1.Integrated Optical and Magnetic Navigation for Simplified Percutaneous Transforaminal Endoscopic Lumbar Discectomy: A Novel Approach
Xing-Chen YAO ; Jun-Peng LIU ; Xin-Ru DU ; Li GUAN ; Yong HAI ; Jincai YANG ; Aixing PAN
Neurospine 2025;22(1):297-307
		                        		
		                        			 Objective:
		                        			This study aims to evaluate the clinical benefits of the integrated optical and magnetic surgical navigation system in assisting transforaminal endoscopic lumbar discectomy (TELD) for the treatment of lumbar disc herniation (LDH). 
		                        		
		                        			Methods:
		                        			A retrospective analysis was conducted on patients who underwent TELD for LDH at Beijing Chaoyang Hospital, Capital Medical University from November 2022 to December 2023. Patients treated with the integrated optical and magnetic surgical navigation system were defined as the navigation-guided TELD (Ng-TELD) group (30 cases), while those treated with the conventional x-ray fluoroscopy method were defined as the control group (31 cases). Record and compare baseline characteristics, surgical parameters, efficacy indicators, and adverse events between the 2 patient groups. 
		                        		
		                        			Results:
		                        			The average follow-up duration for the 61 patients was 11.8 months. Postoperatively, both groups exhibited significant relief from back and leg pain, which continued to improve over time. At the final follow-up, patients’ lumbar function and quality of life had significantly improved compared to preoperative levels (p < 0.05). The Ng-TELD group had significantly shorter total operation time (58.43 ± 12.37 minutes vs. 83.23 ± 25.90 minutes), catheter placement time (5.83 ± 1.09 minutes vs. 15.94 ± 3.00 minutes), decompression time (47.17 ± 11.98 minutes vs. 67.29 ± 24.23 minutes), and fewer intraoperative fluoroscopies (3.20 ± 1.45 vs. 16.58 ± 4.25) compared to the control group (p < 0.05). There were no significant differences between the groups in terms of efficacy evaluation indicators and hospital stay. At the final follow-up, the excellent and good rate of surgical outcomes assessed by the MacNab criteria was 98.4%, and the overall adverse event rate was 8.2%, with no statistically significant differences between the groups (p > 0.05). 
		                        		
		                        			Conclusion
		                        			This study demonstrates that the integrated optical and magnetic surgical navigation system can reduce the complexity of TELD, shorten operation time, and minimize radiation exposure for the surgeon, highlighting its promising clinical potential. 
		                        		
		                        		
		                        		
		                        	
2.Integrated Optical and Magnetic Navigation for Simplified Percutaneous Transforaminal Endoscopic Lumbar Discectomy: A Novel Approach
Xing-Chen YAO ; Jun-Peng LIU ; Xin-Ru DU ; Li GUAN ; Yong HAI ; Jincai YANG ; Aixing PAN
Neurospine 2025;22(1):297-307
		                        		
		                        			 Objective:
		                        			This study aims to evaluate the clinical benefits of the integrated optical and magnetic surgical navigation system in assisting transforaminal endoscopic lumbar discectomy (TELD) for the treatment of lumbar disc herniation (LDH). 
		                        		
		                        			Methods:
		                        			A retrospective analysis was conducted on patients who underwent TELD for LDH at Beijing Chaoyang Hospital, Capital Medical University from November 2022 to December 2023. Patients treated with the integrated optical and magnetic surgical navigation system were defined as the navigation-guided TELD (Ng-TELD) group (30 cases), while those treated with the conventional x-ray fluoroscopy method were defined as the control group (31 cases). Record and compare baseline characteristics, surgical parameters, efficacy indicators, and adverse events between the 2 patient groups. 
		                        		
		                        			Results:
		                        			The average follow-up duration for the 61 patients was 11.8 months. Postoperatively, both groups exhibited significant relief from back and leg pain, which continued to improve over time. At the final follow-up, patients’ lumbar function and quality of life had significantly improved compared to preoperative levels (p < 0.05). The Ng-TELD group had significantly shorter total operation time (58.43 ± 12.37 minutes vs. 83.23 ± 25.90 minutes), catheter placement time (5.83 ± 1.09 minutes vs. 15.94 ± 3.00 minutes), decompression time (47.17 ± 11.98 minutes vs. 67.29 ± 24.23 minutes), and fewer intraoperative fluoroscopies (3.20 ± 1.45 vs. 16.58 ± 4.25) compared to the control group (p < 0.05). There were no significant differences between the groups in terms of efficacy evaluation indicators and hospital stay. At the final follow-up, the excellent and good rate of surgical outcomes assessed by the MacNab criteria was 98.4%, and the overall adverse event rate was 8.2%, with no statistically significant differences between the groups (p > 0.05). 
		                        		
		                        			Conclusion
		                        			This study demonstrates that the integrated optical and magnetic surgical navigation system can reduce the complexity of TELD, shorten operation time, and minimize radiation exposure for the surgeon, highlighting its promising clinical potential. 
		                        		
		                        		
		                        		
		                        	
3.Integrated Optical and Magnetic Navigation for Simplified Percutaneous Transforaminal Endoscopic Lumbar Discectomy: A Novel Approach
Xing-Chen YAO ; Jun-Peng LIU ; Xin-Ru DU ; Li GUAN ; Yong HAI ; Jincai YANG ; Aixing PAN
Neurospine 2025;22(1):297-307
		                        		
		                        			 Objective:
		                        			This study aims to evaluate the clinical benefits of the integrated optical and magnetic surgical navigation system in assisting transforaminal endoscopic lumbar discectomy (TELD) for the treatment of lumbar disc herniation (LDH). 
		                        		
		                        			Methods:
		                        			A retrospective analysis was conducted on patients who underwent TELD for LDH at Beijing Chaoyang Hospital, Capital Medical University from November 2022 to December 2023. Patients treated with the integrated optical and magnetic surgical navigation system were defined as the navigation-guided TELD (Ng-TELD) group (30 cases), while those treated with the conventional x-ray fluoroscopy method were defined as the control group (31 cases). Record and compare baseline characteristics, surgical parameters, efficacy indicators, and adverse events between the 2 patient groups. 
		                        		
		                        			Results:
		                        			The average follow-up duration for the 61 patients was 11.8 months. Postoperatively, both groups exhibited significant relief from back and leg pain, which continued to improve over time. At the final follow-up, patients’ lumbar function and quality of life had significantly improved compared to preoperative levels (p < 0.05). The Ng-TELD group had significantly shorter total operation time (58.43 ± 12.37 minutes vs. 83.23 ± 25.90 minutes), catheter placement time (5.83 ± 1.09 minutes vs. 15.94 ± 3.00 minutes), decompression time (47.17 ± 11.98 minutes vs. 67.29 ± 24.23 minutes), and fewer intraoperative fluoroscopies (3.20 ± 1.45 vs. 16.58 ± 4.25) compared to the control group (p < 0.05). There were no significant differences between the groups in terms of efficacy evaluation indicators and hospital stay. At the final follow-up, the excellent and good rate of surgical outcomes assessed by the MacNab criteria was 98.4%, and the overall adverse event rate was 8.2%, with no statistically significant differences between the groups (p > 0.05). 
		                        		
		                        			Conclusion
		                        			This study demonstrates that the integrated optical and magnetic surgical navigation system can reduce the complexity of TELD, shorten operation time, and minimize radiation exposure for the surgeon, highlighting its promising clinical potential. 
		                        		
		                        		
		                        		
		                        	
4.Integrated Optical and Magnetic Navigation for Simplified Percutaneous Transforaminal Endoscopic Lumbar Discectomy: A Novel Approach
Xing-Chen YAO ; Jun-Peng LIU ; Xin-Ru DU ; Li GUAN ; Yong HAI ; Jincai YANG ; Aixing PAN
Neurospine 2025;22(1):297-307
		                        		
		                        			 Objective:
		                        			This study aims to evaluate the clinical benefits of the integrated optical and magnetic surgical navigation system in assisting transforaminal endoscopic lumbar discectomy (TELD) for the treatment of lumbar disc herniation (LDH). 
		                        		
		                        			Methods:
		                        			A retrospective analysis was conducted on patients who underwent TELD for LDH at Beijing Chaoyang Hospital, Capital Medical University from November 2022 to December 2023. Patients treated with the integrated optical and magnetic surgical navigation system were defined as the navigation-guided TELD (Ng-TELD) group (30 cases), while those treated with the conventional x-ray fluoroscopy method were defined as the control group (31 cases). Record and compare baseline characteristics, surgical parameters, efficacy indicators, and adverse events between the 2 patient groups. 
		                        		
		                        			Results:
		                        			The average follow-up duration for the 61 patients was 11.8 months. Postoperatively, both groups exhibited significant relief from back and leg pain, which continued to improve over time. At the final follow-up, patients’ lumbar function and quality of life had significantly improved compared to preoperative levels (p < 0.05). The Ng-TELD group had significantly shorter total operation time (58.43 ± 12.37 minutes vs. 83.23 ± 25.90 minutes), catheter placement time (5.83 ± 1.09 minutes vs. 15.94 ± 3.00 minutes), decompression time (47.17 ± 11.98 minutes vs. 67.29 ± 24.23 minutes), and fewer intraoperative fluoroscopies (3.20 ± 1.45 vs. 16.58 ± 4.25) compared to the control group (p < 0.05). There were no significant differences between the groups in terms of efficacy evaluation indicators and hospital stay. At the final follow-up, the excellent and good rate of surgical outcomes assessed by the MacNab criteria was 98.4%, and the overall adverse event rate was 8.2%, with no statistically significant differences between the groups (p > 0.05). 
		                        		
		                        			Conclusion
		                        			This study demonstrates that the integrated optical and magnetic surgical navigation system can reduce the complexity of TELD, shorten operation time, and minimize radiation exposure for the surgeon, highlighting its promising clinical potential. 
		                        		
		                        		
		                        		
		                        	
5.Integrated Optical and Magnetic Navigation for Simplified Percutaneous Transforaminal Endoscopic Lumbar Discectomy: A Novel Approach
Xing-Chen YAO ; Jun-Peng LIU ; Xin-Ru DU ; Li GUAN ; Yong HAI ; Jincai YANG ; Aixing PAN
Neurospine 2025;22(1):297-307
		                        		
		                        			 Objective:
		                        			This study aims to evaluate the clinical benefits of the integrated optical and magnetic surgical navigation system in assisting transforaminal endoscopic lumbar discectomy (TELD) for the treatment of lumbar disc herniation (LDH). 
		                        		
		                        			Methods:
		                        			A retrospective analysis was conducted on patients who underwent TELD for LDH at Beijing Chaoyang Hospital, Capital Medical University from November 2022 to December 2023. Patients treated with the integrated optical and magnetic surgical navigation system were defined as the navigation-guided TELD (Ng-TELD) group (30 cases), while those treated with the conventional x-ray fluoroscopy method were defined as the control group (31 cases). Record and compare baseline characteristics, surgical parameters, efficacy indicators, and adverse events between the 2 patient groups. 
		                        		
		                        			Results:
		                        			The average follow-up duration for the 61 patients was 11.8 months. Postoperatively, both groups exhibited significant relief from back and leg pain, which continued to improve over time. At the final follow-up, patients’ lumbar function and quality of life had significantly improved compared to preoperative levels (p < 0.05). The Ng-TELD group had significantly shorter total operation time (58.43 ± 12.37 minutes vs. 83.23 ± 25.90 minutes), catheter placement time (5.83 ± 1.09 minutes vs. 15.94 ± 3.00 minutes), decompression time (47.17 ± 11.98 minutes vs. 67.29 ± 24.23 minutes), and fewer intraoperative fluoroscopies (3.20 ± 1.45 vs. 16.58 ± 4.25) compared to the control group (p < 0.05). There were no significant differences between the groups in terms of efficacy evaluation indicators and hospital stay. At the final follow-up, the excellent and good rate of surgical outcomes assessed by the MacNab criteria was 98.4%, and the overall adverse event rate was 8.2%, with no statistically significant differences between the groups (p > 0.05). 
		                        		
		                        			Conclusion
		                        			This study demonstrates that the integrated optical and magnetic surgical navigation system can reduce the complexity of TELD, shorten operation time, and minimize radiation exposure for the surgeon, highlighting its promising clinical potential. 
		                        		
		                        		
		                        		
		                        	
6.Comparison of clinical efficacy and stability of Toric implantable collamer lens implantation in different orientations
Yanfen LIAO ; Nian GUAN ; Zhengwei SHEN ; Xing HE ; Ying LIU
International Eye Science 2024;24(2):210-215
		                        		
		                        			
		                        			 AIM: To compare the clinical efficacy, vault, and rotational stability of horizontal, oblique, and vertical implantation of Toric implantable collamer lens(TICL).METHODS: Retrospective cohort study. A total of 92 cases(120 eyes)who underwent TICL implantation from July 2018 to March 2022 and had regular follow-up for at least 1 a postoperatively(1 d, 1 wk, 1, 3, 6 mo, and 1 a)at Wuhan Bright Eye Hospital were collected. The patients were divided into three groups, with 34 cases(45 eyes)in horizontal implantation group, 25 cases(29 eyes)in oblique implantation group(29 cases), and 33 cases(46 eyes)in vertical implantation group. Uncorrected distance visual acuity(UDVA), corrected distance visual acuity(CDVA), diopters, vault, and rotation angle(deviation of the actual axis of TICL from the expected axis).RESULTS: All surgeries were uneventful, and there were no complications such as infection, secondary glaucoma, or cataract opacity. Safety and efficacy of the surgery: the CDVA of the three groups of patients was better than or equal to the preoperative CDVA at 1 a postoperatively, and there was no statistically significant differences in postoperative UDVA and CDVA of the three groups(P>0.05). The safety index at 1a postoperatively was 1.34±0.21, 1.34±0.17, and 1.31±0.18 for the horizontal, oblique, and vertical groups, respectively. The efficacy index was 1.26±0.21, 1.33±0.18, and 1.27±0.16 for the three groups, respectively, both with no statistically significant differences(P>0.05). Vault: there was a significant difference in postoperative vault among the three groups(P=0.003), with the vertical group having the lowest vault, followed by the horizontal group and the oblique group. The vaults at different follow-up time points within each group showed significant differences(P<0.001), and all decreased over time. Residual astigmatism: there was no significant difference in residual astigmatism among the three groups(P=0.130), but there were differences at different follow-up time points within each group(P<0.001). Rotation angle: no significant differences in rotation angle were observed among the three groups(P=0.135), but there were differences at different follow-up time points within each group(P<0.001).CONCLUSION: The implantation of TICL in different orientations has good safety and efficacy, the postoperative rotational stability is good, and the appropriate angle can be selected to implant TICL according to the clinical situation. 
		                        		
		                        		
		                        		
		                        	
7.Animal models of femoral bone defects:preparation status and characteristics
Shibo ZHOU ; Jianbin GUAN ; Xing YU ; He ZHAO ; Yongdong YANG ; Tao LIU
Chinese Journal of Tissue Engineering Research 2024;28(4):633-638
		                        		
		                        			
		                        			BACKGROUND:The repair and clinical outcome of bone defects remains a hot and difficult area of clinical research,which is a common problem that plagues clinicians.Constructing suitable,reproducible and infinitely close to clinical animal experimental models and their scientific evaluation are essential for further clinical treatment of related diseases. OBJECTIVE:To retrospectively analyze the preparation methods and characteristics of common animal models of femoral bone defects and to assess their strengths and weaknesses,thereby providing some reference for relevant researchers to select appropriate animal models of femoral bone defects. METHODS:PubMed,Web of Science,Medline,and CNKI were retrieved for relevant literature published from January 1,2000 to August 1,2022.The keywords were"bone defect,bone,bones,defect,defects,defective,animal model,animal,model,laboratory,laboratory animal,animal laboratory"in English and"bone defect,animal model,experiment"in Chinese. RESULTS AND CONCLUSION:Twenty-seven randomized controlled animal experiments involving rats,mice,New Zealand rabbits,and sheep were included,analyzed and assessed.The most common types of bone defects were cylindrical bone defects and segmental osteotomy bone defects,generally found in the middle and distal femur.These models are mostly used to evaluate the effects of bone repair materials,drugs,drug-loaded active substances and physical therapy on bone defect repair and explore defect healing mechanisms,particularly the weight-bearing bone defect repair mechanism.Different defect kinds and femoral bone defect ranges have been found in different animal experiments.Researchers can select the suitable animal model and bone defect type based on the goal of the experiment and then set an acceptable bone defect value.Current studies have shown that cylindrical and segmental osteotomy-induced bone defects,mainly in the distal and middle femur,are mostly used in the animal models of femoral bone defects and that the surgical methods and postoperative management are more mature and operable to provide mature experimental animal models.In terms of cylindrical bone defects,rats and New Zealand rabbits are more suitable,whereas segmental osteotomy has no special requirements and all types of animals can meet the experimental requirements.
		                        		
		                        		
		                        		
		                        	
8.Prediction of Screw Loosening After Dynamic Pedicle Screw Fixation With Lumbar Polyetheretherketone Rods Using Magnetic Resonance Imaging-Based Vertebral Bone Quality Score
Guozheng JIANG ; Luchun XU ; Yukun MA ; Jianbin GUAN ; Yongdong YANG ; Wenqing ZHONG ; Wenhao LI ; Shibo ZHOU ; JiaWei SONG ; Ningning FENG ; Ziye QIU ; Zeyu LI ; YiShu ZHOU ; Letian MENG ; Yi QU ; Xing YU
Neurospine 2024;21(2):712-720
		                        		
		                        			 Objective:
		                        			To investigate the correlation between magnetic resonance imaging-based vertebral bone quality (VBQ) score and screw loosening after dynamic pedicle screw fixation with polyetheretherketone (PEEK) rods, and evaluate its predictive value. 
		                        		
		                        			Methods:
		                        			A retrospective analysis was conducted on the patients who underwent dynamic pedicle screw fixation with PEEK rods from March 2017 to June 2022. Data on age, sex, body mass index, hypertension, diabetes, hyperlipidemia history, long-term smoking, alcohol consumption, VBQ score, L1–4 average Hounsfield unit (HU) value, surgical fixation length, and the lowest instrumented vertebra were collected. Logistic regression analysis was employed to assess the relationship between VBQ score and pedicle screw loosening (PSL). 
		                        		
		                        			Results:
		                        			A total of 24 patients experienced PSL after surgery (20.5%). PSL group and non-PSL group showed statistical differences in age, number of fixed segments, fixation to the sacrum, L1–4 average HU value, and VBQ score (p < 0.05). The VBQ score in the PSL group was higher than that in the non-PSL group (3.56 ± 0.45 vs. 2.77 ± 0.31, p < 0.001). In logistic regression analysis, VBQ score (odds ratio, 3.425; 95% confidence interval, 1.552–8.279) were identified as independent risk factors for screw loosening. The area under the receiver operating characteristic curve for VBQ score predicting PSL was 0.819 (p < 0.05), with the optimal threshold of 3.15 (sensitivity, 83.1%; specificity, 80.5%). 
		                        		
		                        			Conclusion
		                        			The VBQ score can independently predict postoperative screw loosening in patients undergoing lumbar dynamic pedicle screw fixation with PEEK rods, and its predictive value is comparable to HU value. 
		                        		
		                        		
		                        		
		                        	
9.Comparison of the efficacy of TiRobot orthopaedic robot assisted F screw technique and inverted triangle parallel nail internal fixation in the treatment of unstable femoral neck fractures
Xing-Long ZHAO ; Jian-Jun SHEN ; Kang-Hu FENG ; Zhi-Wei CHEN ; Yuan-Long SI ; Xuan ZHANG ; Guan-De WANG ; Xiang HAI
China Journal of Orthopaedics and Traumatology 2024;37(2):129-134
		                        		
		                        			
		                        			Objective To compare the effectiveness of TiRobot assisted F screw technique and inverted triangle parallel nail internal fixation in the treatment of unstable femoral neck fractures.Methods A retrospective analysis was conducted on 72 patients with unstable femoral neck fractures who were treated with percutaneous cannulated screw fixation assisted with TiRobot Orthopaedic robot from December 2019 to April 2021.Among them,37 patients were treated with F screw internal fixa-tion,including 16 males and 21 females,aged47 to 64years old with an average of(53.87±5.28)years old;According to Pauwels classification,there were 1 case of type Ⅰ,19 cases of type Ⅱ,17 cases of type Ⅲ;8 cases of combined medical diseases;17 cases of falling,8 cases of traffic accident and 12 cases of falling from height;The time from injury to operation was 29 to 49 hours with average of(35.00±7.34)hours.Another 35 cases used internal fixation with an inverted triangle parallel nail,including 13 males and 22 females with an average age of 46 to 63 years old(52.36±5.05)years old;According to the Pauwels injury classifi-cation:there were 2 cases of type Ⅰ,21 cases of type Ⅱ,12 cases of type Ⅲ;6 cases of medical diseases,15 cases of falling in-jury,9 cases of traffic accident,11 cases of falling injury;The time from injury to operation was 30 to 45 hours with an average of(33.00±6.83)h.The intraoperative blood loss,operation time,intraoperative fluoroscopy times,follow-up time,fracture healing time,postoperative complications were observed and compared between the two groups.The hip joint function was e-valuated by Harris score at 6 months and 12 months after operation.Results There was no significant difference in operation time,intraoperative blood loss,intraoperative fluoroscopy times and other intraoperative data between two groups(P>0.05).Both groups were followed up regularly,and the follow-up time was 12 to 16 months.The fracture healing time and Harris score of the F screw internal fixation group were better than those of the inverted triangle parallel nail internal fixation group(P<0.05).There was 1 case of femoral neck shortening in the F screw internal fixation group,1 case of nonunion,1 case of nail withdrawal,and 1 case of lower extremity deep vein thrombosis in the inverted triangle internal fixation group.The incidence of complications in the F screw internal fixation group was lower than that in the inverted triangle parallel nail internal fixation group(P<0.05).Conclusion Percutaneous cannulated F screw technique using Tirobot navigation positioning system is a safe and effective treatment for patients with unstable femoral neck fractures.It can significantly shorten the fracture healing time,reduce the incidence of postoperative complications,significantly improve hip joint function,and improve the quality of life.
		                        		
		                        		
		                        		
		                        	
10.Application of polyetheretherketone rod semi-rigid pedicle screw internal fixation in lumbar non-fusion surgery
Tao LIU ; Xing YU ; Jian-Bin GUAN ; Yong-Dong YANG ; He ZHAO ; Ji-Zhou YANG ; Yi QU ; Feng-Xian WANG ; Ding-Yan ZHAO ; Zi-Yi ZHAO
China Journal of Orthopaedics and Traumatology 2024;37(7):676-683
		                        		
		                        			
		                        			Objective To investigate the effect of Polyetheretherketone(PEEK)rod semi-rigid pedicle screw fixation sys-tem in lumbar spine non-fusion surgery.Methods A total of 74 patients with tow-level lumbar degenerative diseases who un-derwent surgery from March 2017 to December 2019 were divided into PEEK rod group and titanium rod group.In the PEEK rod group,there were 34 patients,including 13 males and 21 females,aged from 51 to 79 years old with an average of(62.4±6.8)years old;There were 1 patient of L1-L3 segments,7 patients of L2-L4 segments,20 patients of L3-L5 segments and 6 pa-tients of L4-S1 segments.In the titanium rod group,there were 40 patients,including 17 males and 23 females,aged from 52 to 81 years old with an average of(65.2±7.3)years old;There were 3 patient of L1-L3 segments,11 patients of L2-L4 segments,19 patients of L3-L5 segments and 7 patients of L4-S1 segments.The general conditions of operation,such as operation time,intraoperative blood loss,postoperative drainage was recorded.The visual analogue scale(VAS)for low back pain and Os-westry disability index(ODI)were compared in preoperatively and postoperatively(3 months,12 months and last follow-up)between two groups.The change of range of motion(ROM)was observed by flexion and extension x-ray of lumbar Results All patients successfully completed the operation.The follow-up time ranged from 22 to 34 months with an average of(26.8±5.6)months.The operative time(142.2±44.7)min and intraoperative blood loss(166.5±67.4)ml in PEEK group were lower than those in titanium group[(160.7±57.3)min、(212.8±85.4)ml](P<0.05).There was no significant differences in postoperative drainage between the two groups(P>0.05).At the final follow-up visit,in PEEK group and titanium group VAS of low back pain[(0.8±0.4)points vs(1.0±0.5)points],VAS for leg pain[(0.7±0.4)points vs(0.8±0.5)points]and ODI[(9.8±1.6)%vs(12.1±1.5)%]were compared with preoperative[(5.8±1.1)points vs(6.0±1.1)points],[(7.2±1.7)points vs(7.0±1.6)points],[(68.5±8.9)%vs(66.3±8.2)%]were significantly different(P<0.05).There was no significant difference in VAS scores between the two groups at each postoperative time point(P>0.05).At 3 months after surgery,there was no difference in ODI between the two groups(P>0.05).There were significant differences in ODI between PEEK group and titanium rod group at 12 months[(15.5±2.1)%vs(18.4±2.4)%]and at the last follow-up[(9.8±1.6)%vs(12.1±1.5)%](P<0.05).The total range of motion(ROM)of lumbar decreased in both groups after surgery.At 12 months after surgery and the last follow-up,the PEEK group compared with the titanium rod group,the total range of motion of lumbar was statistically significant(P<0.05).The range of motion(ROM)of the fixed segments decreased in both groups after surgery.The ROM of the fixed segments in PEEK group decreased from(9.5±4.6)° to(4.1±1.9)° at the last follow-up(P<0.05),which in the titanium rod group was de-creased from(9.8±4.3)°to(0.9±0.5)° at the last follow-up(P<0.05).The range of motion(ROM)of upper adjacent segment increased in both groups,there was statistical significance in the ROM of upper adjacent segment between the two groups at 12 months after surgery and the last follow-up,(P<0.05).There was no screw loosening and broken rods in both groups during the follow-up period.Conclusion The PEEK rod semi-rigid pedicle screw internal fixation system used in lumbar non-fusion surgery can retain part of the mobility of the fixed segment,showing comparable short-term clinical efficacy to titanium rod fu-sion.PEEK rod semi-rigid pedicle screw internal fixation system is a feasible choice for the treatment of lumbar spine degener-ative diseases,and its long-term efficacy needs further follow-up observation.
		                        		
		                        		
		                        		
		                        	
            
Result Analysis
Print
Save
E-mail