1.Experience of Using Charcoal-Processed Traditional Chinese Medicine in the Treatment of Gynecological Hemorrhagic Disorders
Xiaolan WU ; Zhaoling YOU ; Guiyun WANG ; Kailing WANG ; Xiaojuan YE ; Lingyu LIAO ; Yueheng LI ; Huiping LIU
Journal of Traditional Chinese Medicine 2025;66(3):308-311
Charcoal-processed traditional Chinese herbal medicine has various therapeutic effects, including astringing, hemostasis, anti-diarrhea, clearing heat, tonifying, and warming the interior. This paper summarizes the clinical application features, compatible experiences, dosages, and precautions for over 20 types of charcoal-processed herbal medicine in the treatment of gynecological bleeding disorders caused by dysfunctions such as dysfunctional uterine bleeding, endometriosis, uterine incision pseudocavity, and vaginal bleeding resulting from threatened miscarriage. The charcoal-processed herbal medicine include Huangqin (Scutellaria Baicalensis) Charcoal, Dahuang (Rheum Palmatum) Charcoal, Cebai (Platycladus Orientalis) Charcoal, Diyu (Sanguisorba Officinalis) Charcoal, Daji (Cirsium Setosum) Charcoal, Xiaoji (Cirsium Japonicum) Charcoal, Shengdi (Rehmannia Glutinosa) Charcoal, Aiye (Artemisia Argyi) Charcoal, Paojiang (Zingiber Officinale) Charcoal, Xuduan (Dipsacus Asper) Charcoal, Duzhong (Eucommia Ulmoides) Charcoal, Qiancao (Rubia Cordifolia) Charcoal, Puhuang (Typha Angustifolia) Charcoal, Shanzha (Crataegus Pinnatifida) Charcoal, Jingjie (Schizonepeta Tenuifolia) Charcoal, Xueyu (Carthamus Tinctorius) Charcoal, Zonglyu (Areca Catechu) Charcoal, Wumei (Prunus Mume) Charcoal, Shudahuang (Rheum Officinale) Charcoal, Lianfang (Nymphaea Alba) Charcoal, Mianmaguanzhong (Clematis Armandii) Charcoal, and Oujie (Nelumbo Nucifera) Charcoal.
2.Introduction on the revised content on abnormal toxicity test in the Chinese Pharmacopoeia 2025 Edition(Volume Ⅲ)
WANG Xiaojuan ; WANG Liping ; LIU Ying ; LI Huiyi
Drug Standards of China 2025;26(1):105-109
Based on the implementation of GMP, comprehensive improvement of quality control measures, and consideration of the 3Rs principle for experimental animals, Several years ago, WHO, the European Pharmacopoeia and the FDA gradually abolished the testing for abnormal toxicity of biological products, and the Chinese Pharmacopoeia 2025 Edition(Volume Ⅲ)also revised the testing for abnormal toxicity of biological products. In order to help users of the Chinese Pharmacopoeia(Volume Ⅲ) better understand and implement this pharmacopoeia, this article provides a detailed review of the changes in regulatory concepts for abnormal toxicity test in various countries and the process of gradually phasing out abnormal toxicity test, as well as the actual situation of China’s pharmaceutical industry. It also interprets the ideas and considerations for revising the Chinese Pharmacopoeia 2025 Edition(Volume Ⅲ) on abnormal toxicity test for biological products.
3.Clinical Characteristics and Early Risk Factors for Toxic Encephalopathy in Acute Diquat Poisoning
Yihong YANG ; Jiawei LI ; Xiaojuan LIU ; Qiqi LIU ; Hongbo LIU ; Guanghua XIONG ; Yecheng LIU
Medical Journal of Peking Union Medical College Hospital 2025;16(5):1229-1235
To analyze the clinical characteristics of acute diquat poisoning complicated by central nervous system injury (CNSI) and identify early risk factors, aiming to provide a theoretical basis for reducing mortality in diquat poisoning with CNSI. Clinical data from patients with acute diquat poisoning admitted to the Emergency Department of Fuyang People's Hospital Affiliated to Anhui Medical University between October 2019 and October 2024 were retrospectively analyzed. Patients were divided into CNSI and non-CNSI groups based on complications. Clinical features were compared between groups, and variables with statistical significance were subjected to binary logistic regression to identify independent risk factors for CNSI. Receiver operating characteristic (ROC) curves were generated to evaluate the predictive value of these factors. A total of 63 eligible patients were included, with 18 deaths (28.57%) and 26 cases (41.27%) complicated by CNSI. The median time from diquat ingestion to CNSI onset was 15.5 (9.8, 31.3) hours. The CNSI group exhibited significantly higher mortality rates and required more frequent respiratory support and anti-shock therapy than the non-CNSI group (all CNSI is a fatal complication of acute diquat poisoning with high mortality. Diquat plasma concentration (≥549.95 μg/L) and APACHE Ⅱ score are independent risk factors for CNSI, and their combined application enhances predictive accuracy. These findings underscore the importance of early risk stratification and targeted interventions in high-risk populations.
4.The value of HPV DNA and HPV E6/E7 mRNA detection in screening for cervical lesions
Hantao SONG ; Xiaojuan LIU ; Fang LIU ; Li CHANG ; Jie TENG
International Journal of Laboratory Medicine 2024;45(4):467-470
Objective To investigate the value of human papillomavirus(HPV)DNA and HPV E6/E7 mRNA detection in screening for cervical lesions.Methods A total of 619 patients who were screened for cer-vical lesions in West China Second University Hospital from September 2021 to August 2022 were selected as the study objects.The value of HPV DNA and HPV E6/E7 mRNA detection in cervical lesion screening was evaluated based on their pathological results.Results The positive rate of HPV DNA detection was 64.78%(401/619)and that of HPV E6/E7 mRNA detection was 60.74%(376/619)in 619 patients.Cervical lesion screening was mainly conducted in sexually active people aged 30-<40 years and 40-<50 years.The posi-tive rates of HPV DNA and HPV E6/E7 mRNA increased with the increase of cervical lesion grade.The sen-sitivity,positive predictive value and negative predictive value of the two methods were higher than those of HPV DNA or HPV E6/E7 mRNA detection.Conclusion The combined detection of the two methods can be used for screening cervical lesions at various pathological stages,which can provide greater guidance value in clinical diagnosis and treatment.
5.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
6.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
7.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
8.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
9.Angiopathic Mechanisms on Diabetic Delayed Healing Wounds:Impact and Advances in Therapeutic Agents
Yunxiang WANG ; Bin LI ; Xiaojuan MOU ; Jianjun LIU ; Qipeng HAN ; Taowen PAN ; Jing LIU ; Yunpeng DIAO
Herald of Medicine 2024;43(4):577-581
The prevalence of diabetes mellitus in China has recently been increasing year by year,and spontaneous skin ulcers in diabetic patients,as one of the most serious complications,often develop on the patient's extremities represented by foot ulcers.Due to the complexity and variety of its pathogenesis,it leads to poor clinical outcomes and difficulty in healing.Thus,pa-tients often face the risk of amputation and death.Therefore,the exploration of mechanisms of the vascular pathogenesis of diabetic delayed-healing wounds and targeted screening of therapeutic agents has become a current research hotspot.Herein,in this paper,we briefly review the role of impaired angiogenesis and vascular dysfunction in diabetic skin ulcers,and the research progress of classical hypoglycemic and natural compounds against vascular lesions is preliminarily summarized to provide a theoretical basis for effective clinical treatment.
10.Mdivi-1 protects oligodendrocytes through inhibiting apoptotic signaling pathway
Yanhua LI ; Xiaojuan ZHANG ; Siyu ZHANG ; Xiyuan HOU ; Ziyi LIU ; Xiao-Jing YU ; Nianping ZHANG
Chinese Journal of Pathophysiology 2024;40(3):527-534
AIM:To investigate the therapeutic effect of mitochondrial fission inhibitor-1(Mdivi-1)on experi-mental autoimmune encephalomyelitis(EAE)in mice,and to explore its mechanism.METHODS:The mice immunized with myelin oligodendrocyte glycoprotein peptide fragment 35-55(MOG35-55)were randomly divided into DMSO model group and Mdivi-1 intervention group.All mice were sacrificed on the 28th day after the first immunization.The demyelination was analyzed by Luxol fast blue staining.The protective mechanism of Mdivi-1 in the spinal cord tissue was investigated by immunofluorescence staining,TUNEL staining and the in vitro experiment with MO3.13 oligodendrocytes treated with staurosporine.The mitochondrial depolarization was detected by JC-1 staining,the cell injury was checked by LDH leakage,and the viability of MO3.13 oligodendrocytes was determined by MTT assay.RESULTS:Compared with DMSO model group,the demyelinating injury was alleviated and the proportion of apoptotic CC1+ oligodendrocytes in Mdivi-1 group was decreased.The cleaved caspase-3,caspase-9,cytochrome C and Bax protein expression levels in the spinal cord of Mdivi-1-treated mice was also attenuated.The in vitro MO3.13 cell experiments suggested that Mdivi-1 inhibited MO3.13 cell mitochondrial depolarization,attenuated the cell damage and increased the cell viability.CONCLUSION:Mdivi-1 pro-tects against the myelin injury in EAE mice,which may be related to the suppression of oligodendrocyte apoptosis.

Result Analysis
Print
Save
E-mail