1.A self-designed wound measurement grid in design of lobulated perforator flap
Wanggao ZHOU ; Xuelang YE ; Zhenwei ZHANG ; Jiachuan ZHUANG ; Dongyang LI ; Shaoxiao YU ; Zheng LI ; Yuhai KE ; Huixin LIN ; Yi XIONG
Chinese Journal of Microsurgery 2023;46(5):552-557
Objective:To explore the clinical effect of a self-designed wound measurement grid on the design of lobulated perforator flap.Methods:From January 2019 to December 2022, soft tissue defects in limbs of 9 patients were reconstructed by lobulated perforator flaps in the Department of Orthopaedics and Traumatology of Shenzhen Hospital of Integrated Traditional Chinese and Western Medicine. The patients were 7 males and 2 females aged 21-55 years old with 40.3 years old in average. There were 6 upper limb defects and 3 lower limb defects. Self-designed wound measuring grids were applied to guide the design and excision of lobulated perforator flaps during surgery. Five patients were treated by lobulated perforator flap pedicled with the descending branch of lateral circumflex femoral artery and 4 by perforator flaps pedicled with dorsal interosseous artery. The areas of soft tissue defect were 4.0 cm×1.5 cm-26.0 cm×8.0 cm, and the sizes of the flaps were 4.5 cm×1.8 cm-22.0 cm×10.0 cm. After surgery, the blood supply of flaps, flap survival and wound healing were monitored. Flap survival, donor site recovery and limb function were observed at outpatient clinic over the postoperative follow-up, and the limb function was evaluated by the Evaluation Standard of Upper Limb Partial Functional of Hand Surgery of Chinese Medical Association and Lower Extremity Measure(LEM).Results:In this study, a total of 17 of 18 lobes of the lobulated perforator flaps survived after surgery. One flap had venous occlusion and after exploration and further treatment, a necrosis occurred in 1 lobe of the lobulated flap and then a free flap transfer was performed again. All the wounds achieved stage-I healing. Postoperative follow-up lasted for 3-18 months with 8.6 months in average. All flaps had good colour and texture, satisfactory appearance and only linear scars remained in the donor sites, without pain and scar contracture. The reconstructed upper extremity defect were evaluated according to the Evaluation Standard of Upper Limb Partial Functional of Hand Surgery of Chinese Medical Association, with 4 patients were in excellent and 2 in good. The reconstructed lower extremity defects were evaluated according to the LEM, and 2 patients were in excellent and 1 in good.Conclusion:The self-designed wound measurement grid was successfully applied in the design of lobed perforator flaps. It can accurately measure a wound surface and quickly extract a wound profile, and it is more convenient and intuitive to guide the design of flaps. It has a good effect in clinical application and further clinical trials are required.
2.Flow-through perforator flap of posterior interosseous artery in repair of dorsal digital soft tissue defect with disorder of blood supply in digital tip
Wanggao ZHOU ; Zhenwei ZHANG ; Shaoxiao YU ; Dongyang LI ; Yewen CHEN ; Xuelang YE ; Yi XIONG ; Yuhai KE
Chinese Journal of Microsurgery 2022;45(3):284-288
Objective:To investigate the clinical effect of Flow-through perforator flap of posterior interosseous artery in repair of dorsal digital soft tissue defect with disorder of blood supply in digital tip.Methods:From January 2018 to June 2020, 12 patients who had digital dorsum soft tissue defect with digital tip blood supply disorder were treated with Flow-through perforator flap of posterior interosseous artery. The size of flaps was 2.0 cm× 2.0 cm-5.5 cm×3.0 cm. The posterior interosseous artery in the flap was bridged with the proper palmar artery of digit, 1 subcutaneous vein in the flap was anastomosed with the dorsal subcutaneous vein, and 1 subcutaneous vein in the posterior interosseous artery with the palmar subcutaneous vein. The donor sites were sutured directly. The wound healing, blood supply of digit and flap survival were observed after operation. The quality of flap survival and digital joint function were observed in the follow-up reviews at outpatient clinic.Results:All the 12 Flow-through perforator flaps of posterior interosseous artery survived, the blood supply of digit was good, and the wounds healed in the first stage. The follow-up period was 6-24 months. The appearance and texture of the flaps were good without obvious bloating. Only linear scar was left in the forearm donor site. According to the Trial Standard of Upper Limb Function Evaluation of Chinese Society of Hand Surgery, the results were excellent in 11 cases and good in 1 case.Conclusion:The perforator flap of posterior interosseous artery has constant anatomy, and the diameter of blood vessel matches the blood vessels of digits. It is suitable for Flow-through technique. It has less subcutaneous tissue, no secondary thinning, and the donor site can be closed directly. It is a good method to repair the dorsal soft tissue defect with disorder of digital end blood circulation.
3.Avian influenza A (H7N9) virus: from low pathogenic to highly pathogenic.
William J LIU ; Haixia XIAO ; Lianpan DAI ; Di LIU ; Jianjun CHEN ; Xiaopeng QI ; Yuhai BI ; Yi SHI ; George F GAO ; Yingxia LIU
Frontiers of Medicine 2021;15(4):507-527
The avian influenza A (H7N9) virus is a zoonotic virus that is closely associated with live poultry markets. It has caused infections in humans in China since 2013. Five waves of the H7N9 influenza epidemic occurred in China between March 2013 and September 2017. H7N9 with low-pathogenicity dominated in the first four waves, whereas highly pathogenic H7N9 influenza emerged in poultry and spread to humans during the fifth wave, causing wide concern. Specialists and officials from China and other countries responded quickly, controlled the epidemic well thus far, and characterized the virus by using new technologies and surveillance tools that were made possible by their preparedness efforts. Here, we review the characteristics of the H7N9 viruses that were identified while controlling the spread of the disease. It was summarized and discussed from the perspectives of molecular epidemiology, clinical features, virulence and pathogenesis, receptor binding, T-cell responses, monoclonal antibody development, vaccine development, and disease burden. These data provide tools for minimizing the future threat of H7N9 and other emerging and re-emerging viruses, such as SARS-CoV-2.
Animals
;
COVID-19
;
China/epidemiology*
;
Humans
;
Influenza A Virus, H7N9 Subtype
;
Influenza in Birds/epidemiology*
;
Influenza, Human/prevention & control*
;
Poultry
;
SARS-CoV-2
4.The free flap from the superficial palmar branch of radial artery innervated by the lateral cutaneous nerve of the forearm repair the defects of finger pulp
Yuhai KE ; Zheng LI ; Zhixin LI ; Huixin LIN ; Lefeng CHEN ; Wanggao ZHOU ; Yi XIONG ; Jinhao ZENG ; Shaoxiao YU ; Zhenwei ZHANG
Chinese Journal of Microsurgery 2017;40(6):533-535
Objective To explore the outcomes of free flap from the radial artery superficial palmar branch (RASP) innervated by the lateral cutaneous nerve of the forearm for repairing the defects of finger pulp. Methods From April, 2013 to February, 2015, 20 fingers in 20 cases were treated with free flap from RASP innervated by the lateral cutaneous nerve of the forearm. The area of flap was from 1.8 cm×2.0 cm to 2.0 cm×4.0 cm. Postoperative fol-low up was done termly. Results All 20 flaps survived. All cases were followed-up for 7-20 months ( averag, 12 months). The flaps appeared well with good texture. The two-point discrimination was from 7 mm to 12 mm, and grad-ed with S3 and S3+sensation. There was little scar noted at the donor site in the wrist. There was no influence of hand and wrist function. Conclusion The method of using free flap from SASP innervated by the lateral cutaneous nerve of the forearm to repair the defects of finger pulp has good clinical effect.
5.Ribavirin is effective against drug-resistant H7N9 influenza virus infections.
Yuhai BI ; Gary WONG ; Yingxia LIU ; Lei LIU ; George F GAO ; Yi SHI
Protein & Cell 2016;7(8):611-614
6.Highly diversified Zika viruses imported to China, 2016.
Yanjun ZHANG ; Wenxian CHEN ; Gary WONG ; Yuhai BI ; Juying YAN ; Yi SUN ; Enfu CHEN ; Hao YAN ; Xiuyu LOU ; Haiyan MAO ; Shichang XIA ; George F GAO ; Weifeng SHI ; Zhiping CHEN
Protein & Cell 2016;7(6):461-464
7.Percutaneous vertebroplasty for treatment of metastatic tumor in axis
Gang SUN ; Peng JIN ; Yuhai YI ; Xunwei LIU ; Fandong LI ; Zhiyong XIE ; Xuping ZHANG ; Min LI
Chinese Journal of Radiology 2010;44(4):421-423
Objective To explore the safety and effectiveness of percutaneous vertebrophasty(PVP)in the treatment of the metastatic tumor involved axis.Methods Ten patients(8 male,2 female)with osteolytic metastases involved axis were treated with PVPs.The anterolateral approach with fluoroscopy guidance was selected in 9 cases,while the posterolateral approach with CT guidance was selected in 1 case.Results Successful unilateral-paracentesis for PVP were achieved in all patients without intervention related complications such as bleeding and symptomatic polymethylmethacrylate(PMMA)leakage.CT scan taken following PVP showed that over 70% of the osteolytic metastatic area was well filled with PMMA in all cases.Varying degrees of pain relief were observed(CR in 7 cases,PR in 3 cases)within 7 days.All patients could support their heads without brackets.During a 3 to 24 months follow up after the procedures,No aggravated pain was found in the group.Two patients died in 4 months,3 Patients died in 8 to 11 months 4 patients died in 13 to 15 months,and 1 patient still was alive after 24 months.Conclusion Anterolateral or posterolateral approach to Aixs in PVP is safe and effective in treating osteolytic metastatic tumors.
8.Flow-injection-enhanced chemiluminescence method for the determination of three β-blockers
Lijuan WANG ; Yuhai TANG ; Baoping LI ; Honglang LIU ; Jingfeng YI
Journal of Pharmaceutical Analysis 2010;22(2):91-96
Objective To develop a rapid, simple and sensitive chemiluminescence method for the determination of three β-blockers (bisoprolol, atenolol and propranolol). Methods The chemiluminescence of cerium (Ⅳ)-sulfite system was obviously sensitized by adding anyone of three β-blockers in acid media. A new chemiluminescence method was set up by combining with flow-injection technique and used to determine the three β-blockers. Results Good linear ranges were obtained at the concentrations of 2.0×10-7g/mL-4.0×10-5g/mL, 1.0×10-7g/mL-3.0×10-5g/mL and 7.0×10-7g/mL-1.0×10-5g/mL, respectively, with the detection limits of 5.0×10-8g/mL, 7.0×10-8g/mL and 5.0×10-8g/mL (S/N=3), respectively, and the relative standard deviations for 11 times consecutive injections of 1.0×10-6g/mL bisoprolol, atenolol and propranolol were 3.57%, 2.21% and 2.26%, respectively. Conclusion The developed method is sensitive, accurate, rapid and of low cost. And it can be applied to determine bisoprolol, atenolol and propranolol in pharmaceutical preparations.
9.Kyphoplasty with single balloon inflation followed by cement filling for osteoporotic vertebral compression fractures
Gang SUN ; Peng JIN ; Xunwei LIU ; Zhiyong XIE ; Fandong LI ; Yuhai YI ; Xuping ZHANG ; Runsong HAO
Chinese Journal of Tissue Engineering Research 2008;12(6):1179-1183
BACKGROUND: In kyphoplasty procedure, two balloons are inserted into the vertebral body and inflated simultaneously for height symmetric restoration of the vertebral body. However, the expensive cost of balloon of kyphoplasty limits the extensive development of this procedure in developing countries. In this study, we try to inflate single balloon with bilateral transpedicular routes alternatively to achieve vertebral body height balanced restoration and reduce operation expenditure. But biocompatibility of bone cement and effect of kyphoplasty still need further observation.OBJECTIVE: To investigate the biocompatibility of bone cement and the clinical efficacy of bipedicular kyphoplasty for osteoporotic vertebral compression fractures by inserting single inflatable balloon into injured vertebral body and filling bone cement in the cavity caused by inflating balloon via bipedicular approach.DESIGN: Controlled observation.SETTING: Department of Medical Imaging, General Hospital of Jinan Military Area Command of Chinese PLA.PARTICIPANTS: Twenty-two patients (31 vertebral bodies) undergoing kyphoplasty with single balloon in Department of Medical Imaging, General Hospital of Ji'nan Military Area Command of Chinese PLA from May 2004 to May 2005 were selected, including 5 males and 17 females aged 68-85 years. Patients with painful compression fractures caused by osteoporosis were enrolled, and confirmed by CT and MRI with complete vertebral posterior wall but no spine deformity. The informed consent was obtained from all subjects, and the experiment and treatment were approved by Ethics Committee. METHODS: The especial instrument for kyphoplasty including puncturing device and balloon were provided by Shandong Guanlong Medical Utensils Co., Ltd. [LDAI (T) 2004 No. 2150017]; bone cement (Polymethymethacrylate) was made in China [MAIT 2005(T) No. 3650267]. Under X-ray fluoroscopy monitoring, single inflatable balloon was inserted into fractured vertebral body by puncturing needle and inflated via bipedicular approach to restore vertebral height. MAIN OUTCOME MEASURES: ①Bone cement biocompatibility during and after surgery; ②pain relief within 72 hours after surgery, restoration of vertebral height and correction of kyphotic deformity.RESULTS: ①Bone cement biocompatibility: Little cement leakage was observed at one intervertebral space of one patient by X-ray film, but no clinical symptoms, inflammatory reaction or rejection were found. ②Obvious pain relief was found in 22 cases with within 72 hours after kyphoplasty. ③The height loss of the anterior and middle vertebral body reduced from (14.70±4.21) mm and (10.62±4.11) mm preoperatively to (10.38±4.23) mm and (6.45±4.04) mm postoperatively after single balloon inflation and cement filling. Cobb angle was corrected averagely from (21.15±6.33)° preoperatively to (11.64±4.33)° postoperatively. CONCLUSION:Biocompatibility of bone cement is good, and no specific adverse effects are found in despite of cement leakage. Bipedicular kyphoplasty with single balloon for painful osteoporotic vertebral compression fractures effectively restores vertebral heights and relieves pain.
10.The preliminary study on a single balloon cross-medline expansion using unipedicular approach in kyphoplasty
Gang SUN ; Peng JIN ; Xunwei LIU ; Runsong HAO ; Zhiyong XIE ; Fandong LI ; Yuhai YI ; Xuping ZHANG
Chinese Journal of Radiology 2008;42(5):519-522
Objective To evaluate the clinical efficacy and safety of kyphoplasty with single balloon cross-midline expansion using unipedicular approach for osteoporotic vertebral body compressive fracture (OVCF).Methods Thirty six cases of painful OVCF were included in the study,with 61 vertebrae involved.Under X-ray fluoroscopy monitoring,kyphoplasty was performed using a unilateral,single,balloon via a unilateral transpedicular approach.A final balloon position was in the midline of the vertebral body with the balloon cross-midline expansions and bone cement filled. Clinical outcomes were determined by comparison of preoperative and postoperative VAS and ODI scores.Radiographic assessment included vertebral height restoration and correction of kyphosis.Follow-up was conducted for 6.0-12.0 months(mean 9.2 months).Results Thirty-six consecutive patients with 61 vertebrae were successfully operated with an operative time of(37.4±9.6)rain per vertebra.All patients had significant pain relief and functional recovery within 96 h after the procedure with no surgery-and device-related complications.VAS score improved from(7.3±1.0)preoperatively to(2.7±0.8)postoperatively(t=19.53,P<0.01).ODI score was decreased from(71.1±10.9)%preoperatively to(26.6±6.4)%postoperatively(t=18.54,P<0.01).The average anterior body height loss was(14.3±2.8)mm before procedure and(10.0±1.8)mm after procedure(t=14.68,P<0.01).The average middle body height loss was(10.2±2.7)mm before procedure and(5.9±1.8)mm after procedure(t=16.44,P<0.01).The Cobb's angle was corrected from 23.4°±5.0° to 16.2°±2.8°(t=15.60,P<0.01).Some leakages of cement around the anterior margin of vertebra and inter-vertebral space were found in 2 patients,but there were no clinical symptoms.X-ray examination indicated there were no cement leakages in other vertebra.The pain relief and functional recovery were substantial and maintained to the last follow up without any re-collapse or adjacent level fracture.Conclusions A single-balloon cross-midline expansion using unipedicular approach in kyphoplasty for OVCF is effective and safety,less operation time,less radiation exposure compared to the conventional kyphoplasty technique.

Result Analysis
Print
Save
E-mail