1.Sex differences in cardiovascular health among children aged 6-8 years in Beijing City
GUAN Mengying, JIANG Xiaofeng, SHU Wen, LI Menglong, XIAO Huidi, ASIHAER Yeerlin, HU Yifei
Chinese Journal of School Health 2024;45(1):36-40
Objective:
To explore sex difference in the cardiovascular health (CVH) status of 6-8 year old children in Beijing, so as to inform the early intervention of CVH related lifestyles.
Methods:
Based on the Beijing Children s Growth and Health Cohort (PROC), baseline physical examination, sequential questionnaire survey, and laboratory tests were conducted among 1 914 grade 1 students. Children s CVH and its subscales (health behaviors and health factors) scores were calculated according to the Life s Essential 8 (LE 8) index and categorized into high, moderate, and low CVH. CVH scores were reported as medians and interquartile ranges; sex differences were compared using the Chi square test and Wilcoxon test.
Results:
Among the 1 914 participants, the percentages of high, moderate, and low CVH were 35.7%, 63.5%, and 0.8%, respectively, and the percentages of high, moderate, and low health behavior scores were 25.9%, 67.5%, and 6.6%, respectively, with no statistically significant differences between sex ( χ 2=2.30, 0.07, P >0.05). The rates of high, moderate, and low health factor scores for boys and girls were 61.1%, 36.0%, 2.9% and 71.1%, 28.4%, 0.5%, respectively, with a statistically significant sex difference ( χ 2=31.88, P < 0.01). The overall CVH score was 76.0(70.0, 83.0), 76.0(69.0, 82.0) for boys, and 77.0(71.0, 83.0) for girls. Among the health behavior metrics, sleep scores were the best and physical activity scores were the worst[100.0(90.0,100.0), 40.0(20.0, 80.0 )]; among the health factor metrics, blood glucose scores were the best and lipid scores were the worst[100.0(100.0,100.0), 60.0(40.0,100.0)]. In respect to health factors, there were significant gender differences in body mass index, blood lipids, blood sugar, and blood pressure scores ( Z =-6.92, 3.01, -6.60, -2.30, <0.05), but there were no significant gender differences in diet, physical activity, nicotine exposure, or sleep scores with regards to health behaviors ( Z =0.99, 0.88, -0.13, 0.36, P > 0.05 ). Compared to boys, girls in the low and moderate CVH groups had high health factor scores despite low health behavior scores.
Conclusion
Most 6 to 8-year-old children in Beijing were found to have relatively good CVH, and optimization of children s CVH status can be achieved by promoting healthier lifestyles and monitoring health factors, especially among boys.
2.Entrance surface dose of digital radiography adult examinees in a grade A tertiary hospital in Shanghai
Yanmei WANG ; Jie YAO ; Yan LI ; Song JIANG ; Yifei BAI
Shanghai Journal of Preventive Medicine 2024;36(5):458-462
ObjectiveTo investigate the entrance surface dose (ESD) of digital radiography (DR)adult examinees in a grade A tertiary hospital in Shanghai, to analyze the dose level of the DR adult examinees, and to provide data for the development of DR typical dose reference. MethodsA DR equipment in the hospital was selected and the irradiation parameters and dose were determined in two randomly selected age groups (15‒39 years and 40‒69 years) of DR adult examinees. The examinations included chest PA, chest LAT, abdominal AP, pelvic AP, lumbar AP, lumbar LAT, thoracic AP, and thoracic LAT. The number of examinees in each exposure position was 20. ESD and effective dose were calculated for each age group and each position. ResultsA total of 320 examinees were investigated. The 75th percentiles of ESD in different exposure positions were as follows: chest PA 0.19 mGy;chest LAT 0.96 mGy;abdominal AP 3.63 mGy;pelvic AP 3.16 mGy;lumbar AP 9.27 mGy;lumbar LAT 18.29 mGy;thoracic AP 6.85 mGy;and thoracic LAT 13.40 mGy. ConclusionsThe differences between the estimated ESD and effective dose were large in different exposure positions、in the same exposure positions、and in the same positions with different exposure types, and there were statistically significant differences in ESD of examinees with different exposure positions. The estimated typical values of different exposure positions were apparently lower than the diagnostic reference level.
3.A digital anatomy study of the secure corridor for infra-acetabular screw placement
Gang LYU ; Chao MA ; Zhiqiang MA ; Yushan MAIMAIAILI ; Haiming SA ; Jiang ZHU ; Tuoliewuhan WUYILAHAN ; Yifei HUANG
Chinese Journal of Orthopaedic Trauma 2024;26(3):209-214
Objective:To compare the parameters for infra-acetabular screw placement between men and women using a digital Chinese anatomical model of the pelvis and acetabulum.Methods:The normal pelvic CT data were collected from the 163 adult patients who had been admitted to the Traditional Chinese Medicine Hospital of Xinjiang Uygur Autonomous Region from January 2018 to December 2021. There were 61 males and 102 females with an age of 53.0 (45.0, 60.0) years. Mimics 21.0 software was used to reconstruct the three dimensional pelvis which was then imported into Autodesk maya 2022 software before the model was flattened. Polygonal modeling tools were used to create a cylinder to simulate an infra-acetabular screw for length and angle measurements of the screw. The diameters of the infra-acetabular screws were measured by axial fluoroscopy in Mimics 21.0 software. The maximum diameters and maximum lengths of the infra-acetabular bone channel were compared between males and females, and the angles between the axis of the infra-acetabular screw and the anterior pelvic plane and the median sagittal plane were also compared between genders.Results:The maximum diameters of the left and right infra-acetabular corridors were 5.24 (4.26, 6.38) mm and 5.04 (4.50, 6.57) mm in males, and 3.99 (3.81, 4.51) mm and 3.89 (3.65, 4.90) mm in females; the maximum lengths of the left and right infra-acetabular corridors were (98.43±4.42) mm and (98.01±5.08) mm in males and 87.73 (84.22, 90.98) mm and 87.51 (84.59, 90.15) mm in females. The left and right angles between the infra-acetabular screw axis and the median sagittal plane were -0.98°±4.79° and -1.08°±4.91° in men, and 6.20° (3.34°, 11.16°) and 6.44° (3.77°, 11.85°) in women. The differences in the above data between men and women were statistically significant ( P<0.05). There was no statistically significant difference between men and women in the angle between the infra-acetabular screw axis and the anterior pelvic plane ( P>0.05). Conclusions:The length and diameter of the infra-acetabular corridor in males are greater than those in females, the angle between the infra-acetabular corridor and the sagittal plane in males is smaller than that in females, and the infra-acetabular corridor in males is more parallel to the sagittal plane. Therefore, the fluoroscopy angle should be adjusted for males to reduce the difficulty in screw placement when an infra-acetabular screw is placed during surgery.
4.Metagenomic next-generation sequencing for the diagnosis of Pneumocystis jirovecii pneumonia after allogeneic hematopoietic stem cell transplantation
Rong FU ; Ren LIN ; Zhiping FAN ; Fen HUANG ; Na XU ; Li XUAN ; Yifei HUANG ; Hui LIU ; Ke ZHAO ; Zhixiang WANG ; Ling JIANG ; Min DAI ; Jing SUN ; Qifa LIU
Chinese Journal of Hematology 2024;45(1):62-67
Objectives:To investigate the value of metagenomic next-generation sequencing (mNGS) in the diagnosis of Pneumocystis jirovecii pneumonia (PJP) in patients undergoing allogeneic hematopoietic stem cell transplantation (allo-HSCT) .Methods:The data of 98 patients with suspected pulmonary infection after allo-HSCT who underwent pathogen detection from bronchoalveolar lavage fluid between June 2016 and August 2023 at Nanfang Hospital were analyzed. The diagnostic performance of mNGS, conventional methods, and real-time quantitative polymerase chain reaction (qPCR) for PJP were compared.Results:A total of 12 patients were diagnosed with PJP, including 11 with a proven diagnosis and 1 with a probable diagnosis. Among the patients with a proven diagnosis, 1 was positive by both conventional methods and qPCR, and 10 were positive by qPCR only. Pneumocystis jirovecii was detected by mNGS in all 12 patients. The diagnostic sensitivity of mNGS for PJP was 100%, which was greater than that of conventional methods (8.3%, P=0.001) and similar to that of qPCR (91.6%, P=1.000) . A total of 75% of the patients developed mixed pulmonary infections, and cytomegalovirus and Epstein-Barr virus were the most common pathogens. Mixed infection was detected in eight patients by mNGS and in five patients by qPCR, but not by conventional methods ( P=0.008) . Conclusions:mNGS had good sensitivity for diagnosing PJP after allo-HSCT and was advantageous for detecting mixed infectious pathogens; therefore, mNGS might be an effective supplement to regular detection methods and qPCR.
5.Application progress of exergames in health interventions for the elderly
Xi CHEN ; Hongting NING ; Shuang WU ; Lina WU ; Dian JIANG ; Yifei CHEN ; Zeng CAO ; Hui FENG
Journal of Central South University(Medical Sciences) 2024;49(4):534-540
With the aging population in China,health issues among the elderly are becoming increasingly prominent,leading to a rapidly growing demand for health interventions for the elderly.Exergames are one of the important emerging methods in the field of health interventions for the elderly,widely used and yielding positive results.While research on exergames is well-established abroad,it is still in its infancy in China,lacking reports on the types,interaction forms,intervention content,application status,and effectiveness of exergames.Exergames are suitable for widespread use among the elderly in China,and there is a need to accelerate the development and application of exergames in the field of health interventions for the elderly in China.
6.Emphasizing the Importance of Transcatheter Interventional Techniques Application in the Diagnosis and Treatment of Hypertension
Xiongjing JIANG ; Hui DONG ; Yifei DONG ; Jianzhong XU ; Nan JIA ; Zhiming ZHU ; Runlin GAO
Chinese Circulation Journal 2024;39(8):751-754
Hypertension is the most common chronic non-communicable disease and the primary risk factor for cardiovascular events.The traditional management methods for hypertension are often purely internal medicine and basically unrelated to percutaneous interventional techniques.In recent decades,with the development of imaging technology and interventional devices,the application of transcatheter interventional techniques in hypertension has become widespread.This article reviews the current status and prospect of transcatheter interventional techniques in the clinical diagnosis and treatment of hypertension.
7.Mechanical properties and clinical application of femoral neck system
Haiming SA ; Zhiqiang MA ; Yushan MAIMAIAILI· ; Yifei HUANG ; Tuoliewuhan WUYILAHAN· ; Jiang ZHU ; Wu XU ; Tao LI ; Gang LYU
Chinese Journal of Orthopaedic Trauma 2024;26(6):499-504
The principles for surgical treatment of femoral neck fracture are anatomical reduction, rigid fixation and reduction of iatrogenic tissue damage to maintain sufficient blood supply and reduce the risk of complications such as avascular necrosis of the femoral head. In the evolution of internal fixation structures for femoral neck fracture, a variety of new products have been developed, such as the neck-shaft angle stabilization structure represented by dynamic hip screw, the multi-screw structure represented by three cannulated screws, and the plate-screw structure represented by multi-screw structure combined with a locked plate. These internal fixation structures have their own advantages and disadvantages in terms of stability and reduced risk of complications. However, none of them can perfectly meet the requirements of all the surgical principles. Femoral neck system (FNS) was firstly applied in clinic practice in 2017 to further improve the internal fixation of femoral neck fracture. In recent years, its mechanical properties and clinical effects have been widely reported in an attempt to further improve the implantation of this internal fixation device. This article reviews the researches on the mechanical properties and clinical efficacy of FNS and the suggestions put forward by orthopedic surgeons to improve the implantation methods of FNS.
8.Effect of spinopelvic sagittal alignment and lordosis distribution index on adjacent segment degeneration after short-segment lumbar interbody fusion
Xin WANG ; Dong ZHOU ; Muyi WANG ; Nanwei XU ; Yuqing JIANG ; Yong QIU ; Xu SUN ; Yifei SHEN
Chinese Journal of Orthopaedics 2024;44(8):553-560
Objective:To investigate the effect of spinopelvic sagittal alignment and lordosis distribution index on adjacent segment degeneration (ASD) after short-segment lumbar interbody fusion.Methods:A total of 234 patients who underwent posterior lumbar interbody fusion due to lumbar degenerative diseases in the Affiliated Changzhou Second People's Hospital of Nanjing Medical University and Affiliated Drum Tower Hospital, Medical School of Nanjing University from January 2009 to January 2019 were retrospectively analyzed. There were 102 males and 132 females, aged 60.1±10.0 years (range, 41-78 years). The patients were divided into ASD group and non-ASD group according to whether ASD occurred after operation. The general data, pelvic incidence (PI), sacral slope (SS), pelvic tilt (PT), lumbar lordosis (LL), distal lordosis (DL), segmental lordosis (SL), lordosis distribution index (LDI) and sagittal vertical axis (SVA) before and after operation were compared between the two groups. Independent risk factors for the occurrence of ASD after lumbar fusion were analyzed using binary logistic regression. The receiver operating characteristic curve (ROC) was plotted, and the area under the curve was calculated for each independent risk factor.Results:All patients successfully completed the operation and were followed up for 70.6±11.9 months (range, 60-121 months). Among the 234 patients, 116 patients developed ASD after operation. Age ( t=2.697, P=0.008), fusion segment (χ 2=16.439, P<0.001), preoperative PT ( t=2.268, P=0.024), preoperative LL ( t=2.042, P=0.042), preoperative DL ( t=2.724, P=0.007), postoperative DL ( t=3.104, P=0.002), postoperative LDI ( t=2.063, P=0.040) and the difference of SVA before and after operation ( Z=2.001, P=0.045) were statistically significant. Binary logistic regression analysis showed that LDI decreased ( OR=0.971, P=0.002), two-level fusion ( OR=3.477, P<0.001), and increased SVA difference before and after operation ( OR=0.992, P=0.039) were independent risk factors for ASD after lumbar fusion. The ROC curve showed that the area under the curve and 95% CI of the number of fusion segments, postoperative LDI, and the difference of SVA before and after operation were 0.633 (0.561, 0.704), 0.583 (0.510, 0.656) and 0.576 (0.502, 0.649), respectively. The area under the curve of the combined prediction model was 0.702, and the prediction value was medium. Conclusion:Two-level fusion, decreased LDI after operation, and increased SVA difference before and after operation are independent risk factors for ASD after lumbar fusion, and the combined prediction of the three has good predictive efficiency.
9.Design and implementation of a modular pulse wave preprocessing and analysis system based on a new detection algorithm.
Feng JIANG ; Zhibin ZHU ; Mengge ZHANG ; Jingwen FENG ; Yifei XU ; Hang CHEN
Journal of Biomedical Engineering 2023;40(3):529-535
As one of the standard electrophysiological signals in the human body, the photoplethysmography contains detailed information about the blood microcirculation and has been commonly used in various medical scenarios, where the accurate detection of the pulse waveform and quantification of its morphological characteristics are essential steps. In this paper, a modular pulse wave preprocessing and analysis system is developed based on the principles of design patterns. The system designs each part of the preprocessing and analysis process as independent functional modules to be compatible and reusable. In addition, the detection process of the pulse waveform is improved, and a new waveform detection algorithm composed of screening-checking-deciding is proposed. It is verified that the algorithm has a practical design for each module, high accuracy of waveform recognition and high anti-interference capability. The modular pulse wave preprocessing and analysis software system developed in this paper can meet the individual preprocessing requirements for various pulse wave application studies under different platforms. The proposed novel algorithm with high accuracy also provides a new idea for the pulse wave analysis process.
Humans
;
Systems Analysis
;
Algorithms
;
Software
;
Heart Rate
;
Microcirculation


Result Analysis
Print
Save
E-mail