1.Physics issues on plan design and evaluation for stereotactic radiotherapy based on linear accelerator
Xuetao WANG ; Xin WANG ; Sen BAI ; Renming ZHONG
Chinese Journal of Radiation Oncology 2021;30(3):221-229
Stereotactic radiotherapy (SRT), also known as stereotactic ablative radiotherapy (SABR), includes stereotactic radiosurgery and stereotactic body radiotherapy (SBRT). This technique has the characteristics of large single fractional dose, few fractions, high equivalent biological doses, and rapid fall off-target doses. It can be implemented by relatively special equipment such as Gamma knife, Cyberknife, Tomotherapy and Vero 4D RT system, etc. In many cases, SBRT technique is employed based on linear accelerators. SRT differs from conventional radiotherapy in terms of the plan design and plan evaluation. Consequently, it is necessary to discuss the differences and provide guidance for clinical application and research.
2.Evaluation of fully automated volumetric modulated arc therapy planning of cervical cancer in RayStation treatment planning system
Xuetao WANG ; Jianghong XIAO ; Jianling ZHAO ; Qiang WANG ; Ying SONG ; Sen BAI
Chinese Journal of Radiological Medicine and Protection 2018;38(10):751-755
Objective To evaluate the feasibility of an in-room automated volumetric arc therapy (VMAT) planning engine based on dose volume histogram (DVH) prediction model in RayStation treatment planning system.Methods A total of 4,0 VMAT plans of cervix cancer,planned by experts,were chosen to build DVH estimation model by principal component regression analytic method.An in-room automated VMAT planning program based on IroPython scripting language combined with DVH prediction model was performed in RayStation treatment planning system.The DVH estimation model was applied to Another 10 testing cases of cervical cancer and the feasibility was evaluated by comparing the automatic plans with manual plans.Results The predicted DVH of organs at risk showed a good fit with real DVH in the ten testing cases.There were no statistically significant differences between manual and automatic plans in PTV conformal index (CI) and homogeneity index (HI) (P > O.05).V40 and V50 of bladder were significantly decreased by 4.3% and 1.6% in automatic plans (t =2.75,5.26,P < 0.05).V30,V40 and Vs0 of rectum were also decreased by 6.8%,5.8 % and 2.1% (t =2.26,3.55,5.19,P < 0.05).Both left and right femoral heads were better spared in automatic plans with average doses decreased by 380 and 322 cGy(t =5.55,7.25,P < 0.05).The time of creating a treatment plan was 36 min for automatic plan and 53 min for manual plan.Conclusions The fully automated VMAT treatment plan program can create a VMAT plan of cervix cancer with high efficiency and good quality.
3.The key problems in the population exposure assessment of hazardous chemicals accidents
Lijun PAN ; Fengping LIU ; Xu ZHANG ; Xuetao BAI ; Xiaoming SHI
Chinese Journal of Preventive Medicine 2016;50(7):573-576
Serious accidents of hazardous chemicals can cause a variety of acute or chronic impairment in human health. The effects of hazardous chemicals on human health can be identified by carrying on population exposure assessment. Through analyzing the domestic and overseas population exposure assessment cases related to hazardous chemicals accidents, we summarized that the base and key of the population exposure assessment were to identify the characteristics of the chemicals , delimit the area and the population exposed to the chemicals, and collect the data of the monitored chemicals and the population health in the polluted area.
4.The key problems in the population exposure assessment of hazardous chemicals accidents
Lijun PAN ; Fengping LIU ; Xu ZHANG ; Xuetao BAI ; Xiaoming SHI
Chinese Journal of Preventive Medicine 2016;50(7):573-576
Serious accidents of hazardous chemicals can cause a variety of acute or chronic impairment in human health. The effects of hazardous chemicals on human health can be identified by carrying on population exposure assessment. Through analyzing the domestic and overseas population exposure assessment cases related to hazardous chemicals accidents, we summarized that the base and key of the population exposure assessment were to identify the characteristics of the chemicals , delimit the area and the population exposed to the chemicals, and collect the data of the monitored chemicals and the population health in the polluted area.
5.Image registration of a three-dimensional dynamic phantom in four-dimensional cone-beam computed tomography and four-dimensional computed tomography
Chen SU ; Sen BAI ; Guangjun LI ; Yingjie ZHANG ; Renming ZHONG ; Feng XU ; Yanlong LI ; Xuetao WANG
Chinese Journal of Radiation Oncology 2015;(5):581-584
Objective To evaluate the image quality and registration accuracy of a three?dimensional ( 3D ) dynamic phantom in four?dimensional computed tomography ( 4DCT ) and four?dimensional cone?beam computed tomography ( 4DCBCT) . Methods The Computerized Imaging Reference Systems Dynamic Thorax Phantom Model 008A was scanned to get 4DCT and 4DCBCT images. Two balls with different diameters ( ?= 1 cm and ?= 2 cm) were used to simulate tumors with different sizes. The motion mode of the balls was 3D sinusoidal motion at 0?25 Hz ( the amplitudes along the x, y, and z axes were ±1?0 cm, ±0?4 cm, and ±0?2 cm, respectively). Gross target volumes (GTVs) from 10?phase bins, internal gross target volumes (IGTV), and target volumes on maximum intensity projection (MIP) and mean intensity projection (MeanIP) images were contoured and calculated. Target volumes on 4DCT or 4DCBCT images were compared with the static and dynamic volumes of the balls ( VS and VD ) . The matching index ( MI) of target volumes between the 4DCT and 4DCBCT images was analyzed after rigid image registration. Results The GTV in each phase of the image was larger than VS . The difference between the average GTV derived from 10 phases of 4DCT or 4DCBCT images and Vs of the small ball was larger than that of the large ball ( 35?03% vs. 22?66%;32?62% vs. 17?00%) . All the IGTVs and target volumes on MIP images were slightly larger than VD , but target volumes on MeanIP images were smaller than VD . The average MI of 10?phase bins of the small ball was smaller than that of the large ball ( 66?76% vs. 82?21%) . Moreover, MIs of IGTV,MIP, and MeanIP of the small ball were also smaller than those of the large ball ( 77?39% vs. 90?29%;75?90% vs. 89?28%;74?47% vs. 82?74%) . Conclusions In the case of a relatively small tumor volume and a relatively large motion amplitude, 4DCT and 4DCBCT should be used with caution for comparison of image registration.
6.Quality control of linac in daily volumetric-modulated arc therapy
Guangjun LI ; Yanlong LI ; Jianghong XIAO ; Xuetao WANG ; Chen SU ; Sen BAI
Chinese Journal of Radiation Oncology 2015;24(2):200-204
Objective To verify the daily delivery accuracy of volumetric-modulated arc therapy (VMAT) and achieve the process quality control (PQC) of linac using statistical process control (SPC)technology.Methods The log files of all treatments were taken out from the linac system.An in-house software which created by Matlab 7.14 was used to analyze the daily parameters accuracy and the mechanism and dose delivery accuracy of the linac for each VMAT,and an daily evaluation report was automatically created for the linac.The stability of the linac and the deviation of the delivery accuracy for various cancer sites were also analyzed.To achieve the process quality control of hnac using SPC technology,the control limit of each parameter was calculated by Johnson alternation and the single value control charts were drawn.Results 76 patients mainly with nasopharyngeal carcinoma,cervical carcinoma,rectal cancer and laryngeal cancer,got the treatment daily with VMAT technology,and a total of 2 446 arcs were delivered by the linac in continuous 16 days.The gantry angle error,y and x collimator position error,MLC leaf position error and dose delivery error were 0.49°,0.09 mm,0.38 mm,0.31 mm,0.05 MU,respectively.Compare to the nasopharynx,uteri,rectal and larynx cancer,it can be seen that the variation factors of dose delivery and gantry angle errors for various cancer sites were higher,which was 8.10% and 4.54%,respectively.Through the process quality control of the linac,it was found that all the parameters were in control.While some abnormal points arose (the error was greater than UCL),and the ratio of the gantry angle which was out of control (0.45%) was the highest in all parameters.Conclusions linac delivery accuracy could be monitored and verified during the whole VMAT treatment for each patient,and the daily running condition of linac could be monitored.Through the introduction of SPC technology and the control charts,the process quality control of linac in VMAT could be achieved.It is a financial and valid method for the daily quality assurance of linac.
7.Investigation of CT numbers correction of kilo-voltage cone-beam CT images for accurate dose calculation
Xuetao WANG ; Sen BAI ; Guangjun LI ; Xiaoqin JIANG ; Chen SU ; Yanlong LI ; Zhihui ZHU
Chinese Journal of Radiation Oncology 2015;(4):457-461
Objective To study CT numbers correction of kilo?voltage cone?beam CT (KV?CBCT) images for dose calculation. Method Aligning the CBCT images with plan CT images, then obtain the background scatter by subtracting CT images from CBCT images. The background scatter is then processed by low?pass filter. The final CBCT images are acquired by subtracting the background scatter from the raw CBCT. KV?CBCT images of Catphan600 phantom and four patients with pelvic tumors were obtained with the linac?integrated CBCT system. The CBCT images were modified to correct the CT numbers. Finally, compare HU numbers between corrected CBCT and planning CT by paired T test. Evaluate the image quality and accuracy of dose calculation of the modified CBCT images. Results The proposed method reduces the artifacts of CBCT images significantly. The differences of CT numbers were 232 HU, 89 HU, 29 HU and 66 HU for air, fat, muscle and femoral head between CT and CBCT respectively (P= 0?? 39,0?? 66,0?? 59,1).The differences of CT numbers between CT and CBCT was reduced to within 5 HU. And the error of dose calculation with corrected CBCT images was within 2%. Conclusions The CT numbers of corrected CBCT are similar with plan CT images and dose calculations based on the modified CBCT show good agreement with plan CT.
8.Comparative study between off-pump and on-pump of coronary artery bypass grafting
Xu CAO ; Qiang XIE ; Ming JING ; Meng LI ; Xuetao BAI ; Hongwei JIANG
Chinese Journal of Postgraduates of Medicine 2010;33(2):9-10
Objective To compare the clinical effect of off-pump coronary artery bypass grafting (eft-pump CABG)and on-pump coronary artery bypass grafting(on-pump CABG).Methods The clinical dates of 152 cases with coronary artery bypass grafting(off-pump CABG group 85 cases,on-pump CABG group 67 cases)were received from June 2005 to December 2008,the preoperative dates,postoperative mortality and the rate of complication were compared between two groups.Results The preoperative dates of two groups were no significant difference(P>0.05);2 cases(2.35%)were died in off-pump CABG group and 13 cases(15.29%)had complications in off-pump CABG group;9 cases(13.43%)were died in on-pump CABG group and 25 cases(37.31%)had complications in on-pump CABG group.The mortality and the rate of complication in off-pump CABG group was significantly less than that in on-pump CABG group.it was significant difference(P<0.01).Conclusion Off-pump CABG is safe therapy of mieosurgieal operation.
9.Wnt3a is Important in The Differentiation From Neural Stem Cell Into Dopaminergic Neuron In vitro
Shu HAN ; Wei SHI ; Yanhua LI ; Hailei YAO ; Xiaoyan XIE ; Lin CHEN ; Shuangshuang SHI ; Cixian BAI ; Xue NAN ; Fang YAN ; Yunfang WANG ; Xuetao PEI
Progress in Biochemistry and Biophysics 2006;0(10):-
Wnt signaling is implicated in the control of cell growth and differentiation during neural stem cell(CNS) development.Wnt3a, one of wnt gene family members, has effect on regeneration neurospheres and differentiation into neurons.Wnt3a inhibits regeneration of neurospheres, and promotes its differentiation. In vitro neurosphere was cultured in a serum-free defined medium DMEM/F12 supplemented with bFGF and EGF. Dissociated cells were plated onto poly-d-lysine-coated coverslips and propagated in medium containing recombined Wnt3a-adenovirus. Plenty of Nurr1 were detected by RT-PCR after 3 days. Wnt3a combined AA would improve NSC differentiation into dopaminergic (DA) neuron. The quantity of DA neuron is obviously more than the AA alone group's. Moreover, the expression of TH mRNA is 1.86 fold in Wnt3a combined AA group. Induced cells were immunostained for TH and DAT. The proportion of TH-positive was (37.42 ? 2.54) % (P
10.NRSF Plays a Regulatory Role in Human Insulin Gene Transcription
Qingbin LIU ; Yanhua LI ; Yinxiang YANG ; Hongfeng YUAN ; Rui ZHANG ; Lipeng QIN ; Yang L ; Sainan ZHANG ; Dijin SUN ; Lin CHEN ; Cixian BAI ; Xue NAN ; Yunfang WANG ; Xuetao PEI
Progress in Biochemistry and Biophysics 2006;0(09):-
The transcriptional repressor RE1 silencer transcription factor(NRSF/REST) is an important factor that restricts some neuronal traits in neurons.Since these traits are also present in pancreatic islet cells,NRSF-regulated genes involved in islet function are searched.A NRSE-like motif was analysed in human insulin promoter.The role of NRSE was evaluated by generating a model of insulin-secreting cells that firmly express NRSF.The presence of NRSF led to a decrease in activity of human insulin promoter by stable or transient transfection with human insulin-promoter luciferase.The predicted NRSE-like motif also confers NRSF-dependent transcriptional repression in the context of a surrogate gene promoter.Specific binding activity of NRSF/REST to the NRSE-like motif was confirmed by EMSA.Moreover,the binding activity is competed by consensus NRSE sequence.These data showed that human insulin promoter is regulated by the transcriptional repressor NRSF/REST via the NRSE-like motif.

Result Analysis
Print
Save
E-mail