1.Status of Clinical Practice Guideline Information Platforms
Xueqin ZHANG ; Yun ZHAO ; Jie LIU ; Long GE ; Ying XING ; Simeng REN ; Yifei WANG ; Wenzheng ZHANG ; Di ZHANG ; Shihua WANG ; Yao SUN ; Min WU ; Lin FENG ; Tiancai WEN
Medical Journal of Peking Union Medical College Hospital 2025;16(2):462-471
Clinical practice guidelines represent the best recommendations for patient care. They are developed through systematically reviewing currently available clinical evidence and weighing the relative benefits and risks of various interventions. However, clinical practice guidelines have to go through a long translation cycle from development and revision to clinical promotion and application, facing problems such as scattered distribution, high duplication rate, and low actual utilization. At present, the clinical practice guideline information platform can directly or indirectly solve the problems related to the lengthy revision cycles, decentralized dissemination and limited application of clinical practice guidelines. Therefore, this paper systematically examines different types of clinical practice guideline information platforms and investigates their corresponding challenges and emerging trends in platform design, data integration, and practical implementation, with the aim of clarifying the current status of this field and providing valuable reference for future research on clinical practice guideline information platforms.
2.Finite element analysis of different fixation methods of partially threaded cannulated screws for treating vertical femoral neck fractures
Nengxian TAN ; Wenzheng WU ; Churong ZHENG ; Lieliang LUO ; Peng GU ; Chongzhi OUYANG ; Xiaohui ZHENG
Chinese Journal of Tissue Engineering Research 2024;28(6):873-878
BACKGROUND:The more vertical the femoral neck fracture line,the more shear force the femoral neck fracture may bear,so it may be prone to internal fixation failure,nonunion,or necrosis of the femoral head.At present,there is controversy as to which hollow nail fixation mode is ideal. OBJECTIVE:To evaluate different configurations and numbers of cannulated screw configurations to learn more about the biomechanical differences in vertical fractures of the femoral neck using finite element analysis. METHODS:Femoral CT data were collected from a 24-year-old healthy male volunteer and imported into Mimics software to build a three-dimensional geometric model of the femur.Model refinement and surface fitting processing were carried out in Geomagic software and imported into SolidWorks software to establish a vertical fracture model of the femoral neck.Six cannulated screw models were established,including three triangle configuration,three inverted triangle configuration,three double-plane double-support configuration(F scheme),three transverse configuration,four diamond configuration and four Alpha configuration.The peak stress,strain and displacement of internal fixation and femoral fracture models under different loads(350,700,1 400,and 2 100 N)were compared among different configurations. RESULTS AND CONCLUSION:(1)Under four kinds of loads,screw stress conditions were as follows:biplanar double-supported configuration(F scheme)>transverse configuration>inverted triangle configuration>positive triangular configuration>Alpha configuration>rhombus configuration.The peak value of Von mises stress was concentrated in the screw close to the fracture line.(2)Under four kinds of loads,the screw displacement was Alpha configuration>inverted triangle configuration>positive triangular configuration>biplanar double-supported configuration(F scheme)>rhombus configuration>transverse configuration,and the peak displacement was mainly concentrated on the hollow screw head.(3)Under four kinds of loads,the stress conditions of the proximal femoral bone block were biplanar double-supported configuration(F scheme)>transverse configuration>inverted triangle configuration>Alpha configuration>positive triangular configuration>rhombus configuration,and the stress peak mainly concentrated in the lower neck of femur.(4)Under 350 N load,the displacement of the proximal femur bone block was transverse configuration>biplanar double-supported configuration(F scheme)>positive triangular configuration>Alpha configuration>inverted triangle configuration>rhombus configuration.In the other three loads,the peak displacement of the inverted triangle configuration was smaller than that of the rhombus configuration.The peak displacement was mainly concentrated in the head.(5)The rhombus configuration was the most dispersed in the stress distribution of the proximal femoral bone.The rhombus configuration was the smallest in the peak displacement of the femur.The stress,displacement and peak displacement of the fracture end of each internal fixed model increased gradually with the increase of load.(6)The biomechanical performance of the four diamond-shaped models in the internal fixation of vertical femoral neck fractures is better than that of other groups of models.The four rhomboid models have stable fixation,small displacement value of fracture end and dispersed stress,which can help resist shear force and prevent varus collapse and create a good mechanical environment for fracture healing.
3.Oncological outcome of 3D-guided cone-shaped segmentectomy for deep early-stage lung cancer
Wenzheng XU ; Zhihua LI ; Xianglong PAN ; Zhicheng HE ; Jing XU ; Quan ZHU ; Weibing WU ; Liang CHEN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2024;31(10):1413-1421
Objective To investigate whether 3D-guided cone-shaped segmentectomy can achieve comparable long-term outcomes with lobectomy for deep early-stage lung cancer with diameter≤2 cm. Methods We retrospectively screened patients with deep early-stage non-small cell lung cancer (NSCLC) with diameter≤2 cm who underwent lobectomy or segmentectomy in the First Affiliated Hospital of Nanjing Medical University from 2012 to 2018. All pulmonary segmentectomy was performed using 3D-guided cone-shaped segmentectomy with segment or subsegment as the resection unit. Univariate and multivariate regression analyses were performed by Cox proportional hazard regression model. The patients who underwent segmentectomy and lobectomy were matched 1∶1 by propensity-score matching analysis. The oncological outcomes of two groups were compared. Results Our cohort was divided into a segmentectomy group (n=222) and a lobectomy group (n=127). The age, total nodule size, solid component size and proportion of pure solid nodule in the lobectomy group were significantly higher than those in the segmentectomy group. The median follow-up time was 49 months. Surgical margins were negative in all patients. The local recurrence rate of segmentectomy was 0.45%. The disease-free survival (DFS) rate and overall survival (OS) rate of patients in the segmentectomy group were significantly better than those in the lobectomy group (5-year DFS rate: 98.64% vs. 89.77%, P<0.001; 5-year OS rate: 99.55% vs. 92.10%, P<0.001). Multivariate regression analysis showed that the differences between two groups were not significant [DFS rate: HR=0.52. 95%CI (0.11, 2.59), P=0.427; OS rate: HR=0.08. 95%CI (0.00, 3.24), P=0.179] after adjusting for other factors. After propensity score matching, 77 patients were preserved in both segmentectomy group and lobectomy group, with the mean nodule size of 1.44 cm and 1.49 cm and the mean consolidation tumor ratio (CTR) of 0.46 and 0.52, respectively. There was no statistical difference in DFS rate (P=0.640) or OS rate (P=0.310) between the two groups. Conclusion 3D-guided cone-shaped segmentectomy can be an acceptable treatment for low-grade malignant NSCLC deep in lung parenchyma with diameter≤2 cm, and its oncology effect is not inferior to lobectomy.
4.Translocation of Hcp1 protein in type Ⅵ secretion system of Burkholderia pseudomallei mediates formation of multinucleated giant cells
Pan WU ; Chenglong RAO ; Dongqi NAN ; Jiangao CHEN ; Ziyuan ZHANG ; Wenzheng LIU ; Minyang WANG ; Jingmin YAN ; Qian LI ; Xuhu MAO
Journal of Army Medical University 2024;46(15):1721-1728
Objective To analyze the mechanism that Hcp1 protein in type Ⅵ secretion system of Burkholderia pseudomallei(B.pseudomallei)mediates the formation of multinucleated giant cells(MNGCs)when host cells are infected by the bacterium.Methods The mutant strain(BPC006 Δhcp1)and complementation strain(BPC006 Δhcp1::hcp1)were constructed by homologous recombination and plasmid complement technology,respectively.After RAW264.7 cells were infected with B.pseudomallei,the localization of Hcp1 in host cells was analyzed by immunofluorescence staining.The localization was further verified by cytoplasmic-membrane isolation in 293T cells after transfecting pCDNA4.1-Hcp1.The biological significance and effect of Hcp1 were explored by the anti-Hcp1 polyclonal antibody blocking and the formation of MNGC was detected by Giemsa staining.Results Western blotting showed that BPC006 Δhcp1 could not express Hcp1,while BPC006 Δhcp1::hcp1 restored Hcp1 expression.The above results proved that the mutant and complement strains were successfully constructed.Both cellular immunofluorescence co-localization and cytoplasmic-membrane isolation experiments showed that Hcp1 localized to host cell membranes.Last but not least,compared with the control group,anti-Hcp1 polyclonal antibodies inhibited the formation of MNGC(P<0.01).Conclusion Hcp1 protein in type Ⅵ secretion system of B.pseudomallei is able to translocate to the RAW264.7 cell membranes and plays an important role in the formation of MNGCs.
5.Phantom study based on MRI cine sequences: analysis of the accuracy of tumor motion range accuracy
Bing LI ; Yuan WANG ; Ronghu MAO ; Dong LIU ; Wenzheng SUN ; Xiangyue LIU ; Nan MENG ; Wei GUO ; Shuangliang CAO ; Xipan LI ; Chen CHENG ; Hui WU ; Hongyan TAO ; Dingjie LI ; Zhaoyang LOU ; Hongchang LEI ; Lingguang MENG ; Hong GE
Chinese Journal of Radiation Oncology 2024;33(12):1144-1151
Objective:To investigate the accuracy of magnetic resonance imaging (MRI) cine sequences in determining the range of tumor motion in radiotherapy, providing a basis for the precise delineation of the target volume in motion for radiation therapy.Methods:A modified chest motion phantom was placed in a MRI scanner, and a water-filled sphere was used to simulate a tumor. True fast imaging with steady precession (TrueFISP) MRI cine sequences from Siemens were used to capture the two-dimensional motion images of the simulated tumor. The phantom experiments were divided into three modes: head-foot motion mode, rotation motion mode, and actual respiratory waveform mode. In the head-foot motion mode, respiratory motion period (3, 4, 5, 6, 7 and 8 s), amplitude (5, 10 and 15 mm), and respiratory waveform of the simulated tumor (sin and cos4) were set, resulting in a total of 36 motion combinations. In the rotation motion mode, a cos4 waveform was used for respiration, with respiratory periods of 3, 4, 5, 6, 7 and 8 s, head-foot motion set amplitudes of 5, 10 and 15 mm, and anterior-posterior (AP) and left-right (LR) motion set amplitudes in three combinations ([2.5, 2.5] mm, [2.5, 5.0] mm, [5.0, 5.0] mm), resulting in a total of 54 motion combinations. In the actual respiratory waveform mode, respiratory waveforms of 5 randomly selected patients from Affiliated Cancer Hospital of Zhengzhou University were obtained. Under each motion combination, TrueFISP cine images (30 frames, with an acquisition time of 11 s per frame) were obtained. The code was used to automatically identify the two-dimensional coordinates of the center of the simulated tumor in each image, and sin and cos4 functions were separately employed to fit the tumor position in the motion direction, thereby obtaining the fitted motion period and amplitude. The difference between the maximum and minimum values of the tumor's center coordinates in the head-to-foot direction is taken as the range of movement, referred to as the calculated amplitude. For the actual respiratory waveform, the distance between the measured maximum and minimum positions is used to calculate the amplitude.Results:In the head-foot motion mode, the fitted amplitudes of both sin and cos4 waveforms deviated from the set amplitudes by 0-0.51 mm, with relative deviations of 0%-4.2%. The deviation range between the calculated amplitudes and the set amplitudes of the two waveforms were 0.08-0.94 mm, with relative deviations of 1.1%-6.3%. In the rotation motion mode, the fitted amplitudes deviated from the set amplitudes by 0-0.61 mm, with relative deviations of 0%-6.2%. And the deviation range between the calculated amplitudes and the set amplitudes were 0.16-0.94 mm, with relative deviations of 0%-6.3%. In the actual respiratory waveform motion mode, the deviation range between the calculated amplitudes and the set amplitudes were 0.10-0.48 mm, with relative deviations of 2.2%-8.6%.Conclusion:TrueFISP cine sequences show minimal deviations in determining the range of tumor head-foot motion and effectively captures the tumor's movement state, thereby providing important support for the precise definition of the tumor movement target area during radiotherapy .
6.Information management of blood glucose of perioperative patients in a public hospital
Tingting WU ; Xuemei GU ; Xueqin LU ; Wenzheng SHI ; Lianxu WEI ; Hongxia WANG
Chinese Journal of Hospital Administration 2024;40(9):718-722
Information construction helps hospitals to accurately manage the blood glucose levels of hospitalized patients and improve the quality and safety of medical care. In July 2022, a large tertiary public hospital launched an information management of perioperative patient blood glucose. By establishing a multidisciplinary support and information management team, building an information-based blood glucose management system, establishing standardized management processes, implementing automatic hierarchical blood glucose warning, blood glucose critical value warning and control, abnormal blood glucose consultation, and insulin pump management, the hospital had achieved the information sharing of blood glucose perioperative patients, as well as timely warning and handling of abnormal blood glucose, ensuring patient safety. As of June 2023, the hospital had deployed a total of 364 intelligent blood glucose meters in clinical departments, and monitored blood glucose levels for 12 216 perioperative patients. The blood glucose compliance rate of perioperative patients increased from 81.81% in July 2022 to 82.95% in June 2023. This practice brought convenience to the work of clinical departments, improved the overall quality of medical services in hospitals, and could provide references for other hospitals to carry out blood glucose information management.
7.Advances in indications of anatomical pulmonary segmentectomy for early-stage lung cancer
Weibing WU ; Wenzheng XU ; Liang CHEN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2023;30(04):627-634
Whether anatomical segmentectomy can replace lobectomy in the treatment of early-stage lung cancer remains controversial. A large number of studies have been conducted for decades to explore whether pulmonary segmentectomy can treat early-stage lung cancer, which is actually to explore the indications of intentional segment-ectomy. With the development of scientific researches, it is found that many characteristics affect the malignancy of lung cancer, and the different grades of each characteristic affect the prognosis of patients. It is worth exploring whether different surgical approaches can be used for early-stage lung cancer with different characteristics and different grades. This article reviews the literature and studies to discuss the advances in indications of segmentectomy for early-stage lung in terms of tumor size, consolidation-to-tumor ratio, pathological classification and tumor location, respectively. The objective of this review is to help thoracic surgeons to objectively and scientifically select the surgical method according to the clinical characteristics of early-stage lung cancer.
8.RNF43 inhibits PD-L1 expression via β-catenin in melanoma cells and promotes CD8 + T cell-mediated anti-tumor immune reaction
Minhang WU ; Wenzheng SUN ; Qingzhuo YU ; Rong GUO ; Hui YE ; Ying DU ; Jin QIU ; Huazhang AN ; Lili CAO
Journal of International Oncology 2023;50(7):407-412
Objective:To investigate the regulatory effects of ring finger protein 43 (RNF43) on CD8 + T cell-mediated anti-tumor immune reaction in melanoma. Methods:RNF43 gene was over-expressed and knockdown in mouse melanoma cells line B16-OVA by lentivirus infection; In vivo proliferation of mouse melanoma cells line B16-OVA in the Lv-Ctrl-OE, Lv-RNF43-OE, Lv-Ctrl-KD and Lv-RNF43-KD groups was detected by subcutaneous tumorigenesis assay in mice, and the expression levels of CD8 + T cells perforin and interferon γ (IFN-γ) in tumor immune microenvironment of melanoma were detected by flow cytometry; The expression levels of β-catenin and programmed death-ligand 1 (PD-L1) mRNA in cells were detected by quantitative real-time PCR assay; The effect of RNF43 on the transcriptional regulation of PD-L1 was detected by dual-luciferase reporter gene assay. Results:Stable RNF43 over-expressing and RNF43 knockdown mouse melanoma cells lines Lv-RNF43-OE and Lv-RNF43-KD were successfully constructed. The results of subcutaneous tumorigenesis experiment in mice showed that the tumor mass of the Lv-RNF43-OE group was (0.08±0.06) g, which was significantly smaller than that of the Lv-Ctrl-OE group [ (1.04±0.52) g], with a statistically significant difference ( t=3.71, P=0.032) ; The tumor mass of Lv-RNF43-KD group was (1.94±0.29) g, with no statistically significant difference ( t=-1.70, P=0.164) compared with that of the Lv-Ctrl-KD group (1.15±0.74) g. The flow cytometry results showed that the fluorescence intensity of CD8 + T cell perforin in the Lv-RNF43-OE group was 9 034 ± 2 628, which was significantly higher than that in the Lv-Ctrl-OE group (3 847 ±1 637), with a statistically significant difference ( t=-3.35, P=0.015) ; The fluorescence intensity of CD8 + T cell perforin in the Lv-RNF43-KD group was 966±247, which was significantly lower than that in the Lv-Ctrl-KD group (2 226±646), with a statistically significant difference ( t=3.16, P=0.034) ; The fluorescence intensity of IFN-γ of CD8 + T cell in the Lv-RNF43-OE group was 2 422±429, which was significantly higher than that of 1 688±324 in the Lv-Ctrl-OE group, with a statistically significant difference ( t=-2.73, P=0.034) ; The fluorescence intensity of IFN-γ of CD8 + T cell in the Lv-RNF43-KD group was 614 (454, 863), with a statistically significant difference ( Z=-1.96, P=0.050) compared with 1 159 (1 152, 2 068) in the Lv-Ctrl-KD group. The results of quantitative real-time PCR showed that the relative expression level of β-catenin mRNA in the Lv-RNF43-OE group was 0.67±0.16, which was significantly lower than that of 1.00±0.11 in the Lv-Ctrl-OE group, with a statistically significant difference ( t=2.98, P=0.041) ; The relative expression level of PD-L1 mRNA in the Lv-RNF43-OE group was 0.32±0.09, which was significantly lower than that of 1.00±0.09 in the Lv-Ctrl-OE group, with a statistically significant difference ( t=9.13, P=0.001). The results of the dual-luciferase reporter gene assay showed that the PD-L1 promoter luciferase activity in the pCMV6-NC, RNF43, RNF43+β-catenin and β-catenin groups were 1.00±0.00, 0.84±0.00, 1.49±0.00 and 1.57±0.03 ( F=2 218.33, P<0.001). Further pairwise comparison showed that compared with the pCMV6-NC group, PD-L1 promoter luciferase activity was significantly lower in the RNF43 group ( P<0.001) and significantly higher in the RNF43+β-catenin and β-catenin groups ( P<0.001; P=0.003) ; compared with the RNF43 group, PD-L1 promoter luciferase activity was significantly higher in the RNF43+β-catenin group ( P<0.001) . Conclusion:RNF43 may reduce the expression of PD-L1 mRNA in melanoma by inhibiting the expression of β-catenin and promote CD8 + T cell-mediated anti-tumor immune reaction.
9.A survey on sales characteristics and salt iodine content in urban and rural salt market of Guizhou Province
Xuan LI ; Yang LI ; Juan WANG ; Demei ZHOU ; Hong XIANG ; Wenzheng LIU ; Yutian WU
Chinese Journal of Endemiology 2022;41(4):305-308
Objective:To understand the sales characteristics and salt iodine content in urban and rural salt market of Guizhou Province.Methods:In accordance with the "Guizhou Province 2020 Iodine Deficiency Disorders Monitoring Field Technical Guidance Work Program", 14 counties (cities, districts) from 88 counties (cities, districts) of 9 cities (states) in Guizhou Province were selected in August 2020. Each county (city, district) selected the urban area and a representative township, and at least 2 supermarkets were selected from the urban area, and 5 supermarkets or retail stores from the townships as the investigation sites, to collect the label information of all commercially available salt within the scope of investigation. At the same time, salt samples were collected after excluding the same brand, variety, and specification, and salt iodine was detected by redox titration.Results:A total of 107 labels of commercially available salt were collected, involving 21 brands, of which Biyuan brand had the largest number (53 samples, 49.5%) and the widest sales range, involving 12 counties (cities, districts). Salt producing areas came from 13 provinces, and the salt produced in Sichuan Province was the most widely distributed in the surveyed area (36 samples), followed by Chongqing Municipality (17 samples) and Hubei Province (16 samples). There were 19 brands (75 samples) and 7 brands (32 samples) of salt sold in urban and rural areas, respectively, and the main brand was Biyuan, accounting for 38.7% (29/75) and 75.0% (24/32), respectively. There were 8 brands (27 samples) and 16 brands (80 samples) of salt sold in retail stores and supermarkets, respectively, and the main brand was Biyuan, accounting for 66.7% (18/27) and 43.8% (35/80), respectively. Among 107 salt samples, it was found that the labeled iodine content did not meet the Guizhou Province salt iodization implementation standard (21 - 39 mg/kg), and only 39 samples (36.4%) had electronic anti-counterfeiting traceability codes on their labels. After excluding the same brand, variety, and specification, the median salt iodine of the 51 salt samples was 23.6 mg/kg, ranging from 19.2 to 38.1 mg/kg, and 21 - 39 mg/kg accounted for 96.1% (49/51).Conclusions:There are many salt brands sold in urban and rural areas in Guizhou Province, and the electronic traceability platform needs to be improved. Salt iodine is mainly distributed in the low-value area of the standard range, which brings potential risks to the sustainable and effective prevention and control of iodine deficiency disorders.
10.Translobar Phenomenon of Pulmonary Veins and Its Clinical Significance in Lobectomy.
Wenzheng XU ; Zhihua LI ; Zhicheng HE ; Jing XU ; Weibing WU ; Liang CHEN
Chinese Journal of Lung Cancer 2021;24(2):99-107
BACKGROUND:
Lobectomy is the main treatment strategy for early lung cancer. However, there are many anatomical variations in the lungs, especially some pulmonary veins will deviate from the normal position, and even cross the border of lob to enter the adjacent lobes, which increases the difficulty and risk of lobectomy. This study aims to analyze the variation types and frequency of pulmonary translobar veins, and further investigate its clinical significance in lobectomy.
METHODS:
This study retrospectively included 916 patients who underwent lung resection in our center from December 2018 to November 2019, and selected 310 patients who underwent enhanced chest computed tomography (CT) examination before surgery. Enhanced chest CT and three-dimensional computed tomography bronchography and angiography (3D-CTBA) of these patients were applied to analyze the types and frequency of translobar veins. Further, 48 cases of lobectomy whose operation areas involved translobar veins were further screened out of 916 surgical cases (Among them, the translobar veins of 36 subjects were cut off and the other 12 patients were reserved). The effect of two different treatments on remaining lung was observed by surgical video.
RESULTS:
A total of 26 translobar veins patterns were identified with an overall incidence of 82.26%, much greater in the right than in the left lung (80.65% vs 11.94%). The major types (frequency >5%) in the right lung include: the VX2 (5.48%) that flows into the inferior pulmonary vein behind the intermediate bronchus, the V3b (58.39%) that converges the venous branches of the upper and middle lobe, the VX4 that flows into the V2 (13.23%) or V3 (12.58%) in the horizontal fissure, the VX4 (8.71%) or VX5 (7.42%) that flows into the left atrium beneath the middle lobe bronchus, and the VX6 that flows into V2 in the Oblique fissure. The major types in the left lung include the common trunk (9.36%) of the superior and inferior pulmonary vein, of which 4.84% are greater than 1 cm in length. Compared to the preserved group, circulatory function of the remaining lung was impaired in the severed group, with the impaired area failing to collapse long after ventilation is stopped, the incidence of postoperative hemoptysis (13.89% vs 0.00%) and pulmonary air leakage (19.44% vs 8.33%) increased, the postoperative hospital stay [(4.72±1.86) d vs (3.92±1.62) d] was longer, and the total drainage during 3 days after operation [(705.42±265.02) mL vs (604.92±229.64) mL] was more, but the difference is not statistically significant.
CONCLUSIONS
There are a variety of types of translobar pulmonary veins and some of them have a high incidence; However, most of the translobar veins were neglected in surgery, which could adversely affect the safety of surgery and the recovery of patients after surgery.

Result Analysis
Print
Save
E-mail