1.Quality Evaluation of Lycii Cortex and Roasted Lycii Cortex Based on Fingerprint and Content Determination
Yihuan WU ; Wenli ZENG ; Xuemei QIN ; Zongxin SHI ; Chengcheng HUANG ; Yuntao DAI
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(2):165-172
ObjectiveTo establish fingerprint profiles and a quantitative determination method for Lycii Cortex, providing a scientific basis for the formulation of quality standards for Lycii Cortex and its roasted products. MethodsHigh performance liquid chromatography(HPLC) was developed for the quantitative method for determining kukoamine B in Lycii Cortex and its roasted products on an Alphasil XD-C18 CH column(4.6 mm×250 mm, 5 μm). HPLC fingerprint profiles were established for 10 batches of Lycii Cortex and its roasted products, and ultra-performance liquid chromatography-quadrupole-time-of-flight mass spectrometry(UPLC-Q-TOF-MS) was used to identify the common peaks based on reference standards, literature and MS information. Quality evaluation indicators included yield of decoction pieces, appearance properties, content of kukoamine B, and fingerprint profiles. The temperature and time of the roasting process were investigated to select the optimal preparation process, which was then verified. Additionally, chemical pattern recognition was combined to assess the differences in the chemical composition of Lycii Cortex before and after roasting, as well as among samples from different origins. ResultsQuantitative analysis indicated that the contents of kukoamine B in Lycii Cortex and its roasted products were 0.35%-5.51% and 0.24%-4.15%, respectively. The transfer rate of kukoamine B was 58.6%-78.9% after roasting. The fingerprint profile analysis demonstrated that the method established in this study effectively separated kukoamine B from other components in the samples and distinctly differentiated it from its impurity peak, cis-N-caffeoylputrescine. The HPLC fingerprint profiles of Lycii Cortex and its roasted products showed high similarity(all above 0.95), with 7 common peaks identified and five common components, including kukoamine B, cis-N-caffeoylputrescine, N-coumaroyl tyramine, feruloyltyramine, and glucosyringic acid, confirmed. Process optimization confirmed that baking at 110 ℃ for 20 min was a stable and feasible method for roasting Lycii Cortex. Principal component analysis and cluster analysis showed that there was little difference in the chemical composition between raw and roasted Lycii Cortex, but the quality of Lycii Cortex from different origins differed greatly. ConclusionThis study successfully established the fingerprint profiles and a quantitative method for the effective component kukoamine B in Lycii Cortex and roasted Lycii Cortex. The qualitative and quantitative analyses clarified that the impact of the roasting process on the chemical composition of Lycii Cortex was less significant than the variations due to its geographical origin. The findings of this study offer a reference for the development of quality evaluation methods and the establishment of quality standards for Lycii Cortex and its processed products.
2.Psychological experiences and care needs of elderly patients with chronic obstructive pulmonary disease following dysphagia: a qualitative research
Ping GONG ; Yingru DOU ; Xuemei DAI ; Xueping JIANG ; Meifang WU ; Fan JIANG
Chinese Journal of Rehabilitation Theory and Practice 2025;31(1):117-124
ObjectiveTo explore psychological experiences and care needs of elderly patients with chronic obstructive pulmonary disease (COPD) following dysphagia. MethodsFrom April to June, 2024, 13 elderly patients with COPD and dysphagia received treatment in Yixing No. 2 People's Hospital (Yixing Occupational Disease Institute) and Northern Jiangsu People's Hospital were interviewed. Nvivo 11.0 and content analysis were employed to analyze and summarize themes. ResultsTwo main themes were identified. The psychological experiences included fear of eating due to swallowing and choking, swallowing anxiety in social situations, concerns about malnutrition, and emotional loss related to family. The care needs included improvement in swallowing function, adjustment of food texture, assistance with disease adaptation and effective access to health education information. ConclusionHealthcare professionals should thoroughly understand the psychological and needs of elderly patients with COPD-related dysphagia, and comprehensive nursing strategies should be developed and implemented to improve swallowing function and overall quality of life.
3.In Vitro and in vivo Component Identification of Danshenyin Based on UPLC-Q-TOF-MS/MS
Sitong ZHANG ; Xianrun HU ; Wenkang LIU ; Jinchun LEI ; Xuemei CHENG ; Xiaojun WU ; Wansheng CHEN ; Manlin LI ; Changhong WANG
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(9):175-183
ObjectiveTo elucidate the chemical composition of Danshenyin and its blood components in rats after oral administration. MethodsUltra performance liquid chromatography-quadrupole-time-of-flight tandem mass spectrometry(UPLC-Q-TOF-MS/MS) coupled with PeakView 1.2 software was used to systematically characterize and identify the components of Danshenyin aqueous extract and its migratory components in rat blood after oral administration based on the retention time, quasi-molecular ion peaks, secondary fragmentation ions, and literature reports, and a preliminary compounds identification of Salviae Miltiorrhizae Radix et Rhizoma aqueous extract, the co-decoction of Santali Albi Lignum and Amomi Fructus was carried out to attribute the chemical constituents of the aqueous extract of Danshenyin. ResultsA total of 73 compounds, including 21 phenolic acids, 23 diterpenes, 6 flavonoids, 7 organic acids, 3 volatile oils and 13 others, were identified from the aqueous extract of Danshenyin. And 36 prototypes and 15 metabolites were identified in rat plasma, the major metabolic pathways included reduction, hydration, hydroxylation, demethylation, methylation, sulfation and others, these metabolites were mainly derived from tanshinones and salvianolic acids. ConclusionThe main blood components of the aqueous extract of Danshenyin are salvianolic acids and tanshinones, which may be the material basis of the efficacy. This study can provide reference for pharmacological research, quality control, and clinical application of Danshenyin.
4.The relationship between serum c-kit mRNA level and myocardial fibrosis,cardiac function and prognosis in patients with dilated cardiomyopathy complicated with heart failure
Zhanwei ZHANG ; Jun ZHANG ; Xuemei XING ; Song WU ; Huan TIAN
International Journal of Laboratory Medicine 2024;45(6):641-646
Objective To investigate the relationship between serum stem cell factor receptor(c-kit)and myocardial fibrosis,cardiac function and prognosis in patients with dilated cardiomyopathy(DCM)complicat-ed with heart failure.Methods A total of 77 patients with DCM complicated with heart failure who were trea-ted in 3201 Hospital from May 2020 to June 2022 were enrolled in the study as study group,and 70 DCM pa-tients without heart failure were enrolled as the control group.The levels of serum c-kit mRNA and three my-ocardial fibrosis markers[α-smooth muscle actin(α-SMA),collagen type Ⅰ and collagen type Ⅲ]were detec-ted in the two groups.Cardiac function parameters were obtained by echocardiography.The relationship be-tween serum c-kit mRNA level and myocardial fibrosis and cardiac function was analyzed.According to the oc-currence of major adverse cardiovascular events(MACE),the patients were divided into poor prognosis group and good prognosis group.Multivariate Logistic regression analysis was used to analyze the factors affecting the prognosis of DCM patients complicated with heart failure.Receiver operating characteristic(ROC)curve was used to analyze the efficacy of serum c-kit mRNA level in predicting the prognosis of DCM patients.Results The serum c-kit mRNA level in the study group was lower than that in the control group(P<0.05).The levels of three myocardial fibrosis indicators in the study group were higher than those in the con-trol group(P<0.05).The left ventricular ejection fraction(LVEF)in the study group was lower than that in the control group(P<0.05),and the left ventricular end-diastolic volume(LVEDV)and left ventricular end-systolic volume(LVESV)in the study group were higher than those in the control group(P<0.05).Pearson correlation analysis showed that serum c-kit mRNA level was positively correlated with LVEF(r=0.677,P<0.05),while negatively correlated with α-SMA,collagen type Ⅰ,collagen type Ⅲ,LVEDV and LVESV(r=-0.725,-0.748,-0.744,-0.745,-0.662,P<0.05).Multivariate Logistic regression analysis showed that serum c-kit mRNA level is an independent factor for the prognosis of DCM patients with heart failure.ROC curve analysis showed that serum c-kit mRNA level had a sensitivity of 82.80%,a specificity of 81.80%,and an area under the curve of 0.829(95%CI:0.745-0.912,P<0.001)for evaluating the progno-sis of DCM patients complicated with heart failure.Conclusion The serum c-kit mRNA level is significantly decreased in patients with DCM complicated with heart failure,and the serum c-kit mRNA level is correlated with myocardial fibrosis and cardiac function.The detection of serum c-kit mRNA level has a high efficacy in evaluating the prognosis of patients with DCM complicated with heart failure.
5.Neuro-ophthalmic features of SARS-CoV-2 associated acute macular neuroretinopathy
Pei LIU ; Zhaojie CHU ; Bo LI ; Xuemei LIN ; Yan LIU ; Chensheng SONG ; Yan SUO ; Jun ZHAO ; Songdi WU
International Eye Science 2024;24(7):1173-1178
AIM: To explore the neuro-ophthalmological characteristics of acute macular neuroretinopathy(AMN)after SARS-CoV-2 infection.METHODS: A total of 8 patients(14 eyes), including 6 females and 2 males, who were diagnosed with AMN in the neuro-ophthalmology department of Xi'an No.1 Hospital(The First Affiliated Hospital of Northwest University)from December 27, 2022 to February 1, 2023 were included in the study. All patients had a history of SARS-CoV-2 infection before the disease, and the results of best corrected visual acuity(BCVA), non-contact indirect intraocular pressure measurement, fundus color photography, near infrared(IR), spectral-domain optical coherence tomography(SD-OCT), OCT angiography(OCTA), fundus fluorescein angiography(FFA), indocyanine green angiography(ICGA), visual field, visual evoked potential(VEP), and electroretinogram(ERG)were collected. Furthermore, the neuro-opthalmology characteristics of the included patients were analyzed and summarized.RESULTS: The included 8 patients aged from 20 to 43, with an average age of(30±6.63)years old. The patients had a history of SARS-CoV-2 infection 3 to 11(mean 5±3.51)d before the disease, and 6 out of 8 patients developed visual symptoms within 5 d of infection with SARS-CoV-2, with manifestated with decreased vision or visual scotoma. The visual acuity varied from 0.08 to 1.0, with visual field defect characterized by central, paracentral or peripheral scotoma. VEP showed prolongation latency of P100 or P2, and ERG revealed impaired function of retinal photoreceptor cell. In the early stage of the disease, the size and shape of early visual acuity, visual field, and extraretinal lesions in patients with AMN associated with SARS-CoV-2 infection may not match, and the lower the visual acuity, the later the VEP peaks.CONCLUSION: The neuro-ophthalmic features of SARS-CoV-2 infection-associated AMN require the attention of clinicians. In addition to multi-mode fundus imaging, clinicians should use a variety of methods to comprehensively evaluate visual function and prognosis of patients.
6.Changes of laboratory biochemical indicators in HIV / AIDS patients treated with different antiviral regimens
Mengxue LI ; Jiafa LIU ; Rui ZHANG ; Zhixing WU ; Jianjian LI ; Xuemei DENG ; Kailin YANG ; Xingqi DONG ; Mi ZHANG
Journal of Public Health and Preventive Medicine 2024;35(4):49-52
Objective To analyze the changes of liver and kidney function, blood glucose and lipid metabolism at different follow-up time points of different treatment regimens, and to provide reference for clinical optimization and adjustment of medication in HIV/AIDS patients. Methods The changes of liver and kidney function, blood glucose and lipid metabolism at seven follow-up time points were analyzed retrospectively. The baseline blood collection time of HIV /AIDS patients was set as the starting point, and the final follow-up time was set as the end point. The seven follow-up points were 0, 3, 6, 9, 12, 18 and 24 months respectively. Results There were statistically significant differences in the distribution of sex, age, education, marital status, WHO staging, infection route, and baseline CD4+T lymphocyte count among 605 enrolled patients based on different treatment regimens. Liver function: The level of T-Bil in group E was higher than that of baseline at 9M, 12M, 18M and 24M after treatment (P<0.01); In group F, the level of T-Bil was higher than that of baseline at 9M after treatment (P=0.001); The levels of ALT in group C at the six follow-up points after treatment were higher than the baseline (P<0.001); The level of AST in group C was higher than that of baseline after 3M and 6M treatment (P<0.05). Renal function: The level of UREA in group C was higher than that in baseline after 6M treatment (P=0.007); The level of UREA in group F was higher than that in the baseline after 12M treatment (P<0.001); The level of UA in group F was higher than that of baseline after 3M, 6M and 12M treatment (P<0.05). Blood lipid and blood glucose: The levels of Glu at some follow-up points after ART treatment in group A and group C were higher than that at baseline (P<0.05); The levels of TG at some follow-up points in group A, group E and group F after ART treatment were higher than those at baseline (P<0.05); The levels of TC at some follow-up points in group A, group B, group C, group E and group F after ART treatment were all higher than the baseline (P<0.05). Conclusion Regular monitoring of changes in laboratory indicators of different treatment regimens during ART is of great importance to the prognosis of patients. Different laboratory indicators should be monitored according to different treatment regimens to effectively prevent adverse reactions caused by different treatment regimens.
7.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
8.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
9.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
10.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.


Result Analysis
Print
Save
E-mail