1.Analysis of clinical characteristics and prognosis of patients with newly diagnosed mul-tiple myeloma with thrombocytopenia
Qin XIAOQI ; Xia LING ; Niu YUANMAN ; Xie XINNA ; Wang SHIFANG ; Guo QIAOHUA ; Ma YANPING
Chinese Journal of Clinical Oncology 2024;51(12):607-610
Objective:To investigate the clinical characteristics and prognosis of patients with newly diagnosed multiple myeloma(NDMM)with thrombocytopenia.Methods:Clinical data of 529 patients with NDMM admitted to The Second Hospital of Shanxi Medical University between January 2012 and December 2021 were retrospectively analyzed.The patients were categorized into thrombocytopenia and nor-mal platelet count groups based on their platelet count levels.Results:A total of 529 patients with NDMM were included in this study,with 108(20.42%)patients in the thrombocytopenia group.The median progression-free survival(mPFS)was 30.64 months(95%confidence in-terval[CI]:23.43-37.85)in the thrombocytopenia group,which was shorter than that in the normal platelet count group(41.39 months[95%CI:37.37-45.39],P=0.002).The median overall survival(mOS)was 40.59 months(95%CI:30.61-50.57)in the thrombocytopenia group,which was shorter than that in the normal platelet count group(60.92 months[95%CI:54.54-67.29],P<0.001).Multivariate Cox regression analysis identified thrombocytopenia as a risk factor for OS in patients with NDMM(HR=1.238[95%CI:1.16-1.952],P=0.03).Conclusions:The prognosis of patients with NDMM with thrombocytopenia was worse than that of patients with NDMM who had normal platelet levels.Thrombocytopenia may serve as a poor prognostic indicator for NDMM.
2. Pathogen spectrum of viral encephalitis in children living in Hebei province, China from May to December 2017
Tao FAN ; Yanjie HAN ; Ruiqin ZHANG ; Panhui YU ; Li ZHAO ; Juju QI ; Xinna LI ; Ruihuan WANG ; Yishuo SUN ; Jian ZHAO ; Chuanze HU ; Ji WANG ; Suzhen SUN ; Xuejun MA
Chinese Journal of Experimental and Clinical Virology 2019;33(3):275-279
Objective:
To investigate the pathogenic characteristics of viral encephalitis in children living in Hebei province.
Methods:
We randomly collected cerebrospinal fluid specimens from a total of 399 children diagnosed with viral encephalitis in Hebei Children′s Hospital from May to December 2017. Real-time fluorescence quantitative PCR and Sanger sequencing were used to detect viral nucleic acids in cerebrospinal fluid by an automatic laboratory station. Statistical analysis was performed on the experimental data using SPSS 21.0 software and the clinical data were analyzed. Comparison of infection rates of EV encephalitis in different months, using line × column chi-square test. The MRI and EEG positive rates of different viral encephalitis and viral encephalitis patients not infected with the virus were analyzed by Fisher′s exact probability test. The positive rate of infection with different viruses and non-virus agents was analyzed by Fisher′s exact probability test.
Results:
The result showed that 80 of 399 samples were positive, and the positive rate was 20.05%. It included 22 cases of enterovirus, 4 cases of influenza A virus, 3 cases of mumps virus, 2 cases of herpes simplex virus type 1, 1 case of herpes simplex virus type 2, 4 cases of EB virus, 7 cases of cytomegalovirus, 7 cases of herpes zoster virus, 8 cases of adenovirus, 14 cases of human herpesvirus type 6. Eight cases had combined viral infection. Eight cases had concurrent infections: 3 cases had enterovirus and herpesvirus type 6 concurrent infection, 1 case had enterovirus and Japanese encephalitis virus concurrent infection and 1 case had herpes simplex virus type 2 and adenovirus, 1 case had influenza A virus herpesvirus type 6, 1 case had mumps virus and herpesvirus type 6, 1 case had mumps virus and herpesvirus type 6, 1 case had herpes simplex virus type 1 and herpes zoster virus concurrent infections. Children with EV viral encephalitis in Hebei Province were highly prevalent in May and June (
3. Development and evaluation of real-time fluorescence recombinase aided amplification assay without extracting nucleic acid for detection of adenovirus type 3
Ruihua WANG ; Yi ZHANG ; Xingyu XIANG ; Zhifei ZHAN ; Xinna LI ; Xinxin SHEN ; Zhen ZHU ; Ruiqing ZHANG ; Xueding BAI ; Qingxia DUAN ; Guohao FAN ; Hong ZHANG ; Xuejun MA
Chinese Journal of Experimental and Clinical Virology 2019;33(6):653-657
Objective:
To establish a real-time fluorescence recombinase acid amplification (RAA) method for the detection of adenovirus type 3(HAdV-3)without extraction nucleic acid.
Methods:
According to the conserved sequence of adenovirus type 3 gene, a pair of primers and a probe were designed, and a real-time fluorescence RAA without extracting nucleic acid was established and optimizing the condition of DNA-free extraction. The sensitivity of the method was analyzed by a series of dilution and the specificity of the method was evaluated by detecting the original samples of other respiratory viruses. The clinical samples of HAdV-3 were detected and compared with the traditional real-time fluorescence quantitative PCR method for nucleic acid extraction.
Results:
The sensitivity of the real-time fluorescence RAA method was as high as that of qPCR in the detection of 10 series diluted HAdV-3 strains. The highest corresponding CT value of qPCR was 36.87. The sensitivity of the real-time fluorescence RAA method was similar to that of the real-time fluorescence quantitative PCR method . There was no cross-reaction to other common types of respiratory viruses. The two method were used to detect 56 clinical samples at the same time, and the result were completely consistent.
Conclusions
We provide the first report of the real-time fluorescent RAA assays for the detection of HAdV-3 without extracting nucleic acid and it has high sensitivity and specificity. Is suitable for rapid detection of HAdV-3 in clinical laboratories and on-site unite.
4. Loop-mediated isothermal amplification technique in the diagnosis of hepatitis B virus infection: a Meta-analysis
Hangyu ZHOU ; Chen CHEN ; Xinna LI ; Xuejun MA
Chinese Journal of Preventive Medicine 2017;51(6):562-567
Objective:
To evaluate the diagnostic performance of Loop-mediated isothermal amplification (LAMP) in the diagnosis of Hepatitis B Virus (HBV) infection using Meta-analysis.
Methods:
Literatures about LAMP in the diagnosis of HBV throughPubMed database of the National Library of Medicine, the EMBASE database of the Dutch Medical Digest, the Cochrane Clinical Trials Database, China Science Periodical Database, CSPD and the China National Knowledge Infrastructure (CNKI) were searched from 2000 to 2016, and the Language limited to Chinese and English. English search terms include: LAMP, Loop-mediated isothermal amplification, HBV, hepatitis B virus; Chinese search terms include: loop-mediated isothermal amplification technology, HBV, hepatitis B virus. The keywords and free words are combined to search the literature, and the references mentioned in the retrieval literature are searched twice. The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio (DOR), Q index as well as area under summary receiver operating characteristic curve (SROC) were calculated with Stata 12.0 software.
Results:
A total of 12 literatures with 1 494 cases were included. The pooled sensitivity, specificity, positive likelihood ratio and negative likelihood ratio were 0.922 (95
5.Detection of the Zaire Subtype of the Ebola Virus by Isothermal Multiple Self-matching Initiated Amplification.
Xinna LI ; Kai NIE ; Ji WANG ; Dan ZHANG ; Li GUAN ; Jun LIU ; Yuehua KE ; Hangyu ZHOU ; Xuejun MA
Chinese Journal of Virology 2016;32(1):1-7
Given the Ebola outbreak in West Africa and the risks of spread to other regions, a rapid, sensitive and simple method for the detection of the Ebola virus (EBOV) is of great significance for the prevention and control of Ebola. We developed a simple colorimetric isothermal multiple self-matching initiated amplification (IMSA) for rapid detection of the Zaire subtype of the Ebola virus (EBOV-Z). This method employed six primers that recognized seven sites of the EBOV-Z nucleoprotein gene for amplification of nucleic acids under isothermal conditions at 63 degrees C for 1 h. Amplification products were detected through visual inspection of color change by pre-addition of hydroxyl naphthol blue dye. Relative sensitivity was validated by detection of serial tenfold dilutions of virus-like particles containing the partial EBOV-Z nucleoprotein gene and mock clinical sample. Specificity of IMSA was validated by detection of the plasma of 30 healthy volunteers, the dengue virus, and Japanese encephalitis virus. IMSA had comparable sensitivity to Reverse transcription-quantitative polymerase chain reaction (RT-qPCR), and cross-reaction with human plasma or other viruses was not observed. Reverse transcription-isothermal multiple self-matching initiated amplification (RT-IMSA) was also evaluated and compared in parallel with the commercial RT-qPCR kit for detection of EBOV-suspected samples of human blood in Sierra Leone. Sensitivity and specificity of the RT-IMSA was 91.4% and 100%, respectively. These data suggest that RT-IMSA is a valuable tool for the detection of the EBOV with the distinct advantages of simplicity and low cost compared with RT-qPCR.
Colorimetry
;
methods
;
DNA Primers
;
genetics
;
Ebolavirus
;
genetics
;
isolation & purification
;
Hemorrhagic Fever, Ebola
;
diagnosis
;
virology
;
Humans
;
Nucleic Acid Amplification Techniques
;
methods
6.Detection of Middle East Respiratory Syndrome Coronavirus by Reverse-transcription Loop-Mediated Isothermal Amplification.
Guan LI ; Kai NIE ; Dan ZHANG ; Xinna LI ; Yanqun WANG ; Wenjie TAN ; Xuejun MA
Chinese Journal of Virology 2015;31(3):269-275
A simple, rapid and sensitive colorimetric reverse-transcription loop-mediated isothermal amplification (RT-LAMP) was developed for rapid detection of Middle East respiratory syndrome coronavirus (MERS-CoV). The method employed six primers that recognized sequences of a nucleocapsid gene for amplification of nucleic acids under isothermal conditions at 63 degrees C for 60 min. Products were detected through a LA-320c Loopamp Turbidimeter (real-time RT-LAMP) or visual inspection of color change by pre-addition of Hydroxynaphthol Blue dye (visual RT-LAMP). Specificity of RT-LAMP was validated by detection of several human coronaviruses and common respiratory viruses. MERS-CoV real-time RT-LAMP had a linear correlation (R2) of 0.995 at 10(3)-10(6) copies. The limit of detection of real-time RT-LAMP, visual RT-LAMP and quantitative real-time PCR was 500, 1000 and 100 copies/reaction, respectively. The established RT-LAMP assay was demonstrated to be a rapid screening tool for MERS-CoV infection, and could be suitable in resource-limited clinical sites and for field studies.
Coronavirus Infections
;
virology
;
DNA Primers
;
genetics
;
Humans
;
Middle East Respiratory Syndrome Coronavirus
;
classification
;
genetics
;
isolation & purification
;
Nucleic Acid Amplification Techniques
;
methods
;
Reverse Transcription
7.Colorimetric detection of coxsackievirus A6 by reverse transcription loop mediated isothermal amplification.
Li GUAN ; Songtao XU ; Kai NIE ; Dan ZHANG ; Xinna LI ; Wenbo XU ; Xuejun MA
Chinese Journal of Preventive Medicine 2015;49(11):1009-1013
OBJECTIVETo develop a simple, rapid and sensitive colorimetric reverse-transcription loop-mediated isothermal amplification (RT-LAMP) for rapid detection of coxsackievirus A6 (CV-A6) based on the colour chang of hydroxy naphthol blue (HNB).
METHODSThe method employed a set of six primers that recognized sequences of VP1 gene for amplification of nucleic acid under isothermal conditions at 63 °C for 50 min. The products were detected through visual inspection of color change by the pre-addition of HNB dye. The specificity was validated by detecting a collection of different human enteroviruses. The sensitivity of this assay was evaluated by serial dilutions of RNA molecules from in vitro transcription of CV-A6 VP1 gene, and compared with real-time RT-PCR (rRT-PCR) in parallel. This assay was evaluated with 92 clinical specimens from patients with hand-foot-mouth disease.
RESULTSA positive color (sky blue) was only observed in the preparation of CV-A6, whereas none of the other 23 kinds of human enteroviruses showed a color change. The HNB based RT-LAMP showed a sensitivity of 100 copies/reaction, which was at the same level as that of the rRT-PCR. The result of RT-LAMP in analysis of 92 clinical specimens was consistent with that of the rRT-PCR. The kappa correlation between the two methods was 1 and both of the sensitivity and specificity of the RT-LAMP assay were 100%.
CONCLUSIONThe established RT-LAMP assay had good specificity and sensitivity and thus demonstrated to be a promising screening tool for CV-A6 infection. It also has the potential to be used in resource-limited clinical sites and field study.
Colorimetry ; Coloring Agents ; chemistry ; DNA Primers ; Enterovirus ; isolation & purification ; Hand, Foot and Mouth Disease ; virology ; Humans ; Indicators and Reagents ; chemistry ; Naphthalenesulfonates ; chemistry ; Nucleic Acid Amplification Techniques ; Real-Time Polymerase Chain Reaction ; Reverse Transcription ; Sensitivity and Specificity
8.Colorimetric detection of coxsackievirus A6 by reverse transcription loop mediated isothermal amplification
Li GUAN ; Songtao XU ; Kai NIE ; Dan ZHANG ; Xinna LI ; Wenbo XU ; Xuejun MA
Chinese Journal of Preventive Medicine 2015;49(11):1011-1015
Objective To develop a simple, rapid and sensitive colorimetric reverse-transcription loop-mediated isothermal amplification (RT-LAMP) for rapid detection of coxsackievirus A6 (CV-A6) based on the colour chang of hydroxy naphthol blue (HNB).Methods The method employed a set of six primers that recognized sequences of VP1 gene for amplification of nucleic acid under isothermal conditions at 63 ℃ for 50 min.The products were detected through visual inspection of color change by the pre-addition of HNB dye.The specificity was validated by detecting a collection of different human enteroviruses.The sensitivity of this assay was evaluated by serial dilutions of RNA molecules from in vitro transcription of CV-A6 VP1 gene, and compared with real-time RT-PCR (rRT-PCR) in parallel.This assay was evaluated with 92 clinical specimens from patients with hand-foot-mouth disease.Results A positive color (sky blue) was only observed in the preparation of CV-A6, whereas none of the other 23 kinds of human enteroviruses showed a color change.The HNB based RT-LAMP showed a sensitivity of 100 copies/reaction, which was at the same level as that of the rRT-PCR.The result of RT-LAMP in analysis of 92 clinical specimens was consistent with that of the rRT-PCR.The kappa correlation between the two methods was 1 and both of the sensitivity and specificity of the RT-LAMP assay were 100%.Conclusion The established RT-LAMP assay had good specificity and sensitivity and thus demonstrated to be a promising screening tool for CV-A6 infection.It also has the potential to be used in resource-limited clinical sites and field study.
9.Colorimetric detection of coxsackievirus A6 by reverse transcription loop mediated isothermal amplification
Li GUAN ; Songtao XU ; Kai NIE ; Dan ZHANG ; Xinna LI ; Wenbo XU ; Xuejun MA
Chinese Journal of Preventive Medicine 2015;49(11):1011-1015
Objective To develop a simple, rapid and sensitive colorimetric reverse-transcription loop-mediated isothermal amplification (RT-LAMP) for rapid detection of coxsackievirus A6 (CV-A6) based on the colour chang of hydroxy naphthol blue (HNB).Methods The method employed a set of six primers that recognized sequences of VP1 gene for amplification of nucleic acid under isothermal conditions at 63 ℃ for 50 min.The products were detected through visual inspection of color change by the pre-addition of HNB dye.The specificity was validated by detecting a collection of different human enteroviruses.The sensitivity of this assay was evaluated by serial dilutions of RNA molecules from in vitro transcription of CV-A6 VP1 gene, and compared with real-time RT-PCR (rRT-PCR) in parallel.This assay was evaluated with 92 clinical specimens from patients with hand-foot-mouth disease.Results A positive color (sky blue) was only observed in the preparation of CV-A6, whereas none of the other 23 kinds of human enteroviruses showed a color change.The HNB based RT-LAMP showed a sensitivity of 100 copies/reaction, which was at the same level as that of the rRT-PCR.The result of RT-LAMP in analysis of 92 clinical specimens was consistent with that of the rRT-PCR.The kappa correlation between the two methods was 1 and both of the sensitivity and specificity of the RT-LAMP assay were 100%.Conclusion The established RT-LAMP assay had good specificity and sensitivity and thus demonstrated to be a promising screening tool for CV-A6 infection.It also has the potential to be used in resource-limited clinical sites and field study.
10.Construction of mice angiopoietin-1 gene lentiviral expression vector by Gateway technology and its virus packa-ging
Qiuping LI ; Xinna MA ; Xiaoying ZHANG ; Jing XU ; Shen ZHANG ; Chunzhi WNAG ; Zhichun FENG
Journal of Clinical Pediatrics 2013;(9):866-870
Objective To construct a lentiviral vector carrying angiopoietin-1 (Ang-1) and DsRed gene, and to package a virus particles. Methods The Ang-1 lentiviral vector with DsRed (PLV.Ex3d.P/puro-CMV>Ang-1>IRES/DsRed-Express2) was constructed by Gateway technology, and identiifed by PCR and gene sequencing. The lentiviral vector was mixed with helper vector pLV/helper-SL3, pLV/helper-SL4 and pLV/helper-SL5 by Lipofectamine 2000 to prepare DNA-Lipofectamine?2000 complexes. The complexes were then added to transfect 293FT cells and package virus. The virus titers and infection ef-ifciency were determined by lfuorescence expression. Results Ang-1 lentiviral vector PLV.Ex3d.P/puro-CMV>Ang-1>IRES/DsRed-Express2 was constructed successfully as identified by PCR and gene sequencing. Lentivirus with high-efficiency infection was produced by transfection to 293FT cells and the virus titer was 5×108 TU/ml. Conclusions The recombinant len-tiviral vector for Ang-1 was successfully constructed by Gateway technology and the lentivirus with high-efifciency infection packaging can be used for further experiment of Ang-1 gene.

Result Analysis
Print
Save
E-mail