1.Experience of Using Charcoal-Processed Traditional Chinese Medicine in the Treatment of Gynecological Hemorrhagic Disorders
Xiaolan WU ; Zhaoling YOU ; Guiyun WANG ; Kailing WANG ; Xiaojuan YE ; Lingyu LIAO ; Yueheng LI ; Huiping LIU
Journal of Traditional Chinese Medicine 2025;66(3):308-311
Charcoal-processed traditional Chinese herbal medicine has various therapeutic effects, including astringing, hemostasis, anti-diarrhea, clearing heat, tonifying, and warming the interior. This paper summarizes the clinical application features, compatible experiences, dosages, and precautions for over 20 types of charcoal-processed herbal medicine in the treatment of gynecological bleeding disorders caused by dysfunctions such as dysfunctional uterine bleeding, endometriosis, uterine incision pseudocavity, and vaginal bleeding resulting from threatened miscarriage. The charcoal-processed herbal medicine include Huangqin (Scutellaria Baicalensis) Charcoal, Dahuang (Rheum Palmatum) Charcoal, Cebai (Platycladus Orientalis) Charcoal, Diyu (Sanguisorba Officinalis) Charcoal, Daji (Cirsium Setosum) Charcoal, Xiaoji (Cirsium Japonicum) Charcoal, Shengdi (Rehmannia Glutinosa) Charcoal, Aiye (Artemisia Argyi) Charcoal, Paojiang (Zingiber Officinale) Charcoal, Xuduan (Dipsacus Asper) Charcoal, Duzhong (Eucommia Ulmoides) Charcoal, Qiancao (Rubia Cordifolia) Charcoal, Puhuang (Typha Angustifolia) Charcoal, Shanzha (Crataegus Pinnatifida) Charcoal, Jingjie (Schizonepeta Tenuifolia) Charcoal, Xueyu (Carthamus Tinctorius) Charcoal, Zonglyu (Areca Catechu) Charcoal, Wumei (Prunus Mume) Charcoal, Shudahuang (Rheum Officinale) Charcoal, Lianfang (Nymphaea Alba) Charcoal, Mianmaguanzhong (Clematis Armandii) Charcoal, and Oujie (Nelumbo Nucifera) Charcoal.
2.Research on the innovation of medical humanities teaching in military medical universities by the red doctor spirit
Qiuju ZHANG ; Taishi ZHOU ; Yan WU ; Xiaojuan WU ; Yang JIAO ; Zhenghao LI
Chinese Medical Ethics 2025;38(7):909-913
The red doctor spirit is the advanced culture of the Communist Party of China formed under a specific historical and cultural background. It can be summarized as “political firmness, excellent technology, working hard, and healing the wounded and rescuing the dying.” This content has many hidden similarities and integrations with the goal of cultivating humanistic literacy for medical students in military medical universities. This paper aimed to identify the important connection points between the red doctor spirit and the contents and goals of medical humanities teaching, as well as integrate the red doctor spirit into medical humanities teaching by various dimensions, including systematic reconstruction of textbook content, immersive innovation in teaching form, three-dimensional support in resource construction, and innovative implementation of narrative medicine teaching. It also further explored the extension of the red doctor spirit in military medical humanistic literacy, namely, revolutionary humanism and revolutionary heroism, thereby enhancing the effectiveness of medical humanistic teaching.
3.Drug resistance gene variation of HIV-1 strains in Huzhou City, Zhejiang Province
Xiaojuan ZHU ; Zhonghao LU ; Yunfeng ZHA ; Xiaofang WU ; Xiaohua ZHU
Shanghai Journal of Preventive Medicine 2025;37(6):540-544
ObjectiveTo investigate the variation of drug resistance genes in human immunodeficiency virus (HIV)-1 strains in Huzhou City, Zhejiang Province, so as to provide a basis for guiding the adjustment of treatment plans for ADIS patients or patients infected with HIV. MethodsA total of 555 samples were
4.Effectss of persistent obesity on lung function in school age children
Chinese Journal of School Health 2024;45(4):549-553
Objective:
To analyze the impact of persistent obesity on their lung function, so as to offer insights for implementing intervention measures to increase lung function in obese school age children.
Methods:
A total of 335 children from the Sheyang Mini Birth Cohort established in 2009 in Yancheng City, Jiangsu Province, who participated in the follow up at the ages of 7 years (2016) and 10 years (2019), were selected as the study participants. Physical measurements including height, weight, and lung function were recorded. According to the World Health Organization standard, that is, gender and age specific to correct the body mass index to calculate the body mass index Z score, was used to evaluate the obesity status of children at the age of 7 and 10. Children were divided into four groups, including sustained non obesity group, restored obesity group, newly classified obesity group, and persistent obesity group. Meanwhile, the lung function prediction equations recommended by the Global Lung Function Initiative were used to standardize the lung function indexes of children. Pulmonary function differences among these groups were examined, and the relationship between childhood obesity and pulmonary function was longitudinally analyzed using generalized estimating equations.
Results:
The prevalence of obesity were 9.0% and 16.1% at the age of 7 and 10 years, respectively. The proportion of both newly classified and persistent obesity group were 8.1%, respectively. The forced expiratory volume in one second (FEV 1) and forced vital capacity (FVC) were (1 269.90±202.70) and (1 415.70±230.00) mL, respectively, at the age of 7 years. FEV 1 and FVC at the age of 10 years were (1 440.80±403.20) and (1 555.60±517.60) mL, respectively. Cross sectional analysis at age 7 showed that forced expiratory flow at 75% vital capacity (FEF 75 ) ( β=-0.52, 95%CI =-0.96--0.07) and maximal mid expiratary flow (MMEF) ( β=-0.45, 95%CI =-0.89--0.00) were significantly lower in obese children compared to their non obese peers ( P < 0.05). Longitudinal analysis indicated that obese children had lower levels of lung pulmonary function, with a statistically significant difference in FEV 1 ( β=-0.44, 95%CI=-0.85--0.02, P <0.05). There was no significant difference among the various obesity groups ( P >0.05), while gender stratified results revealed significant reductions in FEV 1/FVC in newly classified obese girls at age 10 years ( β=-1.76, 95%CI =-3.13--0.38) and in MMEF in persistently obese girls at age 10 years ( β=-1.44, 95%CI = -2.79- -0.09) ( P <0.05).
Conclusion
Obesity may contribute to reduced lung function levels in school aged children, with newly classified and persistent obesity having more pronounced effects on lung function in girls.
5.Screening of stable amoxicillin resistant clones of Helicobacter pylori and detection of its gene mutations
Qiudan Lu ; Mengheng Mi ; Guzhen Cui ; Zhengrong Zhang ; Xiaojuan Wu ; Zhenghon Chen
Acta Universitatis Medicinalis Anhui 2024;59(1):39-44
Objective :
To investigate the phenotype of amoxicillin ( AMX) unstable resistant Helicobacter pylori (Hp) evolving into AMX stable high level resistance and the detection of its mutated genes.
Methods :
Using the frozen Hp strain H390 as the starting strain,the clones resistant to AMX were continuously cultured on the medium with increasing AMX concentration,and the minimum inhibitory concentration ( MIC) of the resistant clones was detected.After frozen at -80 ℃ for 3 months,the drug resistance was stable according to whether the MIC de- creased after frozen storage. Genome sequencing analysis and efflux pump inhibition assay were performed on cloned H390r and parental strain H390 with the highest AMX MIC value,and gene mutations associated with the high level AMX resistance obtained by H390r were detected and identified.
Results :
Four AMX high level resistant clones were obtained by AMX screening with MICs of 12,32,64 and ≥ 256 mg / L ,respectively,and none of the MICs were altered after freezing at -80 ℃ . Compared to the parental strain H390,the AMX stable resistant clone H390r had mutations in several genes,including hefC encoding the RND efflux system,hopB and hopC encoding the pore proteins and ftsI encoding the penicillin binding protein ,which were associated with AMX resistance. H390r was substantially reduced in MIC to AMX in the presence of efflux pump inhibitors.
Conclusion
AMX can screen stable resistant clones from unstable resistant Hp.H390r had mutations in hefC,hopB,hopC,and ftsI asso- ciated with AMX resistance.These mutations may be the main reason why H390r acquired a stable high level of re- sistance to AMX.
6.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
7.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
8.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
9.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
10.Establishment of a noninvasive predictive model for antiviral therapy in patients with chronic hepatitis B virus infection and an age of≤30 years
Changxiang LAI ; Qingrong TANG ; Xiulian ZHANG ; Qiyuan TANG ; Zhiyu LI ; Xuan ZHOU ; Wenjie XIAN ; Ruikun CHEN ; Xiaojuan WU ; Fang WANG
Journal of Clinical Hepatology 2024;40(7):1328-1333
Objective To predict whether antiviral therapy is required in patients with chronic hepatitis B virus(HBV)infection and an age of≤30 years by establishing a noninvasive model,and to investigate the diagnostic value of this model.Methods A retrospective analysis was performed for the clinical data of 175 patients with chronic HBV infection who were admitted to Shenzhen Third People's Hospital from January 2017 to January 2023 and met the inclusion criteria,and according to the results of liver biopsy,they were divided into treatment group with 41 patients(with indications for antiviral therapy)and observation group with 134 patients(without indications for antiviral therapy).The two groups were analyzed in terms of the indicators including clinical data,imaging examinations,and serum biochemical parameters.The univariate and multivariate Logistic regression analyses were used to investigate the parameters affecting the indication for antiviral therapy,and different models for predicting the need for antiviral therapy were constructed based on related parameters.The receiver operating characteristic(ROC)curve was used to compare the diagnostic value of different models.The independent-samples t test was used for comparison of normally distributed continuous variables between groups,and the Mann-Whitney U rank sum test was used for comparison of non-normally distributed continuous variables between groups;the chi-square test or the Fisher's exact test was used for comparison of categorical data between groups.Results There were significant differences between the treatment group and the observation group in alanine aminotransferase,ferritin,total cholesterol(CHOL),triglyceride,platelet count,liver stiffness measured by sound touch elastography(STE),and procollagen Ⅲ N-terminal propeptide(PIIIP)(all P<0.05).The multivariate Logistic regression analysis showed that CHOL(odds ratio[OR]=0.4,95%confidence interval[CI]:0.2—1.0),STE(OR=1.5,95%CI:1.0—2.1),and PIIIP(OR=1.1,95%CI:1.0—1.1)were independent predictive factors for the indications for antiviral therapy.Model 1(STE+PIIIP+CHOL),model 2(STE+PIIIP),model 3(STE+CHOL),model 4(PIIIP+CHOL)had an area under the ROC curve of 0.908,0.848,0.725,and 0.725,respectively,while STE,PIIIP,and CHOL used alone had an AUC of 0.836,0.725,and 0.634,respectively,suggesting that model 1 had the largest AUC,with a specificity of 77.34%and a sensitivity of 96.36%,and had a significant difference compared with STE,PIIIP,CHOL,and the models 2,3,and 4(Z=0.21,3.08,3.06,3.23,0.89,and 0.88,all P<0.05).Conclusion The noninvasive model established based on CHOL,STE,and PIIIP has a good value in predicting the need for antiviral therapy in patients with chronic HBV infection and an age of≤30 years.


Result Analysis
Print
Save
E-mail