of jugular vein of experimental group [left (206±18) HU, right (203±19)] was higher than that of control group in the venous phase [left (154±15) HU, right (151±15)], the difference was statistically significant ( t=11.88, 11.76, both P<0.001). There was no significant difference in carotid artery enhancement score between experimental group and control group in arterial phase ( P=0.624), but the carotid artery enhancement score of the experimental group was higher than that of the control group in the venous phase, and the difference was statistically significant ( P<0.001). The scores of jugular vein and lesion enhancement in experimental group were higher than those of control group in venous phase, and the difference was statistically significant ( Z=5.01, P<0.001). The effective dose of the experimental group [2.41(2.04, 2.72) mSv] was decreased by 52.2% compared with the control group [5.04(4.18, 5.44) mSv], and the difference was statistically significant ( Z=-6.24, P<0.001). Conclusions:The neck CT enhanced scan with two-stage injection of contrast agent and arteriovenous simultaneous enhancement method can obtain comprehensive images of arterial and venous phases, and realize simultaneous enhancement of carotid artery, jugular vein and lesions, and reduce radiation dose.
		                        		
		                        		
		                        		
		                        	
            
Result Analysis
Print
Save
E-mail