1.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
		                        		
		                        			 PURPOSE:
		                        			This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements. 
		                        		
		                        			MATERIALS AND METHODS:
		                        			Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05. 
		                        		
		                        			RESULTS:
		                        			The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05). 
		                        		
		                        			CONCLUSION
		                        			Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored. 
		                        		
		                        		
		                        		
		                        	
2.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
		                        		
		                        			 PURPOSE:
		                        			This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements. 
		                        		
		                        			MATERIALS AND METHODS:
		                        			Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05. 
		                        		
		                        			RESULTS:
		                        			The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05). 
		                        		
		                        			CONCLUSION
		                        			Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored. 
		                        		
		                        		
		                        		
		                        	
3.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
		                        		
		                        			 PURPOSE:
		                        			This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements. 
		                        		
		                        			MATERIALS AND METHODS:
		                        			Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05. 
		                        		
		                        			RESULTS:
		                        			The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05). 
		                        		
		                        			CONCLUSION
		                        			Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored. 
		                        		
		                        		
		                        		
		                        	
4.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
		                        		
		                        			 PURPOSE:
		                        			This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements. 
		                        		
		                        			MATERIALS AND METHODS:
		                        			Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05. 
		                        		
		                        			RESULTS:
		                        			The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05). 
		                        		
		                        			CONCLUSION
		                        			Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored. 
		                        		
		                        		
		                        		
		                        	
5.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
		                        		
		                        			 PURPOSE:
		                        			This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements. 
		                        		
		                        			MATERIALS AND METHODS:
		                        			Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05. 
		                        		
		                        			RESULTS:
		                        			The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05). 
		                        		
		                        			CONCLUSION
		                        			Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored. 
		                        		
		                        		
		                        		
		                        	
6.Effect of the staging comprehensive treatment with acupuncture-moxibustion on Bell's facial palsy in the acute stage.
Jiajie CHEN ; Haiping SHI ; Wanli GAO ; Xiaowei LI ; Yuling SHU ; Yongzhe WANG ; Binjian JIANG ; Jun YANG ; Pin WANG
Chinese Acupuncture & Moxibustion 2024;44(1):51-56
		                        		
		                        			OBJECTIVES:
		                        			To compare the clinical effect on Bell's facial palsy in the acute stage between the staging comprehensive treatment with acupuncture-moxibustion and western medication.
		                        		
		                        			METHODS:
		                        			Sixty patients with Bell's facial palsy in the acute stage were randomly divided into an observation group and a control group, with 30 cases in each one. The patients in the control group were administered orally with prednisone acetate tablets and methylcobalamin tablets until the 28th day of illness. In the observation group, the staging comprehensive treatment with acupuncture-moxibustion was adopted. On the affected side, Qianzheng (EX-HN 16), Yifeng (TE 17), Sibai (ST 2), Yangbai (GB 14), Jiache (ST 6), Dicang (ST 4) and Touwei (ST 8), etc. were stimulated. In the acute stage (Day 1 to 7 of illness), the routine acupuncture and the point-toward-point needle insertion were delivered, no any manipulation was exerted at acupoints, and the needles were retained for 30 min. In the subacute stage (Day 8 to 14 of illness), on the base of the treatment as the acute stage, the depth of needle insertion was adjusted at a part of acupoints and the even needling technique was operated by twisting needle. Besides, electroacupuncture (EA) was attached to Qianzheng (EX-HN 16) and Dicang (ST 4), with continuous wave of low intensity and high frequency, 100 Hz, for 20 min. In the recovery stage (Day 15 to 28 of illness), on the base of the treatment as the subacute stage, the heavy stimulation of acupuncture was given, in which, the sticking and lifting needle techniques were delivered after the needles were inserted from Sibai (ST 2) toward Dicang (ST 4), and from Dicang (ST 4) toward Jiache (ST 6), separately; warm needling was operated at Yifeng (TE 17), and EA changed to stimulate the acupoints with the intermittent wave of high intensity and low frequency, 2 Hz, for 30 min. Acupuncture-moxibustion was given once every other day until the end of the 28th day of illness. The level of House-Brackmann facial nerve function rating scale (H-B grade),the score of Sunnybrook facial nerve grading system (Sunnybrook), the score of facial disability index (FDI), the temperature difference in the infrared thermal imaging facial area and electromyogram (EMG) situation of the affected muscle group were observed before and after treatment in the two groups. Using musculoskeletal ultrasound,the facial nerve diameter was detected and the clinical effect was compared between the two groups.
		                        		
		                        			RESULTS:
		                        			After treatment, the level of H-B grade, Sunnybrook score, the scores of physical function and social life function in FDI were improved when compared with those before treatment in the patients of either group (P<0.01, P<0.05), and the results of these evaluations in the observation group were better than those of the control group (P<0.05). After treatment, the temperature difference of the frontal area, the eye area, the zygomatic area and the mouth corner was declined in comparison with that before treatment in the two groups (P<0.05), and the temperature difference in each area in the observation group was lower than that of the control group (P<0.05).The root mean square (RMS) of the frontal muscle group, the zygomatic muscle group and the orbicularis muscle group on the affected side increased in comparison with that before treatment in the two groups (P<0.01), and RMS of the observation group was higher than that of the control group (P<0.05) after treatment. Before treatment, the diameter of the facial nerve on the affected side was larger than that on the healthy side (P<0.01), and after treatment, the diameter on the affected side was reduced when compared with that before treatment in the two groups (P<0.01); the diameter of the facial nerve on the affected side in the observation group was smaller than that of the control group (P<0.05), while, the diameter on the affected side was larger when compared with the healthy side in the control group (P<0.05). The total effective rate of the observation group was 93.3% (28/30), higher than that of the control group (83.3% [25/30], P<0.05).
		                        		
		                        			CONCLUSIONS
		                        			The staging comprehensive treatment with acupuncture-moxibustion is clearly effective on Bell's facial palsy in the acute stage, which affirms the effectiveness of acupuncture-moxibustion for the acute stage of Bell's facial palsy in comparison with conventional western medication.
		                        		
		                        		
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Facial Paralysis/therapy*
		                        			;
		                        		
		                        			Moxibustion
		                        			;
		                        		
		                        			Acupuncture Therapy
		                        			;
		                        		
		                        			Bell Palsy/therapy*
		                        			;
		                        		
		                        			Face
		                        			
		                        		
		                        	
7.Long-term efficacy of self-designed posterior atlas polyaxial screw-plate in the treatment of unstable atlas fracture
Qiang ZHU ; Haiping ZHANG ; Liang YAN ; Baorong HE ; Xibin YANG ; Yonghong JIANG ; Dingjun HAO
Chinese Journal of Trauma 2024;40(3):206-213
		                        		
		                        			
		                        			Objective:To investigate the long-term efficacy of self-designed posterior atlas polyaxial screw-plate in the treatment of unstable atlas fracture.Methods:A retrospective case series study was conducted to analyze the clinical data of 20 patients with unstable atlas fracture who were admitted to Affiliated Honghui Hospital of Xi′an Jiaotong University from January 2011 to April 2013, including 14 males and 6 females, aged 23-60 years [(42.7±8.6)years]. All the patients were treated with internal fixation using self-designed posterior atlas polyaxial screw-plate. The operation time and intraoperative bleeding volume were recorded. The fracture reduction was evaluated by CT scan at 3 days after surgery. The bone healing was observed by X-ray (anterior-posterior and lateral views of the cervical spine) and CT scan at 9 months after surgery. The delayed spinal cord injuries were evaluated by Frankel grade at 1 and 2 years after surgery and at the last follow-up. The Visual Analogue Scale (VAS) before surgery, at 3 months, 1 year, 2 years after surgery and at the last follow-up were compared. The axial rotation, flexion and extension range of the cervical spine at 3 months, 1 year, 2 years after surgery and at the last follow-up were compared. Intraoperative and postoperative complications were observed.Results:All the patients were followed up for 121-148 months [(135.0±6.8)months]. The operation duration was 68-122 minutes [(86.0±14.1)minutes], with the intraoperative blood loss of 90-400 ml [(120.0±67.9)ml]. The CT scan of the cervical spine at 3 days after surgery showed all satisfactory fracture reduction. Satisfactory bone reunion was observed at 9 months after surgery. All patients were scaled as Frankel grade E at 1 year, 2 years and at the last follow-up after surgery, with no delayed spinal cord injuries observed. The VAS scores of the cervical spine at 3 months, 1 year, 2 years after surgery and at the last follow-up were 2.0(1.3, 3.0)points, 1.0(1.0, 1.8)points, 1.0(0.3, 1.0)points and 1.0(0.3, 1.0)points, which were significantly lower than that before surgery [7.0(6.0, 7.8)points] ( P<0.05), with significantly lower scores at 1-, 2-year after surgeny and at the last follow-up than at 3 months after surgery ( P<0.05). There were no significant differences among the other time points ( P>0.05). The axial rotation ranges of the cervical spine were (103.0±8.3)°, (128.3± 11.4)° and (129.8±13.6)° at 1 year, 2 years after surgery and at the last follow-up respectively, which were significantly higher than that at 3 months after surgery [(85.3±7.0)°] ( P<0.05); It was further improved at 2 years after surgery and at the last follow-up compared with that at 1 year after surgery ( P<0.05), with no significant difference at the last follow-up compared with that at 2 years after surgery ( P>0.05). The flexion and extension range of the cervical spine at 1 year, 2 years after surgery and at the last follow-up were (65.5±4.8)°, (78.3±6.5)° and (79.3±6.9)° respectively, which were significantly higher than that at 3 months after surgery [(54.3±4.4)°] ( P<0.05); It was further improved at 2 years after surgery and at the last follow-up compared with that at 1 year after surgery ( P<0.05), with no significant difference between the last follow-up and 2 years after surgery ( P>0.05). No intraoperative injuries such as arteriovenous injury were observed. No incision infection or dehiscence occurred after surgery, with no complications caused by long-term bed rest such as lung or urinary tract infection, pressure sore formation or deep vein thrombosis occurred. No loosening or breakage of the screw and atlas plate was observed at the long-term follow-up. One patient had mild cervical pain, snap during rotation, and limited range of motion at the last follow-up. Conclusion:Self-designed posterior atlas polyaxial screw-plate has merits including small surgical wounds, satisfactory reduction, solid fixation, obvious pain relief, effective preservation of the previous cervical motion, few complications, and satisfactory long-term efficacy in the treatment of unstable atlas fracture.
		                        		
		                        		
		                        		
		                        	
8.Summary of the first working meeting of the 8th Editorial Committee of Chinese Journal of Nephrology
Miao PENG ; Kekui YANG ; Haiping MAO ; Xueqing YU
Chinese Journal of Nephrology 2024;40(1):1-3
		                        		
		                        			
		                        			The first working meeting of the 8th Editorial Committee of Chinese Journal of Nephrology was held in Guangzhou, China on November 30, 2023. At the meeting, the list of the 8th Editorial Committee was announced, the work of the journal in the past 5 years was summarized, and the future work of the Editorial Committee was planned and discussed. Jiang Yongmao, former deputy secretary-general of the Chinese Medical Association, Jin Dong, deputy general manager of the Chinese Medical Journals Publishing House Co., Ltd, Lu Quan, editor of the Journal Management Department of Chinese Medical Association, Yu Xueqing, editor-in-chief of the 8th Editorial Committee, Cai Guangyan, Chen Jianghua, Zhao Minghui and Mao Haiping, deputy editor-in-chief of the 8th Editorial Committee, and 69 members of the 8th Editorial Committee, attended the meeting. The meeting came to a successful conclusion, and provided guidance for how to break through the difficulties, publish high-quality content and achieve high-quality development under the new situation.
		                        		
		                        		
		                        		
		                        	
9.Analysis on prevalence of chronic kidney disease in adults in Qingdao, 2019-2020
Longfei QIU ; Yuanyuan ZHAO ; Hua ZHANG ; Xiaojia XUE ; Yang ZHAO ; Yaoyao XU ; Haiping DUAN
Chinese Journal of Epidemiology 2024;45(5):694-699
		                        		
		                        			
		                        			Objective:To understand the prevalence of chronic kidney disease (CKD) in adults in Qingdao.Methods:A multi-stage stratified random sampling method was used to select 6 240 local residents aged ≥18 years in Qingdao as study subjects from May 2019 to September 2020, the demographic data of the study subjects were collected by face-to-face survey method. The prevalence of CKD in adults in Qingdao were analyzed using software SPSS 25.0.Results:A total of 5 996 adults in Qingdao were included in this study. The overall prevalence rate of CKD in the adults was 8.22%. The prevalence rates of CKD in men and women were 7.70% and 8.74%, respectively. The prevalence rate of CKD was 10.28% in urban residents and 7.25% in rural residents, the differences in the prevalence of CKD among different age, educational level and marital status groups were significant ( P<0.001). The prevalence of CKD tended to increase with age and decrease with the increase of education level. Conclusions:The prevalence of CKD in adults of Qingdao was relatively high. It is necessary to actively carry out the early prevention and treatment of CKD and strengthen the screening and prevention of CKD to reduce the incidence and slow development of CKD.
		                        		
		                        		
		                        		
		                        	
10.Association of solid fuel use for heating and smoking with respiratory diseases: a prospective cohort study
Yang YU ; Xiaocao TIAN ; Hua ZHANG ; Dan HU ; Jun LYU ; Canqing YU ; Pei PEI ; Dianjianyi SUN ; Ruqin GAO ; Zengchang PANG ; Haiping DUAN
Chinese Journal of Epidemiology 2024;45(10):1356-1361
		                        		
		                        			
		                        			Objective:To investigate the association between solid fuel use for heating, smoking, and respiratory diseases.Methods:This study is based on the Qingdao project of the China Kadoorie Biobank. After screening, 26 165 individuals were included in the study. We employed Cox proportional hazards regression models, stratified by risk age (in 5-year intervals) and sex while adjusting for confounding variables such as occupation and physical activity level to analyze the association between solid fuel use for heating, smoking, and increased risk of respiratory diseases.Results:Among the 26 165 participants, the average age of those using solid fuel for heating was (52.57±10.31) years, with females constituting 58.04% and former/current smokers accounting for 65.38%. The results indicated that both the solid fuel group and the former/current smoking group had a higher risk of respiratory diseases, with hazard ratios ( HR) (95% CI) of 1.21 (1.04-1.41) and 1.41 (1.16-1.71), respectively. For the duration of solid fuel use, the HR (95% CI) for 20 years or more, it was 1.27 (1.07-1.51). The multiplicative interaction term between solid fuel use and smoking was statistically significant. Conclusions:The use of solid fuel for heating and smoking significantly increases the risk of respiratory diseases, and there may be a multiplicative interaction between solid fuel use and smoking.
		                        		
		                        		
		                        		
		                        	
            
Result Analysis
Print
Save
E-mail