1.Rh blood group phenotype distribution in some ethnic groups in China: a meta-analysis
Junyi CHEN ; Mengdan SONG ; Jin MA ; Yongyi YANG ; Xiaojuan LI
Chinese Journal of Blood Transfusion 2025;38(4):562-571
[Objective] To analyze the distribution of Rh blood group phenotype in some ethnic groups in China, so as to provide references for accurate blood transfusion. [Methods] The data of CNKI, Wanfang data and VIP were retrieved using "Rh blood group" and "nationality", and the search of PubMed database was conducted with the keywords "Rh blood group", "nationalities", "ethnic groups" and "China", with retrieval time until September 19, 2024 Data were extracted from eligible studies and the literature quality was evaluated using the criteria for cross-sectional studies in STROBE statement. Meta analysis was performed using Stata 11.0 software. [Results] A total of 350 relevant literature were retrieved, of which 26 were included. The total sample size for Rh phenotype distribution detection were 31 432, and the total population for RhD negative screening was 47 227, covering 26 ethnic groups. Meta-analysis revealed that the Rh blood groups phenotype distribution in certain ethnic populations in China was mainly CCDee 46.7% (95%CI=46.2%-47.2%), CcDEe 30.1% (95%CI=29.5%-30.6%), and CcDee 9.0% (95%CI=8.7%-9.3%). Analysis of the RhD-negative phenotype indicated an negative rate of RhD of 0.3% (95%CI=0.2%-0.3%), with the main phenotype distributions of ccdee at 0.2% (95%CI=0.1%-0.2%) and ccdEe at 0.2% (95%CI=0.0%-0.4%). The meta-analysis results of the distribution of common phenotypes among different ethnic groups showed that the CCDee phenotype was mainly distributed as Hani>Dong>Buyi>Miao>Tujia>Hui>Zang>Kazakh>Mongol>Uygur; the CcDEe phenotype: Zang>Mongol>Hui; the CcDee phenotype: Uygur>Kazakh>Mongol>Zang>Hui>Dong>Miao>Tujia>Buyi; the ccDEE phenotype: Zang>Hui=Mongol. The results of this study are similar to those of Qingdao population in China, but differ from studies conducted in North India, German individuals of European ancestry and Saudi Arabian populations. [Conclusion] The distribution of Rh blood group phenotypes in some ethnic groups in China shows no significant difference compared to the Han population, but there are differences when compared to populations in other countries and regions.
2.The value of HPV DNA and HPV E6/E7 mRNA detection in screening for cervical lesions
Hantao SONG ; Xiaojuan LIU ; Fang LIU ; Li CHANG ; Jie TENG
International Journal of Laboratory Medicine 2024;45(4):467-470
Objective To investigate the value of human papillomavirus(HPV)DNA and HPV E6/E7 mRNA detection in screening for cervical lesions.Methods A total of 619 patients who were screened for cer-vical lesions in West China Second University Hospital from September 2021 to August 2022 were selected as the study objects.The value of HPV DNA and HPV E6/E7 mRNA detection in cervical lesion screening was evaluated based on their pathological results.Results The positive rate of HPV DNA detection was 64.78%(401/619)and that of HPV E6/E7 mRNA detection was 60.74%(376/619)in 619 patients.Cervical lesion screening was mainly conducted in sexually active people aged 30-<40 years and 40-<50 years.The posi-tive rates of HPV DNA and HPV E6/E7 mRNA increased with the increase of cervical lesion grade.The sen-sitivity,positive predictive value and negative predictive value of the two methods were higher than those of HPV DNA or HPV E6/E7 mRNA detection.Conclusion The combined detection of the two methods can be used for screening cervical lesions at various pathological stages,which can provide greater guidance value in clinical diagnosis and treatment.
3.Multivariate analysis of psychological health among hospital infection prevention and control practitioners in Tianjin
He LIU ; Chunnan FEI ; Xiaojuan ZHANG ; Jun LIU ; Jia SONG ; Zheng YAN
Chinese Journal of Industrial Hygiene and Occupational Diseases 2024;42(8):594-597
Objective:To understand the occupational stress and mental health status of hospital infection prevention and control practitioner (HIPCPs) in medical institutions, and analyze their main influencing factors.Methods:In November 2021, 550 nosocomial infection managers in Tianjin were randomly selected to conduct a questionnaire survey using the Concise Occupational Stress Questionnaire, Depression Screening Scale (PHQ-9) and Self-Rating Anxiety Scale (SAS). 497 valid questionnaires were obtained, and the total recovery efficiency was 90.36%. Single factor analysis and multivariate logistic regression method were used to analyze the main influencing factors of occupational stress and mental health status of psychiatric managers.Results:The detection rate of anxiety and depression among 497 HIPCPs was 22.73% (113/497) and 58.95% (293/497), respectively. Gender and major were the influencing factors of depression ( P=0.000, 0.001). Average working hours>52 hours per week and night shift days>1 days per week were the influencing factors of anxiety ( P=0.035, 0.014). Average working hours>52 h per week, night shift days >1 d per week and different majors were the influencing factors of occupational stress ( P=0.000, 0.025, 0.010). Multivariate logistic regression results showed that the risk of anxiety in those who worked more than 52 hours per week was 1.753 times that of those who worked less than 52 hours per week ( P=0.038), and the risk of depression in women was 3.071 times that of men ( P=0.006) . Conclusion:Working hours are an important influencing factor for occupational stress and anxiety among HIPCPs. In order to reduce the occurrence of occupational stress and mental health problems, it is necessary to strengthen psychological counseling for HIPCPs and balance work and rest.
4.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
5.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
6.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
7.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
8.Ameliorative effect and mechanism of emodin on infectious preterm rats
Dingya CAO ; Xiaojuan WU ; Tingting FU ; Bing SONG
China Pharmacy 2024;35(21):2629-2633
OBJECTIVE To explore the ameliorative effect and mechanism of emodin on infectious preterm rats. METHODS The infectious preterm rat model was established and divided into model group, emodin group (60 mg/kg, i.g.), IKK activation group (2 μg pcDNA3.1-IKK recombinant plasmid via tail vein), emodin+IKK activation group (i.g. 60 mg/kg emodin+2 μg pcDNA3.1-IKK recombinant plasmid via tail vein), with 14 rats in each group. Another 14 pregnant female rats were set up as control group. Each group received corresponding intervention for 7 days. The muscle tension of the uterine muscle strip, and the indicator levels of serum inflammation [interleukin 1β (IL-1β), IL-6, tumor necrosis factor α(TNF-α)] and oxidative stress [superoxide dismutase (SOD), malondialdehyde (MDA), catalase (CAT)] were detected; the pathological morphological changes of uterine tissue in rats were observed; the protein expressions of NOD-like receptor protein 3 (NLRP3), cleaved-caspase-1 and IKK/IκB/NF-κB signaling pathway were detected. RESULTS Compared with control group, a large number of inflammatory cells infiltrated into the smooth muscle layer of uterus in model group with irregular cell distribution; the uterine muscle strip muscle tone, serum levels of IL-1β, IL-6, TNF-α and MDA, protein expressions of NLRP3, cleaved-caspase-1, IKK, IκB and NF-κB p65 in uterine tissue were significantly increased in model group, and the serum levels of SOD and CAT were significantly decreased (P<0.05). Compared with the model group, the infiltration of inflammatory cells in the uterine smooth muscle layer was reduced in the emodin group, and all quantitative indexes were significantly improved (P<0.05); the infiltration of inflammatory cells in the uterine smooth muscle layer was increased in IKK activation group, and all quantitative indexes further deteriorated (P<0.05). Activation of IKK could significantly reduce the improvement effect of emodin on the above indexes in infectious preterm rats (P<0.05). CONCLUSIONS Emodin can relieve inflammation and oxidative stress in infectious preterm rats by inhibiting the IKK/IκB/NF-κB signaling pathway, thus improving uterine smooth muscle contraction.
9.Multivariate analysis of psychological health among hospital infection prevention and control practitioners in Tianjin
He LIU ; Chunnan FEI ; Xiaojuan ZHANG ; Jun LIU ; Jia SONG ; Zheng YAN
Chinese Journal of Industrial Hygiene and Occupational Diseases 2024;42(8):594-597
Objective:To understand the occupational stress and mental health status of hospital infection prevention and control practitioner (HIPCPs) in medical institutions, and analyze their main influencing factors.Methods:In November 2021, 550 nosocomial infection managers in Tianjin were randomly selected to conduct a questionnaire survey using the Concise Occupational Stress Questionnaire, Depression Screening Scale (PHQ-9) and Self-Rating Anxiety Scale (SAS). 497 valid questionnaires were obtained, and the total recovery efficiency was 90.36%. Single factor analysis and multivariate logistic regression method were used to analyze the main influencing factors of occupational stress and mental health status of psychiatric managers.Results:The detection rate of anxiety and depression among 497 HIPCPs was 22.73% (113/497) and 58.95% (293/497), respectively. Gender and major were the influencing factors of depression ( P=0.000, 0.001). Average working hours>52 hours per week and night shift days>1 days per week were the influencing factors of anxiety ( P=0.035, 0.014). Average working hours>52 h per week, night shift days >1 d per week and different majors were the influencing factors of occupational stress ( P=0.000, 0.025, 0.010). Multivariate logistic regression results showed that the risk of anxiety in those who worked more than 52 hours per week was 1.753 times that of those who worked less than 52 hours per week ( P=0.038), and the risk of depression in women was 3.071 times that of men ( P=0.006) . Conclusion:Working hours are an important influencing factor for occupational stress and anxiety among HIPCPs. In order to reduce the occurrence of occupational stress and mental health problems, it is necessary to strengthen psychological counseling for HIPCPs and balance work and rest.
10.Individualized Pharmaceutical Care for Digoxin Poisoning in Patient with Dilated Cardiomyopathy
Xiaojuan YANG ; Lan WANG ; Shubin CUI ; Zhaoshuai JI ; Qiantai MAO ; Weiwei SONG ; Chao AI
Herald of Medicine 2024;43(8):1321-1325
Objective To introduces drug treatment and individualized pharmaceutical care for a patient with dilated cardiomyopathy digoxin poisoning and provides ideas for pharmaceutical care.Methods The pharmacist used therapeutic drug management to analyze the course of drug treatment before and after hospitalization,combined with therapeutic drug monitoring and drug-gene detection,to analyze the causes of poisoning in digoxin from the perspectives of underlying diseases,polymor-phism,drug dosage,combination of drugs,physiological and other pathological factors,and to assist in clinical drug reformula-tion and optimization of drug treatment regimens.Results The clinician accepted the clinical pharmacist's suggestion.The pa-tient had a good prognosis,and digoxin poisoning did not occur in the later period.Conclusion This case provides a feasible treatment for dilated cardiomyopathy and other patients with digoxin intoxication;it can be used as a reference for the prevention and treatment of digoxin poisoning and provide a new direction for the development of hospital pharmaceutical care and pharma-ceutical professionals.

Result Analysis
Print
Save
E-mail