1.Analysis on Determination and Quantity Transfer of Standard Decoction of Ginseng Radix et Rhizoma by Fresh and Traditional Cutting
Xuejing ZHANG ; Mengdan XU ; Xiaokang LIU ; Juan SHAO ; Mengqi LU ; Xiaoyan XIE ; Guangzhi CAI ; Jiyu GONG
Chinese Journal of Experimental Traditional Medical Formulae 2024;30(9):132-140
		                        		
		                        			
		                        			ObjectiveTo analyze the quantity-quality transfer of standard decoction of Ginseng Radix et Rhizoma(GRR) decoction pieces produced by fresh and traditional cutting, and to provide reference for quality control and application development of the decoction pieces produced by fresh cutting. MethodTen batches of representative GRR decoction pieces produced by fresh and traditional cutting and their standard decoctions were prepared by standard process, and high performance liquid chromatography(HPLC) fingerprint of the standard decoction was established and performed on an Agilent EC-C18 column(4.6 mm×150 mm, 2.7 μm) with acetonitrile(A)-0.1% phosphoric acid aqueous solution(B) as the mobile phase for gradient elution(0-23 min, 18%-21%A; 23-35 min, 21%-28%A; 35-80 min, 28%-32%A), and the detection wavelength was 203 nm. Then similarity evaluation, principal component analysis(PCA) and partial least squares-discriminant analysis(PLS-DA) of fingerprint of the standard decoction were performed to screen the differential components with variable importance in the projection(VIP) value>1. Quantitative analysis was carried out on the screened known differential components, and combined with the indicators of the dry extract rate and the transfer rate, to explore the differences in the quantity-quality transfer between the standard decoction of GRR decoction pieces produced by fresh and traditional cutting. ResultThe fingerprint similarity of the standard decoction of GRR decoction pieces produced by fresh and traditional cutting was more than 0.950, and 18 common peaks were identified, including 9 identified common peaks. The results of PCA and PLS-DA showed that there were some differences in the contents of index components between the two standard decoctions. The contents of ginsenoside Rg1, Re and Ro in GRR decoction pieces produced by fresh cutting were higher than those in traditional decoction pieces, while the contents of ginsenoside Rb1, Rc , Rb2 and Rd were lower than those in traditional decoction pieces. The contents of ginsenoside Rg1, Re, Rb1 and Ro in the standard decoction of GRR decoction pieces produced by fresh cutting were higher than those in the standard decoction of traditional decoction pieces, while the contents of ginsenoside Rc , Rb2 and Rd were comparable between the two standard decoctions. Compared with the standard decoction of the traditional decoction pieces, the average transfer rates of ginsenoside Rg1, Rb1, Rc, Rb2 and dry extract rate of the standard decoction of GRR decoction pieces produced by fresh cutting were significantly increased(P<0.05), and the average transfer rate of ginsenoside Re and Rd also increased, but the difference was not statistically significant. ConclusionThe dry extract rate, content and transfer rate of index components of standard decoction of GRR decoction pieces produced by fresh cutting are better than those of the standard decoction of traditional decoction pieces, which can provides data support for the subsequent clinical application of fresh cutting products. 
		                        		
		                        		
		                        		
		                        	
2.Clinical and pathological features of 52 patients with glomerulonephritis with dominant C3
Jinying WEI ; Yao HUANG ; Shuguang YUAN ; Xiaojun CHEN ; Xiao FU ; Zheng LI ; Ying LI ; Lin SUN ; Hong LIU ; Xuejing ZHU
Journal of Central South University(Medical Sciences) 2024;49(1):75-83
		                        		
		                        			
		                        			Objective:With the in-depth study of complement dysregulation,glomerulonephritis with dominant C3 has received increasing attention,with a variety of pathologic types and large differences in symptoms and prognosis between pathologic types.This study analyzes the clinical,pathological,and prognostic characteristics of different pathological types of glomerulonephritis with dominant C3,aiming to avoid misdiagnosis and missed diagnoses. Methods:The clinical,pathological,and follow-up data of 52 patients diagnosed as glomerulonephritis with dominant C3 by renal biopsy from June 2013 to October 2022 were retrospectively analyzed.According to the clinical feature and results of pathology,15 patients with post-infectious glomerulonephritis(PIGN)and 37 patients with of non-infectious glomerulonephritis(N-PIGN)were classified.N-PIGN subgroup analysis was performed,and 16 patients were assigned into a C3-alone-deposition group and 21 in a C3-dominant-deposition group,or 27 in a C3 glomerulopathy(C3G)group and 10 in a non-C3 nephropathy(N-C3G)group. Results:The PIGN group had lower creatinine values(84.60 μmol/L vs 179.62 μmol/L,P= 0.001),lower complement C3 values(0.36 g/L vs 0.74 g/L,P<0.001)at biopsy,and less severe pathological chronic lesions compared with the N-PIGN group.In the N-PIGN subgroup analysis,the C3-dominant-deposition group had higher creatinine values(235.30 μmol/L vs 106.70 μmol/L,P=0.004)and higher 24-hour urine protein values(4 025.62 mg vs 1 981.11 mg,P=0.037)than the C3-alone-deposition group.The prognosis of kidney in the PIGN group(P=0.049),the C3-alone-deposition group(P=0.017),and the C3G group(P=0.018)was better than that in the N-PIGN group,the C3-dominant-deposition group,and the N-C3G group,respectively. Conclusion:Glomerulonephritis with dominant C3 covers a variety of pathological types,and PIGN needs to be excluded before diagnosing C3G because of considerable overlap with atypical PIGN and C3G;in addition,the deposition of C1q complement under fluorescence microscope may indicate poor renal prognosis,and relevant diagnosis,treatment,and follow-up should be strengthened.
		                        		
		                        		
		                        		
		                        	
3.Huatan Qushi formula alleviates non-alcoholic fatty liver disease via PI3K/Akt signaling and gut microbiota modulation
Xiuping Zhang ; Linghui Zhu ; Jinchen Ma ; Yi Zheng ; Xuejing Yang ; Lingling Yang ; Yang Dong ; Yan Zhang ; Baoxing Liu ; Lingru Li
Journal of Traditional Chinese Medical Sciences 2024;11(4):443-455
		                        		
		                        			Objective:
		                        			To provide the mechanism-based pharmacotherapy of the Huatan Qushi formula (HTQS formula), for the health management and treatment of non-alcoholic fatty liver disease (NAFLD).
		                        		
		                        			Methods:
		                        			A rat model of NAFLD was employed to examine the efficacy and safety of the HTQS formula. In vivo active components and potential mechanisms of the HTQS formula were identified using UPLC‒MS/MS combined with network pharmacology. The influence of the HTQS formula on the dominating proteins in PI3K/Akt pathway was validated in vivo using western blot. Finally, 16S rRNA sequencing of the gut microbiome was conducted followed by targeted metabolomics detecting fecal short-chain fatty acids (SCFAs) and bile acids to determine the impact of the HTQS formula on gut microbiota.
		                        		
		                        			Results:
		                        			The HTQS formula reduced weight gain and hepatic steatosis in NAFLD rats and decreased serum total cholesterol (TC), triglycerides, blood glucose, and insulin resistance (IR) without causing liver or kidney injury. We detected 28 components using UPLC‒MS/MS and identified 439 shared targets between NAFLD and the HTQS formula. Primarily, we focused on the PI3K/Akt signaling pathway based on protein‒protein interaction network analysis. We validated that the HTQS formula inhibited liver steatosis and inflammation by increasing the phosphorylation levels of PI3K, AKT, P27, GSK3β in the PI3K/Akt signaling pathway. 16S rRNA sequencing revealed that the HTQS formula reduced the abundance of the genus Family_XIII_AD3011_group, which was positively correlated with IR and taurodeoxycholic acid. In addition, Lachnospiraceae_UCG_010 inversely correlated with TC and five bile acids, which could be essential to the therapeutic effect of the HTQS formula against NAFLD.
		                        		
		                        			Conclusions
		                        			The HTQS formula proved to be an effective pharmacotherapy for NAFLD without causing liver or kidney injury. Multiple potent components of the HTQS formula could alleviate liver steatosis and lipid metabolism disorder by modulating the PI3K/Akt signaling pathway and restoring gut microbiota composition.
		                        		
		                        		
		                        		
		                        	
4.Comfort efficacy of gene-transfected pig skin in arc burn patients
Qian WANG ; Xuejing DUAN ; Hongwei HA ; Yuhui ZHAO ; Guiling WANG ; Jun LIU
Journal of Army Medical University 2024;46(23):2649-2654
		                        		
		                        			
		                        			Objective To observe the comfort effect of gene-transfected pig skin in patients with arc burn wound.Methods A total of 56 patients with electric arc burn treated in our hospital from June 2020 to December 2022 were enrolled and then randomly divided into treatment group and control group,with 28 cases in each group.Both groups were treated with debridement,including removing pollutants and necrotic skin,and cleaning the wounds with normal saline.After debridement,the shallow second-degree burn wounds in the control group were covered with silver ion functional antibacterial dressing and wrapped with sterile cotton pad,while those in the treatment group were covered with thawed and softened gene-transfected pig skins.For the deep second-degree burn wounds,after simple debridement,the wounds were treated with scab grinding in 48 h after burn when the condition of the patients was stable.After this,the wounds in the control group and the treatment group were treated as the shallow wounds,respectively.Visual Analogue Scale(VAS),State Anxiety Inventory(SAI)score,treatment process satisfaction,patient comfort and time for wound healing were observed and compared between the 2 groups.Results There was no significant difference in the VAS score and SAI score between the 2 groups at the first dressing change(P>0.05),but the VAS score and SAI score were obviously lower in the treatment group than the control group at the second and third dressing changes(P<0.05).The treatment group obtained notably better comfort level and shorter time for wound healing than the control group(P<0.05).Conclusion Gene-transfected pig skin shows good efficacy in the wound surface of arc burn,which can shorten the wound healing time,reduce the pain of dressing change and improve the satisfaction and comfort of patients.
		                        		
		                        		
		                        		
		                        	
5.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
		                        		
		                        			
		                        			【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
		                        		
		                        		
		                        		
		                        	
6.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
		                        		
		                        			
		                        			【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
		                        		
		                        		
		                        		
		                        	
7.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
		                        		
		                        			
		                        			【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
		                        		
		                        		
		                        		
		                        	
8.Clinical analysis of the retinal vein occlusion combined with retinal artery occlusion
Menghan XU ; Hao LIU ; Xuejing ZHENG ; Lihua HOU ; Xiabo LI ; Mei YAN ; Tong LI ; Xin LU ; Min WANG
Chinese Journal of Ocular Fundus Diseases 2024;40(11):848-853
		                        		
		                        			
		                        			Objective:To observe the clinical and imaging features of patients with retinal vein occlusion (RVO) complicated with retinal artery occlusion (RAO).Methods:A retrospective clinical study. Fifteen patients with 15 eyes with RVO combined with RAO and macular edema diagnosed by ophthalmology examination in the Department of Ophthalmology, First People's Hospital of Xianyang City during 2 years from February 1, 2022 to January 31, 2024 were included in the study. Branch retinal vein occlusion (BRVO) combined with branch retinal artery occlusion (BRAO) occurred in 3 cases and 3 eyes. Central retinal vein occlusion (CRVO) complicated with central retinal artery occlusion (CRAO) in 12 eyes. Best corrected visual acuity (BCVA), intraocular pressure, scanning laser ophthalmoscope, optical coherence tomography (OCT), fluorescein fundus angiography (FFA) and serum homocysteine were all performed. OCT angiography (OCTA) was performed in 6 eyes. All eyes were treated with intravitreal injection of anti-vascular endothelial growth factor drugs. After the initial 1 treatment, dosage was assessed as needed. Follow-up was performed every month for 12 months after treatment. FFA inspection was performed at 3 months. During follow-up, it was found that there were no perfusion areas of capillaries, and retinal laser photocoagulation therapy was given in time. Fundus manifestations, FFA, OCT, OCTA characteristics and causes of disease were analyzed retrospectively.Results:There were 15 eyes in 15 cases, 9 eyes in 9 males; 6 women with 6 eyes. Age was (61.0±9.7) years. All complained of painless vision loss in one eye. All eyes were positive for relative afferent pupillary disorder. Contralateral congenital optic disc defect was in 1 case; hypertension was in 6 cases; hyperhomocysteinemia was in 2 cases; cerebral infarction was in 3 cases; coronary heart disease was in 1 case. CRVO combined with CRAO was in 12 eyes BCVA light sensitivity-0.25. The BCVA of BRVO combined with BRAO were 0.1, 0.4 and 0.25, respectively. All the patients had retinal edema in the posterior pole of the eye, venous sinuous, dilated, thin arteries and stiff shape. The retina presents with flaky or flame-like bleeding. Posterior polar retinal lint patch was in 13 eyes. In 12 eyes with CRVO combined with CRAO, optic disc edema was observed and the boundary was not clear. In 3 eyes with BRVO combined with BRAO, no obvious abnormality was found in the optic disc, and the boundary was clear. FFA examination showed no or prolonged arterial filling, delayed retinal vein laminar flow, relatively slow or even no capillary filling, macular arteriole atretosis to varying degrees, arch ring structure destruction, optic disc telangiectasia and fluorescein leakage. OCT examination showed that the middle and inner layers of the retina were thickened to varying degrees, the diffuse reflex was enhanced, the interlayer structure was unclear, and the reflex of the lower retinal tissue was weakened. The blood flow density of superficial capillary plexus and deep capillary plexus (DCP) decreased in 6 eyes undergoing OCTA examination. Decreased or interrupted blood flow in the vascular bed of DCP. During the follow-up period, there were 13 eyes with no perfusion area of retinal capillary. The time of occurrence was (1.14±0.95) (0-2) months, and the area was 10-75 disc area. Optic nerve atrophy occurred in 5 eyes. At the last follow-up, visual acuity increased, unchanged and decreased in 12, 2 and 1 eyes, respectively.Conclusions:The pathogenesis of RVO-RAO is complicated. Most RVO and RAO occurred simultaneously, and a few RVO occurred several days after RAO. Although the RAO manifestations are not typical, the radiographic features are both RVO and RAO. Compared with BVRO combined with BRAO, the prognosis of visual acuity in CRAO patients with CRVO is worse.
		                        		
		                        		
		                        		
		                        	
9.Relationship among spontaneous turning direction, balance and fall risk in stroke patients during walking
Xiaomin ZHU ; Huilin LIU ; Yuanmin LIU ; Zhiyu YAN ; Xuejing DU ; Ya'nan WANG ; Tong ZHANG
Chinese Journal of Rehabilitation Theory and Practice 2023;29(5):510-515
		                        		
		                        			
		                        			ObjectiveTo investigate the relationship among spontaneous turning direction, balance ability and fall risk in patients with stroke during walking. MethodsFrom December, 2021 to November, 2022, 94 patients with stroke were recruited from Beijing Bo'ai Hospital. They were assessed with simple Timed 'Up and Go' Test (TUGT, TUGT1), TUGT with a cup in hand (TUGT2), and TUGT with calculation task (TUGT3). The spontaneous turning directions at the turn point were recorded, and the patients were divided into no-same group (n = 34) and same group, and the same group was further divided into affected group (n = 33) and unaffected group (n = 27), according to the spontaneous turning direction. After a spontaneous turning of each TUGT, the patients were asked to finish another TUGT turning to the opposite direction. And then, they were assessed with single leg standing test, Functional Reach Test (FRT), 360° turning test and the Morse Fall Scale (MFS). ResultsThere were the most patients with left hemiplegia in the affected group (χ2 = 7.995, P < 0.05). The time of TUGT1, TUGT2 and TUGT3 was the most in the affected group and the least in the unaffected group (F > 4.009, P < 0.05), and it was more in the affected group than in the unaffected group as post-hoc test (P < 0.05). The one leg standing time (H = 9.403, P = 0.009) and FRT distance (F = 4.300, P = 0.016) were the least in the affected group and the most in the unaffected group, and it was less in the affected group than in the unaffected group as post-hoc test (P < 0.05). The turning time (F = 4.134, P = 0.019) and turning steps (F = 5.611, P = 0.003) were the most in the affected group and the least in the unaffected group, and it was more in the affected group than in the unaffected group as post-hoc test (P < 0.05). The score of MFS was the most in the affected group and the least in the unaffected group (H = 8.192, P = 0.017), and it was more in the affected group than in the unaffected group as post-hoc test (P < 0.05). ConclusionThe stroke patients spontaneously turning to the affected side during walking usually are poorer in balance function, and in a risk of fall. 
		                        		
		                        		
		                        		
		                        	
10.LPS adsorption and inflammation alleviation by polymyxin B-modified liposomes for atherosclerosis treatment.
Huiwen LIU ; Honglan WANG ; Qiyu LI ; Yiwei WANG ; Ying HE ; Xuejing LI ; Chunyan SUN ; Onder ERGONUL ; Füsun CAN ; Zhiqing PANG ; Bo ZHANG ; Yu HU
Acta Pharmaceutica Sinica B 2023;13(9):3817-3833
		                        		
		                        			
		                        			Chronic inflammation is critical in the onset and progression of atherosclerosis (AS). The lipopolysaccharide (LPS) level in the circulation system is elevated in AS patients and animal models, which is correlated with the severity of AS. Inspired by the underlying mechanism that LPS could drive the polarization of macrophages toward the M1 phenotype, aggravate inflammation, and ultimately contribute to the exacerbation of AS, LPS in the circulation system was supposed to be the therapeutic target for AS treatment. In the present study, polymyxin (PMB) covalently conjugated to PEGylated liposomes (PLPs) were formulated to adsorb LPS through specific interactions between PMB and LPS. In vitro, the experiments demonstrated that PLPs could adsorb LPS, reduce the polarization of macrophages to M1 phenotype and inhibit the formation of foam cells. In vivo, the study revealed that PLPs treatment reduced the serum levels of LPS and pro-inflammatory cytokines, decreased the proportion of M1-type macrophages in AS plaque, stabilized AS plaque, and downsized the plaque burdens in arteries, which eventually attenuated the progression of AS. Our study highlighted LPS in the circulation system as the therapeutic target for AS and provided an alternative strategy for AS treatment.
		                        		
		                        		
		                        		
		                        	
            

Result Analysis
Print
Save
E-mail