1.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
2.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
3.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
4.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
5.Chinese expert consensus on blood support mode and blood transfusion strategies for emergency treatment of severe trauma patients (version 2024)
Yao LU ; Yang LI ; Leiying ZHANG ; Hao TANG ; Huidan JING ; Yaoli WANG ; Xiangzhi JIA ; Li BA ; Maohong BIAN ; Dan CAI ; Hui CAI ; Xiaohong CAI ; Zhanshan ZHA ; Bingyu CHEN ; Daqing CHEN ; Feng CHEN ; Guoan CHEN ; Haiming CHEN ; Jing CHEN ; Min CHEN ; Qing CHEN ; Shu CHEN ; Xi CHEN ; Jinfeng CHENG ; Xiaoling CHU ; Hongwang CUI ; Xin CUI ; Zhen DA ; Ying DAI ; Surong DENG ; Weiqun DONG ; Weimin FAN ; Ke FENG ; Danhui FU ; Yongshui FU ; Qi FU ; Xuemei FU ; Jia GAN ; Xinyu GAN ; Wei GAO ; Huaizheng GONG ; Rong GUI ; Geng GUO ; Ning HAN ; Yiwen HAO ; Wubing HE ; Qiang HONG ; Ruiqin HOU ; Wei HOU ; Jie HU ; Peiyang HU ; Xi HU ; Xiaoyu HU ; Guangbin HUANG ; Jie HUANG ; Xiangyan HUANG ; Yuanshuai HUANG ; Shouyong HUN ; Xuebing JIANG ; Ping JIN ; Dong LAI ; Aiping LE ; Hongmei LI ; Bijuan LI ; Cuiying LI ; Daihong LI ; Haihong LI ; He LI ; Hui LI ; Jianping LI ; Ning LI ; Xiying LI ; Xiangmin LI ; Xiaofei LI ; Xiaojuan LI ; Zhiqiang LI ; Zhongjun LI ; Zunyan LI ; Huaqin LIANG ; Xiaohua LIANG ; Dongfa LIAO ; Qun LIAO ; Yan LIAO ; Jiajin LIN ; Chunxia LIU ; Fenghua LIU ; Peixian LIU ; Tiemei LIU ; Xiaoxin LIU ; Zhiwei LIU ; Zhongdi LIU ; Hua LU ; Jianfeng LUAN ; Jianjun LUO ; Qun LUO ; Dingfeng LYU ; Qi LYU ; Xianping LYU ; Aijun MA ; Liqiang MA ; Shuxuan MA ; Xainjun MA ; Xiaogang MA ; Xiaoli MA ; Guoqing MAO ; Shijie MU ; Shaolin NIE ; Shujuan OUYANG ; Xilin OUYANG ; Chunqiu PAN ; Jian PAN ; Xiaohua PAN ; Lei PENG ; Tao PENG ; Baohua QIAN ; Shu QIAO ; Li QIN ; Ying REN ; Zhaoqi REN ; Ruiming RONG ; Changshan SU ; Mingwei SUN ; Wenwu SUN ; Zhenwei SUN ; Haiping TANG ; Xiaofeng TANG ; Changjiu TANG ; Cuihua TAO ; Zhibin TIAN ; Juan WANG ; Baoyan WANG ; Chunyan WANG ; Gefei WANG ; Haiyan WANG ; Hongjie WANG ; Peng WANG ; Pengli WANG ; Qiushi WANG ; Xiaoning WANG ; Xinhua WANG ; Xuefeng WANG ; Yong WANG ; Yongjun WANG ; Yuanjie WANG ; Zhihua WANG ; Shaojun WEI ; Yaming WEI ; Jianbo WEN ; Jun WEN ; Jiang WU ; Jufeng WU ; Aijun XIA ; Fei XIA ; Rong XIA ; Jue XIE ; Yanchao XING ; Yan XIONG ; Feng XU ; Yongzhu XU ; Yongan XU ; Yonghe YAN ; Beizhan YAN ; Jiang YANG ; Jiangcun YANG ; Jun YANG ; Xinwen YANG ; Yongyi YANG ; Chunyan YAO ; Mingliang YE ; Changlin YIN ; Ming YIN ; Wen YIN ; Lianling YU ; Shuhong YU ; Zebo YU ; Yigang YU ; Anyong YU ; Hong YUAN ; Yi YUAN ; Chan ZHANG ; Jinjun ZHANG ; Jun ZHANG ; Kai ZHANG ; Leibing ZHANG ; Quan ZHANG ; Rongjiang ZHANG ; Sanming ZHANG ; Shengji ZHANG ; Shuo ZHANG ; Wei ZHANG ; Weidong ZHANG ; Xi ZHANG ; Xingwen ZHANG ; Guixi ZHANG ; Xiaojun ZHANG ; Guoqing ZHAO ; Jianpeng ZHAO ; Shuming ZHAO ; Beibei ZHENG ; Shangen ZHENG ; Huayou ZHOU ; Jicheng ZHOU ; Lihong ZHOU ; Mou ZHOU ; Xiaoyu ZHOU ; Xuelian ZHOU ; Yuan ZHOU ; Zheng ZHOU ; Zuhuang ZHOU ; Haiyan ZHU ; Peiyuan ZHU ; Changju ZHU ; Lili ZHU ; Zhengguo WANG ; Jianxin JIANG ; Deqing WANG ; Jiongcai LAN ; Quanli WANG ; Yang YU ; Lianyang ZHANG ; Aiqing WEN
Chinese Journal of Trauma 2024;40(10):865-881
Patients with severe trauma require an extremely timely treatment and transfusion plays an irreplaceable role in the emergency treatment of such patients. An increasing number of evidence-based medicinal evidences and clinical practices suggest that patients with severe traumatic bleeding benefit from early transfusion of low-titer group O whole blood or hemostatic resuscitation with red blood cells, plasma and platelet of a balanced ratio. However, the current domestic mode of blood supply cannot fully meet the requirements of timely and effective blood transfusion for emergency treatment of patients with severe trauma in clinical practice. In order to solve the key problems in blood supply and blood transfusion strategies for emergency treatment of severe trauma, Branch of Clinical Transfusion Medicine of Chinese Medical Association, Group for Trauma Emergency Care and Multiple Injuries of Trauma Branch of Chinese Medical Association, Young Scholar Group of Disaster Medicine Branch of Chinese Medical Association organized domestic experts of blood transfusion medicine and trauma treatment to jointly formulate Chinese expert consensus on blood support mode and blood transfusion strategies for emergency treatment of severe trauma patients ( version 2024). Based on the evidence-based medical evidence and Delphi method of expert consultation and voting, 10 recommendations were put forward from two aspects of blood support mode and transfusion strategies, aiming to provide a reference for transfusion resuscitation in the emergency treatment of severe trauma and further improve the success rate of treatment of patients with severe trauma.
6.Serum myostatin and follistatin as biomarkers of sarcopenia in elderly women
Yanping DU ; Ye YANG ; Wenjing TANG ; Minmin CHEN ; Huilin LI ; Weijia YU ; Xiaoqing WU ; Liu SHEN ; Xuemei ZHANG ; Yuxiang ZHENG ; Jianfei GU ; Qun CHENG
Chinese Journal of Endocrinology and Metabolism 2024;40(6):500-504
Objective:This study aimed to explore the clinical value of myostatin(MST) and follistatin(FST) as biological biomarkers in evaluating sarcopenia in elderly women.Methods:This was a retrospective cross-sectional study that enrolled 350 females aged 20-89 years who underwent physical examinations in Shanghai Huadong Hospital in 2021. Demographic characteristics, muscle mass, fat mass, bone mineral density, hand grip strength, gait speed, and serum indices of MST and FST were collected.Results:The serum levels of MST did not change significantly with age. However, the serum levels of FST increased with age. In women aged≥60 years, MST was positively correlated with total lean mass and appendicular skeletal muscle index(ASMI; r=0.236, P=0.041; r=0.289, P=0.014), while FST was negatively correlated with ASMI( r=-0.265, P=0.030). In multivariate stepwise regression analysis, after adjusting for age, body mass index, hip bone mineral density, and total fat mass, only FST was independently correlated with ASMI( β=-0.238, P=0.006), while MST was not correlated with ASMI. The receiver operating characteristic curve was plotted using muscle mass reduction as the state variable and serum FST level as the test variable. The area under the curve was 0.753. And when the FST cutoff value was 17.49 ng/mL, the maximum Jordan index was 0.46, with a sensitivity of 77.3% and a specificity of 68.7%. Women aged ≥60 years were divided into three groups based on serum FST levels. Compared to the upper third of the serum FST level group, the low third of the FST level group had a significantly reduced risk of suffering from sarcopenia( OR=0.098, P =0.036). Conclusions:Serum FST lever has a better correlation with muscle mass among elderly women, making it a promising biomarker for evaluating muscle mass.
7.The 508th case: recurrent edema of bilateral lower extremities with proteinuria
Qiuyu XU ; Gang CHEN ; Chenhao YANG ; Ke ZHENG ; Jie MA ; Chao LI ; Xiaohong FAN ; Wei YE ; Yubing WEN ; Limeng CHEN ; Xuemei LI
Chinese Journal of Internal Medicine 2024;63(8):816-820
A 31-year-old man sought medical evaluation for a 2-year history of edema and proteinuria, with prior pathology suggesting atypical membranous nephropathy (MN). Despite treatment with a combination of steroids, calcineurin inhibitors, and four courses of rituximab (1 g, intravenous injection), the patient′s nephrotic syndrome showed no relief (24 h urine protein peaked at 31.18 g/d), indicating refractory nephrotic syndrome. Later in the disease course, a sudden surge of creatinine level (322.5 μmol/L) prompted a renal biopsy, which revealed concurrent acute interstitial nephritis. Further treatment involving steroids, cyclophosphamide, and a fifth rituximab infusion (1 g, intravenous injection) resulted in improvement in renal function (serum creatinine: 322.5?147 μmol/L), but the MN failed to achieve partial relief. Subsequent treatment with the novel humanized CD20 monoclonal antibody obinutuzumab (1 g, intravenous injection) was initiated. In the latest follow-up, anti-phospholipase-A2-receptor antibody (PLA2R) antibody were negative, B cells were eliminated, serum albumin was 36 g/L, urine protein-to-creatinine ratio was 4 810 mg/g, and serum creatinine was 162 μmol/L. This case underscores the potential efficacy of obinutuzumab in refractory MN. For advanced MN cases, prompt identification of the cause of acute kidney injury is crucial, emphasizing the need for targeted interventions to potentially stall renal function decline.
8.The"suppressing wood-supporting earth"theory-based air moxibustion combined with pushpin-like needle acupuncture in the treatment of pain,nausea and vomiting after TACE:a clinical study
Xiaodi SHEN ; Pan YE ; Xuemei BIAN ; Qing SUN ; Yuru CHANG ; Yu ZHANG
Journal of Interventional Radiology 2024;33(9):1014-1018
Objective To investigate the clinical effect of air moxibustion combined with pushpin-like needle acupuncture,which is formulated based on the"suppressing wood-supporting earth"theory in the doctrine of the five elements of Traditional Chinese Medicine(TCM),in the treatment of pain,nausea and vomiting after transcatheter arterial chemoembolization(TACE).Methods A total of 160 patients with hepatocellular carcinoma,who were admitted to the First Affiliated Hospital of Zhejiang University of Traditional Chinese Medicine of China to receive initial TACE between July 2020 and June 2023,were enrolled in this study.The patients were randomly divided into 4 groups with 40 patients in each group.The patients of the control group received TACE with conventional nursing care,the patients of the pushpin-like needle group received pushpin-like needle acupuncture on the basis of the control group,the patients of the air moxibustion group received air moxibustion treatment on the basis of the control group,and the patients of the combination group received air moxibustion combined with pushpin-like needle acupuncture on the basis of the control group.The post-TACE pain degree(VAS scoring)and nausea/vomiting extent(INVR scoring)were compared between each other among the four groups.Results The differences in the VAS score and INVR score(including main effect and interaction effect)between each other among the four groups were statistically significant(all P<0.05).Statistically significant differences in the VAS score and INVR score existed between the control group and the other three groups(all P<0.05).The differences in the VAS score and INVR score between combination group and pushpin-like needle group,as well as between combination group and air moxibustion group were statistically significant(both P<0.05).Conclusion Air moxibustion combined with pushpin-like needle acupuncture can effectively and remarkably relieve post-TACE pain,nausea and vomiting,which is superior to simple use of air moxibustion or pushpin-like needle acupuncture.Therefor,the combination use of air moxibustion and pushpin-like needle acupuncture should be popularized in clinical practice.
9.The prognostic value of colonoscopy grading for acute graft-versus-host disease in patients with malignant hematological disorders after unrelated cord blood transplantation
Senlin WANG ; Guangyu SUN ; Xiaoyu ZHU ; Xuemei XU ; Fei YE ; Shilan LI ; Si CHEN
Chinese Journal of Hematology 2024;45(5):462-467
Objective:To investigate the prognostic value of enteroscopic grading for the prognostic assessment of patients with malignant hematological diseases who developed intestinal acute graft-versus-host disease (IT-aGVHD) after unrelated cord blood transplantation (UCBT) .Methods:Fifty patients with IT-aGVHD who developed hormone resistance after UCBT from June 2016 to June 2023 at Anhui Provincial Hospital were collected to compare the effective and survival rates of IT-aGVHD treatment in the group with milder enteroscopic mucosal injury (27 cases, enteroscopic grading of Ⅰ and Ⅱ) and the group with more severe injury (23 cases, enteroscopic grading of Ⅲ and Ⅳ) and to retrospectively analyze the factors affecting patients’ prognosis.Results:Patients in the mild and severe groups had an effective rate of 92.6% and 47.8% at 28 days after colonoscopy ( P<0.001), 81.5% and 39.1% at 56 days after colonoscopy ( P=0.002), with optimal effective rate of 92.6% and 65.2% ( P=0.040), respectively, and the differences were statistically significant. The multifactorial analysis found that enteroscopic grading was an independent risk factor affecting the effective rate of IT-aGVHD treatment. The overall survival rate at 2 years after colonoscopy was 70.4% (95% CI 52.0% -88.8% ) and 34.8% (95% CI 14.8% -54.8% ) for patients in the mild and severe groups, respectively, and the difference was statistically significant ( P=0.003). Multifactorial analysis revealed that enteroscopic grading, cytomegalovirus infection status, second-line treatment regimen, and patients’ age were independent risk factors for survival. Conclusion:The treatment efficacy and prognosis of patients in the group with less severe enteroscopic injury (grades Ⅰ and Ⅱ) were better than those in the group with more severe injury (grades Ⅲ and Ⅳ) .
10.Construction and preliminary application of nursing research clinic program based on grid management
Chenglin ZHANG ; Honglan SHAN ; Xuemei LI ; Xiaoyan LI ; Ye ZHU
Chinese Journal of Medical Science Research Management 2024;37(3):198-203
Objective:This study aimed to explore the implementation plan of the grid management joint scientific research clinic and to evaluate its impact on enhancing the scientific research capabilities of nursing staff.Methods:Nursing research team developed an implementation strategy for the grid management joint scientific research clinic in 2023 and then promoted it across the hospital. The scores of nursing staff were compared on the self-evaluation scale, general self-efficacy scale, and research innovation achievements before (April-December 2022) and after (January-September 2023) the implementation.Results:The research capabilities of nurses increased significantly from 103.13±2.56 to 141.32±18.09 ( P<0.001), and their self-efficacy increased significantly from 1.95±0.26 to 2.15±0.53 ( P<0.001). The number of college-level and above scientific research projects, the number of journal publications, the number of authorized patterns, the number of participation in academic exchanges at the municipal level and above in nursing societies, and the number of scientific research awards at the municipal level and above all increased compared with the previous ones with statistical significance. Conclusions:Implementing the grid management joint scientific research clinic is beneficial for improving overall nursing research capabilities, nurses' self-efficacy, and the effectiveness of scientific research training. This provides a reference for other hospitals to enhance the training of nursing staff's scientific research capabilities.

Result Analysis
Print
Save
E-mail