1.Safety analysis of Yttrium-90 resin microsphere selective internal radiation therapy on malignant liver tumors
Jia CAI ; Shiwei TANG ; Rongli LI ; Mingxin KONG ; Hongyan DING ; Xiaofeng YUAN ; Yuying HU ; Ruimei LIU ; Xiaoyan ZHU ; Wenjun LI ; Haibin ZHANG ; Guanwu WANG
Chinese Journal of Clinical Medicine 2025;32(1):24-29
Objective To explore the safety of Yttrium-90 resin microsphere selective internal radiation therapy (90Y-SIRT) on malignant liver tumors. Methods A retrospective analysis was conducted on 64 patients with malignant liver tumors who underwent 90Y-SIRT from February 2023 to November 2024 at Weifang People’s Hospital. The clinical characteristics of the patients and the occurrence of adverse reactions after treatment were analyzed to assess the safety of 90Y-SIRT. Results Among the 64 patients, there were 52 males (81.25%) and 12 females (18.75%); the average age was (56.29±11.08) years. Seven patients (10.94%) had tumors with maximum diameter of less than 5 cm, 38 patients (59.38%) had tumors with maximum diameter of 5-10 cm, and 19 patients (29.68%) had tumors with maximum diameter of greater than 10 cm. There were 47 cases (73.44%) of solitary lesions and 17 cases (26.56%) of multiple lesions; 53 cases (82.81%) were primary liver cancers and 11 cases (17.19%) were metastatic liver cancers. Of the 64 patients, 63 successfully completed the Technetium-99m macroaggregated albumin (99mTc-MAA) perfusion test and received the 90Y-SIRT; one patient received 90Y-SIRT after the second 99mTc-MAA perfusion test due to a work error. The most common adverse reactions included grade 1 alanine aminotransferase (ALT) elevation in 26 cases (40.62%) and grade 2 in 2 cases (9.37%), grade 1 aspartate aminotransferase (AST) elevation in 27 cases (42.18%) and grade 2 in 7 cases (10.93%); grade 1 nausea in 17 cases (26.56%) and grade 2 in 6 cases (9.37%); grade 1 abdominal pain in 12 cases (18.75%), grade 2 in 5 cases (7.81%), and grade 3 in 1 case (1.56%); grade 1 vomiting in 11 cases (17.18%), grade 2 in 5 cases (7.81%), and grade 3 in 1 case (1.56%). Conclusion The adverse reactions of 90Y-SIRT for treating malignant liver tumors are mild, indicating good safety.
2.Impact of peripheral blood inflammatory markers on neovascular glaucoma secondary to diabetic retinopathy
Mingfang WANG ; Wenwen ZHU ; Deyu XIA ; Dengrui XU ; Yawen SHI ; Hongchen FU ; Qian ZHAO ; Xiuyun LI
International Eye Science 2025;25(6):1005-1008
AIM: To investigate the influence of relevant inflammatory markers in peripheral blood on the progression of neovascular glaucoma(NVG)secondary to diabetic retinopathy(DR)patients.METHODS: Retrospective case-control study. Patients were categorized into two groups based on the presence or absence of NVG: those with proliferative diabetic retinopathy(PDR)alone(PDR group, n=148)and those with NVG secondary to PDR(NVG secondary to PDR group, n=142). Peripheral blood inflammatory markers were evaluated, including white blood cell-related indices, neutrophil-to-lymphocyte ratio(NLR), platelet-to-lymphocyte ratio(PLR), monocyte-to-lymphocyte ratio(MLR), and systemic immune-inflammation index(SII). The distinctions in peripheral blood inflammatory markers between the two groups of patients and their relationships with NVG secondary to PDR were analyzed.RESULTS:No statistically significant differences were observed in basic characteristics between the two groups, confirming their comparability. However, significant differences were found in eosinophil percentage and MLR between the PDR group and the NVG secondary to PDR group(all P<0.05), with both values being significantly higher in the NVG secondary to PDR group. Multivariate Logistic regression analysis revealed that the eosinophil percentage and the MLR were factors influencing the development of patients with NVG secondary to PDR.CONCLUSION: Eosinophil percentage and MLR may be associated with the progression of PDR to NVG, and could serve as potential predictive markers for NVG development in PDR patients.
3.Impact of inhaled corticosteroid use on elderly chronic pulmonary disease patients with community acquired pneumonia.
Xiudi HAN ; Hong WANG ; Liang CHEN ; Yimin WANG ; Hui LI ; Fei ZHOU ; Xiqian XING ; Chunxiao ZHANG ; Lijun SUO ; Jinxiang WANG ; Guohua YU ; Guangqiang WANG ; Xuexin YAO ; Hongxia YU ; Lei WANG ; Meng LIU ; Chunxue XUE ; Bo LIU ; Xiaoli ZHU ; Yanli LI ; Ying XIAO ; Xiaojing CUI ; Lijuan LI ; Xuedong LIU ; Bin CAO
Chinese Medical Journal 2024;137(2):241-243
4.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
5.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
6.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
7.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
8.Establishment and application of an artificial intelligence-assisted platform for detection of parasite eggs
Huiyin ZHU ; Yuting LI ; Daiqian ZHU ; Yaqian WANG ; Jinhong ZHANG ; Shaoxuan CHEN ; Xiaoyuan MA ; Huidi WANG ; Hongjun LI ; Jian LI
Chinese Journal of Schistosomiasis Control 2024;36(6):643-648
Objective To establish an artificial intelligence (AI)-assisted platform for detection of parasite eggs, and to evaluate its detection efficiency and accuracy, so as to provide technical supports for elimination of parasitic diseases. Methods A total of 1 003 slides of Enterobius vermicularis, horkworm, Trichuris trichiura, Clonorchis sinensis, Taenia, Ascaris lumbricoides, Schistosoma japonicum, Paragonimus westermani and Fasciolopsis buski eggs were collected, and converted into digital images with an automatated scanning microscope to create a dataset. Based on the Object Detection platform on the Baidu Easy DL model, an AI-assisted platform for detection of parasite eggs was created through procedures of uploading, labeling, training, evaluation and optimization. Then, 70% of the datasets were randomly selected for model training, and the precision, recall and average accuracy were calculated to evaluate the effectiveness of platform for recognition of parasite eggs. In addition, the platform was deployed on the computer and smart phone terminals for use. Results An AI-assisted platform for detection of parasite eggs was successfully created. If the platform was deployed using the public cloud application programming interface (API), the average accuracy, precision and recall of the platform were 93.42%, 92.55% and 89.32% for recognition of parasite eggs. If the platform was deployed using the offline software development kit (SDK), the average accuracy, precision and recall of the platform were 92.97%, 94.78% and 87.63% for recognition of parasite eggs. In addition, the precision of the platform was 97.00% and 96.23% for identification of Taenia and C. sinensis eggs, respectively. Conclusions The AI-assisted platform for detection of parasite eggs has been successfully created, which is high in the accuracy for recognition of parasite eggs and convenient in use. This platform may provide a powerful technical support for parasitic disease diagnosis.
9.Role of lipid metabolism in the progression and treatment of neovascular age-related macular degeneration
Weichen SONG ; Wen CHEN ; Jingyi CHI ; Wenwen ZHU
International Eye Science 2024;24(9):1432-1437
Neovascular age-related macular degeneration(nARMD)is a prevalent age-related retinal disease that significantly impairs vision. Numerous studies have shown that lipid metabolism disorders contribute to the progression of nARMD. The relationship is complex and involved factors such as fatty acids, cholesterol, variations in lipid metabolism genes, and other influencing factors. Lipid metabolism disorders lead to retinal vascular abnormalities and inflammatory responses by triggering oxidative stress and inhibiting autophagy. This, in turn, accelerates the formation of new blood vessels and causes damage to macular cells and tissues. In animal experiments, drugs designed for lipid metabolism disorders have shown that regulating lipid metabolism could be a potentially effective strategy for treating nARMD. This article reviews the role of lipid metabolism in the progression and treatment of neovascular age-related macular degeneration, aiming to offer new insights for nARMD treatment.
10.n-3 polyunsaturated fatty acids ameliorate learning and memory abilities in APPPS1 mice by regulating microglial activation and polarization
Mengyan DENG ; Xiaohui ZHU ; Li HUANG ; Qian BAI ; Weifang LI ; Bin WANG ; Mantian MI
Journal of Army Medical University 2024;46(9):928-939
Objective To construct a model of Fat-1/APPPS1 transgenic mice and a cellular model of microglia and explore the improvement effect and underlying mechanism of n-3 polyunsaturated fatty acids(n-3 PUFAs)on the learning and memory abilities of APPPS1 mice by regulating microglial activation and polarization.Methods After the male mice with heterozygous Fat-1 genotype were mated with the female ones with heterozygous APPPS1 genotype,genetic identification was used to screen the male offspring with Fat-1/APPPS1 genotype.Then after the male wild-type(WT)mice and those with Fat-1,Fat-1/APPPS1,and APPPS1 genotypes were bred until 9 months old,their learning and memory abilities were evaluated with Morris water maze(MWM)test.In addition,gas chromatography-mass spectrometry(GC-MS)was performed to detect the concentration of PUFAs in the brain,and immunohistochemistry(IHC)was applied to detect the deposition of β-amyloid protein(Aβ)in the hippocampal regions.Moreover,immunofluorescence assay,qRT-PCR,and enzyme-linked immunosorbent assays(ELISA)were conducted to measure inflammation,and transcription and expression of Iba-1(indicating the microglial activation)and CD86 and CD206(indicating microglial polarization)in central nervous system(CNS).After pretreated with DHA+EPA(25 pmol/mL∶25 μmol/mL),microglial model of inflammatory injury was established in immortalized mouse BV2 cells induced by LPS(1 μg/mL).Afterwards,immunofluorescence assay,qRT-PCR and Western blotting were used to detect inflammation and microglial activation and polarization.Results Compared with the APPPS1 mice,endogenous n-3 PUFAs effectively improved the learning and memory disorders in Fat-1/APPPS1 ones(P<0.05),remarkably alleviated Aβ deposition in the hippocampal regions(P<0.05),evidently reduced CNS inflammation and microglial activation(P<0.05)and transformed the activated microglia from M1 to M2(P<0.05).Furthermore,BV2 cells with DHA+EPA pretreatment obviously resisted LPS-induced cellular inflammation and induced activated ones from M1 to M2(P<0.05).Conclusion n-3 PUFAs inhibit the microglial activation,regulate the microglial polarization from M1 to M2,reduce CNS inflammation,and thus alleviate learning and memory disorders in APPPS1 mice.

Result Analysis
Print
Save
E-mail