1.Effects of electroacupuncture at pterygopalatine region on NLRP3-mediated pyroptosis and inflammatory factors in allergic rhinitis rats.
Haiyang LV ; Meihui TIAN ; Shuyi SHE ; Yucheng LIU ; Lei SUN ; Wu SONG ; Yong TANG
Chinese Acupuncture & Moxibustion 2025;45(3):345-350
OBJECTIVE:
To observe the effects of electroacupuncture at the pterygopalatine region on nucleotide-binding oligomerization domain-like receptor protein 3 (NLRP3)-mediated pyroptosis and inflammatory factors in rats with allergic rhinitis (AR).
METHODS:
Twenty-four SD rats were randomly divided into a blank group, a model group, an acupuncture group and an electroacupuncture group, 6 rats in each group. Except for the blank group, OVA-induced AR model was established in the remaining groups. In the electroacupuncture group, the rats were treated with electroacupuncture at the bilateral pterygopalatine region, with disperse-dense wave, in frequency of 2 Hz/100 Hz and current of 0.5-1 mA, 15 min each time, once every other day, for 3 times. In the acupuncture group, the rats were treated with acupuncture at bilateral pterygopalatine region simply, without electrical stimulation. The rhinitis symptom score was observed, the pathomorphology of the nasal mucosa was observed by HE staining; the serum levels of OVA-specific immunoglobulin E (OVA-sIgE), interleukin (IL)-4, IL-6 and IL-1β were detected by ELISA; the mRNA expression of NLRP3, apoptosis-associated speck-like protein containing CARD (ASC), cysteinyl aspartate specific proteinase-1 (caspase-1) and IL-18 in the nasal mucosa was detected by real-time PCR; the protein expression of NLRP3, ASC, caspase-1 and IL-18 in the nasal mucosa was detected by Western blot.
RESULTS:
Compared with the blank group, in the model group, the rhinitis symptom score was increased (P<0.01), the serum levels of OVA-sIgE, IL-4, IL-6 and IL-1β were increased (P<0.05), the nasal mucosa showed pathomorphology of inflammatory infiltration; the mRNA and protein expression of NLRP3, ASC, caspase-1 and IL-18 in the nasal mucosa was increased (P<0.05). Compared with the model group, in the electroacupuncture group, the rhinitis symptom score was reduced (P<0.01), the pathology of the nasal mucosa was improved; the serum levels of OVA-sIgE, IL-4, IL-6 and IL-1β were decreased (P<0.05); the mRNA and protein expression of NLRP3, ASC, caspase-1 and IL-18 in the nasal mucosa was decreased (P<0.05).
CONCLUSION
Electroacupuncture at the pterygopalatine region can exerting the anti-inflammatory effect by inhibiting NLRP3-mediated pyroptosis and inflammatory factor imbalance, thus alleviate rhinitis symptoms in AR rats.
Animals
;
Electroacupuncture
;
NLR Family, Pyrin Domain-Containing 3 Protein/immunology*
;
Rats
;
Rats, Sprague-Dawley
;
Rhinitis, Allergic/physiopathology*
;
Pyroptosis
;
Male
;
Acupuncture Points
;
Humans
;
Female
;
Interleukin-1beta/genetics*
;
Interleukin-18/immunology*
;
Interleukin-6/genetics*
;
Caspase 1/immunology*
2.Affective responses during interval training in obese adolescents:A randomized controlled trial
Meng CAO ; Fengyuan YU ; Yu ZOU ; Yucheng TANG
Chinese Journal of Sports Medicine 2024;43(7):527-536
Objective To explore the affective response and dynamic attributes of obese adolescents in high-and moderate-intensity interval training.Methods Between February and July 2023,a total of 42 obese adolescents(Age:12.3±0.5 years,BMI:24.0±1.1 kg/m2)were recruited and randomly divided into a high-intensity interval training group(HIIT),a moderate-intensity interval training group(MIIT),and a non-training control group.Before and after the intervention,all groups were measured and compared their weight,BMI,body composition(body fat percentage and visceral adipose fat),car-diorespiratory fitness(VO2max),and affective response during exercise(affect valence,perceived arousal,rating of perceived exertion),as well as post-exercise enjoyment.Results After the 12-week interven-tion,there were significant decrease in the average BMI,body fat percentage,and visceral adipose tis-sue in the HIIT group(P<0.05),but a significant increase in the average VO2max(P<0.05).Moreover,a-fter the training,the average VO2max of the HIIT group was significantly higher than the MIIT group(P<0.05).Meanwhile,both HIIT and MIIT had a positive effect on emotional valence and post-exercise enjoyment.However,MIIT participants had more positive affect responses than HIIT ones,while the arousal(P<0.01)and physical activity enjoyment scores(P<0.05)in the HIIT group were significantly higher than the MIIT group.Conclusions Interval training is effective in improving body composition and cardiorespiratory fitness of obese adolescents.Higher intensity and arousal are key to the improve-ment.Moreover,the positive affect response and exercise enjoyment after interval training may help them maintain high exercise adherence and play a long-term promoting role.
3.Prognostic factors of liver transplantation for hepatocellular carcinoma recipients beyond UCSF criteria but without macrovascular invasion
Guangdong WU ; Rui TANG ; Ang LI ; Xuan TONG ; Lihan YU ; Yucheng HOU ; Abudusalamu AINI ; Wei YANG ; Huayuan HAO ; Jingyi LIN ; Qian LU
Chinese Journal of General Surgery 2024;39(5):339-343
Objective:To investigate the prognostic factors for liver transplantation for hepatocellular carcinoma beyond UCSF criteria but without macrovascular invasion.Methods:A retrospective analysis was performed for the clinical data of the hepatocellular carcinoma patients without macrovascular invasion beyond UCSF criteria who underwent liver transplantation at our center from Jan 2018 to Jun 2023. The receiver operating characteristic curve analysis was performed to assess the predictive power of potential prognosis factors.Results:With this criteria, the 1-, 3-year overall survival rates were 94.1% and 75.0%, respectively, and the 1-, 3-year tumor free survival rates were 82.4% and 38.1%, respectively. The maximum tumor size, number of tumors, AFP, PIVKA-Ⅱ before transplantation, and whether undergo pretransplant down-stage therapy were significant prognostic factors ( P<0.05). Combining the above prognostic factors to construct the receiver operating characteristic curve yielded an area under the curve of 0.967, with a sensitivity and specificity of 0.932, 0.952, respectively. Further, the differentiation, MVI and Ki-67 were significant prognostic factors ( P<0.05). Combining pathological factors to construct the receiver operating characteristic curve yielded an area under the curve of 0.927, with a sensitivity and specificity of 0.769, 1, respectively. Conclusion:The maximum tumor diameter, number of tumors, AFP, PIVKA-Ⅱ before transplantation, and pretransplant down-stage therapy and tumor differentiation, MVI and Ki-67 are all prognostic factors of liver transplantation for hepatocellular carcinoma without macrovascular invasion beyond UCSF criteria.
4.Application value of the anatomically oriented "six steps with six windows" approach in laparoscopic radical total gastrectomy
Yucheng SONG ; Chuang LI ; Ke CHEN ; Wenjing GENG ; Ruixue TANG ; Guangtan ZHANG
Chinese Journal of Digestive Surgery 2023;22(8):1021-1027
Objective:To investigate the application value of the anatomically oriented "six steps with six windows" approach in laparoscopic radical total gastrectomy.Methods:The retros-pective cohort study was conducted. The clinicopathological data of 121 patients who underwent laparoscopic radical total gastrectomy in Henan Provincial People′s Hospital from January 2019 to February 2022 were collected. There were 53 males and 68 females, aged (68±12)years. Of the 121 patients, 72 patients using the traditional approach in the surgery were divided into the control group, and 49 patients using the "six steps with six windows" approach in the surgery were divided into the experiment group. Observation indicators: (1) surgical situations; (2) postoperative situations. Measurement data with normal distribution were represented as Mean± SD, and comparison between groups was conducted using the t test. Count data were described as absolute numbers or percen-tages, and comparison between groups was conducted using the chi-square test. Results:(1) Surgical situations. All 121 patients underwent laparoscopic radical total gastrectomy successfully, without laparotomy conversion. The operation time, volume of intraoperative blood loss, number of lymph nodes dissected were (250±50)minutes, (150±34)mL, 41±6 in the control group, versus (180±16)minutes, (55±13)mL, 51±5 in the experiment group, showing significant differences in the above indicators between the two groups ( t=11.04, 21.47, 9.42, P<0.05). (2) Postoperative situations. The times of postoperative analgesic injection, time to postoperative ?rst ?atus, duration of postoperative hospital stay, postoperative pathological staging (stage Ⅰ, stage Ⅱ, stage Ⅲ), incidence of postoperative complication were 3.4±1.6, (4.0±1.4)days, (13.1±2.0)days, 9, 32, 31, 15.3%(11/72) in the control group, versus 3.5±1.7, (4.1±1.5)days, (13.1±1.7)days, 6, 25, 18, 16.3%(8/49), showing no significant difference in the above indicators between the two groups ( t=0.35, 0.18, 0.03, Z=0.55, χ2=0.02, P>0.05). There was no perioperative death in both groups of patients. Conclusion:Appli-cation of the anatomically oriented "six steps with six windows" approach in laparoscopic radical total gastrectomy is safe and feasible.
5.Portal vein aneurysm after liver transplantation: report of two cases and literature review
Hongqiang ZHAO ; Cao’er DONG ; Yucheng HOU ; Guangdong WU ; Xuan TONG ; Ang LI ; Lihan YU ; Qian LU ; Guangxun XU ; Hong CHEN ; Rui TANG
Organ Transplantation 2023;14(5):708-713
Objective To summarize the diagnosis and treatment experience of portal vein aneurysm after liver transplantation. Methods Clinical data of two recipients with portal vein aneurysm after liver transplantation were retrospectively analyzed. Clinical features, diagnosis, treatment and prognosis were summarized based on literature review. Results Both two cases were diagnosed with intrahepatic portal vein aneurysm complicated with portal vein thrombosis and portal hypertension after liver transplantation. Case 1 was given with targeted conservative treatment and he refused to undergo liver retransplantation. Physical condition was worsened after discharge, and the patient eventually died from liver graft failure, kidney failure, lung infection, and septic shock. Case 2 received high-dose glucocorticoid pulse therapy, whereas liver function was not improved, and the patient was recovered successfully after secondary liver transplantation. Conclusions Long-term complication of portal vein aneurysm (especially intrahepatic type) after liver transplantation probably indicates poor prognosis. Correct understanding, intimate follow-up and active treatment should be conducted. Liver retransplantation may be a potential treatment regimen.
6.Value of low-energy virtual monochromatic images of dual-energy CT in the evaluation of tumor visibility and T staging in hypopharyngeal squamous cell carcinoma
Rujian HONG ; Yucheng PAN ; Peng WANG ; Zuohua TANG
Chinese Journal of Radiology 2023;57(2):136-141
Objective:To investigate the value of low-energy virtual monoenergetic image (VMI) at 45 keV in visualizing the primary tumor and T staging of hypopharyngeal squamous cell carcinoma.Methods:The clinical and imaging data of 58 patients with hypopharyngeal squamous cell carcinoma from April 2018 to January 2020 at Eye & ENT Hospital, Fudan University were analyzed retrospectively. All the patients underwent a venous phase contrast-enhanced dual-source dual-energy CT scan before treatment. The VMI at 45 keV and standard linearly blended image (30% 80 kV+70% 140 kV) were acquired from dual-energy post-processing software. One senior radiologist and one junior radiologist independently assessed the visibility of the tumor on the 45 keV VMI and standard linearly blended image using a 5-point Likert rating scale. Furthermore, the senior radiologist assessed the visibility of the tumor at each subsite (piriform fossa, posterior pharyngeal wall, postcricoid region) and determined the invasion depth of the tumor (extension to esophagus, invasion to strip muscles and prevertebral muscles) and performed the T staging of the primary tumor using the two sets of images blindly. The accuracy of T staging was calculated, using pathological T staging (surgical cases) or clinical T staging (non-surgical cases) as the gold standard. The image scores of the two sets of images were compared using Wilcoxon rank sum test. McNemar-Bowker test was used to compare the accuracy of T staging using the two sets of images.Results:The overall image scores of the 45 keV VMI and standard linearly blended image from the senior radiologist were 3.5 (3, 4) and 3 (2, 3) respectively ( Z=-7.03, P<0.001), and the scores from the junior radiologist were 3 (3, 4) and 2 (2, 3) ( Z=-6.93, P<0.001). The scores of the 45 keV VMI were significantly higher than those of the standard linearly blended image in visualizing tumors in the piriform fossa, posterior pharyngeal wall, and postcricoid region, as well as in detecting invasion to the strip muscles ( P<0.05). There was no significant difference in the scores of the two sets of images in determining whether the tumor extended to esophagus or invaded prevertebral muscles ( P>0.05). Referring to pathological and clinical T stage, the accuracy of T staging determined by the 45 keV VMI and standard linearly blended image was 87.9% (51/58) and 81.0% (47/58) respectively, and the difference was not significant (χ 2=3.33, P=0.189). Conclusions:The 45 keV VMI is superior to the standard linearly blended image in visualizing tumors and detecting invasion to the strip muscles of hypopharynx squamous cell carcinoma. However, the accuracy of determining T staging using 45 keV VMI is slightly improved than that of standard linearly blended image, and the difference is not statistically significant. In determining whether the tumor extends to esophagus or invades prevertebral muscles, 45 keV VMI shows no significant advantage over standard linearly blended image.
7.Research advances in immune checkpoint inhibitor-related cholangitis
Yucheng HOU ; Hongqiang ZHAO ; Caoer DONG ; Guangdong WU ; Xuan TONG ; Ang LI ; Qian LU ; Hong CHEN ; Rui TANG
Journal of Clinical Hepatology 2023;39(2):463-468
Immune checkpoint inhibitors (ICIs) have ushered in a new era of tumor treatment; however, immunotherapy-related adverse events are critical issues that restrict the clinical application of ICIs and have attracted wide attention. The liver is one of the target organs that is easily affected. With the progress in research, scholars have found that besides hepatocytes, intrahepatic and extrahepatic bile ducts can also be attacked by the immune system, leading to the disease known as immune-related cholangitis. This article reviews the research advances in ICI-related cholangitis by summarizing related articles, in order to preliminarily reveal its clinical, pathological, and imaging features and provide clues for early identification, standard treatment, and subsequent research.
8.Feasibility of Free-Breathing, Non-ECG-Gated, Black-Blood Cine Magnetic Resonance Images With Multitasking in Measuring Left Ventricular Function Indices
Pengfei PENG ; Xun YUE ; Lu TANG ; Xi WU ; Qiao DENG ; Tao WU ; Lei CAI ; Qi LIU ; Jian XU ; Xiaoqi HUANG ; Yucheng CHEN ; Kaiyue DIAO ; Jiayu SUN
Korean Journal of Radiology 2023;24(12):1221-1231
Objective:
To clinically validate the feasibility and accuracy of cine images acquired through the multitasking method, with no electrocardiogram gating and free-breathing, in measuring left ventricular (LV) function indices by comparing them with those acquired through the balanced steady-state free precession (bSSFP) method, with multiple breath-holds and electrocardiogram gating.
Materials and Methods:
Forty-three healthy volunteers (female:male, 30:13; mean age, 23.1 ± 2.3 years) and 36 patients requiring an assessment of LV function for various clinical indications (female:male, 22:14; 57.8 ± 11.3 years) were enrolled in this prospective study. Each participant underwent cardiac magnetic resonance imaging (MRI) using the multiple breath-hold bSSFP method and free-breathing multitasking method. LV function parameters were measured for both MRI methods. Image quality was assessed through subjective image quality scores (1 to 5) and calculation of the contrast-to-noise ratio (CNR) between the myocardium and blood pool. Differences between the two MRI methods were analyzed using the Bland–Altman plot, paired t-test, or Wilcoxon signed-rank test, as appropriate.
Results:
LV ejection fraction (LVEF) was not significantly different between the two MRI methods (P = 0.222 in healthy volunteers and P = 0.343 in patients). LV end-diastolic mass was slightly overestimated with multitasking in both healthy volunteers (multitasking vs. bSSFP, 60.5 ± 10.7 g vs. 58.0 ± 10.4 g, respectively; P < 0.001) and patients (69.4 ± 18.1 g vs. 66.8 ± 18.0 g, respectively; P = 0.003). Acceptable and comparable image quality was achieved for both MRI methods (multitasking vs. bSSFP, 4.5 ± 0.7 vs. 4.6 ± 0.6, respectively; P = 0.203). The CNR between the myocardium and blood pool showed no significant differences between the two MRI methods (18.89 ± 6.65 vs. 18.19 ± 5.83, respectively; P = 0.480).
Conclusion
Multitasking-derived cine images obtained without electrocardiogram gating and breath-holding achieved similar image quality and accurate quantification of LVEF in healthy volunteers and patients.
9.Scan time and accuracy of full-arch scans with intraoral scanners: a comparative study on conditions of the intraoral head-simulator and the hand-held model
Mingtong WU ; Suxia TANG ; Lingyan PENG ; Yuting HAN ; Yucheng SU ; Xia WANG
Chinese Journal of Stomatology 2021;56(6):570-575
Objective:To comparatively evaluate the scan time and the accuracy of maxillary full-arch scans using four intraoral scanners (IOS) on conditions of the intraoral head-simulator and the hand-held model, and to evaluate the influence of different scanning conditions on digital scan.Methods:A upper dental arch model with melamine-formaldehyde resin teeth and silica gel gingiva that could be fixed on a head simulator was scanned with an optical scanner (ATOS Core) in order to obtain the standard tessellation language dataset as reference. Intraoral scans were performed on the model fixed on the head simulator by three researchers with four IOS [A: TRIOS 3; B: CS 3600; C: CEREC Omnicam; D: iTero]. For each scanner and each researcher, six scans were performed, to obtain the datasets as the head simulator group. And another six scans with each of the four intraoral scanners were performed by each researcher on the hand-held model to obtain the STL datasets as the hand-held group. The scan time were recorded for each scan. In the Geomagic Wrap software, the digital models were trimmed with only the teeth information retained and supreimposed by best fit alignment function and compared to obtain the root mean square (RMS) values of the discrepancies by three-dimensional compare function. The test datasets of each group were compared with the reference dataset for trueness. The six test scanning datasets with the same scanner of the same researcher were cross compared for precision. Mann Whitney U test was used to statistically analyze the difference values of the scan time, trueness and precision of the same intraoral scanner between head simulator group and hand-held group. Results:Compared to the hand-held group, the scan time of A [142(82) s] and D [119(52) s], which two IOS both with handle, were longer in head simulator group [A: 98(28) s; D: 85(22) s] ( P<0.01). However there were no significant differences between the two groups for scan time of IOS B and C ( P>0.05). For full-arch scan accuracy (trueness and precision), there were no significant differences between the two groups of IOS A and B ( P>0.05), while the trueness of C ( P<0.05) and the precision of D ( P<0.01) were better in head simulator group [C: 112(38) μm; D: 43(13) μm] compared to hand-held group [C: 135(47) μm; D: 53(18) μm]. However, there were no significant differences for the precision of C ( P>0.05) and the trueness of D ( P>0.05). Conclusions:The scan time and the accuracy of full-arch digital scans with different IOS may be effected by the scan conditions. For in vitro study of intraoral scanning, head-simulator can simulate the intraoral environment of the real patient to some extent. Meanwhile, the position of the dentist and the patient, and also the limited intraoral space during intraoral scanning are also simulated.
10.Effect of digital intraoral full-arch scan strategies on scan time and accuracy on conditions of intraoral head-simulator
Mingtong WU ; Suxia TANG ; Lingyan PENG ; Deping CHEN ; Yucheng SU ; Xia WANG
Chinese Journal of Stomatology 2021;56(11):1092-1097
Objective:To comparatively evaluate the accuracy and the scan time of three full-arch scan strategies on the head-simulator, to explore a full-arch scan strategy with better clinical operability and high accuracy.Methods:A cross-controlled study design was used. A model with melamine-formaldehyde resin teeth and silica gel gingiva of an upper dental arch which can be fixed on a head simulator was scanned with an optical scanner (ATOS Core) in order to obtain the standard tessellation language (STL) dataset as reference. Intraoral scans were performed on the model fixed on the head simulator with four intraoral scanners (IOS) [A (TRIOS 3), B (CS 3600), C (CEREC Omnicam), D (iTero)]. The STL datasets were obtained from each of the four different IOS systems by using three scan strategies (scan strategies 1, 2 and 3 were composed of 10, 5 and 7 paths respectively) all by one attending doctor with 3 years of intraoral scanning experience. For each scanner and each scan strategy, nine scans were acquired. And the scan time was recorded for each scan. Following the scan strategy, the scan path was completed to obtain a full-arch digital model, and the scan time was recorded as full-arch scan time. Complementary scans were performed to fill the missing image, and this scan time was recorded as complementary scan time. The total scan time was obtained by adding full-arch scan time and complementary scan time. Through the Geomagic Wrap software, the three-dimensional (3D) models were overlaid by best fit alignment function and compared to obtain the root mean square values of the discrepancies by 3D compare function. The intraoral scanning datasets were compared with the reference for trueness. The nine intraoral scanning datasets were cross compared with same scan strategy and same intraoral scanner for precision.Results:There were no significant differences among the three scan strategies for trueness ( P>0.05), while the differences among the three scan strategies for precision were affected by difference IOSs ( P<0.05), and only scan strategy 3 showed the highest precision with all the four IOS. The full-arch scan time of scan strategies 1, 2 and 3 were (130±24), (72±17) and (90±19) s respectively ( P<0.05). For complementary scan time, scan strategy 2 [(50±24) s] took longer time than scan strategy 1 [(26±18) s] and scan strategy [(25±21) s] ( P<0.05), while no significant differences between the latter two ( P>0.05). For total scan time, scan strategy 1 [(156±31) s] took longer time than scan strategy 2 [(122±30) s ] and scan strategy 3 [(115±29) s ] ( P<0.05), while no significant differences between the latter two ( P>0.05). Conclusions:Full-arch scanning on the head-simulator with scan strategy 3 which can obtain scanning datasets with high accuracy, was more convenient to operate and took shorter scan time, and is generally suitable for intraoral scanners commonly used in clinic.

Result Analysis
Print
Save
E-mail