1.Prediction and diagnosis of immune checkpoint inhibitor-related adverse eventsnoma cells via matrix metalloproteinase-9
Chinese Journal of Cancer Biotherapy 2025;31(8):793-798
[摘 要] 以免疫检查点抑制剂(ICI)为主的免疫治疗在激活T细胞、解除免疫抑制的同时可诱发免疫相关不良反应(irAE)。随着ICI在实体瘤中的广泛应用,irAE已成为临床常见问题,严重影响免疫治疗持续获益和患者生活质量。因此,应用ICI前需进行患者基线评估,如对有自身免疫性疾病、器官移植、病毒感染等特殊人群评估获益与风险。同时,irAE的预测及早期识别很重要,应结合临床因素,如基础性疾病、既往用药及治疗史;宿主因素,如肠道菌群及特定基因多态性;以及生物标志物,包括肿瘤突变负荷、炎症指标、自身抗体等综合预测irAE。此外,irAE的早期症状,如乏力、咳嗽、胆红素升高、转氨酶升高等需要与感染、肿瘤进展、非ICI相关的不良反应鉴别。irAE属于排除性诊断,还需借助影像、病理及多学科会诊等手段鉴别。积极开展irAE的机制研究及前瞻性临床试验有助于推动irAE的精准预测与治疗发展。
2.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
3.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
4.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
5.A Potential Novel Targeted Drug for the Treatment of Pulmonary Arterial Hypertension:Imatinib
Shanshan XIE ; Ye LI ; Lingling YU ; Jinjin WAN ; Zhiying HUANG ; Huanyu LIN ; Weifang ZHANG
Herald of Medicine 2024;43(2):262-266
Pulmonary hypertension has a high mortality rate,and although targeted therapy is available,it is still incurable,and the long-term prognosis for patients is poor.As a tyrosine kinase inhibitor,imatinib was approved for marketing in China in 2002 for the treatment of chronic myelogenous leukemia and other tumor diseases.In addition to the antitumor effects,imatinib was found to improve hemodynamics and exercise tolerance in patients with severe pulmonary arterial hypertension,but the safety was suboptimal.With the emergence of new formulations of imatinib targeted at the lungs,it is expected to become a new targeted drug for pulmonary arterial hypertension.
6.n-3 polyunsaturated fatty acids ameliorate learning and memory abilities in APPPS1 mice by regulating microglial activation and polarization
Mengyan DENG ; Xiaohui ZHU ; Li HUANG ; Qian BAI ; Weifang LI ; Bin WANG ; Mantian MI
Journal of Army Medical University 2024;46(9):928-939
Objective To construct a model of Fat-1/APPPS1 transgenic mice and a cellular model of microglia and explore the improvement effect and underlying mechanism of n-3 polyunsaturated fatty acids(n-3 PUFAs)on the learning and memory abilities of APPPS1 mice by regulating microglial activation and polarization.Methods After the male mice with heterozygous Fat-1 genotype were mated with the female ones with heterozygous APPPS1 genotype,genetic identification was used to screen the male offspring with Fat-1/APPPS1 genotype.Then after the male wild-type(WT)mice and those with Fat-1,Fat-1/APPPS1,and APPPS1 genotypes were bred until 9 months old,their learning and memory abilities were evaluated with Morris water maze(MWM)test.In addition,gas chromatography-mass spectrometry(GC-MS)was performed to detect the concentration of PUFAs in the brain,and immunohistochemistry(IHC)was applied to detect the deposition of β-amyloid protein(Aβ)in the hippocampal regions.Moreover,immunofluorescence assay,qRT-PCR,and enzyme-linked immunosorbent assays(ELISA)were conducted to measure inflammation,and transcription and expression of Iba-1(indicating the microglial activation)and CD86 and CD206(indicating microglial polarization)in central nervous system(CNS).After pretreated with DHA+EPA(25 pmol/mL∶25 μmol/mL),microglial model of inflammatory injury was established in immortalized mouse BV2 cells induced by LPS(1 μg/mL).Afterwards,immunofluorescence assay,qRT-PCR and Western blotting were used to detect inflammation and microglial activation and polarization.Results Compared with the APPPS1 mice,endogenous n-3 PUFAs effectively improved the learning and memory disorders in Fat-1/APPPS1 ones(P<0.05),remarkably alleviated Aβ deposition in the hippocampal regions(P<0.05),evidently reduced CNS inflammation and microglial activation(P<0.05)and transformed the activated microglia from M1 to M2(P<0.05).Furthermore,BV2 cells with DHA+EPA pretreatment obviously resisted LPS-induced cellular inflammation and induced activated ones from M1 to M2(P<0.05).Conclusion n-3 PUFAs inhibit the microglial activation,regulate the microglial polarization from M1 to M2,reduce CNS inflammation,and thus alleviate learning and memory disorders in APPPS1 mice.
7.Corrective effect of 3D printed scoliosis orthoses
Wenqiang YU ; Yutong HOU ; Chenglan HUANG ; Yunxiao YANG ; Dezhi LU ; Caiping WANG ; Jinwu WANG
Chinese Journal of Rehabilitation Theory and Practice 2023;29(4):390-395
ObjectiveTo investigate the in-brace and short-term correction of 3D-printed scoliosis orthoses. MethodsFrom July to December 2021, 36 patients with adolescent idiopathic scoliosis from Ninth People's Hospital, Shanghai Jiaotong University School of Medicine were selected to complete full-length radiographs of the spine before and immediately after wearing the orthosis. They wore the orthosis more than 20 hours a day, and took radiographs six months later. Cobb angle was calculated. They were assessed with Chinese version of the Scoliosis Research Society's outcomes instrument 22 (SRS-22) before wearing and six months follow-up. ResultsThe mean Cobb angle was (22.10±6.29)° before wearing, and it was (7.85±10.90)° immediately after wearing (t = 4.775, P < 0.01) and (14.33±0.74)° six months follow-up (t = 4.189, P < 0.01). The score of functional status of SRS-22 increased six months follow-up (Z = -2.676, P < 0.01). The Cobb angle immediately after wearing correlated with the Cobb angle six months follow-up (r = 0.826, P < 0.05). Conclusion3D-printed scoliosis orthoses can correct the scoliosis satisfactorily, in-brace and in short-term.
8.3D printed orthopedic insoles for flatfoot: a systematic review
Chenglan HUANG ; Yutong HOU ; Yunxiao YANG ; Hong ZENG ; Ziyan ZHANG ; Wenkuan ZHAO ; Zanbo WANG ; Chunlei SHAN ; Kerong DAI ; Bin CAI ; Jinwu WANG
Chinese Journal of Rehabilitation Theory and Practice 2023;29(4):416-422
ObjectiveTo review the classification of orthopedic insoles, common techniques of 3D printing orthopedic insoles, common materials and their application for flatfoot. MethodsLiteratures were retrieved from PubMed, Web of Science, CNKI and Wanfang Data from 2012 to 2022, and the relevant contents were summarized. ResultsA total of ten studies were finally included, from 5 countries, involving 290 participants, which published from 2019 to 2022. Orthotic insoles were classified as prefabricated, semi-custom, and custom, while custom ones were classified as traditional custom and 3D printed custom. 3D printed orthotic insoles were often made with selective laser sintering, fused deposition modeling (FDM) and PolyJet printing technologies, and commonly used materials included ethylene-vinyl acetate (EVA), polylactic acid, thermoplastic polyurethane, polyamide, and polypropylene. For flatfoot, 3D printed orthotic insoles could improve plantar pressure, relieve foot pain and the combined use of insole posting could control rearfoot valgus. Conclusion3D printed custom insoles can be made more efficiently and accurately than traditional custom insoles. The printing technologies and materials often chosen for 3D printed orthotic insoles are mainly FDM and EVA. 3D printed orthotic insoles is effective on plantar pressure, comfort and foot movement function of flatfoot.
9.Eligibility of C-BIOPRED severe asthma cohort for type-2 biologic therapies.
Zhenan DENG ; Meiling JIN ; Changxing OU ; Wei JIANG ; Jianping ZHAO ; Xiaoxia LIU ; Shenghua SUN ; Huaping TANG ; Bei HE ; Shaoxi CAI ; Ping CHEN ; Penghui WU ; Yujing LIU ; Jian KANG ; Yunhui ZHANG ; Mao HUANG ; Jinfu XU ; Kewu HUANG ; Qiang LI ; Xiangyan ZHANG ; Xiuhua FU ; Changzheng WANG ; Huahao SHEN ; Lei ZHU ; Guochao SHI ; Zhongmin QIU ; Zhongguang WEN ; Xiaoyang WEI ; Wei GU ; Chunhua WEI ; Guangfa WANG ; Ping CHEN ; Lixin XIE ; Jiangtao LIN ; Yuling TANG ; Zhihai HAN ; Kian Fan CHUNG ; Qingling ZHANG ; Nanshan ZHONG
Chinese Medical Journal 2023;136(2):230-232

Result Analysis
Print
Save
E-mail