1.Effect of personalized ETA appliance on mixed dentition stage patients with Class Ⅱ malocclusion
ZUO Xiang ; LI Qin ; ZHANG Youmeng ; CHEN Weixu ; MA Xiaokai ; LI Dongmei
Journal of Prevention and Treatment for Stomatological Diseases 2025;33(6):502-508
		                        		
		                        			Objective:
		                        			To explore the impact of personalized early treatment appliances (ETA) on the relationship between dental and maxillofacial structures in patients with ClassⅡ malocclusion during the replacement phase, and to provide a basis for clinical treatment.
		                        		
		                        			Methods:
		                        			This study was reviewed and approved by the Medical Ethics Committee, and informed consent was obtained from patients. From May 2023 to December 2023, 15 patients with Angle ClassⅡ malocclusion accompanied by mandibular retraction and anterior deep overjet during mixed dentition were enrolled in this study (8 males and 7 females; mean age 8.8 years). Each patient received a customized domestically manufactured ETA that was created based on dental arch dimensions, overjet severity, and occlusal relationships assessed from study models. Patients were instructed to wear the appliance for at least 2 hours during the day and throughout the night. The treatment duration was 6 months, at which time the changes in cephalometric data before treatment (T0) and after treatment (T1) were compared using Uceph software
		                        		
		                        			Results:
		                        			The angle between sella, nasion and supramentale point B (SNB) of the patients increased significantly by (1.03 ± 1.74°) compared to before treatment (P = 0.039). The angle between subspinale point A and supramentale point B (ANB), the distance between point A and point B on the FH plane (wits value), the overjet, and the overbite decreased by (0.47 ± 0.61°), (2.48 ± 2.11) mm, (2.48 ± 3.42) mm, and (0.79 ± 1.40) mm, respectively, compared to before treatment, and the differences were statistically significant (P<0.05). The angle between sella, nasion and subspinale point A (SNA), the angle between the FH and MP planes (FMA), the angle between the long axis of the L1 and MP plane (IMPA), the angle between the MP plane and SN plane (MP-SN), the distance from S to Go divided by the distance from N to Me (S-Go/N-Me), and the distance of the FH plane perpendicular from G point to the Pog point (G Vert Pog) increased compared to before treatment, while the angle between the SGn and FH planes (Y-axis) and the angle between the long axis of the L1 and FH plane (FMIA) decreased compared to before treatment, but there was no statistical difference (P>0.05).
		                        		
		                        			Conclusion
		                        			Personalized, customized ETA orthodontic appliances can effectively improve the sagittal and vertical relationships between the maxilla and mandible in patients with ClassⅡ malocclusion.
		                        		
		                        		
		                        		
		                        	
2.Clinical efficacy of Amplatzer duct occluder-Ⅱ device for the treatment of ventricular septal defect with aortic sinus prolapse in child patients
Chao ZUO ; Zhi CHEN ; Yunbin XIAO ; Zhou YANG ; Xiang WANG ; Yefeng WANG ; Jinxing XIANG
Journal of Interventional Radiology 2024;33(1):17-21
		                        		
		                        			
		                        			Objective To investigate the efficacy of Amplatzer duct occluder-Ⅱ device(ADO-Ⅱ)in treating ventricular septal detect(VSD)with aortic sinus prolapse(ASP)in child patients.Methods The clinical data of 94 child patients with VSD complicated by ASP,who were admitted to the Hunan Provincial Children's Hospital of China between January 2018 and September 2022,were retrospectively collected.The child patients included 60 males and 34 females with a mean age of(4.7±3.1)years.Mild-moderate ASP was seen in 83 child patients,with a mean(4.12±0.97)mm-sized VSD.Severe ASP was seen in 11 child patients,with a mean(4.95±0.51)mm-sized VSD.Perimembrane VSD was observed in 54 child patients and intracristal VSD in 40 child patients.The relationship of VSD size and degree of ASP to the selection of ADO-Ⅱ,postoperative middle period aortic valve regurgitation and residual leakage was analyzed,so as to clarify the applicability of ADO-Ⅱ to such child patients.Results In the postoperative middle period,6 child patients had mild aortic valve regurgitation,most seen in the child patients who received 4-4 mm or 5-4 mm ADO-occluder;and 10 child patients had residual leakage,mainly seen in the child patients who received 5-4 mm or 6-4 mm occluder.Conclusion In the condition when the ADO-Ⅱ occluder shows satisfactory placement pattern,this treatment is suitable for the child patient having<6 mm VSD with ASP.Although there are some residual leakage and aortic valve regurgitation after surgery,this interventional therapy still meets the clinical requirements.(J Intervent Radiol,2024,32:17-21)
		                        		
		                        		
		                        		
		                        	
3.Characteristics of abnormal coronary aorta origin in adults and cause analysis of missed diagnosis by transthoracic echocardiography
Si-Yang ZUO ; Sen LI ; You-Xiang KANG ; Xiao-Ling ZHAO ; Li-Xing WANG ; Rui CHEN ; Zhi-Yu FENG
Chinese Medical Equipment Journal 2024;45(1):71-75
		                        		
		                        			
		                        			Objective To analyze the characteristics of adult anomalous aortic origin of coronary artery(AAOCA)and the causes of missed diagnosis by transthoracic echocardiography(TTE)so as to facilitate TTE in diagnosing adult AAOCA.Methods A total of 37 adult patients with AAOCA diagnosed by non-invasive coronary CT angiography(CCTA)and/or invasive coronary angiography(ICA)were selected as research samples at some hospital from January 2019 to December 2022,and their clinical symptoms and the findings of 12-lead electrocardiogram,cardiac enzymes and TTE were summarized;the patients were typed according to the site of origin of coronary artery anomalies,and the causes for the missed diagnosis of TTE were eplored.Chi-square test was used to compare the differences in TTE missed diagnoses.Results Of the 37 patients,31 ones had no or only mild symptoms;most ones had negative results in terms of 12-lead electrocardiography,cardiac enzymes,changes in the size of the cardiac chambers,segmental ventricular wall motion abnormalities and left ventricular systolic function.The patients with anomalous origin of the right coronary artery from left sinus(ARCA-L)gained the largest proportion of 59.45%(22/37);21 patients were diagnosed with anomalous origin of coronary artery arising from the opposite sinus(ACAOS)in the two examinations of TTE,of whom there were 19 cases of ARCA-L,and the detection rate of ACAOS by TTE was 87.5%;all the 13 patients origins in branches and high-grade openings were missed by TTE.The detection rate of ACAOS by TTE was significantly higher than that of coronary artery anomalies originating in branches and in high openings,and the difference was statistically significant(21/24 vs 0/13,P<0.001).Conclusion Most adult AAOCA patients lack specificity in symptoms and related examination results.TTE has a high detection rate of ACAOS,while it is easy to miss the diagnosis of coronary artery anomalies originating from branches and high openings.Ultrasonographers have to identify false negative AAOCA by multi-section and multi-angle scanning and color Doppler flow imaging in order to reduce the rate of missed diagnosis.[Chinese Medical Equipment Journal,2024,45(1):71-75]
		                        		
		                        		
		                        		
		                        	
4.Environmental contamination related to the first patient with carbapenem-resistant Acinetobacter baumannii infection and the infection status of pa-tients in the intensive care unit in Tibetan areas
Cuo-Ta QIE ; Ding-Ying HE ; Fu-Yan LONG ; Xiao-Hua ZHANG ; Chun-Hua PENG ; Xiang-Xiang JIANG ; Ming-Lei DENG ; Cong FU ; Guo-Ping ZUO
Chinese Journal of Infection Control 2024;23(2):220-224
		                        		
		                        			
		                        			Objective To investigate the environmental contamination related to first patient with carbapenem-re-sistant Acinetobacter baumannii(CRAB)infection and the infection status of relevant patients in a newly established intensive care unit(ICU)of a hospital in Tibetan area,and analyze the transmission risk.Methods From the ad-mission in ICU of a patients who was first detected CRAB on November 15,2021 to the 60th day of hospitalization,all patients who stayed in ICU for>48 hours were performed active screening on CRAB.On the 30th day and 60th day of the admission to the ICU of the first CRAB-infected patient,environment specimens were taken respectively 2 hours after high-frequency diagnostic and therapeutic activities but before disinfection,and after disinfection but before medical activities.CRAB was cultured with chromogenic culture medium.Results Among the 13 patients who were actively screened,1 case was CRAB positive,he was transferred from the ICU of a tertiary hospital to the ICU of this hospital on November 19th.On the 40th day of admission to the ICU,he had fever,increased frequency for sputum suction,and CRAB was detected.The drug sensitivity spectrum was similar to that of the first case,and he also stayed in the adjacent bed of the first case.64 environmental specimens were taken,and 9 were positive for CRAB,with a positive rate of 14.06%,8 sampling points such as the washbasin,door handle and bed rail were positive for CRAB after high-frequency diagnostic and therapeutic activities.After routine disinfection,CRAB was detected from the sink of the washbasin.Conclusion For the prevention and control of CRAB in the basic-level ICU in ethnic areas,it is feasible to conduct risk assessment on admitted patients and adopt bundled prevention and con-trol measures for high-risk patients upon admission.Attention should be paid to the contaminated areas(such as washbasin,door handle,and bed rail)as well as the effectiveness of disinfection of sink of washbasin.
		                        		
		                        		
		                        		
		                        	
5.Concurrent chemoradiotherapy with or without nimotuzumab in the treatment of locally advanced nasopharyngeal carcinoma: a clinical study
Zhi YANG ; Quan ZUO ; Hexin DUAN ; Rong LIU ; Hui WU ; Jia CHEN ; Li XIONG ; Jieqi JIA ; Zhibi XIANG
Chinese Journal of Radiation Oncology 2024;33(2):103-109
		                        		
		                        			
		                        			Objective:To investigate the efficacy and side effects of concurrent chemoradiotherapy with or without nimotuzumab in the treatment of locally advanced nasopharyngeal carcinoma after neoadjuvant chemotherapy.Methods:In the prospective study, 100 patients with stage Ⅲ-Ⅳa locally advanced nasopharyngeal carcinoma (except T 3N 0M 0 stage) who met the inclusion criteria were randomly divided into the experimental and control groups using the random number table method. Patients in both groups were treated with neoadjuvant chemotherapy using TPF (paclitaxel liposome, cisplatin, and 5-fluorouracil) regimen for 2 cycles. At 2 weeks after chemotherapy, concurrent chemoradiotherapy plus nimotuzumab targeted therapy was given in the experimental group, and concurrent chemoradiotherapy was delivered in the control group. The main observation index was the distant metastasis-free survival (DMFS) rate. Log-rank test and multivariate Cox regression analysis were used. Results:The objective remission rate and complete remission rate in the experimental and control groups were 100% vs. 98% ( P=1.000) and 92.0% vs. 80% ( P=0.084). The 3-year DMFS in the experimental and control groups were 91.4 % vs. 76.1 % ( P=0.043). The 3-year progression-free survival (PFS), locoregional recurrence-free survival (LRFS) and overall survival (OS) in two groups were 87.3 % vs. 74.1 % ( P=0.097), 94.5 % vs. 85.6 % ( P=0.227) and 90.5% vs. 85.2% ( P=0.444). Subgroup analysis showed that patients with age<60 years ( HR=0.34, 95% CI=0.12-0.94, P=0.037), neutrophil-to-lymphocyte ratio (NLR)≤4 ( HR=0.34, 95% CI=0.13-0.89, P=0.028) received concurrent chemoradiotherapy plus nimotuzumab obtained better PFS. Multivariate analysis showed that NLR was an independent risk factor for disease progression ( HR=5.94, 95% CI=1.18-29.81, P=0.030) and distant metastasis ( HR=13.76, 95% CI=1.52-124.36, P=0.020). Conclusions:Compared with concurrent chemoradiotherapy alone, concurrent chemoradiotherapy combined with nimotuzumab after neoadjuvant chemotherapy can significantly increase DMFS rate for patients with locally advanced nasopharyngeal carcinoma. The incidence of side effects is similar in two groups. Concurrent chemoradiotherapy plus nimotuzumab after neoadjuvant chemotherapy may be a preferred treatment strategy for locally advanced nasopharyngeal carcinoma.
		                        		
		                        		
		                        		
		                        	
6.Comparative Analysis of Energy Consumption and Electricity Use between Thulium Fiber Laser Devices and Holmium Laser Devices For Treatment of Benign Prostate Hyperplasia
Xiao LIU ; Chao ZUO ; Xiang CHEN ; Yunwen ZHAO ; Sitong LI ; Jun TIAN ; Kai ZHANG
Chinese Hospital Management 2024;44(11):85-87,90
		                        		
		                        			
		                        			Objective It compared the power consumption and electrical parameters between Thulium fiber laser devices(TFL)and Holmium laser devices(HoL)in transurethral enucleation of prostate(TUEP).Methods A sin-gle surgeon conducted TUEP by THL or HoL in 10 patients respectively.The enucleation efficiency,the laser energy output and the electric parameters were recorded and analyzed.Results The data from both groups of surgeries were tested for normal distribution,and the t-test found that the difference in the enucleation efficiency between the two surgeries was not statistically significant(P=0.818),and the energy consumption indexes of the two devices were comparable.The difference in the total kilojoules of laser emission between the two lasers during surgery was not statistically significant(P=0.148),but the power consumption of the thulium laser was about one-tenth of that of the holmium laser(P<0.001),suggesting that the former utilised electrical energy significantly more efficiently than the latter.The maximum current of the HoL was significantly higher than that of the TFL(P<0.001),requiring a spe-cial high-power power outlet.Conclusion TFL was superior to HoL in terms of lower power consumption,higher en-ergy-efficient and electrical convenient in transurethral enucleation of the prostate.
		                        		
		                        		
		                        		
		                        	
7.Predictive value of left ventricular global longitudinal peak strain for the prognosis of septic patients
Lingyun ZUO ; Wenliang SONG ; Yongjun LIU ; Jianfeng WU ; Xiangdong GUAN ; Xiang SI
Chinese Critical Care Medicine 2024;36(4):353-357
		                        		
		                        			
		                        			Objective:To investigate the predictive value of left ventricular global longitudinal peak strain (GLPS) for the prognosis of septic patients.Methods:A prospective cohort study was conducted. Patients diagnosed with sepsis and admitted to the intensive care unit (ICU) of the First Affiliated Hospital, Sun Yat-sen University from December 2018 to November 2019 were enrolled. The patient characteristics, cardiac ultrasound parameters [left ventricular ejection fraction (LVEF), right ventricular ejection fraction (RVEF), four-dimensional ejection fraction (4DEF), GLPS] and cardiac biomarkers [N-terminal pro-brain natriuretic peptide (NT-proBNP), cardiac troponin T (cTnT)] within 24 hours of ICU admission, organ support therapies, severity of illness, and prognostic indicators were documented. The differences in clinical parameters between patients with varying outcomes during ICU hospitalization were assessed. Pearson correlation analysis was employed to explore the correlation between GLPS and other cardiac systolic parameters, as well as the associations between various cardiac systolic parameters and sequential organ failure assessment (SOFA) score. Receiver operator characteristic curve (ROC curve) was drawn to analyze the predictive capacity of cardiac ultrasound parameters and cardiac biomarkers for death during ICU hospitalization in septic patients.Results:A total of 50 septic patients were enrolled, with 40 surviving and 10 dying during ICU hospitalization, resulting in a mortality of 20.0%. All patients in the death group were male. Compared with the survival group, the patients in the death group were older, had a higher prevalence of diabetes mellitus, and received continuous renal replacement therapy (CRRT) more frequently, additionally, they exhibited more severe illness and had longer length of ICU stay. The levels of GLPS and cTnT in the death group were significantly elevated as compared with the survival group [GLPS: -7.1% (-8.5%, -7.0%) vs. -12.1% (-15.5%, -10.4%), cTnT (μg/L): 0.07 (0.05, 0.08) vs. 0.03 (0.02, 0.13), both P < 0.05]. However, no statistically significant difference was found in other cardiac ultrasound parameters or cardiac biomarkers between the two groups. Pearson correlation analysis revealed a negative correlation between GLPS and LVEF ( r = -0.377, P = 0.014) and 4DEF ( r = -0.697, P = 0.000), while no correlation was found with RVEF ( r = -0.451, P = 0.069). GLPS demonstrated a positive correlation with SOFA score ( r = 0.306, P = 0.033), while LVEF ( r = 0.112, P = 0.481), RVEF ( r = -0.134, P = 0.595), and 4DEF ( r = -0.251, P = 0.259) showed no significant correlation with SOFA score. ROC curve analysis indicated that the area under the ROC curve (AUC) of GLPS for predicting death during ICU hospitalization in septic patients was higher than other cardiac systolic parameters, including LVEF, RVEF, and 4DEF, as well as cardiac biomarkers NT-proBNP and cTnT (0.737 vs. 0.628, 0.556, 0.659, 0.580 and 0.724). With an optimal cut-off value of -14.9% for GLPS, the sensitivity and negative predictive value reached to 100%. Conclusion:GLPS < -14.9% within 24 hours of ICU admission in septic patients indicated a reduced risk of death risk during ICU hospitalization, while also correlating with the severity of organ dysfunction in this patient population.
		                        		
		                        		
		                        		
		                        	
8.Comparative Analysis of Energy Consumption and Electricity Use between Thulium Fiber Laser Devices and Holmium Laser Devices For Treatment of Benign Prostate Hyperplasia
Xiao LIU ; Chao ZUO ; Xiang CHEN ; Yunwen ZHAO ; Sitong LI ; Jun TIAN ; Kai ZHANG
Chinese Hospital Management 2024;44(11):85-87,90
		                        		
		                        			
		                        			Objective It compared the power consumption and electrical parameters between Thulium fiber laser devices(TFL)and Holmium laser devices(HoL)in transurethral enucleation of prostate(TUEP).Methods A sin-gle surgeon conducted TUEP by THL or HoL in 10 patients respectively.The enucleation efficiency,the laser energy output and the electric parameters were recorded and analyzed.Results The data from both groups of surgeries were tested for normal distribution,and the t-test found that the difference in the enucleation efficiency between the two surgeries was not statistically significant(P=0.818),and the energy consumption indexes of the two devices were comparable.The difference in the total kilojoules of laser emission between the two lasers during surgery was not statistically significant(P=0.148),but the power consumption of the thulium laser was about one-tenth of that of the holmium laser(P<0.001),suggesting that the former utilised electrical energy significantly more efficiently than the latter.The maximum current of the HoL was significantly higher than that of the TFL(P<0.001),requiring a spe-cial high-power power outlet.Conclusion TFL was superior to HoL in terms of lower power consumption,higher en-ergy-efficient and electrical convenient in transurethral enucleation of the prostate.
		                        		
		                        		
		                        		
		                        	
9.Comparative Analysis of Energy Consumption and Electricity Use between Thulium Fiber Laser Devices and Holmium Laser Devices For Treatment of Benign Prostate Hyperplasia
Xiao LIU ; Chao ZUO ; Xiang CHEN ; Yunwen ZHAO ; Sitong LI ; Jun TIAN ; Kai ZHANG
Chinese Hospital Management 2024;44(11):85-87,90
		                        		
		                        			
		                        			Objective It compared the power consumption and electrical parameters between Thulium fiber laser devices(TFL)and Holmium laser devices(HoL)in transurethral enucleation of prostate(TUEP).Methods A sin-gle surgeon conducted TUEP by THL or HoL in 10 patients respectively.The enucleation efficiency,the laser energy output and the electric parameters were recorded and analyzed.Results The data from both groups of surgeries were tested for normal distribution,and the t-test found that the difference in the enucleation efficiency between the two surgeries was not statistically significant(P=0.818),and the energy consumption indexes of the two devices were comparable.The difference in the total kilojoules of laser emission between the two lasers during surgery was not statistically significant(P=0.148),but the power consumption of the thulium laser was about one-tenth of that of the holmium laser(P<0.001),suggesting that the former utilised electrical energy significantly more efficiently than the latter.The maximum current of the HoL was significantly higher than that of the TFL(P<0.001),requiring a spe-cial high-power power outlet.Conclusion TFL was superior to HoL in terms of lower power consumption,higher en-ergy-efficient and electrical convenient in transurethral enucleation of the prostate.
		                        		
		                        		
		                        		
		                        	
10.Comparative Analysis of Energy Consumption and Electricity Use between Thulium Fiber Laser Devices and Holmium Laser Devices For Treatment of Benign Prostate Hyperplasia
Xiao LIU ; Chao ZUO ; Xiang CHEN ; Yunwen ZHAO ; Sitong LI ; Jun TIAN ; Kai ZHANG
Chinese Hospital Management 2024;44(11):85-87,90
		                        		
		                        			
		                        			Objective It compared the power consumption and electrical parameters between Thulium fiber laser devices(TFL)and Holmium laser devices(HoL)in transurethral enucleation of prostate(TUEP).Methods A sin-gle surgeon conducted TUEP by THL or HoL in 10 patients respectively.The enucleation efficiency,the laser energy output and the electric parameters were recorded and analyzed.Results The data from both groups of surgeries were tested for normal distribution,and the t-test found that the difference in the enucleation efficiency between the two surgeries was not statistically significant(P=0.818),and the energy consumption indexes of the two devices were comparable.The difference in the total kilojoules of laser emission between the two lasers during surgery was not statistically significant(P=0.148),but the power consumption of the thulium laser was about one-tenth of that of the holmium laser(P<0.001),suggesting that the former utilised electrical energy significantly more efficiently than the latter.The maximum current of the HoL was significantly higher than that of the TFL(P<0.001),requiring a spe-cial high-power power outlet.Conclusion TFL was superior to HoL in terms of lower power consumption,higher en-ergy-efficient and electrical convenient in transurethral enucleation of the prostate.
		                        		
		                        		
		                        		
		                        	
            

Result Analysis
Print
Save
E-mail