1.Effect of electroacupuncture combined with low-frequency transcranial ultrasound stimulation on the electroencephalographic signals of rats with traumatic brain injury
Simiao GAO ; Xue HAN ; Xiaoguang WU ; Jinyu ZHENG ; Fangwen GAO ; Kuihua LI ; Yong PENG ; Lanxiang LIU
Chinese Journal of Tissue Engineering Research 2025;29(2):402-408
BACKGROUND:Traumatic brain injury is a condition in which the normal function of the brain is disrupted by a bump or impact to the head.It is necessary to find effective treatments and objective targets that can help doctors diagnose the injury status and restore the brain function of patients. OBJECTIVE:To explore the effect of electroacupuncture combined with low-frequency transcranial ultrasound stimulation on the electroencephalographic signals of rats with traumatic brain injury. METHODS:Forty 6-week-old SPF male Sprague-Dawley rats were randomly divided into five groups:sham group,model group,electroacupuncture group,low-frequency transcranial ultrasound stimulation group and combined group(electroacupuncture+low-frequency transcranial ultrasound stimulation),with eight rats in each group.Feeney weight-drop method was used to establish the animal model of traumatic brain injury.In the sham group,the bone window was only opened without impact.Interventions were started at 1 day after modeling.Electroacupuncture in the electroacupuncture group,low-frequency transcranial ultrasound stimulation in the low-frequency transcranial ultrasound stimulation group,and electroacupuncture+low-frequency transcranial ultrasound stimulation in the combined group were performed for days in total.The modified neurological severity scale score for assessing rats'neurological deficits was performed at 8 hours after modeling.The percentage of spontaneous alternation behavior in the Y-maze was measured at 7 days after modeling.Then,the electroencephalographic signals were collected and electroencephalographic data of α,β,θ,and δ waves were extracted by fast Fourier transform,and the value of oscillation amplitude and energy ratio were calculated in α,β,θ,and δ waves,as well as the Lempel-Ziv complexity and sample entropy. RESULTS AND CONCLUSION:Compared with the sham group,the modified neurological severity scale scores in the model group,electroacupuncture group,low-frequency transcranial ultrasound stimulation group and combined group were significantly increased at 8 hours after modeling(P<0.05).Compared with the sham group,the value of oscillation amplitude in δ wave and the value of δ energy ratio were significantly increased in the model group at 7 days after modeling,meanwhile the percentage of spontaneous alternation behavior in Y-maze,and the value of α/β energy ratio,Lempel-Ziv complexity,and sample entropy were significantly decreased(P<0.05).Compared with the model group,the value of oscillation amplitude in α and δ waves was significantly decreased in the combined group(P<0.05),while the value of α/β energy ratio was significantly increased(P<0.05)and the value of δ energy ratio was significantly decreased(P<0.05)in the electroacupuncture group,low-frequency transcranial ultrasound stimulation group and combined group.Compared with the electroacupuncture group and low-frequency transcranial ultrasound stimulation group,the value of δ energy ratio was significantly decreased in the combined group(P<0.05),while the percentage of spontaneous alternation behavior,the value of α/β energy ratio,the Lempel-Ziv complexity,and the sample entropy were significantly increased(P<0.05).To conclude,abnormal electroencephalographic signals can appear in rats with traumatic brain injury,while the electroacupuncture combined with low-frequency transcranial ultrasound stimulation can alleviate the abnormal electroencephalographic signals in rats,which suggests the electroencephalographic frequency domain value and nonlinear features can be used to assess the severity of traumatic brain injury.
2.Thermal proteome profiling (TPP) reveals NAMPT as the anti-glioma target of phenanthroindolizidine alkaloid PF403.
Fangfei LI ; Zhaoxin ZHANG ; Qinyan SHI ; Rubing WANG ; Ming JI ; Xiaoguang CHEN ; Yong LI ; Yunbao LIU ; Shishan YU
Acta Pharmaceutica Sinica B 2025;15(4):2008-2023
Glioma is difficult to treat due to the unique tumor microenvironment and blood-brain barrier. (13aS)-3-Hydroxyl-6,7-dimethoxyphenanthro[9,10-b] indolizidine (PF403), a phenanthroindolizidine alkaloid, has been identified as a promising therapeutic agent for the treatment of glioma. However, the anti-glioma mechanism of PF403 in vivo has not been conclusively verified and must be further elucidated. Hence, a strategy without chemical modification was applied to identify the target of PF403. In this study, we identified nicotinamide phosphoribosyl transferase (NAMPT) as the target of PF403 by using thermal proteome profiling (TPP). Moreover, microscale thermophoresis (MST), surface plasmon resonance (SPR), and isothermal titration calorimetry (ITC) experiments confirmed that NAMPT exhibits good affinity for PF403. Direct and indirect enzyme activity assays revealed that PF403 inhibited the catalytic activity of NAMPT, leading to a decrease in the concentration of nicotinamide adenine dinucleotide (NAD+) in U87 cells. X-ray diffraction and amino acid spot mutation experiments revealed that PF403 primarily relies on the formation of pi-pi interactions with residue Tyr188 to maintain binding with NAMPT (PDB code 8Y55). After NAMPT was knocked down with lentivirus, PF403 lost or partially lost its antitumor activity at the cellular and animal levels. These findings suggest that PF403 exerts antitumor activity by directly targeting NAMPT.
3.Development of an Integrated Disposable Device for SARS-CoV-2 Nucleic Acid Extraction and Detection
Ma JING ; Hao YANZHE ; Hou MEILING ; Zhang XIAOSHAN ; Liu JINGDUAN ; Meng HAODI ; Chang JIANGBO ; Ma XUEJUN ; Liu JIHUA ; Ying QINGJIE ; Wang XIANHUA ; Li HONGXIA ; Cao YUXI ; Zhang XIAOGUANG
Biomedical and Environmental Sciences 2024;37(6):639-646
Objective To develop a highly sensitive and rapid nucleic acid detection method for the severe acute respiratory syndrome coronavirus 2(SARS-CoV-2). Methods We designed,developed,and manufactured an integrated disposable device for SARS-CoV-2 nucleic acid extraction and detection.The precision of the liquid transfer and temperature control was tested.A comparison between our device and a commercial kit for SARS-Cov-2 nucleic acid extraction was performed using real-time fluorescence reverse transcription polymerase chain reaction(RT-PCR).The entire process,from SARS-CoV-2 nucleic acid extraction to amplification,was evaluated. Results The precision of the syringe transfer volume was 19.2±1.9 μL(set value was 20),32.2±1.6(set value was 30),and 57.2±3.5(set value was 60).Temperature control in the amplification tube was measured at 60.0±0.0 ℃(set value was 60)and 95.1±0.2 ℃(set value was 95)respectively.SARS-Cov-2 nucleic acid extraction yield through the device was 7.10×106 copies/mL,while a commercial kit yielded 2.98×106 copies/mL.The mean time to complete the entire assay,from SARS-CoV-2 nucleic acid extraction to amplification detection,was 36 min and 45 s.The detection limit for SARS-CoV-2 nucleic acid was 250 copies/mL. Conclusion The integrated disposable devices may be used for SARS-CoV-2 Point-of-Care test(POCT).
4.Efficacy and Safety of Combined Bedaquiline and Delamanid Use among Patients with Multidrug-Resistant Tuberculosis in Beijing,China
Guo CAN ; Nie LIHUI ; Song YANHUA ; Liu RONGMEI ; Wu XIAOGUANG ; Shang YUANYUAN ; Zhang XUXIA ; Pang YU ; Gao MENGQIU
Biomedical and Environmental Sciences 2024;37(10):1195-1203
Objectives The combined use of bedaquiline and delamanid(BDQ-DLM)is limited by an increased risk of prolonging the QTc interval.We retrospectively evaluated patients who received DLM/BDQ-containing regimens at a TB-specialized hospital.We aimed to present clinical efficacy and safety data for Chinese patients. Methods This case-control study included patients with multidrug-resistant tuberculosis(MDR-TB)treated with BDQ alone or BDQ plus DLM. Results A total of 96 patients were included in this analysis:64 in the BDQ group and 32 in the BDQ+DLM group.Among the 96 patients with positive sputum culture at the initiation of BDQ alone or BDQ combined with DLM,46 patients(71.9%)in the BDQ group and 29(90.6%)in the BDQ-DLM group achieved sputum culture conversion during treatment.The rate of sputum culture conversion did not differ between the two groups.The time to sputum culture conversion was significantly shorter in the BDQ-DLM group than in the BDQ group.The most frequent adverse event was QTc interval prolongation;however,the frequency of adverse events did not differ between the groups. Conclusion In conclusion,our results demonstrate that the combined use of BDQ and DLM is efficacious and tolerable in Chinese patients infected with MDR-TB.Patients in the BDQ-DLM group achieved sputum culture conversion sooner than those in the BDQ group.
5.Establishment of rapid influenza virus detection technology based on an integrated system
Xiaoshan ZHANG ; Jing MA ; Yanzhe HAO ; Jing YANG ; Meiling HOU ; Hongxia LI ; Jingduan LIU ; Haodi MENG ; Yuxi CAO ; Xiaoguang ZHANG
Chinese Journal of Experimental and Clinical Virology 2024;38(3):319-325
Objective:This study aimed to develop a rapid and accurate integrated nucleic acid detection method tailored for the influenza virus.Methods:We designed primers and probes targeting the predominant influenza virus strains circulating in China in recent years. These were integrated with extraction and amplification reagents and a point of care testing (POCT) system to facilitate a seamless and expedited process involving nucleic acid extraction, reaction system preparation, amplification, and result interpretation for the influenza virus. The specificity of the POCT system was evaluated using cultured influenza viruses, while its cross-reactivity was assessed against common respiratory pathogens, including adenovirus and respiratory syncytial virus.Results:Our study successfully developed duplex amplification primers and probes for both influenza A and B viruses, achieving a detection threshold as low as 500 copies/ml. Specificity tests confirmed that the detection reagents did not show cross-reactivity with other respiratory pathogens such as adenovirus and respiratory syncytial virus. The POCT-based rapid nucleic acid detection method for influenza virus was established, it is capable of completing the entire process from nucleic acid extraction to amplification and result interpretation within 50 minutes, while enabling real-time data upload.Conclusions:The POCT-based rapid influenza virus detection kit developed in this study offers a " sample in, results out" convenience, making it suitable for rapid influenza virus detection in primary care settings. This innovation has significant potential for clinical application.
6.Informatics Consideration on the Hierarchical System of Rare Diseases Clinical Care in China
Mengchun GONG ; Yanying GUO ; Xihong ZHENG ; Junkang FAN ; Peng LIU ; Ling NIU ; Yining YANG ; Xiaoguang ZOU
JOURNAL OF RARE DISEASES 2024;3(4):527-534
The diagnosis and treatment resources for rare diseases in China are highly imbalanced. The basic diagnosis and treatment capabilities are weak, the diagnosis period for patients is long, and the rates of missed diagnosis and misdiagnosis are relatively high. The establishment of a hierarchical diagnosis and treatment system is the inevitable approach to enhancing the diagnosis and treatment standards of rare diseases. Currently, the implementation of the domestic hierarchical diagnosis and treatment system for rare diseases still confronts numerous challenges, such as ambiguous referral standards and processes of primary medical institutions, and ineffective information interaction among institutions at all levels. Thus, it is essential to facilitate high-level information construction for the hierarchical diagnosis and treatment of rare diseases. This paper explores the process of constructing a multidisciplinary joint remote diagnosis and treatment platform and a health management platform through informatization, with the hope of establishing two closed loops of digital diagnosis and treatment services and health follow-up management for patients with rare diseases, as well as achieving timely diagnosis and lifelong health management for patients. It integrates and optimizes auxiliary diagnostic tools, promotes the rapid dissemination of rare disease diagnosis and treatment experiences to the grassroots, enhances the information construction level of the hierarchical diagnosis and treatment system, and endeavors to address the practical predicament of weak diagnosis and treatment capabilities of rare diseases in grassroots medical institutions. Additionally, this paper proposes an essential approach for multi-dimensional independent innovation to guide the popularization of efficient and high-quality rare disease diagnosis and treatment services. By encompassing innovating the rare disease diagnosis and treatment collaboration network and multidisciplinary diagnosis and treatment model, facilitating the application of the latest biomedical and informatics technologies to the grassroots, and constructing a national intelligent data platform for rare disease innovation, a new model for rare disease services with Chinese characteristics will be established. This will significantly enhance the medical treatment level of rare diseases in China and strive for more benefits for patients.
7.Analysis of beam characteristics of the first Mevion pencil beam scanning proton therapy system in China
Weiqing WU ; Xiaoguang LU ; Renchao ZHENG ; Zhiyi PENG ; Fei LIU ; Guangyuan HU ; Xianglin YUAN
Chinese Journal of Medical Physics 2024;41(3):282-288
Objective To present and discuss beam characteristics of the first Mevion S250i gantry-mounted accelerator pencil beam scanning proton therapy system in China.Methods The output dose was measured using a parallel-plate ionization chamber.The integrated depth dose was measured with a large-radius Bragg peak ionization chamber,covering 19 energy levels ranging from 227 MeV to 28 MeV,to analyze the proton beam characteristics.The spots in the air were measured with Phoenix flat panel detector on the beam central axis,and the precision of the delivery position was verified by measuring the multi-spot beam map.The interleaf leakage and penumbra reduction of adaptive aperture were measured to characterize its performance.Results The proton system was calibrated for a maximum energy of 227 MeV,with a(10×10)cm2uniform field delivering 1 Gy dose at a depth of 5 cm underwater.The system effectively modulated the proton beam range to the patient's surface,maintaining a constant 80%-80%Bragg peak width of 8.6 mm at all energy levels.The spot size of the highest energy beam at the isocenter was about 4 mm in the air,and the spot delivery position error was less than 1 mm.The interleaf leakage rate of the adaptive aperture for the highest energy beam was below 1.5%,and the penumbra was significantly reduced.Conclusion Mevion S250i proton therapy system demonstrates unique design and beam characteristics,which is reflected in the Bragg peak shape,spot size variation with energy,and penumbra sharpening of adaptive aperture;and these differences should be considered in treatment planning system modeling and planning for precision treatment.
8.Clinical guidelines for the treatment of ankylosing spondylitis combined with lower cervical fracture in adults (version 2024)
Qingde WANG ; Yuan HE ; Bohua CHEN ; Tongwei CHU ; Jinpeng DU ; Jian DONG ; Haoyu FENG ; Shunwu FAN ; Shiqing FENG ; Yanzheng GAO ; Zhong GUAN ; Hua GUO ; Yong HAI ; Lijun HE ; Dianming JIANG ; Jianyuan JIANG ; Bin LIN ; Bin LIU ; Baoge LIU ; Chunde LI ; Fang LI ; Feng LI ; Guohua LYU ; Li LI ; Qi LIAO ; Weishi LI ; Xiaoguang LIU ; Hongjian LIU ; Yong LIU ; Zhongjun LIU ; Shibao LU ; Yong QIU ; Limin RONG ; Yong SHEN ; Huiyong SHEN ; Jun SHU ; Yueming SONG ; Tiansheng SUN ; Yan WANG ; Zhe WANG ; Zheng WANG ; Hong XIA ; Guoyong YIN ; Jinglong YAN ; Wen YUAN ; Zhaoming YE ; Jie ZHAO ; Jianguo ZHANG ; Yue ZHU ; Yingjie ZHOU ; Zhongmin ZHANG ; Wei MEI ; Dingjun HAO ; Baorong HE
Chinese Journal of Trauma 2024;40(2):97-106
Ankylosing spondylitis (AS) combined with lower cervical fracture is often categorized into unstable fracture, with a high incidence of neurological injury and a high rate of disability and morbidity. As factors such as shoulder occlusion may affect the accuracy of X-ray imaging diagnosis, it is often easily misdiagnosed at the primary diagnosis. Non-operative treatment has complications such as bone nonunion and the possibility of secondary neurological damage, while the timing, access and choice of surgical treatment are still controversial. Currently, there are no clinical practice guidelines for the treatment of AS combined with lower cervical fracture with or without dislocation. To this end, the Spinal Trauma Group of Orthopedics Branch of Chinese Medical Doctor Association organized experts to formulate Clinical guidelines for the treatment of ankylosing spondylitis combined with lower cervical fracture in adults ( version 2024) in accordance with the principles of evidence-based medicine, scientificity and practicality, in which 11 recommendations were put forward in terms of the diagnosis, imaging evaluation, typing and treatment, etc, to provide guidance for the diagnosis and treatment of AS combined with lower cervical fracture.
9.Application of adaptive aperture in proton radiotherapy for brain tumors
Weiqing WU ; Xianglin YUAN ; Guangyuan HU ; Renchao ZHENG ; Qianxia LI ; Fei LIU ; Xiaoguang LU
Chinese Journal of Radiological Medicine and Protection 2024;44(1):24-28
Objective:To evaluate the clinical application value of the adaptive aperture by comparing intensity-modulated proton radiotherapy(IMPT) plans using and not using the aperture for brain tumors.Methods:A total of twenty patients treated with postoperative radiotherapy for brain tumors were enrolled in this study. IMPT plans were developed for each patient using and not using the adaptive aperture under the same optimization conditions. The target conformal index (CI) value, target homogeneity index (HI) value, and the dose to normal tissues of the two sets of plans were compared.Results:The IMPT plans designed using the adaptive aperture significantly increased the mean CI value from 0.58 to 0.66, while decreasing the mean 50% prescription dose volume from 797.70 cm 3 to 638.15 cm 3. These plans also reduced the irradiation doses to the cochlea, brainstem, optic chiasm, optic nerve, and lens ( t = 2.06, 3.02, 2.11, 2.58, 2.67, P < 0.05). Additionally, there was no significant difference in the HI value of the target volumes and the machine jumps (MU) between the two sets of plans ( P > 0.05). Conclusions:The adaptive aperture can significantly reduce the irradiation dose to normal tissues outside the target volumes, positively impacting the protection of organs at risk (OARs) around the target values. This demonstrates its great potential for clinical application.
10.Prediction of osteoporotic vertebral compression fracture based on comprehensive index of lumbar vertebral bone strength
Wensheng ZHANG ; Zhenjie SONG ; Chunfei WU ; Wenchao LI ; Hongjiang LIU ; Xiaoguang YANG ; Chao YUAN
Chinese Journal of Tissue Engineering Research 2024;28(18):2871-2875
BACKGROUND:Osteoporotic vertebral compression fracture is a common fracture secondary to osteoporosis.At present,there is no effective prediction index and method for osteoporotic vertebral compression fracture. OBJECTIVE:To investigate the predictive effect of the comprehensive index of lumbar vertebral body bone strength on osteoporotic vertebral compression fracture. METHODS:233 patients with osteoporosis were divided into a fracture group and a non-fracture group according to whether a vertebral fracture occurred.The demography,body mass index,vertebral bone mineral density and other details were collected.Lateral X-ray films of the lumbar spine were photographed.The vertebral body width,vertebral body length,sacral slope,pelvic tilt,pelvic incidence,lumbar compressive strength index and the lumbar impact strength index were measured,calculated,and analyzed by univariate and multivariate,and the receiver operating characteristic curve was analyzed.The survival analysis was conducted according to the cut-off value. RESULTS AND CONCLUSION:(1)All patients were followed up for 2-4 years,with an average of 3.1 years.During the follow-up period,99 cases(38 cases of L1 vertebral body,61 cases of L2 vertebral body)had fractures(fracture group),and 134 cases(52 cases of L1 vertebral body,82 cases of L2 vertebral body)had no fractures(non-fracture group).Univariate analysis showed that there was no significant difference in age,sex,height,body mass,body mass index and fracture segment between the two groups(P>0.05).(2)Lumbar compressive strength index and lumbar impact strength index in the fracture group were lower than those in the non-fracture group(P<0.05).Pelvic incidence and pelvic tilt in the fracture group were higher than those in the non-fracture group(P<0.05).(3)Multivariate analysis showed that lumbar compressive strength index,lumbar impact strength index and pelvic tilt were risk factors for osteoporotic vertebral compression fractures(P<0.05).(4)Receiver operating characteristic curve analysis showed that the cutoff values of vertebral bone mineral density,lumbar compressive strength index,lumbar impact strength index,pelvic tilt and pelvic incidence were 0.913 5 g/cm2,1.932,0.903,21.5° and 55°,respectively;areas under the curve were 0.630,0.800,0.911,0.633 and 0.568,respectively.(5)According to the survival analysis(with osteoporotic vertebral compression fracture as the end point),the average survival time of the patients with lumbar impact strength index≥0.903 was significantly longer than that of the patients with lumbar impact strength index<0.903(P<0.05).(6)These findings conclude that the comprehensive index of lumbar vertebral body bone strength is more accurate than the bone mineral density of the vertebral body and spine-pelvis sagittal parameters in predicting osteoporotic vertebral compression fractures,which is helpful for early prevention and treatment of osteoporotic vertebral compression fractures.

Result Analysis
Print
Save
E-mail