1.A Case Report of Pachydermoperiostosis by Multidisciplinary Diagnosis and Treatment
Jie ZHANG ; Yan ZHANG ; Li HUO ; Ke LYU ; Tao WANG ; Ze'nan XIA ; Xiao LONG ; Kexin XU ; Nan WU ; Bo YANG ; Weibo XIA ; Rongrong HU ; Limeng CHEN ; Ji LI ; Xia HONG ; Yan ZHANG ; Yagang ZUO
JOURNAL OF RARE DISEASES 2025;4(1):75-82
A 20-year-old male patient presented to the Department of Dermatology of Peking Union Medical College Hospital with complaints of an 8-year history of facial scarring, swelling of the lower limbs, and a 4-year history of scalp thickening. Physical examination showed thickening furrowing wrinkling of the skin on the face and behind the ears, ciliary body hirsutism, blepharoptosis, and cutis verticis gyrate. Both lower limbs were swollen, especially the knees and ankles. The skin of the palms and soles of the feet was keratinized and thickened. Laboratory examination using bone and joint X-ray showed periostosis of the proximal middle phalanges and metacarpals of both hands, distal ulna and radius, tibia and fibula, distal femurs, and metatarsals.Genetic testing revealed two variants in
2.Signal interference between drugs and metabolites in LC-ESI-MS quantitative analysis and its evaluation strategy
Jiang FULIN ; Liu JINGYU ; Li YAGANG ; Lu ZIHAN ; Liu QIAN ; Xing YUNHUI ; Zhu JANSHON ; Huang MIN ; Zhong GUOPING
Journal of Pharmaceutical Analysis 2024;14(7):1024-1034
Liquid chromatography-electrospray ionization tandem mass spectrometry(LC-ESI-MS)is a widely utilized technique for in vivo pharmaceutical analysis.Ionization interference within electrospray ion source,occurring between drugs and metabolites,can lead to signal variations,potentially compromising quantitative accuracy.Currently,method validation often overlooks this type of signal interference,which may result in systematic errors in quantitative results without matrix-matched calibration.In this study,we conducted an investigation using ten different groups of drugs and their corresponding me-tabolites across three LC-ESI-MS systems to assess the prevalence of signal interference.Such in-terferences can potentially cause or enhance nonlinearity in the calibration curves of drugs and metabolites,thereby altering the relationship between analyte response and concentration for quanti-fication.Finally,we established an evaluation scheme through a step-by-step dilution assay and employed three resolution methods:chromatographic separation,dilution,and stable labeled isotope internal standards correction.The above strategies were integrated into the method establishment process to improve quantitative accuracy.
3.A case report of dermatitis herpetiformis with positive gluten-sensitive intestinal disease autoantibodies
Xuzhen QIN ; Sizhe LI ; Feng LI ; Yagang ZUO ; Yongzhe LI
Chinese Journal of Laboratory Medicine 2022;45(9):977-979
A middle-aged male patient initially appeared scattered erythema with pruritus all over the body without obvious cause. According to the skin manifestations of the patient, combined with pathological diagnosis, direct immunofluorescence examination, and different serum autoantibody spectrum, the diagnosis and differential diagnosis of the patient was made by clinicians. The diagnosis of dermatitis herpetiformis was confirmed by the use of autoantibodies in the absence of any apparent history of pasta discomfort. With targeted treatment, the patient′s symptoms and laboratory indicators improved significantly.
4.Action mechanisms of thymic stromal lymphopoietin in various skin diseases
Xinxing JIN ; Sizhe LI ; Yagang ZUO
Chinese Journal of Dermatology 2021;54(10):915-919
Thymic stromal lymphopoietin (TSLP) , a cytokine similar to interleukin-7 (IL-7) , can promote the differentiation and proliferation of a variety of cells, promote the secretion of Th2 cytokines by these cells, and plays an important role in the immune system. In recent years, abnormal expression of TSLP has been found in many skin diseases, and its level is also related to the severity of some skin diseases, suggesting that TSLP may be a potential target for the treatment of various skin diseases. This review summarizes recent research progress in the role of TSLP in the occurrence and development of various skin diseases, including inflammatory diseases, immune diseases, genetic diseases and tumors, and provides a basis and some ideas for the diagnosis and treatment of related diseases.
5.Detection of eosinophil cationic protein in sera and blister fluids of patients with bullous pemphigoid
Xiaolei GE ; Sizhe LI ; Yagang ZUO
Chinese Journal of Dermatology 2020;53(12):1008-1011
Objective:To investigate the relationship of eosinophil cationic protein (ECP) levels in sera and blister fluids with bullous pemphigoid (BP) .Methods:From January 2012 to October 2019, 40 patients with newly diagnosed BP and 40 healthy individuals were enrolled from Department of Dermatology, Peking Union Medical College Hospital, and serum ECP levels were detected by enzyme-linked immunosorbent assay. Meanwhile, another 33 patients with newly diagnosed BP and 41 patients with non-autoimmune bullous diseases were enrolled, and the ECP level was detected in blister fluids by enzyme-linked immunosorbent assay. Pathological sections of skin lesions of 1 patient with BP and 1 with contact dermatitis were subjected to immunohistochemical staining for ECP. Normally distributed data were compared between 2 groups by using t test or t′ test, while enumeration data were compared by using chi-square test. Pearson′s correlation coefficient was used to analyze the relationship between serum levels of ECP and proportions of peripheral blood eosinophils in patients with BP. Results:The serum level of ECP was significantly higher in the BP group (116.9 ± 19.3 ng/L) than in the healthy control group (93.3 ± 15.9 ng/L, t = 5.96, P<0.001) , and the blister fluid level of ECP was also significantly higher in the BP group (665.8 ± 189.0 ng/L) than in the non-autoimmune bullous disease group (547.5 ± 240.6 ng/L, t = 2.31, P = 0.02) . Immunohistochemical study showed more brown-yellow particles in the cytoplasm of ECP-positive cells in the BP group than in the contact dermatitis group. There was no significant correlation between the serum level of ECP and proportion of peripheral blood eosinophils in the BP patients ( r = -0.15, P = 0.35) . Conclusion:The levels of ECP in the sera and blister fluids markedly increased in the patients with BP, and blister fluid levels of ECP were much higher than serum levels of ECP, suggesting that ECP may be involved in the occurrence of BP.
6.There is no correlation between the serum level of interleukin-21 and bullous pemphigoid
Sizhe LI ; Tianmeng YAN ; Li LI ; Hongzhong JIN ; Yagang ZUO
Chinese Journal of Dermatology 2018;51(8):595-596
Objective To investigate the correlations of the serum level of interleukin-21 (IL-21) with anti-BP 180 antibodies,peripheral eosinophil level,bullous pemphigoid disease area index (BPDAI)in patients with bullous pemphigoid (BP).Methods A total of 31 patients with bullous pemphigoid and 31 healthy controls were enrolled into this study.Blood samples were collected from all the subjects,and enzyme-linked immunosorbent assay (ELISA) was performed to detect the serum level of IL-21 and serum titer of anti-BP180 antibodies.BPDAI was assessed among 13 patients,and the correlation of the IL-21 level with anti-BP180 antibody titers,eosinophil count and BPDAI were analyzed.Results No significant difference in the serum level of IL-21 was observed between the patients (M [P25-P75]:255.28 [156.19-361.59] ng/L) and healthy controls (150.47 [72.4-268.73] ng/L,P =0.14).There was no correlation between the serum level of IL-21 and serum titer of anti-BP180 antibodies (82.98 [26.82-132.92] U/ml,rs =0.18,P =0.332).Among the 27 BP patients who underwent blood cell count,no correlation was found between the serum levels of IL-21 and whole-blood eosinophil counts (rs =0.104,P =0.606).Among the 13 BP patients who underwent assessment of BPDAI,there was no correlation between the serum levels of IL-21 and BPDAI scores (rs =0.233,P =0.464).Conclusion The IL-21 level is uncorrelated with anti-BP 180 antibody level,peripheral eosinophil level or BPDAI in patients with BP.
7.Correlation between ATF5 protein expression level and drug sensitivity of gastric cancer AGS cells
Jie LIU ; Yagang ZHAO ; Hongwu ZHU ; Liping LI
The Journal of Practical Medicine 2017;33(7):1061-1065
Objective To explore the correlation between ATF5 protein expression level and drug sensitivity of gastric cancer AGS cells.Methods We established the high,middle and low ATF5 expression groups by transfecting the AGS cells with ATF5 pcDNA3.1 plasmid,ATF5 siRNA and empty plasmid using the liposome transfection technique.Then we detected the expression of the ATF5 protein of the 3 groups using the Western Blot.The drug sensitivity of AGS cells in 3 groups to paclitaxel and cisplatin was detected using the MTT experiments and plate clone formation experiments then the correlation between ATF5 protein expression level and drug sensitivity of gastric cancer AGS cells was analyzed.Results With the effect of paclitaxel or cisplatin on AGS cells in 3 groups,the surviving fraction and the IC50 of high ATF5 expression group were higher than those of control group,which indicated statistical significance (all P < 0.05);while the surviving fraction and the IC50 of low ATF5 expression group were lower than those of control group (all P < 0.05,P cisplatin =0.00,P paclitaxel =0.002).We found that cell clone formation of AGS cells to paclitaxel and cisplatin was significantly increased after the transfection with ATF5 protein plasmid and decreased after transfection with ATF5 siRNA plasmid (all P < 0.05).Conclusion The expression of ATF5 protein is related to the drug sensitivity of gastric cancer AGS cells that upregulation of ATF5 protein expression can decrease the drug sensitivity of AGS cells to paclitaxel and cisplatin in gastric cancer.
8.Prognostic accuracy of the SCORTEN scoring system in patients with toxic epidermal necrolysis or Stevens-Johnson syndrome
Yulu WANG ; Yagang ZUO ; Jie LIU ; Yuehua LIU ; Li LI ; Qiuning SUN ; Hongzhong JIN
Chinese Journal of Dermatology 2016;49(9):651-653
Objective To evaluate the prognostic accuracy of the score of toxic epidermal necrolysis (SCORTEN) scoring system in patients with toxic epidermal necrolysis (TEN) or Stevens-Johnson syndrome (SJS).Methods Clinical data were collected from 39 patients with SJS/TEN hospitalized in Peking Union Medical College Hospital during April 1992 and March 2014,and retrospectively analyzed.Among the 39 patients,13 had died,and the other 26 patients,who were matched to the dead patients in a ratio of 2:1 for age,all had a definite diagnosis and were discharged with improved conditions.The SCORTEN scoring system was used to evaluate the 39 patients with SJS/TEN and calculate expected mortality.The expected mortality and actual mortality were compared between different groups stratified by age in the 39 patients.The receiver operating characteristic (ROC) curve was drawn to assess the prognostic accuracy of the SCORTEN scoring system.Results According to the SCORTEN scoring system,15 out of the 39 patients scored 1 point,14 scored 2 points,6 scored 3 points,and 4 scored 4 points.The total number of expected deaths was 6.808,while that of actual deaths was 13.There was no significant difference between the expected mortality and actual mortality in every SCORTEN score-based group.The area under curve (AUC) was 0.832 8,indicating a good predictive ability of the SCORTEN scoring system.Conclusion The SCORTEN scoring system can predict mortality in TEN/SJS patients at early stage.
9.Comparison of the Performance between the Mandarin Version of HHIE-S and Single Question in the Hearing Screening in Old Adults
Yue WANG ; Lingyan MO ; Zhongwei ZHENG ; Yu QI ; Yagang LI ; Xiuchang LI ; Jie YANG
Journal of Audiology and Speech Pathology 2016;24(5):425-429
Objective To compare the performance of Mandarin screening version of hearing handicap inven-tory in elderly (HHIE-S)and the single question of hearing loss in the hearing screening in the old adults.Methods A total of 570 participants,aged from 50~85 years,of native Mandarin speakers were tested with standard pure tone audiometry (PTA),HHIE-S and single questionAre you now having difficulty in hearing?.HHIE-S>8 was taken as an indicator of hearing handicap.Sensitivity,specificity,negative predictive values and positive predic-tive values of both HHIE-S and single question inquiry when 0.5~4 kHz PTA average > 25 dB,>40 dB and >60 dB were compared.Results The prevalence was 83.9% (478)measured by PTA.The prevalence was 55.3%and 52.5% for HHIE-S and positive answer for single question,respectively.The sensitivity of HHIE-S when the participants grouped with 0.5~4 kHz PTA average > 25 dB,>40 dB and > 60 dB was 61%,85% and 96%, respectively,whereas the sensitivity of single question of the above 3 conditions was 58%,81% and 100%,respec-tively.The specificity of HHIE-S decreased with greater hearing loss.It was 72%,88% and 47% respectively for HHIE-S and 75%,61% and 50% for the single question.There was no significant difference either for sensitivity and specificity between the HHIE-S and the single question.Conclusion Both the Mandarin version of HHIE-S and single question are effective in the hearing screening of old adults.Depending on the purpose and availability of resources,one or both of them can be adopted.
10.Determination of Ferrous Succinate Tablets by Ion Chromatography
Jihua LIU ; Ying WANG ; Yi LIU ; Zhiyuan LI ; Yagang FAN
China Pharmacist 2016;19(6):1194-1195
Objective:To establish a method to determine ferrous succinate in ferrous succinate tablets .Methods:Ion chromatog-raphy was performed on an IonPac AG19(4 mm ×250 mm)anion exchange chromatography column with a guard column of Ion Pac TM AG19( 4 mm ×50 mm);30.00 mmol· L-1 KOH was used as the isocratic eluent at a flow rate of 1.00 ml· min-1 with suppressed conductivity detection ( Curb:75 mA) at the temperature of 30℃.The sample size was 25 μl .Results:The linear range of succinic acid was 2.005 1-25.064 0μg· ml-1(r=0.999 5).The detection limit and quantitation limit was 0.12ng and 0.42ng, respectively. The recovery was 101.45%(RSD=0.43%, n=6).Conclusion:The method is simple, rapid, accurate, reproducible and sensitive , and can be used to determine the ferrous succinate content in ferrous succinate tablets .

Result Analysis
Print
Save
E-mail