1.Survey on the awareness and clinical application of guidelines for the prevention and treatment of chronic hepatitis B (2022 edition) among clinicians
Yuanyuan KONG ; Yujie GUO ; Yujuan GUAN ; Xuan LIANG ; Zhongjie HU ; Xiaobo LU ; Mingqin LU ; Yongfeng YANG ; Meifang HAN ; Hong YOU ; Zhiyun YANG ; Jidong JIA
Journal of Clinical Hepatology 2025;41(6):1068-1074
ObjectiveTo investigate the awareness and clinical practice of guidelines for the prevention and treatment of chronic hepatitis B (2022 edition) among clinicians. MethodsFrom July 19 to December 31, 2024, a self-designed electronic questionnaire was distributed via the WeChat mini program to collect related data from 1 588 clinicians nationwide, including their awareness and practice based on 18 questions regarding testing and referral, diagnosis and treatment, and follow-up. ResultsAmong all respondents, only 350 clinicians correctly understood all the updated key points of antiviral indications and treatment for special populations in the 2022 edition of guidelines for the prevention and treatment of chronic hepatitis B, with an overall awareness rate of 22.0%. Only 20% — 40% of the patients with positive HBV DNA and an age of >30 years receive antiviral therapy, while 80% — 100% of the patients with positive HBV DNA and a family history of hepatitis B cirrhosis or hepatocellular carcinoma receive antiviral therapy. The median follow-up rates at 1 year, 3 years, and 5 years were 67.5% 57.5% and 47.5%,respectively, showing a trend of gradual reduction, which might be associated with the influencing factors such as insufficient time for follow-up management by clinicians, insufficient awareness of the disease among patients, and poor adherence to follow-up. ConclusionThere is a gap between the awareness and practice of guidelines for the prevention and treatment of chronic hepatitis B (2022 edition) among clinicians. It is recommended to further strengthen training and focus on the whole process of “detection, diagnosis, treatment, and management” for patients with chronic hepatitis B in healthcare institutions, in order to promote the implementation of the guidelines.
2.Finite element simulation and experimental test of normal coracoclavicular ligament and flexible reconstruction
Guizhu JI ; Qiu ZHENG ; Wuxiang WANG ; Guan WANG ; Wen LI ; Xiaobo LU ; Ke DUAN ; Zhong LI ; Hongbin YANG ; Cheng LIANG
Chinese Journal of Tissue Engineering Research 2024;28(5):706-711
BACKGROUND:For dislocation of acromioclavicular joint induced by coracoclavicular ligament fracture,single EndoButton Plate reconstruction and double EndoButton Plates reconstruction are common repair methods.Further study on the stress distribution and fracture risk of the two repair methods is of great significance. OBJECTIVE:To study the biomechanical properties of the coracoclavicular ligament,and compare the fixation effect,stress distribution and failure mode of single and double EndoButton Plates reconstruction. METHODS:(1)Finite element simulation analysis:Mimics,Wrap and SolidWorks were used to establish normal coracoclavicular ligament,single EndoButton Plate reconstruction and double EndoButton Plates reconstruction.Ansys software was used to analyze the stress and deformation of the scapula and clavicle of each model under vertical load.(2)Sample experiment:Fifteen intact scapular-clavicle specimens were randomly grouped into five groups,with three specimens in each group.In group A,the acromioclavicular ligament was severed and the coracoclavicular ligament remained intact.In group B,acromioclavicular ligaments and trapeoid ligaments were severed,leaving intact conical ligaments.In group C,acromioclavicular ligaments and conical ligaments were cut off,and the intact traprex ligaments were retained.In group D,acromioclavicular and coracoclavicular ligaments were severed,and coracoclavicular ligaments were repaired by single EndoButton Plate reconstruction.In group E,acromioclavicular and coracoclavicular ligaments were severed,and the coracoclavicular ligaments were repaired by double EndoButton Plates reconstruction.The mechanical experiment was carried out by a mechanical testing machine to analyze the biomechanical status,stress distribution and failure patterns of the scapular-clavicle and clavicle. RESULTS AND CONCLUSION:(1)Finite element simulation analysis:The average stress of coracoclavicular ligament attached specimens was the lowest,and the risk of coracoclavicular fracture was less than that of single and double EndoButton Plates reconstruction.The mean stress of the coracoid process was similar in single and double EndoButton Plates reconstruction,and the fracture risk was similar.(2)Sample experiment:In groups A,B,C,D and E,the stiffness of specimens was(26.4±3.5),(19.8±2.8),(21.3±3.2),(57.7±4.1),and(46.2±2.8)N/mm,respectively;the ultimate loads were(545.5±53.7),(360.1±42.1),(250.9±44.4),(643.5±39.1),and(511.9±31.7)N,respectively;global stiffness in groups D and E was higher than that in group A(P=0.000 06,0.000 3);ultimate load in group D was higher than that in group A(P<0.05);the ultimate load was not significantly different between the group E and group A(P>0.05).Ligament fracture was observed in groups A,B and C and coracoid process fracture was found in groups D and E.(3)These results suggest that from the biomechanical analysis,Single EndoButton Plate reconstruction and double EndoButton Plates reconstruction are effective treatment techniques for coracoclavicular ligament fracture in acromioclavicular joint dislocation,but increase the risk of fracture.The double EndoButton Plates reconstruction dispersed the stress of the steel plate and reduced the contact force between the steel plate and bone,but slightly reduced the ultimate bearing capacity.Single and double EndoButton Plates reconstruction should be selected according to the actual clinical situation.
3.Finite element and biomechanical analysis of different implants in repair for unilateral unstable pelvic posterior ring injury
Cheng LIANG ; Linqi ZHANG ; Guan WANG ; Wen LI ; Ke DUAN ; Zhong LI ; Xiaobo LU ; Naiqiang ZHUO
Chinese Journal of Tissue Engineering Research 2024;28(9):1336-1341
BACKGROUND:The stability of the pelvis is mainly determined by the posterior pelvic ring and the sacroiliac joint.The posterior pelvic ring injury and the dislocation of the sacroiliac joint caused by high energy impacts such as car accidents increase year by year.Surgical treatment is the best method,and there are many kinds of endophytorepair methods in clinical practice,but which treatment method has the best biomechanical properties is still controversial. OBJECTIVE:To compare the biomechanical properties of three kinds of internal implants:anterior double plates,posterior bridging plate and tension nail in the repair of unilateral unstable pelvic posterior ring injury,to provide a reference for the clinical treatment and development of a new pelvic tension screw. METHODS:(1)Finite element simulation:Mimics,Wrap and SolidWorks were used to establish normal pelvic model,unilateral injured pelvis model,and three kinds of internal implant repaired models(anterior double plates,posterior bridging plate and tension nail).Ansys was used to analyze the stress and deformation of the models.(2)Biomechanical test:A total of 15 intact pelvic specimens were randomly grouped into five groups,normal pelvic model,unilateral injured pelvis model,anterior double plates,posterior bridging plate and tension nail groups.The mechanical test was performed using an Instron E10000 testing machine. RESULTS AND CONCLUSION:(1)Simulation:In the normal pelvic model,the average displacement of the sacrum was 0.174 mm,and the maximum stress of the sacral iliac bone was 10.51 MPa,and the stress distribution was uniform.The mean sacral displacement of the unilateral injured pelvis model was 0.267 mm,and the stress concentration of the model was obvious.The mean displacement of the sacrum in the three repaired models was close to that in the normal pelvic model,and the stress distribution of the sacral iliac bone in the tension nail repaired model was uniform.(2)Mechanical test:The stiffness of the normal pelvic model was(226.38±4.18)N/mm,and that of the unilateral unstable pelvic model was the smallest(130.02±2.19)N/mm.The deviation of the normal pelvic model stiffness and the three repaired models'stiffness were all within(±10%),and the repair effect was obvious.(3)The simulation results were in agreement with the experimental results.(4)The biomechanics of the tension nail repaired model was the most similar to that of the normal pelvis,and this method was the best.The repairing stiffness of the anterior double plate was too large,and the stress shielding effect was more significant.The posterior bridging plate repair could not solve the compensatory effect of the normal side soft tissue and had defects.This study provides an optimal basis for clinical surgery.(5)The new type of pelvic tension nail should be improved from the point of view of the tension nail to retain the good biomechanical properties of the tension nail,while adding other advantages,such as being used for the osteoporotic pelvis.
4.Analysis of the diagnosis and treatment experience and etiological characteristics of 119 cases of primary canaliculitis
Qinghua WANG ; Zhengwei ZHANG ; Qiuhong WANG ; Shui LU ; Xiaobo GU ; Liang GUO ; Yunjia JIANG
International Eye Science 2024;24(1):144-148
AIM: To explore the clinical features, diagnosis and treatment experience and the distribution characteristics of pathogenic microorganisms of primary canaliculitis, and provide reference for its diagnosis and treatment. METHODS: Retrospective clinical study. A total of 119 cases(120 eyes)diagnosed as primary canaliculitis in the department of ophthalmology of Wuxi No.2 People's Hospital from June 2019 to February 2023 were included. The treatment methods were mainly divided into conservative treatment(removing canaliculus stones through lacrimal punctum combined with injecting antibiotic eye ointment into the tube)and surgical treatment. The inspection methods of pathogenic microorganisms included secretion smear microscopy and microbial culture.RESULTS: Primary canaliculitis was more common in middle-aged and older female, mainly manifested by long-term red eye and increased secretion; however, the majority was not accompanied by tearing. Totally, 118 cases(99.2%)had monocular disease, while 63 cases(63 eyes; 52.5%)had inferior lacrimal canaliculus disease. Laboratory examination: Among 119 cases(120 eyes), 4 cases(4 eyes)did not undergo laboratory examination, and the other 115 cases(116 eyes)were as follows: Gram staining microscopy of secretion smear showed that Actinomyces were detected in 102 cases(103 eyes; 88.8%), while no fungus was detected; Microbial culture: 85 cases(86 eyes; 74.1%)were positive for bacterial culture. A total of 111 bacterial strains were cultured, which contained 26 types of bacteria. Among them, 32 strains were aerobic(28.8%); 26 strains were anaerobic(23.4%); and 53 strains were facultative anaerobic(47.7%). The most common bacteria were streptococcus(20 strains), staphylococcus(13 strains), Propionibacterium(10 strains), and capnocytophaga(10 strains). Only 4 cases(4 eyes; 3.4%)of microbial cultures were positive for Actinomyces. Fungus was negative in all microbial cultures. Treatment: Of the 119 cases(120 eyes), 114 cases(115 eyes; 95.8%)were cured by conservative treatment of removing lacrimal canaliculus stones through lacrimal punctum and intracanalicular ointment infiltration(IOI), while 5 cases(5 eyes)were not effective in conservative treatment; however, all of them were cured after surgical treatment, and the cure rate for primary canaliculitis was 100.0%.CONCLUSION: The incidence of primary canaliculitis is low, and it is prevalent in middle-aged and older female. Single lacrimal canaliculus is more common, which could be missed and misdiagnosed in clinic. Actinomyces is the major pathogen observed mostly in mixed infections, with heterogeneous strains, mainly anaerobic or facultative anaerobic bacteria. Streptococcus and Staphylococcus are the most common whereas fungal canaliculitis is rare. The cure rate of primary canaliculitis is high after diagnosis, and IOI method is recommended as the initial treatment of canaliculitis.
5.Biomechanical analysis on Vancouver BI periprosthetic femoral fractures fixed by a customized anatomical plate system
Jiaqi WANG ; Xiaozhong LUO ; Yi TONG ; Xiaobo LU ; Weixiang SHI ; Xin ZHOU ; Gang WU ; Yong DING ; Caidong ZHANG
Chinese Journal of Tissue Engineering Research 2024;28(24):3807-3813
BACKGROUND:At present,the use of a locking bone plate combined with steel wire or steel cable for the treatment of periprosthetic femoral fracture often adopts monocortical fixation,which is not stable and the proximal end of the bone cannot be achieved anatomically fitted by plate.The customized anatomical plate system can effectively solve this problem. OBJECTIVE:To explore the biomechanical strength of a customized anatomical plate system in fixation of Vancouver BI periprosthetic femoral fracture. METHODS:CT thin layer scanning data of normal femurs of 1 006 cases were selected and input into the MIMICS 21.0 software to establish the three-dimensional reconstruction model of the femur,which was set as the three-dimensional reconstruction group.56 complete human femoral specimens were selected as the femoral specimen group.The measured results of the two groups for femoral anatomical appearance were compared.If there was no significant difference between the two groups,the approximate appearance of a customized anatomical plate system was designed based on the measurement results in MIMICS 21.0 software and NX11.0 software.The customized anatomical plate system was designed and prepared according to the above measurement results.Eight pairs of frozen human femurs were selected to make Vancouver BI periprosthetic femoral fracture,which of the left were thin layer scanned by dual-source CT to obtain data.The data were transferred to determine the customized anatomical plate system model by the above design software.Eight sets of customized anatomical plate systems were ultimately produced,relying on the instrument company.The eight pairs of models were numbered 1-8.The left side was fixed with the customized anatomical plate system(customized anatomical plate system group);the right side was fixed with a metal locking plate system-large locking plate(claw plate group).L1-L4 and R1-R4 were subjected to vertical short-cycle loading test and vertical loading test.L5-L8 and R5-R8 were subjected to horizontal short-cycle loading test and four-point bending test.The vertical loading test and four-point bending test were used to collect bending load,bending displacement,and bending strain.Two short cycle loading tests were used to collect strain displacement to compare the maximum load,maximum displacement,bending stiffness,and short-period displacement resistance of the two kinds of bone plates. RESULTS AND CONCLUSION:(1)There were no significant differences in all indexes between the three-dimensional reconstruction group and the femoral specimen group(P>0.05).Individual customized anatomical plate system was designed based on the measurement results combined with digital software.(2)In the vertical loading test,the maximum load was higher(P=0.015),the maximum bending displacement was smaller(P=0.014),and the bending stiffness was higher(P=0.005)in the customized anatomical plate system group compared with the claw plate group.(3)In the four-point bending test,the maximum load was higher(P=0.023),the bending stiffness was higher(P=0.005),and the maximum bending displacement was not significant(P=0.216>0.05)in the customized anatomical plate system group compared with the claw plate group.(4)In the vertical short-cycle loading test,the average level of bending displacement in the customized anatomical plate system group(0.23±0.10 mm)was significantly lower than that in the claw plate group(0.44±0.02 mm)(P<0.05).(5)There was no significant difference in the average level of bending displacement between the two groups in the horizontal short cycle loading test(P>0.05).(6)It is concluded that the customized anatomical plate system has personalized anatomical characteristics,and the fixation of Vancouver BI periprosthetic femoral fracture is more stable,which has certain significance for clinical treatment.
6.Effect of Coptidis Rhizoma-Fermentum Rubrum on Non-Alcoholic Fatty Liver Disease in Mice Based on Nrf2/GPX4 Ferroptosis Axis
Yang YANG ; Xiaobo ZHANG ; Yong ZHANG ; Fuming LU ; Yaqi LUO ; Xiaoyi WU
Chinese Journal of Experimental Traditional Medical Formulae 2024;30(20):30-36
ObjectiveTo observe the effects of Coptidis Rhizoma-Fermentum Rubrum on non-alcoholic fatty liver disease (NAFLD) in mice and explore its possible mechanisms. MethodSixty male SPF C57BL/6J mice were randomly divided into six groups: control group, model group, low-, medium-, and high-dose Coptidis Rhizoma-Fermentum Rubrum group (0.75, 1.5, 3 g·kg-1), and metformin group (0.075 g·kg-1), with 10 mice in each group. NAFLD mouse models were induced by high-fat diet feeding for 24 weeks. The low, medium, and high-dose Coptidis Rhizoma-Fermentum Rubrum groups were administered corresponding doses of Coptidis Rhizoma-Fermentum Rubrum by gavage, while the control and model groups received an equivalent amount of saline for four weeks. Serum total cholesterol (TC), triglycerides (TG), free fatty acids (FFA), and liver function markers including alanine aminotransferase (ALT) and aspartate aminotransferase (AST) were measured using an automatic biochemical analyzer. Hematoxylin-eosin (HE) and oil red O staining were used to detect liver lipid deposition, and Prussian blue staining was used to measure liver ferrous ion levels. Western blot was performed to detect the expression of key proteins in the nuclear factor erythroid-2-related factor 2 (Nrf2)-glutathione peroxidase 4 (GPX4) axis. ResultAfter 24 weeks of high-fat feeding, compared with the control group, the model group showed significant increases in body weight, liver weight and liver index, and serum lipid levels (P<0.01), as well as substantial hepatic lipid deposition with marked steatosis. Compared with the model group, Coptidis Rhizoma-Fermentum Rubrum intervention reduced body weight (P<0.01), liver weight and liver index (P<0.01), and serum lipid levels (P<0.05, P<0.01), improved liver function (P<0.01), and decreased hepatic lipid deposition, with the low-dose Coptidis Rhizoma-Fermentum Rubrum group showing the best effect. Western blot results showed that compared with those in the control group, the expression levels of Nrf2, heme oxygenase-1 (HO-1), kelch-like ECH-associated protein 1(Keap1), and GPX4 proteins in the model group were decreased (P<0.05, P<0.01). Compared with the model group, Coptidis Rhizoma-Fermentum Rubrum increased the expression levels of these proteins (P<0.05, P<0.01). ConclusionCoptidis Rhizoma-Fermentum Rubrum can alleviate fatty liver in mice, improve liver function, and reduce hepatic lipid deposition, possibly by regulating the Nrf2/GPX4 ferroptosis axis.
7.Investigation on a suspected outbreak of carbapenem-resistant Acinetobacter baumannii nosocomial infection in an intensive care unit
Mei HUANG ; Xiaobo GUI ; Ya YANG ; Feng LU ; Juanxiu QIN ; Yan LI ; Shuyi ZHANG ; Wenqin ZHOU ; Xiaofang FU ; Haiqun BAN
Shanghai Journal of Preventive Medicine 2024;36(5):435-438
ObjectiveTo investigate a suspected outbreak of carbapenem-resistant Acinetobacter baumannii (CRAB) nosocomial infection in an intensive care unit (ICU) and provide scientific evidence for prevention and control of multi-drug resistant nosocomial infection. MethodsClinical and epidemiological data of 4 patients with CRAB infection were retrospectively investigated in the ICU of Renji Hospital in November 2021. Environmental hygiene monitoring and multilocus sequence typing (MLST) were conducted and intervention measures were taken. ResultsA total of 4 cases with CRAB infection were identified, among which 1 case was determined to be community-acquired and3 cases were hospital-acquired. The isolated strains shared the same drug resistance, and were all classified into ST368 type. In the surface and hand samples (n=40), 2 CRAB strains were detected in the air filter beside the bed of the first case, with a detection rate of 5%. After adopting comprehensive prevention and control strategies, including environmental cleaning and disinfection, hand hygiene, staff management and training, and supervision, no similar case with CRAB infection was found. ConclusionThis suspected outbreak of CRAB nosocomial infection may be induced by inadequate environmental cleaning and disinfection, and inadequate implementation of hand hygiene. Timely identification, investigation, and targeted measures remain crucial to effective control of possible nosocomial infection.
8.Low-level viremia in chronic hepatitis B patients treated with first-line treatment with nucleos(t)ide analogues and its treatment strategies
Journal of Clinical Hepatology 2024;40(5):880-883
Highly effective oral antiviral therapy with low drug resistance can strongly inhibit HBV replication;however,some patients may still have low-level viremia(LLV)after receiving entecavir,tenofovir disoproxil fumarate,tenofovir alafenamide,or tenofovir amibufenamide for 48 weeks or more.Multiple studies in China and globally show that LLV after antiviral therapy is closely associated with the progression of chronic hepatitis B liver fibrosis,the risk of decompensated liver cirrhosis and hepatocellular carcinoma,and the reduction in long-term survival rate.Therefore,this article reviews the development,risk factors,and clinical harm of LLV after first-line treatment with nucleos(t)ide analogues,as well as different treatment regimens,in order to provide a reference for the treatment of LLV in chronic hepatitis B patients in the future.
9.Contemporary strategies and approaches for characterizing composition and enhancing biofilm penetration targeting bacterial extracellular polymeric substances
Lu LAN ; Zhao YUTING ; Li MINGXING ; Wang XIAOBO ; Zhu JIE ; Liao LI ; Wang JINGYA
Journal of Pharmaceutical Analysis 2024;14(4):506-524
Extracellular polymeric substances(EPS)constitutes crucial elements within bacterial biofilms,facili-tating accelerated antimicrobial resistance and conferring defense against the host's immune cells.Developing precise and effective antibiofilm approaches and strategies,tailored to the specific charac-teristics of EPS composition,can offer valuable insights for the creation of novel antimicrobial drugs.This,in turn,holds the potential to mitigate the alarming issue of bacterial drug resistance.Current analysis of EPS compositions relies heavily on colorimetric approaches with a significant bias,which is likely due to the selection of a standard compound and the cross-interference of various EPS compounds.Considering the pivotal role of EPS in biofilm functionality,it is imperative for EPS research to delve deeper into the analysis of intricate compositions,moving beyond the current focus on polymeric materials.This ne-cessitates a shift from heavy reliance on colorimetric analytic methods to more comprehensive and nuanced analytical approaches.In this study,we have provided a comprehensive summary of existing analytical methods utilized in the characterization of EPS compositions.Additionally,novel strategies aimed at targeting EPS to enhance biofilm penetration were explored,with a specific focus on high-lighting the limitations associated with colorimetric methods.Furthermore,we have outlined the challenges faced in identifying additional components of EPS and propose a prospective research plan to address these challenges.This review has the potential to guide future researchers in the search for novel compounds capable of suppressing EPS,thereby inhibiting biofilm formation.This insight opens up a new avenue for exploration within this research domain.
10.The accuracy and feasibility study of freehand pedicle screw insertion for subaxial cervical spine assisted with safe core-referred technique
Wen TANG ; Lu LI ; Xiaobo LI ; Xingting QIU
Chinese Journal of Surgery 2024;62(3):202-209
Objectives:To construct the “safe core” of the pedicle screw trajectory using CT imaging data of the subaxial cervical spine in adults, and to assess the accuracy and feasibility of the pedicle screw insertion assisted with the “safe core-referred technique” for subaxial cervical spine with a cadaver specimen study.Methods:This is an experimental study. From January 2015 to March 2020,60 adults′ CT images data of the cervical spine were collected from the database of the First Affiliated Hospital of Gannan Medical University,and were imported into Mimics 20.0 software. Virtual cervical pedicle trajectory and safe core were constructed according to the self-designed “virtual construction method of pedicle in the subaxial cervical spine”. The success rate of the construction and the spatial position data of the virtual safe core of was recorded,including the distance between the safe core and the tangent line of the upper and lower outer edge of Luschka′s joint on coronal plane,and the distance between the safe core and the posterior edge of the vertebral body on sagittal plane.The 3.5 mm column was used to simulate the pedicle screw placement,using the safe core as the only hub in pedicle screw trajectory.The length of the anterior pedicle screw trajectory,the interval of the abductive angle of the pedicle screw in axial plane, and the projection area of the entry area on periapical radiograph was calculated.In addition,8 adult cervical cadaver specimens were collected for the pedicle screw insertion experiment.The left side group used the “safe core-referred technique” for pedicle screw insertion,while the right side group used the Abumi method for pedicle screw insertion.The accuracy of pedicle screw placement was verified by CT scan.The difference between the accuracy of subjective judgment based on X-ray monitoring of operator and the actual accuracy of pedicle screw insertion verified by CT scan was compared between the two groups.The chi-square test was used to compare the intergroup data.Results:The total success rate of the virtual construction method for the safe core of the subaxial cervical spine was 97.0% (291/300); The distance between the safe core and the tangent line of the upper and lower outer edge of Luschka′s joint on coronal plane was ( M(IQR)) 0.91 (0.98) mm (range: 0 to 1.85 mm);The distance between the safe core and the posterior wall on the sagittal plane of the vertebral body was (2.01±0.86) mm (range: 0.67 to 3.53 mm). The distance (anterior pedicle screw trajectory) from the posterior cortex to the central point of the safe core was (11.58±1.00)mm (range: 8.27 to 14.93 mm).The projection area of the entry point on the coronal plane was (36.18±11.67) mm 2 (range: 13.38 to 83.11 mm 2). Pedicle screw insertion experiment in cervical cadaver specimen showed the rate of intraoperative correction of the pedicle screw trajectory was 7.5% (3/40) in the experimental group and 12.5% (5/40) in the control group ( χ2=0.139, P=0.709). The operator ′s correct rate of subjective judgment on CT in the stage of pedicle screw trajectory preparation was 100% (40/40) in the experimental group and 82.5% (33/40) in the control group, the difference was statistically significant ( χ2=5.638, P=0.018). The actual correct rate of CT verification in the stage of pedicle screw insertion was 100% (40/40) in the experimental group and 90.0% (36/40) in the control group, the difference was statistically significant ( χ2=2.368, P=0.124); The operator ′s correct rate of subjective judgment in the stage of pedicle screw insertion completion was 100% (83/83) in the experimental group and 92.9% (79/85) in the control group ( χ2=4.199, P=0.040). Conclusions:The virtual safe-core of subaxial cervical spine can be use as a reliable anatomical fluoroscopy landmark for freehand pedicle screw insertion.“Safe core-referred technique” can improve the accuracy rate of the operator′s subjective judgment on the intraoperative fluoroscopy monitoring,and hence improve the accuracy of freehand pedicle screw insertion technology for subaxial cervical spine. And it still needs to be further verified in clinical practice.

Result Analysis
Print
Save
E-mail