1.Feasibility study of a domestic fully automated NAT system for blood screening in blood donors
Fenglan YAO ; Rui WANG ; Jinghui HU ; Hongwei GE ; Chan LENG ; Yi ZHA ; Zifu ZHAO ; Zhengmin LIU
Chinese Journal of Blood Transfusion 2025;38(7):941-949
Objective: To validate the analytical performance, operational performance, and process control measures of a domestic fully automatic nucleic acid testing (NAT) system, thereby ensuring an efficient and orderly blood screening workflow. Methods: The concordance rate and sensitivity of WanTag-Vortex Plus system were verified using WHO standard reference panels of HIV-1, HCV and HBV, while precision was assessed using weak positive samples of HIV-1, HCV and HBV. As for its operational performance evaluation, cross-contamination resistance was assessed using strong positive samples, and throughput and stress testing were conducted using negative samples. Reagent stability was verified using weak positive samples, and inter-system performance consistency was assessed using verification panels. In addition, the process control measures were verified using the laboratory quality control demand scale. Results: 1) Verification of concordance rate: The detection results of negative and positive samples of HIV-1, HCV and HBV by WanTag-Vortex Plus system were all consistent with expectations, and the concordance rate was 100%. 2) Precision verification: the repeatability and intermediate precision were extremely high, and the coefficient of variation was less than 5%. 3) Verification of analytical sensitivity: The detection limit of 95% for standard strains of HIV-1, HCV and HBV by WanTag-Vortex Plus system in our laboratory was consistent with the analytical sensitivity provided by reagent manufacturers. 4) Verification of cross-contamination resistance: Five strong positive samples and 87 negative samples were placed according to the actual working conditions and equipment operation design, and the test results were consistent with expectations, with no cross-contamination in the testing system. 5) Throughput and stress testing: Each system completed the individual donor-nucleic acid amplification testing (ID-NAT) of 276 samples in three batches within 12 hours, and successfully completed the ID-NAT test of 828 samples in three consecutive days. 6) Verification of reagent stability: After extreme storage (unsealed storage for 1 week with 4 freeze-thaw cycles), the reagents maintained 100% detection rate in the weak positive samples of HIV-1, HCV, and HBV, showing no significant differences from the control group (Kappa=1). 7) Verification of inter-system performance consistency: The system has stable operation performance, and the performance comparison results across the four devices were consistent (Kappa=1). 8) Process control measures: WanTag-Vortex Plus system software accurately controlled the equipment operation process with strict quality control measures, and correctly interpreted and safely reported the test results. Conclusion: The analytical and operational performance of the WanTag-Vortex Plus system complies with manufacturer design standards and essential laboratory workflow requirements. Integrated with laboratory information system (LIS), the system's control software meets standard process control requirements, yet requires further improvement.
2.Feasibility study of a domestic fully automated NAT system for blood screening in blood donors
Fenglan YAO ; Rui WANG ; Jinghui HU ; Hongwei GE ; Chan LENG ; Yi ZHA ; Zifu ZHAO ; Zhengmin LIU
Chinese Journal of Blood Transfusion 2025;38(7):941-949
Objective: To validate the analytical performance, operational performance, and process control measures of a domestic fully automatic nucleic acid testing (NAT) system, thereby ensuring an efficient and orderly blood screening workflow. Methods: The concordance rate and sensitivity of WanTag-Vortex Plus system were verified using WHO standard reference panels of HIV-1, HCV and HBV, while precision was assessed using weak positive samples of HIV-1, HCV and HBV. As for its operational performance evaluation, cross-contamination resistance was assessed using strong positive samples, and throughput and stress testing were conducted using negative samples. Reagent stability was verified using weak positive samples, and inter-system performance consistency was assessed using verification panels. In addition, the process control measures were verified using the laboratory quality control demand scale. Results: 1) Verification of concordance rate: The detection results of negative and positive samples of HIV-1, HCV and HBV by WanTag-Vortex Plus system were all consistent with expectations, and the concordance rate was 100%. 2) Precision verification: the repeatability and intermediate precision were extremely high, and the coefficient of variation was less than 5%. 3) Verification of analytical sensitivity: The detection limit of 95% for standard strains of HIV-1, HCV and HBV by WanTag-Vortex Plus system in our laboratory was consistent with the analytical sensitivity provided by reagent manufacturers. 4) Verification of cross-contamination resistance: Five strong positive samples and 87 negative samples were placed according to the actual working conditions and equipment operation design, and the test results were consistent with expectations, with no cross-contamination in the testing system. 5) Throughput and stress testing: Each system completed the individual donor-nucleic acid amplification testing (ID-NAT) of 276 samples in three batches within 12 hours, and successfully completed the ID-NAT test of 828 samples in three consecutive days. 6) Verification of reagent stability: After extreme storage (unsealed storage for 1 week with 4 freeze-thaw cycles), the reagents maintained 100% detection rate in the weak positive samples of HIV-1, HCV, and HBV, showing no significant differences from the control group (Kappa=1). 7) Verification of inter-system performance consistency: The system has stable operation performance, and the performance comparison results across the four devices were consistent (Kappa=1). 8) Process control measures: WanTag-Vortex Plus system software accurately controlled the equipment operation process with strict quality control measures, and correctly interpreted and safely reported the test results. Conclusion: The analytical and operational performance of the WanTag-Vortex Plus system complies with manufacturer design standards and essential laboratory workflow requirements. Integrated with laboratory information system (LIS), the system's control software meets standard process control requirements, yet requires further improvement.
3.Chinese expert consensus on blood support mode and blood transfusion strategies for emergency treatment of severe trauma patients (version 2024)
Yao LU ; Yang LI ; Leiying ZHANG ; Hao TANG ; Huidan JING ; Yaoli WANG ; Xiangzhi JIA ; Li BA ; Maohong BIAN ; Dan CAI ; Hui CAI ; Xiaohong CAI ; Zhanshan ZHA ; Bingyu CHEN ; Daqing CHEN ; Feng CHEN ; Guoan CHEN ; Haiming CHEN ; Jing CHEN ; Min CHEN ; Qing CHEN ; Shu CHEN ; Xi CHEN ; Jinfeng CHENG ; Xiaoling CHU ; Hongwang CUI ; Xin CUI ; Zhen DA ; Ying DAI ; Surong DENG ; Weiqun DONG ; Weimin FAN ; Ke FENG ; Danhui FU ; Yongshui FU ; Qi FU ; Xuemei FU ; Jia GAN ; Xinyu GAN ; Wei GAO ; Huaizheng GONG ; Rong GUI ; Geng GUO ; Ning HAN ; Yiwen HAO ; Wubing HE ; Qiang HONG ; Ruiqin HOU ; Wei HOU ; Jie HU ; Peiyang HU ; Xi HU ; Xiaoyu HU ; Guangbin HUANG ; Jie HUANG ; Xiangyan HUANG ; Yuanshuai HUANG ; Shouyong HUN ; Xuebing JIANG ; Ping JIN ; Dong LAI ; Aiping LE ; Hongmei LI ; Bijuan LI ; Cuiying LI ; Daihong LI ; Haihong LI ; He LI ; Hui LI ; Jianping LI ; Ning LI ; Xiying LI ; Xiangmin LI ; Xiaofei LI ; Xiaojuan LI ; Zhiqiang LI ; Zhongjun LI ; Zunyan LI ; Huaqin LIANG ; Xiaohua LIANG ; Dongfa LIAO ; Qun LIAO ; Yan LIAO ; Jiajin LIN ; Chunxia LIU ; Fenghua LIU ; Peixian LIU ; Tiemei LIU ; Xiaoxin LIU ; Zhiwei LIU ; Zhongdi LIU ; Hua LU ; Jianfeng LUAN ; Jianjun LUO ; Qun LUO ; Dingfeng LYU ; Qi LYU ; Xianping LYU ; Aijun MA ; Liqiang MA ; Shuxuan MA ; Xainjun MA ; Xiaogang MA ; Xiaoli MA ; Guoqing MAO ; Shijie MU ; Shaolin NIE ; Shujuan OUYANG ; Xilin OUYANG ; Chunqiu PAN ; Jian PAN ; Xiaohua PAN ; Lei PENG ; Tao PENG ; Baohua QIAN ; Shu QIAO ; Li QIN ; Ying REN ; Zhaoqi REN ; Ruiming RONG ; Changshan SU ; Mingwei SUN ; Wenwu SUN ; Zhenwei SUN ; Haiping TANG ; Xiaofeng TANG ; Changjiu TANG ; Cuihua TAO ; Zhibin TIAN ; Juan WANG ; Baoyan WANG ; Chunyan WANG ; Gefei WANG ; Haiyan WANG ; Hongjie WANG ; Peng WANG ; Pengli WANG ; Qiushi WANG ; Xiaoning WANG ; Xinhua WANG ; Xuefeng WANG ; Yong WANG ; Yongjun WANG ; Yuanjie WANG ; Zhihua WANG ; Shaojun WEI ; Yaming WEI ; Jianbo WEN ; Jun WEN ; Jiang WU ; Jufeng WU ; Aijun XIA ; Fei XIA ; Rong XIA ; Jue XIE ; Yanchao XING ; Yan XIONG ; Feng XU ; Yongzhu XU ; Yongan XU ; Yonghe YAN ; Beizhan YAN ; Jiang YANG ; Jiangcun YANG ; Jun YANG ; Xinwen YANG ; Yongyi YANG ; Chunyan YAO ; Mingliang YE ; Changlin YIN ; Ming YIN ; Wen YIN ; Lianling YU ; Shuhong YU ; Zebo YU ; Yigang YU ; Anyong YU ; Hong YUAN ; Yi YUAN ; Chan ZHANG ; Jinjun ZHANG ; Jun ZHANG ; Kai ZHANG ; Leibing ZHANG ; Quan ZHANG ; Rongjiang ZHANG ; Sanming ZHANG ; Shengji ZHANG ; Shuo ZHANG ; Wei ZHANG ; Weidong ZHANG ; Xi ZHANG ; Xingwen ZHANG ; Guixi ZHANG ; Xiaojun ZHANG ; Guoqing ZHAO ; Jianpeng ZHAO ; Shuming ZHAO ; Beibei ZHENG ; Shangen ZHENG ; Huayou ZHOU ; Jicheng ZHOU ; Lihong ZHOU ; Mou ZHOU ; Xiaoyu ZHOU ; Xuelian ZHOU ; Yuan ZHOU ; Zheng ZHOU ; Zuhuang ZHOU ; Haiyan ZHU ; Peiyuan ZHU ; Changju ZHU ; Lili ZHU ; Zhengguo WANG ; Jianxin JIANG ; Deqing WANG ; Jiongcai LAN ; Quanli WANG ; Yang YU ; Lianyang ZHANG ; Aiqing WEN
Chinese Journal of Trauma 2024;40(10):865-881
Patients with severe trauma require an extremely timely treatment and transfusion plays an irreplaceable role in the emergency treatment of such patients. An increasing number of evidence-based medicinal evidences and clinical practices suggest that patients with severe traumatic bleeding benefit from early transfusion of low-titer group O whole blood or hemostatic resuscitation with red blood cells, plasma and platelet of a balanced ratio. However, the current domestic mode of blood supply cannot fully meet the requirements of timely and effective blood transfusion for emergency treatment of patients with severe trauma in clinical practice. In order to solve the key problems in blood supply and blood transfusion strategies for emergency treatment of severe trauma, Branch of Clinical Transfusion Medicine of Chinese Medical Association, Group for Trauma Emergency Care and Multiple Injuries of Trauma Branch of Chinese Medical Association, Young Scholar Group of Disaster Medicine Branch of Chinese Medical Association organized domestic experts of blood transfusion medicine and trauma treatment to jointly formulate Chinese expert consensus on blood support mode and blood transfusion strategies for emergency treatment of severe trauma patients ( version 2024). Based on the evidence-based medical evidence and Delphi method of expert consultation and voting, 10 recommendations were put forward from two aspects of blood support mode and transfusion strategies, aiming to provide a reference for transfusion resuscitation in the emergency treatment of severe trauma and further improve the success rate of treatment of patients with severe trauma.
4.Relationship between eczema and indoor environmental factors among preschool children in Haikou
WANG Shuomin, ZHA Yi, ZHANG Jing
Chinese Journal of School Health 2023;44(7):1072-1075
Objective:
To investigate the influencing factors of home environment on eczema in preschool children, so as to provide theoretical basis for taking effective regional prevention for preschool children.
Methods:
From December 2020 to January 2021, a cross sectional survey of 3 049 preschool children was randomly carried out by stratified cluster sampling in Haikou kindergartens, and the impact of indoor environmental factors on preschool children s eczema was analyzed. Chi squared test and binary Logistic regressive were used to analyze the related factors.
Results:
The prevalence of eczema in preschool children was 13.6%. Multivariate Logistic regression showed that the positive correlation factors of eczema included the new decoration in the mother s residence one year before pregnancy ( OR=1.71, 95%CI =1.09-2.68), the addition of new furniture in the child s residence when the child was 0-1 years old ( OR=1.53, 95%CI =1.03-2.27), cockroaches in the house ( OR=1.35, 95%CI =1.02-1.81) and cleaning of less than once per week ( OR=1.30, 95%CI =1.01-1.66). The starting age of children s collective life since 3 years old ( OR=0.76, 95%CI =0.60-0.96) had a negative correlation with eczema ( P <0.05).
Conclusion
There are multiple indoor environmental factors related to eczema among preschool children in Haikou city. Parents should take measures to prevent eczema in preschool children by paying attention to home environment and the starting age of children s collective life.
5.Effect of Home Blood Pressure Telemonitoring Plus Additional Support on Blood Pressure Control: A Randomized Clinical Trial.
Wen Wen MENG ; Yong Yi BAI ; Li YAN ; Wei ZHENG ; Qiang ZENG ; Yan Song ZHENG ; Lin ZHA ; Hong Ying PI ; Xiao Yong SAI
Biomedical and Environmental Sciences 2023;36(6):517-526
OBJECTIVE:
Current clinical evidence on the effects of home blood pressure telemonitoring (HBPT) on improving blood pressure control comes entirely from developed countries. Thus, we performed this randomized controlled trial to evaluate whether HBPT plus support (patient education and clinician remote hypertension management) improves blood pressure control more than usual care (UC) in the Chinese population.
METHODS:
This single-center, randomized controlled study was conducted in Beijing, China. Patients aged 30-75 years were eligible for enrolment if they had blood pressure [systolic (SBP) ≥ 140 mmHg and/or diastolic (DBP) ≥ 90 mmHg; or SBP ≥ 130 mmHg and/or DBP ≥ 80 mmHg with diabetes]. We recruited 190 patients randomized to either the HBPT or the UC groups for 12 weeks. The primary endpoints were blood pressure reduction and the proportion of patients achieving the target blood pressure.
RESULTS:
Totally, 172 patients completed the study, the HBPT plus support group ( n = 84), and the UC group ( n = 88). Patients in the plus support group showed a greater reduction in mean ambulatory blood pressure than those in the UC group. The plus support group had a significantly higher proportion of patients who achieved the target blood pressure and maintained a dipper blood pressure pattern at the 12th week of follow-up. Additionally, the patients in the plus support group showed lower blood pressure variability and higher drug adherence than those in the UC group.
CONCLUSION
HBPT plus additional support results in greater blood pressure reduction, better blood pressure control, a higher proportion of dipper blood pressure patterns, lower blood pressure variability, and higher drug adherence than UC. The development of telemedicine may be the cornerstone of hypertension management in primary care.
Humans
;
Blood Pressure
;
Blood Pressure Monitoring, Ambulatory
;
Hypertension/therapy*
;
Telemedicine/methods*
;
Hypotension
6.Investigation of anxiety and depression of postgraduates in military medical university under public health emergencies
Peitao ZHA ; Minglu LIU ; Shun ZHANG ; Ying ZHANG ; Xue BAI ; Yi ZHENG ; Yingdan TANG ; Ying HE ; Jingxuan ZHANG ; Guoyu YANG
Chinese Journal of Medical Education Research 2023;22(8):1159-1163
Objective:To investigate the characteristics of anxiety and depression of postgraduates in military medical university under public health emergencies.Methods:By means of self-rating anxiety scale (SAS) and self-rating depression scale (SDS), 944 postgraduate students of a military medical university were investigated to analyze their characteristics of anxiety and depression. SPSS 25.0 was used to statistically analyze the collected data.Results:①The positive rates of anxiety and depression were respectively 8.03% and 8.25%. ②The positive rate of anxiety of male postgraduates was significantly higher than that of female postgraduates ( P=0.035). ③The positive rate of anxiety of serviceman students was significantly higher than that of civilian students ( P=0.022). ④There was no statistical difference in the positive rates of anxiety and depression among postgraduates in different areas ( P > 0.05). ⑤The levels of anxiety and depression of left-behind children were significantly higher than those of unleft-behind children ( P=0.000, P=0.018). ⑥The levels of anxiety and depression of postgraduate students were lower than those of undergraduate students ( P=0.000, P=0.002). Conclusion:Under the outbreak of public health emergencies, anxiety and depression occur in the postgraduates. To strengthen the mental health maintenance of postgraduates in military medical university during the outbreak, it is necessary to pay more attention on the mental health of military students, males and who were left-behind children before.
7.Pharmacokinetic study of Noiiglutide injection,INS068 injection and the compound preparation in Chinese healthy subjects
Xiao-Dong XING ; Ji-Gang ZHANG ; Kai SHEN ; Ming-Jian ZHANG ; Yi-Xin ZHA ; Shu-Jing JIN ; Mei XU ; Wen-Yuan XUE ; Xue-Ying DING
The Chinese Journal of Clinical Pharmacology 2023;39(23):3449-3454
Objective To compare the pharmaceutics and drug interactions of noiiglutide injection,INS068 injection,HR17031 Injection,and noiiglutide+INS068 injection in healthy subjects Methods This was a single center,randomized,open-label,4-cycle,4-cohort trial.Healthy subjects were allocated to 4 groups randomly.HR17031(17 U/0.04 mg),INS068(17 U),noliglycopeptide(0.04 mg),and INS068(17 U)combined with noiiglutide(0.04 mg)were injected subcutaneously into the abdomenon on day 1,8,15 and 22 respectively.Venous blood was collected at different timing before and after administration,and the concentrations of noiiglutide in plasma and INS068 in serum were measured by HPLC-MS/MS method.Relevant pharmacokinetic parameters were calculated using the WinNonlin non compartment model.Results In HR17031,INS068,and INS068 combined with noiiglutide groups,the main pharmacokinetic parameters of INS068 in serum were calculated and listed as follows:Cmax were(19.50±4.06),(18.10±4.56)and(18.40±5.81)ng·mL-1,tmax was 12,10 and 8 h,t1/2 was(9.27±1.70),(11.00±2.81)and(11.0±3.18)h,AUC0-twere(505.00±62.20),(498.00±70.50)and(491.00±74.20)ng·mL-1·h.In HR17031,noiiglutide,and INS068 combined with noiiglutide groups,the main pharmacokinetic parameters of noiiglutide in plasma were calculated and listed as follows:Cmax were(3.61±0.82),(4.63±0.87)and(4.54±0.86)ng·mL-1,tmax was all 8.00 h,t1/2 was(10.50±1.61),(9.49±1.40)and(9.55±1.61)h,AUC0-twere(94.30±20.10),(106.00±20.20)and(105.00±19.00)ng·mL-1·h.Conclusion There was no significant difference in bioavailability of INS068 and noiiglutide in HR17031 compared with INS068 and noiiglutide whether combined or used alone.
8.The clinical outcomes of endovenous microwave ablation and radiofrequency ablation for great saphenous varicose veins
Zhiyong CHEN ; Long WANG ; Huan OUYANG ; Xianyu HU ; Yuan HONG ; Bo LIU ; Yi LIU ; Xu ZHANG ; Binshan ZHA
Chinese Journal of General Surgery 2023;38(10):765-771
Objective:To compare the efficacy of intraluminal microwave ablation with radiofrequency ablation in the treatment of varicose veins of the lower extremities.Methods:The clinical data of 520 patients (522 affected limbs) who underwent lower extremity varicose vein surgery at the Department of Vascular Surgery of the First Affiliated Hospital of Anhui Medical University from Jun 2021 to Sep 2022 were collected. Patients were divided into endovenous microwave ablation group (EMWA group, n = 201) and radiofrequency ablation group (RFA group, n = 321). Follow-up was performed at 1 week, 1 , 6 and 12 months after surgery. The primary efficacy endpoint was the occlusion rate of the treated segment vein, the primary safety endpoint was the incidence of surgery-related and/or device-related complications, and the secondary endpoints were the venous clinical severity score (VCSS) and chronic venous insufficiency quality of life questionnaire (CIVIQ) scores at follow-up. Results:The technique success rate and the occlusion rate of the affected segment vein was 100% in both groups evaluated one week after surgery; Six and 12 months after surgery, the occlusion rate in the RFA group was 98.9%, and that in the EMWA group was 99.3% and respectively 97.8%, 97.2% ,without statically significant difference.During the follow-up period, there were no cases of reoperation due to vein recanalization. no serious events such as deep vein thrombosis, pulmonary embolism or death occurred in either group. The incidence of adverse events (induration, ecchymosis, skin burn, incision infection, limb numbness, hematoma, thrombotic superficial phlebitis, endovenous heat induced thrombosis, etc.) in both groups was compared, and the difference was not statistically significant. VCSS and CIVIQ scores improved significantly in both groups at 1 ,6 and 12 months after treatment, and the difference was statistically significant(all P < 0.01). Conclusion:EMWA and RFA have the advantages of simple operation, good clinical efficacy and high degree of improvement in quality of life.
9.Effect of Mirabegron combined with Silodosin on detrusor hyperactivity with impaired contractile
Huiling CONG ; Limin LIAO ; Guang FU ; Lihua ZHA ; Yuqi YANG ; Yizheng WANG ; Xing LI ; Juan WU ; Yi GAO ; Huafang JING
Chinese Journal of Rehabilitation Theory and Practice 2022;28(4):473-478
Objective To observe the clinical effect of Mirabegron combined with Silodosin on detrusor hyperactivity with impaired contractile (DHIC).Methods From September, 2019 to December, 2021, 40 patients with DHIC in the Department of Urology of Beijing Bo'ai Hospital were selected and randomly divided into control group and experimental group, with 20 cases in each group. The control group took Silodosin only, and the experimental group took Mirabegron in addition, for four weeks. The urinary diary, residual urine volume, Overactive Bladder Symptom Score (OABSS) and quality of life (QOL) score were compared before and after treatment.Results A total of 18 patients in the control group and 19 in the experimental group finished the trial. After treatment, the number of night urination per day, the residual urine volume and QOL score improved in the control group (P<0.01); the number of urination per 24 hours, the number of night urination per day, the volume per urination, the residual urine volume, the daily urgency score, the OABSS score and QOL score improved in the experimental group (P<0.01). The number decrease of urination per 24 hours, the volume decrease of per urination, the daily urgency score decrease, the OABSS score decrease and QOL score decrease were more in the experimental group than in the control group (P<0.01). The adverse reactions included palpitations, increased heart rate, dyspareunia, increased blood pressure, gastric discomfort, postural hypotension, and retrograde ejaculation, and there was no significant difference between two groups (P > 0.05).Conclusion The efficacy of Mirabellone combined with Silodosin on DHIC is better than Silodosin only, and there was no significant increase in drug-related adverse effects.
10.Augmentation uretero-enterocystoplasty for lower urinary tract dysfunction: a long-term retrospective efficacy study
Limin LIAO ; Runtian LUO ; Zhonghan ZHOU ; Guang FU ; Guoqing CHEN ; Fan ZHANG ; Xing LI ; Zongsheng XIONG ; Yanhe JU ; Huiling CONG ; Yiming WANG ; Lihua ZHA ; Juan WU ; Yi GAO ; Huafang JING
Chinese Journal of Urology 2022;43(9):651-658
Objective:To investigate the long-term efficacy and complications of augmentation uretero-enterocystoplasty (AUEC).Methods:The clinical data of 262 patients with lower urinary tract dysfunction who underwent AUEC at our center from January 2003 to June 2022 were analyzed retrospectively. There were 193 males and 69 females, the median age was 24 (4, 67) years, the median disease duration was 12.0 (0.2, 56.0) years and the preoperative creatinine was 91.5 (68.1, 140.0) μmol/L. 320 ureters had high-grade UUTD, 216 ureters had VUR, 14 of which had low-pressure reflux.The number of low-grade VUR ureter was 22 (10.2%) and the number of high-grade VUR ureter was 194 (89.8%). Video-urodynamics showed that the maximum bladder capacity was 102 (47, 209) ml, the maximum detrusor pressure was 33.0 (15.5, 50.5) cmH 2O, and the bladder compliance was 6.4 (3.0, 12.3) ml/cmH 2O. All patients underwent AUEC. The surgical method is to cut a segment of sigmoid colon, open the sigmoid colon along the mesenteric margin, fold and suture it into " U" or " S" shaped intestinal mesh according to the principle of " detubulization" . At the same time, perform ureteroplasty and replanting, and then anastomosis the intestinal mesh with the opened bladder flap to form an expanded new bladder. Follow-up was performed via outpatient clinic or telephone. The creatinine, maximum bladder capacity, maximum detrusor pressure, bladder compliance, ureteral reflux and upper urinary tract dilatation were compared preoperatively and postoperatively. The postoperative complications were also evaluated. Results:The median follow-up time was 57.4 (4, 151) months after surgery. At 1-3 months after surgery, the maximum bladder capacity and bladder compliance increased to 303.9% and 189.9% of the preoperative level, and the maximum detrusor pressure decreased to 63.6% of the preoperative level. At 6-10 years after surgery, the maximum bladder capacity and bladder compliance increased to 490.2% and 627.9% and the maximum detrusor pressure decreased to 25.8% of the preoperative level. The UUTD of the patients was significantly reduced after surgery. The number of the high grade UUTD decreased to 116 (116/398, 29.2%) at 1-3 months and 51 (51/274, 18.6%) at 4-6 months. At 6-10 years, the number of the high-grade UUTD decreased to 4 (4/76, 5.3%) ( P<0.001), which was significantly lower than that before operation. The VUR was significantly relieved after operation, and 393 ureters had no VUR at 1-3 months, accounting for 97.8% (393/402) of the total ureters. Sustained remission of VUR was observed during follow-up. 73 ureters had no VUR at 6-10 years, accounting for 96.1% (73/76) of total ureters ( P<0.001). Patients' creatinine decreased to 79.0 (65.0-128.2) μmol/L at 1-3 months postoperatively, with a downward trend but no statistical difference, and creatinine levels were not significantly elevated at any postoperative time point compared with preoperative levels ( P>0.05). Postoperative complications included metabolic acidosis in 26 cases (9.9%), vesicoureteral anastomosis stenosis in 15 cases (5.7%), recurrent urinary tract infection in 16 cases (6.1%), and urinary calculi in 20 cases (7.6%), and intestinal obstruction requiring laparotomy in 8 cases (3.1%), all of them could be improved after treatments. Conclusions:AUEC is a safe and effective method for treating high-grade VUR or VUR with impaired anti-reflux mechanism, high-grade UUTD or UUTD with ureteral or vesicoureteral junction obstruction, and all of the complications can be improved after treatment. This technique can increase the bladder capacity and compliance, reconstruct the anti-reflux mechanism, and release upper urinary tract obstruction. It may play an important role in stabilizing and protecting the residual renal function from further deterioration.


Result Analysis
Print
Save
E-mail