1.Diagnosis and treatment of genetically related urinary calculi
Wenzhao ZHANG ; Longhui LAI ; Peide BAI ; Tao WANG ; Anran SUN ; Yu LUO ; Kai ZHU ; Jinchun XING ; Zhangqun YE ; Bin CHEN
Chinese Journal of Urology 2022;43(6):477-480
In recent years, the incidence of single-gene nephrolithiasis has been increasing year by year. With the application of whole-genome analysis and whole-exome sequencing technology, the etiology of single-gene mutations leading to the development of urinary calculi has been extensively verified. Therefore, this article reviews the research on urinary calculi-related genetic diseases at home and abroad, and introduces transport proteins and channels; ions, protons and amino acids. The role of urinary calculi in the majority of clinicians realizes the significance of genetic testing in such diseases, thereby increasing the understanding of genetically related urinary calculi and improving the level of clinical diagnosis and treatment.
2.Effect of Jianpi Yishen Huazhuo Prescription on Ovarian Function in Rats with Polycystic Ovary Syndrome Based on NLRP3 Inflammatory Pathway
Miao CHEN ; Xiaoli DU ; Yahong FENG ; Xiaojing ZHANG ; Jiaqi LUO ; Jing WANG ; Nan NAN ; Wenzhao LIU ; Shasha XING ; Ruiying TIAN ; Li YANG ; Miao SUN ; Rui HE ; Dongmei CHEN ; Huiming MA
Chinese Journal of Experimental Traditional Medical Formulae 2022;28(20):61-70
ObjectiveTo explore the mechanism of Jianpi Yishen Huazhuo prescription in the improvement of ovarian function in polycystic ovary syndrome (PCOS). MethodSeventy female SD rats in SPF grade were randomly divided into 6 groups, 15 in the blank group and 15 in the model group, 10 in the metformin group (0.1 g·kg-1·d-1), and 10 in the low (1.275 g·kg-1·d-1), medium (2.55 g·kg-1·d-1), and high-dose (5.10 g·kg-1·d-1) Jianpi Yishen Huazhuo prescription groups. The blank group was given normal saline (10 mL·kg-1·d-1) by gavage and ordinary feed, and the other groups were given letrozole (1 mg·kg-1·d-1) by gavage combined with high-fat feed for 21 days to induce the model of PCOS. After modeling, the blank group and model group were given equal volume normal saline by gavage, and each drug group was given the corresponding dose of the drug by gavage for 30 days. The changes in body mass and fasting blood glucose (FPG) of rats before and after modeling were compared. Hematoxylin eosin (HE) staining was used to observe the morphological change in the ovaries of rats in each group. The serum levels of follicle stimulating hormone (FSH), luteinizing hormone (LH), testosterone (T), anti-Mullerian hormone (AMH), and estradiol (E2) were measured by enzyme-linked immunosorbent assay (ELISA), and the LH/FSH ratio was calculated. Immunohistochemical staining (IHC) and Western blot were used to detect the protein expression levels of nucleoside binding oligomerization domain protein like receptor 3 (NALP3), apoptosis-associated speck-like protein (ASC), cysteine protease-1 (Caspase-1), nuclear transcription factor-κB (NF-κB), interleukin-1β (IL-1β), interleukin-18 (IL-18), and interleukin-6 (IL-6) in the rat ovaries. ResultAs compared with the blank group, large follicles with polycystic expansion were found in the ovaries of the model group, no dominant follicles were found, the granular layer of follicles decreased and arranged loosely, and the number of corpus luteum decreased significantly. Serum T, LH, AMH and LH/FSH increased in the model group (P<0.05, P<0.01), while FSH and E2 decreased (P<0.05, P<0.01). The relative protein expression levels of NALP3, ASC, Caspase-1, NF-κB, IL-1β, IL-18, and IL-6 increased (P<0.05, P<0.01) in the ovaries of the model group. Compared with the model group, the low, medium, and high-dose Jianpi Yishen Huazhuo prescription groups and the metformin group showed growing follicles and corpus luteum at all levels, the number of cystic expanding follicles decreased, the thickness of follicular granular layer increased, the number of follicular fluid increased, mature follicles were visible, and the local morphology of oocytes was complete. Serum T, LH, AMH, and LH/FSH in these groups decreased (P<0.05, P<0.01), while E2 and FSH increased (P<0.05). The relative protein expressions of NALP3, ASC, Caspase-1, NF-κB, IL-1β, IL-18, and IL-6 in the ovaries of these groups decreased (P<0.05, P<0.01). There was no significant difference among the treatment groups. ConclusionBy inhibiting the activation of NLRP3 inflammasome, Jianpi Yishen Huazhuo prescription reduces the release of NALP3, ASC, Caspase-1, NF-κB, IL-18, IL-1β, and IL-6 inflammatory factors in ovarian tissues, regulates endocrine level, and effectively reduces PCOS inflammatory statu, so as to play a role in improving ovarian function.
3.Clinical Recommendations for Perioperative Immunotherapy-induced Adverse Events in Patients with Non-small Cell Lung Cancer.
Jun NI ; Miao HUANG ; Li ZHANG ; Nan WU ; Chunxue BAI ; Liang'an CHEN ; Jun LIANG ; Qian LIU ; Jie WANG ; Yilong WU ; Fengchun ZHANG ; Shuyang ZHANG ; Chun CHEN ; Jun CHEN ; Wentao FANG ; Shugeng GAO ; Jian HU ; Tao JIANG ; Shanqing LI ; Hecheng LI ; Yongde LIAO ; Yang LIU ; Deruo LIU ; Hongxu LIU ; Jianyang LIU ; Lunxu LIU ; Mengzhao WANG ; Changli WANG ; Fan YANG ; Yue YANG ; Lanjun ZHANG ; Xiuyi ZHI ; Wenzhao ZHONG ; Yuzhou GUAN ; Xiaoxiao GUO ; Chunxia HE ; Shaolei LI ; Yue LI ; Naixin LIANG ; Fangliang LU ; Chao LV ; Wei LV ; Xiaoyan SI ; Fengwei TAN ; Hanping WANG ; Jiangshan WANG ; Shi YAN ; Huaxia YANG ; Huijuan ZHU ; Junling ZHUANG ; Minglei ZHUO
Chinese Journal of Lung Cancer 2021;24(3):141-160
BACKGROUND:
Perioperative treatment has become an increasingly important aspect of the management of patients with non-small cell lung cancer (NSCLC). Small-scale clinical studies performed in recent years have shown improvements in the major pathological remission rate after neoadjuvant therapy, suggesting that it will soon become an important part of NSCLC treatment. Nevertheless, neoadjuvant immunotherapy may be accompanied by serious adverse reactions that lead to delay or cancelation of surgery, additional illness, and even death, and have therefore attracted much attention. The purpose of the clinical recommendations is to form a diagnosis and treatment plan suitable for the current domestic medical situation for the immune-related adverse event (irAE).
METHODS:
This recommendation is composed of experts in thoracic surgery, oncologists, thoracic medicine and irAE related departments (gastroenterology, respirology, cardiology, infectious medicine, hematology, endocrinology, rheumatology, neurology, dermatology, emergency section) to jointly complete the formulation. Experts make full reference to the irAE guidelines, large-scale clinical research data published by thoracic surgery, and the clinical experience of domestic doctors and publicly published cases, and repeated discussions in multiple disciplines to form this recommendation for perioperative irAE.
RESULTS:
This clinical recommendation covers the whole process of prevention, evaluation, examination, treatment and monitoring related to irAE, so as to guide the clinical work comprehensively and effectively.
CONCLUSIONS
Perioperative irAE management is an important part of immune perioperative treatment of lung cancer. With the continuous development of immune perioperative treatment, more research is needed in the future to optimize the diagnosis and treatment of perioperative irAE.
4.Impacts of different registration ranges on the accuracy of multiple metastases treated with tomotherapy
Hui LIU ; Yinglin PENG ; Wenzhao SUN ; Huilang HE ; Linghong ZHOU
Chinese Journal of Radiation Oncology 2020;29(5):354-357
Objective:To analyze the impacts of different registration ranges on the accuracy of multiple metastases treated with helical tomotherapy.Methods:According to the locations of target volumes, 28 patients with multiple metastases were divided into the head/chest group ( n= 15) and the chest/pelvis group ( n= 13). The CT and MVCT images acquired in first fraction were studied and compared in two groups, which were captured and matched with different registration ranges (all targets/the targets in proximity to the head/ the targets in proximity to the foot). The CTV MVCT volume coverage rate (CR) under the matched target volumes, the dice similarity coefficient (DSC) between the CTV CT and CTV MVCT, and the position deviation of the CTV geometric center were compared. Results:We observed similar results in the head/chest group and chest/pelvis group. Specifically, there was no significant difference in the CR, DSC and geometric center deviation between the two target regions when registered with all targets ( P>0.05). Regarding single target region registration, the DSC and geometric center deviation of this target were significantly superior to the other non-registered target ( P< 0.05). To a single target, the CR, DSC, and geometric center deviation obtained with registration presented the best performance, which was significantly greater than these parameters obtained with all targets registration, while the other side target area obtained the worst results ( P< 0.05). Conclusions:Registration of one target region may reduce the accuracy of other non-registered targets. We recommend that the image guidance ranges for multiple metastases treated with tomotherapy should include all target regions or independent registrations for different targets.
5.Biomechanical Properties of Porous Titanium Cages for Different Lumbar Interbody Fusion Surgeries
Zhenjun ZHANG ; Wenzhao LI ; Hui LI ; Zhenhua LIAO ; Qingzhu MENG ; Dawei SUN ; Xuejun SUN ; Weiqiang LIU
Journal of Medical Biomechanics 2019;34(3):E243-E250
Objective To study the biomechanical properties of porous titanium cages used for different lumbar interbody fusion surgeries. Methods The three-dimensional (3D) finite element model of the lumbar spine was constructed, and mechanical parameters of porous materials were obtained by mechanical test. The biomechanical properties of porous titanium cages in anterior lumbar interbody fusion (ALIF), posterior lumbar interbody fusion (PLIF), transforaminal lumbar interbody fusion (TLIF), direct lateral interbody fusion (DLIF) were compared. Results After lumbar interbody surgery, the predicted range of motion (ROM) and the maximum stress in cage of DLIF model and ALIF model were substantially lower than those of PLIF model and TLIF model. The maximum stress in endplate of DLIF model, ALIF model and TLIF model were obviously lower than that of PLIF model. Conclusions DLIF with the porous cage showed advantages in biomechanical properties, which was simple to operate and suitable for minimally invasive surgery in clinical practice. DLIF performed the superior comprehensive properties.
6. Interobserver variations in the delineation of planning target volume and with orgagans at risk different contouring methods in intensity-modulated radiation therapy for nasopharyngeal carcinoma
Yinglin PENG ; Wenzhao SUN ; Wanqin CHENG ; Haiqun XIA ; Jijin YAO ; Weiwei XIAO ; Guanzhu SHEN ; Lin YANG ; Shu ZHOU ; Jiaxin LI ; Ying GUAN ; Shuai LIU ; Xiaowu DENG
Chinese Journal of Radiation Oncology 2019;28(10):762-766
Objective:
To assess the interobserver variations in delineating the planning target volume (PTV) and organs at risk (OAR) using different contouring methods during intensity-modulated radiation therapy (IMRT) for nasopharyngeal carcinoma (NPC), aiming to provide references for the quality control of multi-center clinical trials.
Methods:
The PTV and OAR of CT image of 1 NPC patient manually delineated by 10 physicians from 8 different radiation centers were defined as the " manual contour group" , and the OAR auto-contoured using the ABAS software and modified by the physicians were defined as the " auto+ manual contour group" . The maximum/minimum ratio (MMR) of the PTV and OAR volumes, and the coefficient of variation (CV) for different delineated contours were comparatively evaluated.
Results:
Large variation was observed in the PTV and OAR volumes in the manual contour group. The MMR and CV of the PTV were 1.72-3.41 and 0.16-0.39, with the most significant variation in the PTVnd (MMR=3.41 and CV=0.39 for the PTVnd-L). The MMR and CV of the manually contoured OAR were 1.30-7.89 and 0.07-0.67. The MMR of the temporal lobe, spinal cord, temporomandibular joint, optic nerve and pituitary gland exceeded 2.0. Compared with the manual contour group, the average contouring time in the auto+ manual group was shortened by 68% and the interobserver variation of the OAR volume was reduced with an MMR of 1.04-2.44 and CV of 0.01-0.37.
Conclusions
Large variation may occur in the PTV and OAR contours during IMRT plans for NPC delineated by different clinicians from multiple medical centers. Auto-contouring+ manually modification can reduce the interobserver variation of OAR delineation, whereas the variation in the delineation of small organs remains above 1.5 times. The consistency of the PTV and OAR delineation and the possible impact upon clinical outcomes should be reviewed and evaluated in multi-center clinical trials.
7. Current applications of artificial intelligence in tumor histopathology
Shan ZHENG ; Fenglong SUN ; Huijuan ZHANG ; Wenzhao SHI ; Jianhui MA
Chinese Journal of Oncology 2018;40(12):885-889
The tasks of artificial intelligence (AI) in tumor histopathology include image segmentation and classification. Currently, the specific contents including lymph node metastasis, pathological classification, grade and prognostic evaluation of malignant diseases, such as breast cancer, lung cancer and prostate cancer, have been studied by AI. Evaluation of sentinel lymph node metastasis of breast cancer has been the most mature application of AI technology, whose level can be analogous to the excellent pathologists. In the future, with the close cooperation of pathologists and engineers, the research of AI will be focus on improving the technology of simple and repetitive clinical diagnosis and differential diagnosis, such as the diagnosis of sentinel lymph node metastasis of breast cancer from biopsy frozen section and the judgment of incisal margin. Ultimately, AI will help us to precisely diagnose the tumor.
8.Comparative study on application effect of artificial nose and heating humidification combination device in high altitude area
Zunzhu LI ; Jianhua SUN ; Yangzong DEJI ; Zhen LI ; Yan XIE ; Hong SUN ; Wenzhao CHAI
Chinese Journal of Practical Nursing 2018;34(36):2811-2815
Objective To investigate the application and effect evaluation of combined warming and humidification device in patients with artificial airway in high altitude area. Methods The convenient sampling method was used to select 225 hospitalized patients in the Department of Critical Care Medicine of the People′s Hospital of Tibet Autonomous Region from January to June 2018. According to the order of admission time, they were divided into two groups: observation group (125 cases) and control group (100 cases). The observation group was humidified by artificial nose, while the control group was humidified by heating and humidifying device. The phlegm properties and scab formation were observed in the two groups. The ambient temperature, humidity and airway temperature were measured at 3:00, 9:00, 15:00 and 21:00 every day. The average values of four measurements were taken. The levels of CO2 partial pressure and oxygen partial pressure were recorded by blood gas analysis. χ2was used to compare the differences between the 2 groups. Results There was no difference in sputum properties between the two groups before humidification. The incidence of grade II and grade III mucous phlegm in the observation group was 46, 48 and 65 on the first, second and third day after humidification, while that in the control group was 13, 9 and 10 respectively. The difference between the two groups was statistically significant (χ2=16.266, 25.387, 44.100, P<0.01). On the 2nd and 3rd day, the oxygen partial pressure levels of the observation group were (92.62 ± 5.73), (91.34 ± 4.82) mmHg, and those of the control group were (96.17 ± 3.60), (95.53 ± 2.96) mmHg, respectively. The difference between the two groups was statistically significant (t=5.697, 8.045, P<0.01). The sputum scab formation and airway temperature in the observation group were 41 cases and(29.89±1.95)℃ respectively after 3 days of humidification, 7 cases and(34.79±1.82)℃respectively in the control group. The difference between the two groups was statistically significant (χ2= 22.035, t =- 26.031, P < 0.01). Conclusion The combination of heating and humidifying device can effectively improve the sputum properties, reduce the formation of sputum scab, effectively improve the level of carbon dioxide, without increasing the workload.
9.Dosimetric characterization of a novel dual-energy medical linear accelerator without a flattening filter
Xin YANG ; Wenzhao SUN ; Li CHEN ; Guangwen LUO ; Maosheng LIN ; Xiaoyan HUANG
Chinese Journal of Radiation Oncology 2017;26(2):203-209
Objective To study the dosimetric characteristics of flattened and flattening filter free (FFF) beams with 6 MV and 10 MV photon energy using a novel dual-energy medical linear accelerator (Elekta Versa HDTM),to identify the dosimetric characteristics and advantages of FFF beams,and to provide a basis for their clinical application.Methods The percentage depth dose (PDD),profiles/dose rate of off-axis ratio (OAR),field size,penumbral width,dose out of the fields,collimator scatter factor (Sc),and total scatter factor (Sc,p) were compared between flattened and FFF beams.Results (1) After beam energy matching,the FFF beams had the same beam energy with the flattened beams.The matching error of PDD at a depth of 10 cm was less than 1% between fields.(2) The FFF beams had a smaller variation in dose rate of OAR with the depth than the flattened beams.(3) The FFF beams had smaller variations in field size and penumbral width than the flattened beams.Moreover,the penumbral width of the FFF beams increased with the increasing field size or depth.The FFF beams had a lower dose out of the fields than the flattened beams.(4) The FFF beams had smaller variations in Sc and Sc,p with the field size and depth than the flattened beams.Conclusions Removal of the flattening filter can substantially improve the dose rate,shorten radiotherapy time,and reduce leakage and scattering of the head.The dosimetric advantages make the FFF beams appropriate for clinical treatment.
10.Correction of enhanced dynamic wedge factor and analysis of monitor unit calculation.
Sijuan HUANG ; Lixin CHEN ; Wufei CAO ; Wenzhao SUN ; Along CHEN ; Bojio LIU ; Bin WANG
Journal of Southern Medical University 2015;35(2):260-263
OBJECTIVETo study the correction of algorithm for Varian enhanced dynamic wedge(EDW) factors and compare the dose/monitor unit (MU) deviation measured at the central axis of EDW field with that obtained by manual calculation or using the treatment planning system.
METHODSEDW factors and dose were measured with Thimble ion chamber at 10 cm depth under the water for 6 MV and 10 MV photon on Varian linear accelerator. The corresponding calculations were done with the radiation treatment planning system. An analytic formula, namely the MU Fraction model, was used to calculate the EDW factor, which was corrected with a constant factor. The MU of conventional 2-D planning derived from manual calculating, treatment planning system, and actual measurements were compared.
RESULTSWith the measured results as the standard, the corrected manual calculation deviation of EDW factors was significantly reduced. For photon 6 MV, the maximum deviation reduced from 4.2% to 1.3% for 60° symmetry fields was, and from -4.7% to -1.8% for asymmetric fields. For photon 10 MV, the maximum deviation for all EDW fields was reduced from -3.0% to 1.1%. Comparison of the manual calculations with the measured results showed a MU deviation for symmetric fields within 2%, and more than 5% for some asymmetric fields. The deviation between the calculations of the treatment planning and the measured results was less than 1.5%.
CONCLUSIONConstant factor correction can effectively reduce the deviation of manual calculation. For MU calculation of EDW field in conventional 2-D dimensional treatment planning, the corrected results of symmetric fields meet clinical requirements. While the minimum distance between the field edge and the central axis was less than 4 cm in asymmetric fields, the corresponding special method, measurement or the treatment planning system should be used to calculate the dose/MU.
Algorithms ; Models, Theoretical ; Particle Accelerators ; Radiotherapy Dosage ; Radiotherapy Planning, Computer-Assisted

Result Analysis
Print
Save
E-mail