1.Interactions Between Intelligent Animals and Electronic Technology: Current State and Future Prospects
Jin-Jing ZHAO ; Yang-Fan ZHOU ; Bing-Ao ZHANG ; Ming YI ; Hong JIANG ; Sheng-Yong XU
Progress in Biochemistry and Biophysics 2024;51(4):890-911
Human-animal interaction has a long-standing tradition dating back to ancient times. With the rapid advancements in intelligent chips, wearable devices, and machine algorithms, the intelligent interaction between animals and electronic technology, facilitated by electronic devices and systems for communication, perception, and control, has become a reality. These electronic devices aim to implement an animal-centric working mode to enhance human understanding of animals and promote the development of animal intelligence and creativity. This article takes medium-sized and large animals as research objects, with the goal of developing their ability enhancement, and introduces the concept of “intelligent animal augmentation system (IAAS)”. This concept is used to describe the characteristics of such devices and provides a comprehensive overview of existing animal and computer interface solutions. In general, IAAS can be divided into implantable and non-implantable types, each composed of interface platforms, perception and interpretation, control and instruction components. Through various levels of enhancement systems and architectural patterns, intelligent interaction between humans and animals can be realized. Although existing IAAS still lack a complete independent interaction system architecture, they hold great promise and development space in the future. Not only can they be applied as substitutes for cutting-edge devices and transportation equipment, but they are also expected to achieve cross-species information interaction through intelligent interconnection. Additionally, IAAS can promote bidirectional interaction between humans and animals, playing a significant role in advancing animal ethics and ecological protection. Furthermore, the development of interaction models based on animal subjects can provide insightful research experiences for the design of human-computer interaction systems, thereby contributing to the more efficient realization of the ambitious goal of human-machine integration.
2.The Quantitative Analysis of Dynamic Mechanisms Impacting Gastric Cancer Cell Proliferation via Serine/glycine Conversion
Jun-Wu FAN ; Xiao-Mei ZHU ; Zhi-Yuan FAN ; Bing-Ya LIU ; Ping AO ; Yong-Cong CHEN
Progress in Biochemistry and Biophysics 2024;51(3):658-672
ObjectiveGastric cancer (GC) seriously affects human health and life, and research has shown that it is closely related to the serine/glycine metabolism. The proliferation ability of tumor cells is greatly influenced by the metabolism of serine and glycine. The aim of this study was to investigate the molecular mechanism of serine/glycine metabolism can affect the proliferation of gastric cancer cells. MethodsIn this work, a stable metabolic dynamic model of gastric cancer cells was established via a large-scale metabolic network dynamic modeling method in terms of a potential landscape description of stochastic and non-gradient systems. Based on the regulation of the model, a quantitative analysis was conducted to investigate the dynamic mechanism of serine/glycine metabolism affecting the proliferation of gastric cancer cells. We introduced random noise to the kinetic equations of the general metabolic network, and applied stochastic kinetic decomposition to obtain the Lyapunov function of the metabolic network parameter space. A stable metabolic network was achieved by further reducing the change in the Lyapunov function tied to the stochastic fluctuations. ResultsDespite the unavailability of a large number of dynamic parameters, we were able to successfully construct a dynamic model for the metabolic network in gastric cancer cells. When extracellular serine is available, the model preferentially consumes serine. In addition, when the conversion rate of glycine to serine increases, the model significantly upregulates the steady-state fluxes of S-adenosylmethionine (SAM) and S-adenosyl homocysteine (SAH). ConclusionIn this paper, we provide evidence supporting the preferential uptake of serine by gastric cancer cells and the important role of serine/glycine conversion rate in SAM generation, which may affect the proliferation ability of gastric cancer cells by regulating the cellular methylation process. This provides a new idea and direction for targeted cancer therapy based on serine/glycine metabolism.
3.Optimization and application of an automatic monitoring module for drug-induced arrhythmias based on population characteristics
Peng LI ; Dai-Hong GUO ; Man ZHU ; Ao GAO ; Hai-Li GUO ; An FU ; An-Qi ZHAO ; Ting-Yong SHI
The Chinese Journal of Clinical Pharmacology 2024;40(9):1345-1349
Objective To develop the functions and optimize the automatic monitoring module for arrhythmias of the adverse drug event active surveillance and assessment system-Ⅱ,in order to continuously improve the performance,enhance the monitoring efficiency,and explore the ways to optimize the module.Methods Expand and optimize the functions of the module,increase the customized configuration,and determine the optimal setting conditions;compare the optimized test data with the results of the evaluation studies on the automatic monitoring of drug-induced arrhythmias in large samples of medicated population previously,and verify the optimization extent as well as the accuracy of the module.Results In the new module optimized according to the characteristics of the monitoring population,the function of"mandatory medical order keywords"was added,and it was determined that the inclusion of 6 electrocardiogram examination-related medical order keywords with a frequency of not less than 2 occurrences was the optimal configuration condition for the optimization of the module;combining the results of the previous automatic monitoring and evaluation researches,the system functions were verified and compared under the conditions of using the whole drugs and 2 kinds of single drug.While there was no loss of true positive cases,the number of cases with system alarms decreased by 30.75%,80.13%and 90.82%,respectively,compared with that before the optimization of the module,and the positive predictive value was significantly improved.Conclusion After the function expansion and optimization,the automatic monitoring module of drug-induced arrhythmias significantly reduces the labor cost of case evaluation and keeps the accuracy of monitoring results constant;the new module can better adapt to the demands of different automatic monitoring modes and operates stably,which is more generalizable and flexible,and provides a new way of considering for the research and development of automatic monitoring modules.
4.Research progress on drug literacy of HIV/AIDS patients
Silian TAN ; Ying ZHANG ; Lianzhao YANG ; Wen QI ; Huaye XIAO ; Lin GUO ; Ao YANG ; Mencheng LIU ; Zhenwei LIU ; Yuelian WEN ; Yong YANG
Chongqing Medicine 2024;53(18):2864-2868
Drug literacy is one of the important components of health literacy,and in recent years,the research on drug literacy has gradually deepened.The polypharmacy treatment and irrational drug use in the patients with HIV/AIDS has increased the burden of drug use,therefore improving the level of drug literacy is the key to maintain the medication efficacy,drug self-administered and safe medication.This paper summa-rized the definition,current status of assessment tools,influencing factors and interventional measures of drug literacy of HIV/AIDS patients in domestic and foreign research in order to provide reference for the develop-ment of assessment tools for drug literacy of HIV/AIDS patients,improve the level of drug literacy of pa-tients,and promote safe and rational use of drugs.
5.ZHOU Peng's Experience in Treating Psoriasis Vulgaris of Blood Stasis Type Based on the Analysis of Dermoscopic Signs
Guo-Ao SHI ; Rui-Ming CHEN ; Xiang JI ; Zhong-Xian LI ; Yong-Qin XIONG ; Xia-Yun ZHOU ; Jing-Jing LI ; Peng ZHOU
Journal of Guangzhou University of Traditional Chinese Medicine 2024;41(8):2109-2115
Professor ZHOU Peng has deeply discussed the pathological characteristics of psoriasis vulgaris,emphasizing that the disease is usually manifested deficiency interweaved with excess,leading to frequent recurrence and persistent refractory,which may lead to psychological and emotional problems of patients.This paper further expounds the effect of blood stasis on the pathogenesis,progression and prognosis of psoriasis,and puts forward a new method of combining Lingnan fire needling and filiform needling acupuncture technique to treat psoriasis vulgaris with blood stasis syndrome.Professor ZHOU Peng believes that the treatment principle of this disease is"regulating the mind first,rectifying blood as a base,syndrome differentiating and eliminating pathogenic factors",aiming at comprehensively considering the etiology and symptoms,in order to achieve more effective treatment results.Combined with the analysis of dermoscopic signs,it provides a possible improvement direction for the treatment of psoriasis vulgaris from a new perspective.
6.Screening of active components and preliminary mechanism exploration of Lycii Fructus for improving osteoporosis based on the zebrafish model
Hui-li ZHENG ; Yong-qing HUA ; Xin-hui LIU ; Meng-ting LI ; Tong ZHOU ; Yue ZHU ; Li YU ; Sheng GUO ; Jin-ao DUAN
Acta Pharmaceutica Sinica 2023;58(1):127-138
Juvenile zebrafish were used to screen the active components of Lycii Fructus for improving osteoporosis. The screening results were further verified by zebrafish adult osteoporosis model and the action mechanism was explored. Prednisolone was used as the inducer to build osteoporosis models of juvenile and adult zebrafish, and 9 groups of samples of different extracts and chemical parts of Lycii Fructus were given. Alizarin red staining was applied for observing the scale matrix mineralization and bone resorption. The activities of osteoblasts and osteoclasts were detected using alkaline phosphatase (ALP) and tartrate resistant acid phosphatase (TRAP/TRACP) staining. The expressions of bone metabolism-related genes
7.Automatic determination of mandibular landmarks based on three-dimensional mandibular average model.
Zi Xiang GAO ; Yong WANG ; Ao Nan WEN ; Yu Jia ZHU ; Qing Zhao QIN ; Yun ZHANG ; Jing WANG ; Yi Jiao ZHAO
Journal of Peking University(Health Sciences) 2023;55(1):174-180
OBJECTIVE:
To explore an efficient and automatic method for determining the anatomical landmarks of three-dimensional(3D) mandibular data, and to preliminarily evaluate the performance of the method.
METHODS:
The CT data of 40 patients with normal craniofacial morphology were collected (among them, 30 cases were used to establish the 3D mandibular average model, and 10 cases were used as test datasets to validate the performance of this method in determining the mandibular landmarks), and the 3D mandibular data were reconstructed in Mimics software. Among the 40 cases of mandibular data after the 3D reconstruction, 30 cases that were more similar to the mean value of Chinese mandibular features were selected, and the size of the mandibular data of 30 cases was normalized based on the Procrustes analysis algorithm in MATLAB software. Then, in the Geomagic Wrap software, the 3D mandibular average shape model of the above 30 mandibular data was constructed. Through symmetry processing, curvature sampling, index marking and other processing procedures, a 3D mandible structured template with 18 996 semi-landmarks and 19 indexed mandibular anatomical landmarks were constructed. The open source non-rigid registration algorithm program Meshmonk was used to match the 3D mandible template constructed above with the tested patient's 3D mandible data through non-rigid deformation, and 19 anatomical landmark positions of the patient's 3D mandible data were obtained. The accuracy of the research method was evaluated by comparing the distance error of the landmarks manually marked by stomatological experts with the landmarks marked by the method of this research.
RESULTS:
The method of this study was applied to the data of 10 patients with normal mandibular morphology. The average distance error of 19 landmarks was 1.42 mm, of which the minimum errors were the apex of the coracoid process [right: (1.01±0.44) mm; left: (0.56±0.14) mm] and maximum errors were the anterior edge of the lowest point of anterior ramus [right: (2.52±0.95) mm; left: (2.57±1.10) mm], the average distance error of the midline landmarks was (1.15±0.60) mm, and the average distance error of the bilateral landmarks was (1.51±0.67) mm.
CONCLUSION
The automatic determination method of 3D mandibular anatomical landmarks based on 3D mandibular average shape model and non-rigid registration algorithm established in this study can effectively improve the efficiency of automatic labeling of 3D mandibular data features. The automatic determination of anatomical landmarks can basically meet the needs of oral clinical applications, and the labeling effect of deformed mandible data needs to be further tested.
Humans
;
Imaging, Three-Dimensional/methods*
;
Mandible/diagnostic imaging*
;
Software
;
Algorithms
;
Anatomic Landmarks/anatomy & histology*
8.Preliminary study on three-dimensional morphological reconstruction method for external nose defect based on three-dimensional face template.
Ao Nan WEN ; Yong WANG ; Hong Qiang YE ; Zi Xiang GAO ; Yu Jia ZHU ; Qing Zhap QIN ; Hui Zhen HU ; Yun Song LIU ; Yi Jiao ZHAO
Chinese Journal of Stomatology 2023;58(5):414-421
Objective: To provide a new solution for the digital design of nasal prostheses, this study explores the three-dimensional (3D) facial morphology completion method for external nasal defects based on the non-rigid registration process of 3D face template. Methods: A total of 20 male patients with tooth defect and dentition defect who visited the Department of Prosthodontics, Peking University School and Hospital of Stomatology from June to December 2022 were selected, age 18-45 years old. The original 3D facial data of patients were collected, and the 3D facial data of the external nose defect was constructed in Geomagic Wrap 2021 software. Using the structured 3D face template data constructed in the previous research of the research group, the 3D face template was deformed and registered to the 3D facial data of external nose defect (based on the morphology of non-defective area) by non-rigid registration algorithm (MeshMonk program), and the personalized deformed data of the 3D face template was obtained, as the complemented facial 3D data. Based on the defect boundary of the 3D facial data of the external nose defect, the complemented external nose 3D data can be cut out from the complemented facial 3D data. Then the nasofacial angle and nasolabial angle of the complemented facial 3D data and the original 3D facial data was compared and analyzed, the ratio between the nose length and mid-face height, nose width and medial canthal distance of the complemented facial 3D data was measured, the edge fit between the edge curve of the complemented external nose 3D data and the defect edge curve of the 3D facial data of external nose defect was evaluated, and the morphological difference of the nose between the complemented external nose 3D data and the original 3D facial data was analyzed. Results: There was no significant statistically difference (t=-0.23, P=0.823; Z=-1.72, P=0.086) in the nasofacial angle (28.2°±2.9°, 28.4°±3.5° respectively) and nasolabial angle [95.4°(19.2°), 99.9°(9.5°) respectively] between the 20 original 3D facial data and the complemented facial 3D data. The value of the ratio of nose length to mid-face height in the complemented facial 3D data was 0.63±0.03, and the value of the ratio of nose width to medial canthal distance was 1.07±0.08. The curve deviation (root mean square value) between the edge curve of the complemented external nose 3D data and the defect edge curve of the 3D facial data of external nose defect was (0.37±0.09) mm, the maximum deviation was (1.14±0.32) mm, and the proportion of the curve deviation value within±1 mm was (97±3)%. The distance of corresponding nose landmarks between the complemented facial 3D data and the original 3D facial data were respectively, Nasion: [1.52(1.92)] mm; Pronasale: (3.27±1.21) mm; Subnasale: (1.99±1.09) mm; Right Alare: (2.64±1.34) mm; Left Alare: (2.42± 1.38) mm. Conclusions: The method of 3D facial morphology completion of external nose defect proposed in this study has good feasibility. The constructed complemented external nose 3D data has good facial coordination and edge fit, and the morphology is close to the nose morphology of the original 3D facial data.
9.The design method of the digital sequential tooth-sectioning guide for the extraction of mandibular impacted third molars.
Zi Xiang GAO ; Yi Jiao ZHAO ; Yu Jia ZHU ; Ning XIAO ; Ao Nan WEN ; Wei ZHOU ; Bo Chun MAO ; Yun ZHANG ; Wei QI ; Yong WANG
Chinese Journal of Stomatology 2023;58(5):435-441
Objective: To explore a method for digitally designing and fabricating a sequential tooth-sectioning guide that can assist in the extraction of mandibular horizontal impacted third molars, preliminarily evaluate its feasibility and provide a reference for clinical application. Methods: Twenty patients with mandibular low level impacted third molars who visited the Department of General Dentistry, Peking University School and Hospital of Stomatology from March 2021 to January 2022 were selected. Cone-beam CT showed direct contact between the roots and mandibular canal, and full range impressions of the patients' intraoral teeth were taken and optical scans of the dental model were performed. The patients' cone-beam CT data and optical scan data were reconstructed in three dimensions, anatomical structure extraction, registration fusion, and the design of the structure of the guide (including crown-sectioning guide and root-sectioning guide) by Mimics 24.0, Geomagic Wrap 2021, and Magics 21.0 software, and then the titanium guide was three dimension printed, and the guide was tried on the dental model. After confirmation, the guide was used to assist the dentist in the operation. We observed whether the guide was in place, the number of tooth splitting, the matching of tooth splitting with the preoperative design, the operation time, and whether there were any complications. Results: In this study, 20 sectioning guides were successfully printed, all of them were well fitted in the patients' mouth, the average number of section was 3.4 times, the tooth parts was better matched with the preoperative design, and the average operative time of the guides was (29.2±9.8) minutes without complications such as perforation of the bone cortex. Conclusions: The use of sequential sectioning guides to assist in the extraction of mandibular impacted third molars was initially validated to accurately replicate the preoperative sectioning design, and is expected to provide a digital solution to improve surgical precision and ensure safety. Further studies with larger sample sizes are needed to evaluate its accuracy and safety.
10.Study on the method of automatically determining maxillary complex landmarks based on non-rigid registration algorithms.
Zi Xiang GAO ; Jing WANG ; Ao Nan WEN ; Yu Jia ZHU ; Qing Zhao QIN ; Yong WANG ; Yi Jiao ZHAO
Chinese Journal of Stomatology 2023;58(6):554-560
Objective: To explore an automatic landmarking method for anatomical landmarks in the three-dimensional (3D) data of the maxillary complex and preliminarily evaluate its reproducibility and accuracy. Methods: From June 2021 to December 2022, spiral CT data of 31 patients with relatively normal craniofacial morphology were selected from those who visited the Department of Oral and Maxillofacial Surgery, Peking University School and Hospital of Stomatology. The sample included 15 males and 16 females, with the age of (33.3±8.3) years. The maxillary complex was reconstructed in 3D using Mimics software, and the resulting 3D data of the maxillary complex was mesh-refined using Geomagic software. Two attending physicians and one associate chief physician manually landmarked the 31 maxillary complex datasets, determining 24 anatomical landmarks. The average values of the three expert landmarking results were used as the expert-defined landmarks. One case that conformed to the average 3D morphological characteristics of healthy individuals' craniofacial bones was selected as the template data, while the remaining 30 cases were used as target data. The open-source MeshMonk program (a non-rigid registration algorithm) was used to perform an initial alignment of the template and target data based on 4 landmarks (nasion, left and right zygomatic arch prominence, and anterior nasal spine). The template data was then deformed to the shape of the target data using a non-rigid registration algorithm, resulting in the deformed template data. Based on the unchanged index property of homonymous landmarks before and after deformation of the template data, the coordinates of each landmark in the deformed template data were automatically retrieved as the automatic landmarking coordinates of the homonymous landmarks in the target data, thus completing the automatic landmarking process. The automatic landmarking process for the 30 target data was repeated three times. The root-mean-square distance (RMSD) of the dense corresponding point pairs (approximately 25 000 pairs) between the deformed template data and the target data was calculated as the deformation error of the non-rigid registration algorithm, and the intra-class correlation coefficient (ICC) of the deformation error in the three repetitions was analyzed. The linear distances between the automatic landmarking results and the expert-defined landmarks for the 24 anatomical landmarks were calculated as the automatic landmarking errors, and the ICC values of the 3D coordinates in the three automatic landmarking repetitions were analyzed. Results: The average three-dimensional deviation (RMSD) between the deformed template data and the corresponding target data for the 30 cases was (0.70±0.09) mm, with an ICC value of 1.00 for the deformation error in the three repetitions of the non-rigid registration algorithm. The average automatic landmarking error for the 24 anatomical landmarks was (1.86±0.30) mm, with the smallest error at the anterior nasal spine (0.65±0.24) mm and the largest error at the left oribital (3.27±2.28) mm. The ICC values for the 3D coordinates in the three automatic landmarking repetitions were all 1.00. Conclusions: This study established an automatic landmarking method for three-dimensional data of the maxillary complex based on a non-rigid registration algorithm. The accuracy and repeatability of this method for landmarking normal maxillary complex 3D data were relatively good.
Male
;
Female
;
Humans
;
Adult
;
Imaging, Three-Dimensional/methods*
;
Reproducibility of Results
;
Algorithms
;
Software
;
Tomography, Spiral Computed
;
Anatomic Landmarks/anatomy & histology*

Result Analysis
Print
Save
E-mail