1.Establishment of a risk assessment model based early warning system for infectious diseases
Yonghua LU ; Yifang LI ; Fang HUANG ; Wenying HE
Modern Hospital 2024;24(1):111-113
Objective To establish a risk assessment model based infectious disease early warning system and promote the improvement of infectious disease management level.Methods By collecting and organizing the latest research results,and referring to the theoretical framework of the relevant infectious disease early warning evaluation index system,a risk assessment model based infectious disease early warning system is constructed.Results A total of 12 experts were included in this study,and three primary indicators were selected,including pre-epidemic indicators,typical symptom period indicators,atypical symp-tom period indicators,and 7 secondary indicators.The average score for necessity of the system was 8.27±0.24 points,and the average score for accessibility was 7.74±0.34 points.Conclusion The establishment of an infectious disease early warning sys-tem based on risk assessment models is conducive to timely following the epidemic trend of infectious diseases in the local area,analyzing the distribution trend of survey indicators,and proposing corresponding early warning plans,which can provide relevant basis for effective prevention of infectious diseases.
2.Prevalence of work-related musculoskeletal disorders among vegetable greenhouse workers
LÜ ; He ; CHANG Rui ; YANG Huilian ; GUO Yinghua ; XING Yonghua
Journal of Preventive Medicine 2024;36(2):97-100
Objective:
To investigate the prevalence of work-related musculoskeletal disorders (WMSDs) and influencing factors among vegetable greenhouse workers, so as to provide insights into relevant intervention measurements.
Methods:
Workers from 4 vegetable greenhouse villages were sampled in the suburbs of Xining City using a cluster sampling method from March to April 2023. Participants' demographic information, characteristics of greenhouse operation and prevalence of WMSDs were collected using questionnaire surveys. Factors affecting the prevalence of WMSDs among vegetable greenhouse workers were identified using a multivariable logistic regression model.
Results:
A total of 550 questionnaires were distributed, and 518 valid questionnaires were recovered, with an effective response rate of 94.18%. There were 264 males (50.97%) and 254 females (49.03%), and 269 participants (51.93%) aged 50 years and older. The prevalence of WMSDs among vegetable greenhouse workers was 40.93% (212 cases). Waist, neck and back were mainly affected, with 185 (35.71%), 157 (30.31%), and 153 (29.54%) cases, respectively. Multivariable logistic regression analysis showed that workers who smoke (OR=2.406, 95%CI: 1.133-5.110), worked 8 hours and longer per day (OR=6.618, 95%CI: 3.492-12.542) and lift heavy loads of about 20 kg (OR=1.770, 95%CI: 1.013-3.092) had a higher risk of WMSDs.
Conclusions
WMSDs occurred in 40.93% of vegetable greenhouse workers in Xining City, and waist, neck and back were mainly affected. Smoking, working duration and lifting heavy loads may influence the prevalence of WMSDs among vegetable greenhouse workers in Xining City.
3.Analysis of clinical phenotype and genotype of PAX2 mutation in Chinese children
Xueqing MA ; Yonghua HE ; Jing YANG ; Rongrong XU ; Siying YANG ; Wenpei LIANG ; Jianhua ZHOU ; Huiqing YUAN ; Liru QIU
Chinese Journal of Nephrology 2024;40(1):24-35
Objective:To analyze and summarize the clinical, genotypic and pathological characteristics of children with PAX2 gene mutation in China, and to provide information for the monitoring, treatment and prognosis of the disease. Methods:It was a case series analysis study. The clinical data of children with PAX2 gene mutation in Pediatric Nephrology Department, Tongji Hospital Affiliated to Tongji Medical College, Huazhong University of Science and Technology from January 2014 to December 2022 were collected, and peripheral blood gene DNA was extracted and sequenced for whole exome sequencing. The clinical, pathological and genotypic characteristics of PAX2 gene variation of children in China were summarized by searching PubMed, Medline, China National Knowledge Infrastructure and Wanfang database and compared with the cases in this single center. Results:Among the 13 children with PAX2 gene mutation, there were 9 males and 4 females, 12 patients with abnormal urine tests, 7 patients with small kidney volume by imaging examination, and 5 patients with renal cysts. The clinical phenotypes were congenital renal and urinary tract malformations in 8 cases, renal coloboma syndrome in 1 case, and hematuria or proteinuria in 3 cases. Five patients underwent renal biopsies, showing focal segmental glomerulosclerosis and C3 glomerulopathy in 1 case, focal segmental glomerulosclerosis in 1 case, thin basement membrane lesion in 1 case, and IgA nephropathy in 2 cases. The genetic testing in 13 children showed 9 de novo mutations and 4 new mutations of c.321G>A, c.213-8C>G, c.63C>A and c.449C>T. There were 2 cases of 76dupG (p.V26Gfs*28) mutant. A total of 51 Chinese children with PAX2 gene mutation were found in the literature search. There were 32 males and 19 females, 8 cases with small kidney volume and 12 cases with renal cysts. The clinical phenotypes were congenital anomalies of kidney and urinary tract in 28 cases, renal coloboma syndrome in 17 cases, and hematuria or proteinuria in 6 cases. Seven patients underwent renal biopsies, including 2 cases with focal segmental glomerulosclerosis, 1 case with minimal lesion, 1 case with mesangial proliferative glomerulonephritis, 1 case with IgA nephropathy, 1 case with membranous nephropathy and a case with focal proliferative sclerosing purpura nephritis combined with glomerular hypertrophy. Thirty-four cases were de novo mutations, and 12 mutations were from the father or mother. The father or mother of 5 children had no clinical manifestations, with normal renal function. There were 11 cases of 76dupG (p.V26Gfs*28) mutant. Conclusions:The clinical phenotypes and genotypes of PAX2 gene variation in Chinese children are diverse. The most common clinical phenotype of PAX2 gene variation is congenital anomalies of kidney and urinary tract. c.76dupG (p.V26Gfs*28) is the most common of PAX2 gene variant.
4.Prognosis and risk factors of IgA vasculitis nephritis in children
Xueqing MA ; Yonghua HE ; Jinyun PU ; Wenpei LIANG ; Panpan SHAO ; Jianhua ZHOU ; Yu ZHANG ; Jinhui TANG ; Tonglin LIU ; Huiqing YUAN ; Liru QIU
Chinese Journal of Pediatrics 2024;62(12):1184-1190
Objective:To investigate the prognosis and risk factors of IgA vasculitis nephritis (IgAVN) in children.Methods:A retrospective cohort study was conducted. Clinical data were collected from 264 children who were pathologically diagnosed with IgAVN at Department of Pediatric Nephrology, Tongji Hospital, affiliated with Tongji Medical College, Huazhong University of Science and Technology, between January 2011 and December 2017. All patients had a follow-up period of more than 3 years. Clinical characteristics, renal pathology, 3-year and 5-year prognosis were analyzed. The patients were grouped based on gender, age of onset (≤6 years, >6-9 years, and >9 years), pathological classification (≤Ⅲ and>Ⅲ),whether the prognosis was complete remission at 3 and 5 years. Independent sample t-tests, ANOVA or chi-squared test were used for intergroup comparisons. Spearman correlation analysis was applied for ordinal data, and multivariate Logistic regression was used to analyze factors affecting the prognosis. Receiver operating characteristic (ROC) curve was utilized to evaluate the predictive value of these factors. Results:Of the 264 children with IgAVN, 153 were male and 111 were female, the age of onset was 8.3 (6.7, 10.3) years, 118 patients (45%) with onset age >6-9 years accounted for the highest proportion. All patients presented with skin purpura and renal involvement, primarily manifesting as hematuria and/or proteinuria. Microscopic hematuria was observed in 253 patients (95.8%), while 246 patients (93.2%) showed proteinuria. In 256 patients (97.0%), hematuria or proteinuria urinalysis was detected within 6 months of skin purpura onset, and 243 patients (92.0%) underwent renal biopsy within 6 months of renal involvement. The most common clinical subtype in 264 IgAVN children was hematuria and proteinuria (204 cases, 77.3%), with grade Ⅲ being the predominant pathological classification (181 cases, 68.6%). Among children ≤6 years old, the 3-year complete remission rate was higher in males than in females (83.9% (26/31) vs. 7/16, χ2=8.12, P=0.012). Factors independently associated with poor 5-year prognosis included time from hematuria or proteinuria urinalysis to renal biopsy >6 months, elevated serum cholesterol levels, and incomplete remission 3 years post-biopsy ( OR=5.41, 1.39, 6.02, 95% CI 1.40-20.86, 1.04-1.84, 2.61-13.88, all P<0.05). The serum cholesterol has a predictive value for 5-year prognosis ( P=0.020, AUC=0.62, 95% CI 0.52-0.71, Youden index=0.27, cutoff=4.37). Conclusions:For children with IgAVN aged≤6 years, the 3-year prognosis is better in males than in females. Time from hematuria or proteinuria urinalysis to renal biopsy >6 months, elevated serum cholesterol levels, and incomplete remission at 3 years post-biopsy may be independent risk factors for poor 5-year prognosis in children with IgAVN.
5.Exploratory study on noninvasive evaluation of renal histopathology by ultrasonic shear wave elastography
Jinyun PU ; Lei YE ; Yonghua HE ; Rongrong XU ; Siying YANG ; Huiqing YUAN ; Siyuan LIU ; Wenpei LIANG ; Liru QIU
Chinese Journal of Nephrology 2023;39(8):587-594
Objective:To determine a relationship between ultrasound shear wave elastography (SWE) and pathological lessions of renal tissues in children with chronic kidney disease (CKD).Methods:It was a cross-sectional observational study, involving children admitted to the Department of Pediatrics of Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology from January to December 2021 with definite pathological diagnosis through kidney biopsy. The SWE was used to determine the Young's modulus (elastic modulus) of the cortex and medulla of the upper, middle, and lower poles of the kidney. The renal histopathology was classified or graded. The statistical method was used to analyze the relationship between Young's modulus of the inferior polar cortex (YM cor) and medulla (YM med) of the right kidney and renal pathology. Results:The study included 110 children with definite pathological diagnosis through renal biopsy, aged (10.1±3.4) years old (2-17 years old), with 55 males (50.0%). The body mass index was (20.6±2.4) kg/m 2, and mean arterial pressure was (95±24) mmHg. There were 94 patients (85.4%) with CKD stage 1, 8 patients (7.3%) with CKD stage 2, and 8 patients (7.3%) with CKD stage 3. There was no significant difference of YM cor and YM med in the upper and middle poles of the right kidneys, and YM med in the lower poles of right kidneys in CKD patients with different stages (all P>0.05). Both YM cor [(15.75±3.36) kPa] and YM med [(13.50±2.43) kPa] of CKD stage 3 patients were significantly higher than those of CKD stage 1 patients [(12.94±2.45) kPa, (11.88±2.23) kPa](both P<0.05). There was no significant difference of YM cor and YM med in the lower poles of right kidneys between stage 1 and stage 2 CKD patients (both P>0.05). YM cor[(17.93±3.23) kPa] and YM med [(15.50±1.48) kPa] in patients with crescentic glomerulonephritis were higher than those in patients with focal segmental glomerulosclerosis [(12.71±2.42) kPa, (11.57±2.63) kPa] and mesangial proliferative glomerulonephritis [(12.73±2.04) kPa, (11.48±2.10) kPa](all P<0.05). There was no significant difference of YM cor and YM med between focal segmental glomerulosclerosis and mesangial proliferative glomerulonephritis (both P>0.05). YM cor [(16.30±2.63) kPa] and YM med [(15.54±1.59) kPa] of Lee's Ⅳ grade of IgA nephropathy were higher than those of Lee's Ⅲ grade [(13.32±2.70) kPa, (12.57±2.50) kPa](both P<0.05), while the International Study of Kidney Disease in Children grade of purpura nephritis had no significant correlation with YM cor and YM med (both P>0.05). YM cor [(15.41±2.37) kPa] and YM med [(13.82±2.59) kPa] of interstitial fibrosis/tubular atrophy (T1/T2) group of IgA nephropathy mixed with purpura nephritis were significantly higher than those of T0 group's [(12.99±2.40) kPa, (11.79±2.05) kPa] (both P<0.05). Moreover, crescent formation (C1) group had a higher YM cor [(14.21±2.77) kPa] and YM med [(12.80±2.47) kPa] than those in C0 group [(12.73±2.15) kPa, (11.59±1.97) kPa] (both P<0.05), while YM cor and YM med were unrelated to the mesangial hypercellularity (M), endocapillary cellularity (E), segmental sclerosis or adhesion (S) indicators (all P>0.05). In lupus nephritis patients, YM cor ( r=0.744, P=0.035) and YM med ( r=0.728, P=0.009) were favorably linked with the chronic index, but not with the activity index (both P>0.05). Conclusions:Renal interstitial fibrosis/tubular atrophy and crescentic development are connected with YM cor and YM med at the lower pole of the kidney as measured by SWE. SWE can be used to assess the chronic renal lesions in children with CKD in the early and middle stages. It may develop into a new noninvasive way to assess renal pathology.
6.Chromatin conformation of human oral epithelium can identify orofacial cleft missing functional variants.
Yao XIAO ; Shengbo JIAO ; Miao HE ; Da LIN ; Huanyan ZUO ; Jiahao HAN ; Yonghua SUN ; Gang CAO ; Zhi CHEN ; Huan LIU
International Journal of Oral Science 2022;14(1):43-43
Genome-wide association studies (GWASs) are the most widely used method to identify genetic risk loci associated with orofacial clefts (OFC). However, despite the increasing size of cohort, GWASs are still insufficient to detect all the heritability, suggesting there are more associations under the current stringent statistical threshold. In this study, we obtained an integrated epigenomic dataset based on the chromatin conformation of a human oral epithelial cell line (HIOEC) using RNA-seq, ATAC-seq, H3K27ac ChIP-seq, and DLO Hi-C. Presumably, this epigenomic dataset could reveal the missing functional variants located in the oral epithelial cell active enhancers/promoters along with their risk target genes, despite relatively less-stringent statistical association with OFC. Taken a non-syndromic cleft palate only (NSCPO) GWAS data of the Chinese Han population as an example, 3664 SNPs that cannot reach the strict significance threshold were subjected to this functional identification pipeline. In total, 254 potential risk SNPs residing in active cis-regulatory elements interacting with 1 718 promoters of oral epithelium-expressed genes were screened. Gapped k-mer machine learning based on enhancers interacting with epithelium-expressed genes along with in vivo and in vitro reporter assays were employed as functional validation. Among all the potential SNPs, we chose and confirmed that the risk alleles of rs560789 and rs174570 reduced the epithelial-specific enhancer activity by preventing the binding of transcription factors related to epithelial development. In summary, we established chromatin conformation datasets of human oral epithelial cells and provided a framework for testing and understanding how regulatory variants impart risk for clefts.
Chromatin
;
Cleft Lip/genetics*
;
Cleft Palate/genetics*
;
Epithelium
;
Genome-Wide Association Study
;
Humans
7.Family-based association tests for rare variants.
Xi CHEN ; Si Yue WANG ; En Ci XUE ; Xue Heng WANG ; He Xiang PENG ; Meng FAN ; Meng Ying WANG ; Yi Qun WU ; Xue Ying QIN ; Jin LI ; Tao WU ; Hong Ping ZHU ; Jing LI ; Zhi Bo ZHOU ; Da Fang CHEN ; Yonghua HU
Chinese Journal of Epidemiology 2022;43(9):1497-1502
Next-generation sequencing has revolutionized family-based association tests for rare variants. As the lower power of genome wide association study for detecting casual rare variants, methods aggregating effects of multiple variants have been proposed, such as burden tests and variance component tests. This paper summarizes the methods of rare variants association test that can be applied for family data, introduces their principles, characteristics and applicable conditions and discusses the shortcomings and the improvement of the present methods.
Computer Simulation
;
Family Relations
;
Genetic Association Studies
;
Genetic Variation
;
Genome-Wide Association Study/methods*
;
Humans
8.SARS-CoV-2 reactive memory T cell immunity in healthy individuals
Chen LUO ; Yonghua YIN ; Yudi XIE ; Zhihang HE ; Ling LI ; Zhong LIU ; Jue WANG ; Qiang CHEN
Chinese Journal of Blood Transfusion 2022;35(5):504-508
【Objective】 To understand the memory phenotype and function of SARS-CoV-2 reactive CD4+ T cells in healthy individuals. 【Methods】 In this study, SARS-CoV-2-derived peptides were used to stimulate PBMC from participants.SARS-CoV-2 reactive memory T cells were detected by intracellular staining and flow cytometry, and memory phenotype analysis was performed.CBA was used to detect cytokine secretion after SARS-CoV-2-derived peptides stimulation to evaluate the function of SARS-CoV-2 reactive memory T cells. 【Results】 We found that SARS-CoV-2 reactive CD4+ memory T cells could be detected in 40% (6/15) healthy donors.Phenotypic analysis of memory showed that these T cells were mainly composed of central memory T cells(82.2%), and other memory cells accounted for 17.8%.Compared with negative control, IL-10 was significantly decreased after stimulation of SARS-CoV-2-derived peptides (P<0.05), while the secretion of IFNγ, TNFα, IL-2 and IL-4 showed no significant difference. 【Conclusions】 SARS-CoV-2 reactive CD4+ memory T cells are present in healthy individuals from China.
9.Clinical study of digital six-axis external fixation frame based on CT data for tibiofibular fractures
Bin JIA ; Chen FEI ; Jing REN ; Min WANG ; Jinlong HE ; Zhaochen XU ; Yufeng LU ; Liang QI ; Yonghua LIAO ; Feng QIAO
Chinese Journal of Surgery 2022;60(6):552-557
Objective:To investigate the clinical effect of applying the digital six-axis external fixation frame based on CT data in the treatment of tibiofibular fractures.Methods:The clinical data of 43 patients with tibiofibular fractures treated by the self-developed digital six-axis external fixation frame based on CT data at Integrated Orthopedic Department of Traditional Chinese Medicine (TCM) and Western Medicine,HongHui Hospital from January 2018 to January 2021 were retrospective analysis.There were 27 males and 16 females,aged (36.0±9.4) years(range:25 to 50 years).AO classification:15 cases of 42A,11 cases of 42B, and 17 cases of 42C.There were 7 open fractures and Gustilo fracture classification:2 cases of type Ⅰ,4 cases of type Ⅱ,and 1 case of type Ⅲ.The two or three plane rings were connected with six connecting rods to form a complete six-axis external fixation frame,and the distal and proximal fracture blocks were connected to the distal and proximal rings by fixation pins,and the lengths of the six connecting rods needed to be adjusted were calculated by using the supporting software according to the CT data after surgery,and then the lengths of the connecting rods were adjusted one by one to complete the reduction of the fracture. The reduction accuracy of this six-axis external fixation brace was evaluated by measuring postoperative radiographs; postoperative recovery and complications were collected,the time of brace removal was recorded,and the function of the affected limb was evaluated according to the Johner-Wruhs score at the final follow-up.Results:Postoperative radiographs showed that all patients achieved satisfactory reduction with lateral displacement( M(IQR)) of 2.3(2.5) mm (range:0.3 to 7.3 mm),anteroposterior displacement of 2.1 (2.4) mm (range:0.3 to 5.7 mm),anteroposterior angulation of 2.5(2.4)°(range:0 to 5°),internal and external angulation of 2.1(1.5)°(range:0 to 4°), and no significant internal or external rotational deformity was detected on the exterior.On the second postoperative day,all patients were able to walk with partial weight-bearing on crutches. All 43 patients were followed up for more than 6 months,with a follow-up period of (33.3±7.3) weeks (range:24 to 42 weeks).The external fixation frame was removed after the fracture healed.The external frame was removed at 20(3)weeks (range:18 to 25 weeks) postoperatively. Up to the final follow up, no secondary fracture occurred in any of them.The Johner-Wruhs score of the affected limb at the last follow-up was excellent in 39 cases and good in 4 cases. Conclusion:The digital six-axis external fixator based on CT data for tibiofibular fractures has the advantages of precise reduction,firm fixation,simple operation,rapid fracture healing,and minimal trauma, which is a minimally invasive method for treating tibiofibular fractures,especially suitable for patients with poor skin and soft tissue conditions such as open injuries.
10.Clinical study of digital six-axis external fixation frame based on CT data for tibiofibular fractures
Bin JIA ; Chen FEI ; Jing REN ; Min WANG ; Jinlong HE ; Zhaochen XU ; Yufeng LU ; Liang QI ; Yonghua LIAO ; Feng QIAO
Chinese Journal of Surgery 2022;60(6):552-557
Objective:To investigate the clinical effect of applying the digital six-axis external fixation frame based on CT data in the treatment of tibiofibular fractures.Methods:The clinical data of 43 patients with tibiofibular fractures treated by the self-developed digital six-axis external fixation frame based on CT data at Integrated Orthopedic Department of Traditional Chinese Medicine (TCM) and Western Medicine,HongHui Hospital from January 2018 to January 2021 were retrospective analysis.There were 27 males and 16 females,aged (36.0±9.4) years(range:25 to 50 years).AO classification:15 cases of 42A,11 cases of 42B, and 17 cases of 42C.There were 7 open fractures and Gustilo fracture classification:2 cases of type Ⅰ,4 cases of type Ⅱ,and 1 case of type Ⅲ.The two or three plane rings were connected with six connecting rods to form a complete six-axis external fixation frame,and the distal and proximal fracture blocks were connected to the distal and proximal rings by fixation pins,and the lengths of the six connecting rods needed to be adjusted were calculated by using the supporting software according to the CT data after surgery,and then the lengths of the connecting rods were adjusted one by one to complete the reduction of the fracture. The reduction accuracy of this six-axis external fixation brace was evaluated by measuring postoperative radiographs; postoperative recovery and complications were collected,the time of brace removal was recorded,and the function of the affected limb was evaluated according to the Johner-Wruhs score at the final follow-up.Results:Postoperative radiographs showed that all patients achieved satisfactory reduction with lateral displacement( M(IQR)) of 2.3(2.5) mm (range:0.3 to 7.3 mm),anteroposterior displacement of 2.1 (2.4) mm (range:0.3 to 5.7 mm),anteroposterior angulation of 2.5(2.4)°(range:0 to 5°),internal and external angulation of 2.1(1.5)°(range:0 to 4°), and no significant internal or external rotational deformity was detected on the exterior.On the second postoperative day,all patients were able to walk with partial weight-bearing on crutches. All 43 patients were followed up for more than 6 months,with a follow-up period of (33.3±7.3) weeks (range:24 to 42 weeks).The external fixation frame was removed after the fracture healed.The external frame was removed at 20(3)weeks (range:18 to 25 weeks) postoperatively. Up to the final follow up, no secondary fracture occurred in any of them.The Johner-Wruhs score of the affected limb at the last follow-up was excellent in 39 cases and good in 4 cases. Conclusion:The digital six-axis external fixator based on CT data for tibiofibular fractures has the advantages of precise reduction,firm fixation,simple operation,rapid fracture healing,and minimal trauma, which is a minimally invasive method for treating tibiofibular fractures,especially suitable for patients with poor skin and soft tissue conditions such as open injuries.


Result Analysis
Print
Save
E-mail