1.The introduction on the revised standards of pharmaceutical excipients in the Chinese Pharmacopoeia 2025 Edition
CHEN Lei ; LUI Yanming ; YUAN Yaozuo ; CHEN Ying ; DAI Hong ; ZHANG Jun ; MA Shuangcheng
Drug Standards of China 2025;26(1):051-057
According to the work goals and tasks determined by edition outline of the Chinese Pharmacopoeia 2025 Edition, the Chinese Pharmacopoeia 2025 has been completed. Among them, 52 new pharmaceutical excipients monographs have been added, and the total number has reached 387. 245 pharmaceutical excipients monographs have been revised, of which 109 monographs have only textual revisions and 136 monographs have substantive revisions. This article focuses on the general framework and the main characteristics of the standards of pharmaceutical excipients in the Chinese Pharmacopoeia 2025, which can contribute to accurately understand and utilize the standards in Chinese Pharmacopoeia.
2.Comparison of SEC-RI-MALLS and SEC-RID methods for determining molecular weight and molecular weight distribution of PLGA
WANG Baocheng ; ZHANG Xiaoyan ; ZHOU Xiaohua ; ZHAO Xun ; MA Congyu ; GAO Zhengsong ; SHI Haiwei ; YUAN Yaozuo ; HANG Taijun
Drug Standards of China 2025;26(1):110-116
Objective: To establish a method for determining the molecular weight and molecular weight distribution of Poly(Lactide-co-Glycolide Acid) (PLGA) using Size Exclusion Chromatography-Refractive Index-Multiangle Laser Light Scattering (SEC-RI-MALLS) and Size Exclusion Chromatography-Refractive Index (SEC-RID), and to compare the results obtained from these two methods.
Methods: For SEC-RI-MALLS, tetrahydrofuran was used as the mobile phase, Shodex GPC KF-803L was employed as the chromatographic column with a flow rate of 1 mL·min-1, column temperature at 30 ℃, and an injection volume of 100 μL. For SEC-RID, tetrahydrofuran was also used as the mobile phase, Agilent PLgel 5 μm MIXD-D was used as the chromatographic column with a flow rate of 1 mL·min-1, column temperature at 30 ℃, differential detector temperature at 35 ℃, and an injection volume of 20 μL. The molecular weight and molecular weight distribution were calculated using Agilent’s GPC software. The newly established methods were validated methodologically, and the molecular weight and molecular weight distribution of 13 batches of samples were determined.
Results: The precision, accuracy, stability, and repeatability tests for SEC-RI-MALLS showed RSD values of 1.35%, 1.58%, 1.53%, and 1.26%, respectively. The SEC-RID method exhibited good linearity (r=0.999 9), with RSD values for precision, accuracy, stability, and repeatability tests (n=6) of 2.05%, 1.62%, 1.30%, and 2.97%, respectively. The results obtained from SEC-RI-MALLS were lower than those from SEC-RID, and the molecular weight distribution coefficient was smaller, but the results from the paired T-test performed with the value measured by SEC-RID method and the value measured by SEC-RI-MALLS method multiplied a conversion coefficient of 1.5 showed no significant difference between the two methods.
Conclusion: Both methods are stable and reliable, and can be used for the determination of PLGA molecular weight and molecular weight distribution based on the specific situations.
3.Analysis of the causes for abnormal dissolution of lansoprazole enteric-coated tablets by multiple techniques and different dimensions
Wenxin LIU ; Yan LI ; Yaozuo YUAN ; Huanhuan JIA ; Minhui CHEN ; Jinlin ZHANG
Journal of China Pharmaceutical University 2024;55(2):224-229
Abstract: This study aims to find out the causes for the dissolution of unqualified samples found during evaluation sampling of lansoprazole enteric-coated preparations by the laser infrared imaging system and orbitrap high resolution mass spectrometry, with suggestions for improvement. Lansoprazole enteric-coated preparations were tested by current standard, the dissolution of a batch of samples was below the limit and other items were in line with the standard. Considering that this product is unstable to acid and alkali, the following exploratory experiments were designed from different dimensions, based on the conclusion of the unannounced inspection of the company, to explore the reasons for the unqualified batch, including the influence of high-temperature and high-humidity storage environment on the key quality properties of the sample, the influence of 2-hour acid resistance test on dissolution result, the imaging of the core and the measure of coating layer thickness, the optimization of chromatographic conditions of related substances, and the analysis of the source of impurities. It was found that improper storage in circulation and poor coating process caused the low dissolution of this batch: the high-temperature and high-humidity storage environment possible in the circulation process led to the decreasing efficacy of disintegrating agent in the samples and thus the difficulty to release the active pharmaceutical ingredient fully; the coating solution could not be uniformly sprayed on the core, resulting in thin isolation layer and different thickness, which then affected the protection of the main drug against acid degradation. The above two reasons together resulted in unqualified dissolution of this batch. The overall quality of lansoprazole enteric-soluble preparation is good, but the formulation and process in some companies need to be optimized; and the temperature and humidity in the circulation process need to be controlled in strict accordance with the regulations.
4.Discrimination of polysorbate 20 by high-performance liquid chromatography-charged aerosol detection and characterization for components by expanding compound database and library
Wang SHI-QI ; Zhao XUN ; Zhang LI-JUN ; Zhao YUE-MEI ; Chen LEI ; Zhang JIN-LIN ; Wang BAO-CHENG ; Tang SHENG ; Yuan TOM ; Yuan YAOZUO ; Zhang MEI ; Lee Kee HIAN ; Shi HAI-WEI
Journal of Pharmaceutical Analysis 2024;14(5):722-732
Analyzing polysorbate 20(PS20)composition and the impact of each component on stability and safety is crucial due to formulation variations and individual tolerance.The similar structures and polarities of PS20 components make accurate separation,identification,and quantification challenging.In this work,a high-resolution quantitative method was developed using single-dimensional high-performance liquid chromatography(HPLC)with charged aerosol detection(CAD)to separate 18 key components with multiple esters.The separated components were characterized by ultra-high-performance liquid chro-matography-quadrupole time-of-flight mass spectrometry(UHPLC-Q-TOF-MS)with an identical gradient as the HPLC-CAD analysis.The polysorbate compound database and library were expanded over 7-time compared to the commercial database.The method investigated differences in PS20 samples from various origins and grades for different dosage forms to evaluate the composition-process relationship.UHPLC-Q-TOF-MS identified 1329 to 1511 compounds in 4 batches of PS20 from different sources.The method observed the impact of 4 degradation conditions on peak components,identifying stable components and their tendencies to change.HPLC-CAD and UHPLC-Q-TOF-MS results provided insights into fingerprint differences,distinguishing quasi products.
5.Introduction on the standard of pharmaceutical excipients in the first supplement of the Chinese Pharmacopoeia 2020
Lei CHEN ; Ying CHEN ; Yanming LIU ; Yaozuo YUAN ; Hong DAI ; Jiasheng TU
Drug Standards of China 2024;25(2):168-175
The first supplement of the Pharmacopoeia of the People's Republic of China 2020 Edition will be imple-mented on March 12,2024.It plays an important role in connecting link between the preceding and the following.Among them,11 new pharmaceutical excipients monographs have been added and 46 monographs have been revised.This formulation and revision of pharmaceutical excipients standards are based on the concept of risk man-agement and the full lifecycle management and focuse on ensuring the clinical safety and effectiveness of drugs,the evaluation of critical quality attributes on pharmaceutical excipients is highlighted in the standard-making process,and functional-related characteristics(FRCs)and safety indicators are included.Moreover,the excipient standards have emphasized the concept of international pharmacopeia harmonization and green environmental protection and strengthened the standardization and operability.This article focuses on the general framework and the main charac-teristics of the standards of pharmaceutical excipients in the first supplement of the Chinese Pharmacopoeia 2020,which can contribute to accurately understand and utilize the standards in the Chinese Pharmacopoeia.
6.Investigation on the rapid determination of lactose content by polarimetry
Haodong ZHAO ; Xiaohua ZHOU ; Xun ZHAO ; Lin ZHU ; Haiwei SHI ; Qing HUANG ; Yaozuo YUAN
Drug Standards of China 2024;25(5):512-516
Objective:To established a rapid method for the determination of lactose(C12 H22 O11)content.Methods:The specific rotation([α]20D)of pure lactose was measured with lactose extract product,and the correc-tion coefficient was calculated.The measured rotatory value of the sample was multiplied by the correction coeffi-cient to obtain the mass(g)of lactose in the test product,and the lactose content was calculated.The equivalence of the newly established polarimetric method and the legal test method(HPLC-RID method)for the determination of lactose content was studied.Results:The linear relation of established method was excellent with the range of 0.05-0.20 g·mL-1(r=1.000 0)and the method also had good reproducibility(RSD=0.07%(n=6)).The lactose content of 141 batches samples measured by polarimetry was compared with the results determined by official analytical procedure,and the results showed the relative deviation between the same batches was less than 1.0%.The results of one-way ANOVA also showed that there was no significant difference between two groups(Sig.>0.05).Conclusion:The performance of polarimetry is comparable to HPLC-RID in the Chinese Pharma-copoeia 2020 Vol Ⅳ.Meanwhile,the polarimetry can reduce the test cost,shorten the test time and meet the requirements of the quality control.
7.Impurity spectra of lansoprazole enteric-coated preparations by high performance liquid chromatography-high resolution orbital trap mass spectrometry
Yan LI ; Huanhuan JIA ; Qing HUANG ; Yaozuo YUAN ; Minhui CHEN ; Jinlin ZHANG
Journal of China Pharmaceutical University 2023;54(5):577-585
Using high performance liquid chromatography and high resolution orbital trap mass spectrometry, a two-dimensional online desalting detection method was established to determine the structure of the impurities detected under the official testing conditions of lansoprazole enteric solution preparation, and a chromatographic method compatible with mass spectrometry was established to determine and presume the structure of the impurities that could not be separated by the the official testing method.The identification of impurity was to presume its structure according to the presence of impurity reference product, so as to investigate the difference of impurity spectrum of products from different manufacturers.The one-dimensional chromatographic conditions for the 2D online desalting method were the same as those in China Pharmacopoeia (2020) under relevant substances.Two-dimensional chromatography was performed on a Waters C18 T3 column (2.1 mm × 100 mm, 1.7 μm) with 0.1% formic acid in water-acetonitrile mobile phase and gradient elution.The chromatographic conditions for the compatible mass spectra were based on an Agilent Extend C18 (4.6 mm × 150 mm, 5 μm) column with mobile phase A: 25 mmol/L ammonium acetate and B: 25 mmol/L ammonium acetate-acetonitrile (1∶4) [pH adjusted to 6.5 with glacial acetic acid], with gradient elution. Nine impurities were detected by two-dimensional online desalting method, with 5 known impurities (A-E) and 4 unknown ones.14 impurities were detected by the compatible mass spectrometry method, with 9 unknown impurities (4 consistent with the results of two-dimensional online desalting method, and 5 newly detected).The structures and sources of the unknown impurities were deduced.The two detection methods of lansoprazole preparation by high-performance liquid chromatography-high resolution orbital trap mass spectrometry have guiding significance for quality control and process evaluation.
8.Chromatographic fingerprint and quality consistency of colistimethate sodium
Xuan LI ; Minwen HUANG ; Jie ZHOU ; Yaozuo YUAN ; Taijun HANG
Journal of China Pharmaceutical University 2023;54(6):749-756
The UPLC fingerprint of colistimethate sodium was established for the study of quality consistency.The chromatographic column was Acquity UPLC? Peptide CSH C18 (2.1 mm × 150 mm, 1.7 μm).The mobile phase A was phosphate buffer-acetonitrile (19∶1), and the mobile phase B was phosphate buffer-acetonitrile (1∶1).The mobile phase was in gradient elution at a flow rate of 0.3 mL/min.The column temperature was set at 30 °C and the detection wavelength was 210 nm.The similarity of the fingerprints was analyzed with the Similarity Evaluation System for Chromatographic Fingerprint of Tradition Chinese Medicine (Version 2012) in combination with content determination of multiple index components to evaluate the quality consistency of imported and domestic bulk drugs.The result showed that both the original and generic bulk drugs met the specified limit requirements in the European Pharmacopoeia standards, and that their UPLC fingerprints were highly similar, indicating that the quality of the two substances was consistent.Establishing a fingerprint for similarity evaluation and combining it with the results of indicator component content determination as a comprehensive evaluation method for the study of drug quality consistency of complex components has the characteristics of fast, accurate, and comprehensive, which is helpful for drug quality evaluation and provides ideas for the evaluation of antibiotic quality consistency of complex components.
9.A method for rapid analysis of polysorbate 80 components
Ying ZHOU ; Xun ZHAO ; Nan HU ; Baocheng WANG ; Yaozuo YUAN
Journal of China Pharmaceutical University 2022;53(2):192-199
Due to the complex components of polysorbate 80, analysis is time-consuming and labor-intensive, so there is an urgent need to find a method for rapid analysis of polysorbate 80 components.In this study, 10 batches of samples collected from 3 domestic and foreign enterprises were analyzed by UHPLC-HRMS, with the being further results were analyzed by the ExcipientProfiler software and supplemented by the extended database.The results showed that the ExcipientProfiler software could quickly identify the [M+Na]+ peak in the mass spectrogram, and obtain the information of component distribution, the numbers of components and the degree of polymerization of the sample.Meanwhile, the numbers of components obtained by the ExcipientProfiler software could be used to distinguish the injection grade samples from the ordinary grade samples by systematic clustering analysis.In addition, it was found through further supplement that the sample contained other fatty acid ester components by manually searching the relevant extended database.The polyoxyethylene sorbitan tetraoleate components were found in the sample according to the analysis of mass spectrum data.Therefore, although this method is fast and simple, it is necessary to add polyoxyethylene sorbitan tetraoleate components and other fatty acid ester components to further supplement the information in the ExcipientProfiler software, so that it can be better used for the analysis of polysorbate 80.
10.Determination of the content and related substances of neomycin sulfate by HPLC combined with pulsed amperometric detection
Qian ZHANG ; Minwen HUANG ; Wang FANG ; Mei ZHANG ; Taijun HANG ; Yaozuo YUAN
Journal of China Pharmaceutical University 2019;50(2):193-199
A novel method was developed for the content assay and related substances determination of neomycin sulfate by high performance liquid chromatography combined with pulsed amperometric detection(HPLC-PAD). The HPLC was performed on Thermo AcclaimTMAmG C18(4. 6 mm×150 mm, 3 μm). The mobile phase consisted of aqueous solution with 2% trifluoroacetic acid containing 0. 01% pentafluoropropionic acid and 0. 6%NaOH. The pulsed amperometric detector was operated with aquadruple-potential waveform for the detection. Neomycin B, Neomycin C and thirteen related substances were adequately separated by the established HPLC conditions. The limits of detection(LOD)and quantification(LOQ)of neomycin B and neomycin C were both 1. 75 ng and 3. 5 ng, respectively. Good linearities of neomycin B and neomycin C were found in their respective ranges which their correlation coefficients were greater than 0. 998 5. The established method is characterized by high specificity, sensitivity and wide range of linearity which has a good application prospect and provides the basis for improving the standard and quality control of neomycin sulfate.

Result Analysis
Print
Save
E-mail