1.Low-Cost Phantom Model for Simulation Training in Ultrasound-Guided Ethanol Ablation of a Cystic Thyroid Nodule.
Darryl Young S DUGUIL ; Raphael S ROJAS ; Maria Karen A CAPUZ
Philippine Journal of Otolaryngology Head and Neck Surgery 2025;40(1):37-41
Objective:To describe a low-cost, reproducible phantom model for training medical practitioners in ultrasound-guided ethanol ablation (EA) of a cystic thyroid nodule.
Methods:The model of cyst contents was created using a mixture of coffee powder, cornstarch and water to mimic colloidal contents. This was injected into the finger of a cut surgical glove secured with transparent tape to serve as an inflatable capsule and placed inside a chicken breast. This setup allows practitioners to perform key ultrasound-guided ethanol ablation techniques including spinal needle insertion, cyst aspiration, saline flushing, re-aspiration and ethanol injection.
Results:The phantom model was assembled for PhP 150.30 per unit and took approximately 5 minutes to construct. This model was demonstrated to be a cost-effective and simple method for enabling specialists to practice and enhance their skills in ultrasound-guided ethanol ablation of a cystic thyroid nodule.
Conclusion:The described phantom model provides an accessible and practical training tool for healthcare providers to gain proficiency in ultrasound-guided ethanol ablation of a cystic thyroid nodule in a safe and controlled setting prior to actual patient handling.
Medical Education ; Otorhinolaryngology ; Radiology ; Ultrasonography
2.A prospective study of super-thin anterolateral thigh flap harvesting assisted by high-frequency color Doppler ultrasound in detecting perforators in deep adipose layers.
Qianyuan LIU ; Jiandong ZHOU ; Wencheng WANG ; Xueming CHEN ; Yajun XU ; Hai HUANG ; Jingyi MI
Chinese Journal of Reparative and Reconstructive Surgery 2024;38(1):62-68
OBJECTIVE:
To investigate the clinical application of high-frequency color Doppler ultrasound (HFCDU) in detecting perforators in the deep adipose layers for harvesting super-thin anterolateral thigh flap (ALTF).
METHODS:
Between August 2019 and January 2023, 45 patients (46 sides) with skin and soft tissue defects in the foot and ankle were treated, including 29 males and 16 females, aged from 22 to 62 years, with an average of 46.7 years. The body mass index ranged from 19.6 to 36.2 kg/m 2, with an average of 23.62 kg/m 2. The causes of injury included traffic accident injury in 15 cases, heavy object crush injury in 20 cases, mechanical injury in 8 cases, heat crush injury in 1 case, and chronic infection in 1 case. There were 20 cases on the left side, 24 cases on the right side, and 1 case on both sides. After thorough debridement, the wound size ranged from 5 cm×4 cm to 17 cm×11 cm. All patients underwent free super-thin ALTF transplantation repair. HFCDU was used to detect the location of the perforators piercing the deep and superficial fascia, as well as the direction and branches of the perforators within the deep adipose layers before operation. According to the preoperative HFCDU findings, the dimensions of the super-thin ALTF ranged from 6 cm×4 cm to 18 cm×12 cm. The donor sites of the flaps were directly sutured.
RESULTS:
A total of 55 perforators were detected by HFCDU before operation, but 1 was not found during operation. During operation, a total of 56 perforators were found, and 2 perforators were not detected by HFCDU. The positive predictive value of HFCDU for identifying perforator vessels was 98.2%, and the sensitivity was 96.4%. Among the 54 perforators accurately located by HFCDU, the orientation of the perforators in the deep adipose layers was confirmed during operation. There were 21 perforators (38.9%) traveled laterally and inferiorly, 12 (22.2%) traveled medially and inferiorly, 14 (25.9%) traveled laterally and superiorly, 5 (9.3%) traveled medially and superiorly, and 2 (3.7%) ran almost vertically to the body surface. Among the 54 perforators accurately located by HFCDU, 35 were identified as type 1 perforators and 12 as type 2 perforators (HFCDU misidentified 7 type 2 perforators as type 1 perforators). The sensitivity of HFCDU in identifying type 1 perforators was 100%, with a positive predictive value of 83.3%. For type 2 perforators, the sensitivity was 63.2%, and the positive predictive value was 100%. The surgeries were successfully completed. The super-thin ALTF had a thickness ranging from 2 to 6 mm, with an average of 3.56 mm. All super-thin ALTF survived, however, 1 flap experienced a venous crisis at 1 day after operation, but it survived after emergency exploration and re-anastomosis of the veins; 1 flap developed venous crisis at 3 days after operation but survived after bleeding with several small incisions; 3 flaps had necrosis at the distal edge of the epidermis, which healed after undergoing dressing changes. All 45 patients were followed up 6-18 months (mean, 13.6 months). Three flaps required secondary defatting procedures, while the rest had the appropriate thickness, and the overall appearance was satisfactory.
CONCLUSION
Preoperative application of HFCDU to detect the perforator in the deep adipose layers can improve the success and safety of the procedure by facilitating the harvest of super-thin ALTF.
Male
;
Female
;
Humans
;
Thigh/surgery*
;
Plastic Surgery Procedures
;
Prospective Studies
;
Skin Transplantation
;
Free Tissue Flaps
;
Burns
;
Soft Tissue Injuries/surgery*
;
Ultrasonography, Doppler, Color
;
Crush Injuries/surgery*
;
Perforator Flap
;
Treatment Outcome
3.Noninvasive Diagnostic Technique for Nonalcoholic Fatty Liver Disease Based on Features of Tongue Images.
Rong-Rui WANG ; Jia-Liang CHEN ; Shao-Jie DUAN ; Ying-Xi LU ; Ping CHEN ; Yuan-Chen ZHOU ; Shu-Kun YAO
Chinese journal of integrative medicine 2024;30(3):203-212
OBJECTIVE:
To investigate a new noninvasive diagnostic model for nonalcoholic fatty liver disease (NAFLD) based on features of tongue images.
METHODS:
Healthy controls and volunteers confirmed to have NAFLD by liver ultrasound were recruited from China-Japan Friendship Hospital between September 2018 and May 2019, then the anthropometric indexes and sampled tongue images were measured. The tongue images were labeled by features, based on a brief protocol, without knowing any other clinical data, after a series of corrections and data cleaning. The algorithm was trained on images using labels and several anthropometric indexes for inputs, utilizing machine learning technology. Finally, a logistic regression algorithm and a decision tree model were constructed as 2 diagnostic models for NAFLD.
RESULTS:
A total of 720 subjects were enrolled in this study, including 432 patients with NAFLD and 288 healthy volunteers. Of them, 482 were randomly allocated into the training set and 238 into the validation set. The diagnostic model based on logistic regression exhibited excellent performance: in validation set, it achieved an accuracy of 86.98%, sensitivity of 91.43%, and specificity of 80.61%; with an area under the curve (AUC) of 0.93 [95% confidence interval (CI) 0.68-0.98]. The decision tree model achieved an accuracy of 81.09%, sensitivity of 91.43%, and specificity of 66.33%; with an AUC of 0.89 (95% CI 0.66-0.92) in validation set.
CONCLUSIONS
The features of tongue images were associated with NAFLD. Both the 2 diagnostic models, which would be convenient, noninvasive, lightweight, rapid, and inexpensive technical references for early screening, can accurately distinguish NAFLD and are worth further study.
Humans
;
Non-alcoholic Fatty Liver Disease/diagnostic imaging*
;
Ultrasonography
;
Anthropometry
;
Algorithms
;
China
4.Diagnostic value of ACR TI-RADS combined with three-dimensional shear wave elastography in ACR TI-RADS 4 and 5 thyroid nodules.
Lijun HAO ; Peiqing LIU ; Changwei DING ; Jing LI ; Yingchun ZHANG
Chinese Medical Journal 2023;136(10):1225-1230
BACKGROUND:
Three-dimensional shear wave elastography (3D-SWE) is a promising method in distinguishing benign and malignant thyroid nodules. By combining with conventional method, it may further improve the diagnostic value. The study aimed to assess the diagnostic value of American College of Radiology (ACR) thyroid imaging reporting and data system (TI-RADS) combined with 3D-SWE in ACR TI-RADS 4 and 5 thyroid nodules.
METHODS:
All nodules were examined by conventional ultrasonography, ACR TI-RADS classification, and 3D-SWE examination. Conventional ultrasonography was used to observe the location, size, shape, margin, echogenicity, taller-than-wide sign, microcalcification, and blood flow of thyroid nodules, and then ACR TI-RADS classification was performed. The Young's modulus values (3D-C-Emax, 3D-C-Emean, and elastography standard deviation [3D-C-Esd]) were measured on the reconstructed coronal plane images. According to the receiver operating characteristic (ROC) curve, the best diagnostic efficiency among 3D-C-Emax, 3D-C-Emean, and 3D-C-Esd was selected and the cut-off threshold was calculated. According to the surgical pathology, they were divided into benign group and malignant group. And appropriate statistical methods such as t -test and Mann-Whitney U test were used to compare the difference between the two groups. On this basis, 3D-SWE combined with conventional ACR TI-RADS was reclassified as combined ACR TI-RADS to determine benign or malignant thyroid nodules.
RESULTS:
Of the 112 thyroid nodules, 62 were malignant and 50 were benign. The optimal cut-off value of three-dimensional maximum Young's modulus in coronal plane (3D-C-Emax) was 51.5 kPa and the area under the curve (AUC) was 0.798. The AUC, sensitivity, specificity, and accuracy of conventional ACR TI-RADS were 0.828, 83.9%, 66.0%, and 75.9%, respectively. The AUC, sensitivity, specificity, and accuracy of combined ACR TI-RADS were 0.845, 90.3%, 66.0%, and 79.5%, respectively. The difference between the two AUC values was statistically significant.
CONCLUSIONS
Combined ACR TI-RADS has higher diagnostic efficiency than conventional ACR TI-RADS. The sensitivity and accuracy of combined ACR TI-RADS showed significant improvements. It can be used as an effective method in the diagnosis of thyroid nodules.
Humans
;
Thyroid Nodule/pathology*
;
Elasticity Imaging Techniques/methods*
;
Retrospective Studies
;
Ultrasonography/methods*
5.Advances in Molecular Targeted Ultrasound Contrast Agents.
Zhen YANG ; Ming-Bo ZHANG ; Yu-Kun LUO
Acta Academiae Medicinae Sinicae 2023;45(2):298-302
In real-time ultrasound,molecular targeted contrast agent is introduced into the blood circulation through peripheral intravenous injection to enhance the imaging signal of target lesions after binding to the corresponding intravascular receptors,which can realize early diagnosis,staging of diseases,assessment of treatment response,and targeted treatment.In addition,molecular targeted ultrasound contrast agents provide a platform for the delivery of drugs and genes via microbubbles,and nanoscale contrast agents can be infiltrated through vascular endothelium into the interstitial space of the lesion for imaging or treatment.The available studies of molecular targeted ultrasound contrast agents mainly focus on the preclinical trials.Some clinical trials have been conducted in humans and preliminarily confirm the safety and feasibility of targeted ultrasound contrast agents.The molecular targeted ultrasound contrast agents enjoy a broad prospect in clinical application.
Humans
;
Contrast Media/chemistry*
;
Molecular Targeted Therapy
;
Ultrasonography/methods*
;
Diagnostic Imaging
6.Evaluation of Extrathyroidal Extension of Papillary Thyroid Microcarcinoma With Three-Dimensional Tomographic Ultrasound Imaging.
Ru-Yu LIU ; Yu-Xin JIANG ; Rui-Na ZHAO ; Xing-Jian LAI ; Chuan-Ying-Zi LU ; Lu-Ying GAO ; Ying WANG ; Xue-Hua XI ; Bo ZHANG
Acta Academiae Medicinae Sinicae 2023;45(3):361-365
Objective To evaluate extrathyroidal extension (ETE) in papillary thyroid microcarcinoma (PTMC) with three-dimensional tomographic ultrasound imaging (3D-TUI). Methods A total of 97 thyroid nodules of 79 patients with PTMC treated in PUMC Hospital from February 2016 to January 2018 were included in this study.Two ultrasound experts performed independent blinded assessment of the relationship between thyroid nodules and thyroid capsule by two-dimensional ultrasound (2D-US) and 3D-TUI.The results of 2D-US and 3D-TUI in evaluating ETE were compared with intraoperative findings and postoperative histological and pathological results. Results Among the 97 nodules,54 (55.7%) nodules had ETE.The diagnostic sensitivity (68.5% vs.37.0%;χ2=10.737,P=0.002),accuracy (74.5% vs.56.7%;χ2=6.686,P=0.015),and area under the receiver operating characteristic curve[0.761 (95%CI=0.677-0.845) vs.0.592 (95%CI=0.504-0.680);Z=3.500,P<0.001] of 3D-TUI were higher than those of 2D-US.However,3D-TUI and 2D-US showed no significant difference in the specificity (84.1% vs.81.4%;χ2=0.081,P=0.776),negative predictive value (67.9% vs.50.7%;χ2=3.645,P=0.066),or positive predictive value (84.1% vs.71.4%;χ2=1.663,P=0.240). Conclusion Compared with 2D-US,3D-TUI demonstrates increased diagnostic efficiency for ETE of PTMC.
Humans
;
Thyroid Nodule
;
Thyroid Neoplasms/diagnosis*
;
Carcinoma, Papillary/pathology*
;
Ultrasonography/methods*
;
Retrospective Studies
7.Influencing Factors and Prediction Model of Performance of Needle Visualization in Fine Needle Aspiration of Thyroid Nodules.
Liang-Kai WANG ; Jia-Jia TANG ; Wen-Quan NIU ; Xin-Ying JIA ; Xue-Hua XI ; Jiao-Jiao MA ; Hui-Lin LI ; Zhe SUN ; Xin-Yi LIU ; Bo ZHANG
Acta Academiae Medicinae Sinicae 2023;45(3):366-373
Objective To investigate the influencing factors and establish a model predicting the performance of needle visualization in fine-needle aspiration (FNA) of thyroid nodules. Methods This study prospectively included 175 patients who underwent FNA of thyroid nodules in the Department of Ultrasound in China-Japan Friendship Hospital and compared the display of the needle tips in the examination of 199 thyroid nodules before and after the application of needle visualization.We recorded the location,the positional relationship with thyroid capsule,ultrasonic characteristics,and the distribution of the soft tissue strip structure at the puncture site of the nodules with unclear needle tips display before using needle visualization.Furthermore,according to the thyroid imaging reporting and data system proposed by the American College of Radiology,we graded the risk of the nodules.Lasso-Logistic regression was employed to screen out the factors influencing the performance of needle visualization and establish a nomogram for prediction. Results The needle tips were not clearly displayed in the examination of 135 (67.8%) and 53 (26.6%) nodules before and after the application of needle visualization,respectively,which showed a significant difference (P<0.001).Based on the positional relationship between the nodule and capsule,anteroposterior/transverse diameter (A/T) ratio,blood supply,and the distribution of subcutaneous strip structure at the puncture site,a nomogram was established to predict the probability of unclear display of the needle tips after application of needle visualization.The C-index of the prediction model was 0.75 (95%CI=0.67-0.84) and the area under the receiver operating characteristic curve was 0.72.The calibration curve confirmed the appreciable reliability of the prediction model,with the C-index of 0.70 in internal validation. Conclusions Needle visualization can improve the display of the needle tip in ultrasound-guided FNA of thyroid nodules.The nomogram established based on ultrasound features such as the positional relationship between the nodule and capsule,A/T ratio,blood supply,and the distribution of subcutaneous strip structure at the puncture site can predict whether needle visualization is suitable for the examination of nodules.
Humans
;
Thyroid Nodule/diagnostic imaging*
;
Biopsy, Fine-Needle/methods*
;
Reproducibility of Results
;
Ultrasonography
;
Retrospective Studies
;
Thyroid Neoplasms
8.Value of High-Frequency Ultrasound in the Diagnosis of Pronator Teres Syndrome.
Min HU ; Shi-Yu CHEN ; Xiao-Long YANG ; Tian-Fang LIN ; Jie-Feng WANG ; Zheng-Hua ZANG
Acta Academiae Medicinae Sinicae 2023;45(3):436-439
Objective To investigate the clinical value of high-frequency ultrasound in the diagnosis of pronator teres syndrome (PTS). Methods The high-frequency ultrasound was employed to examine and measure the median nerve of the pronator teres muscle in 30 patients with PTS and 30 healthy volunteers (control group).The long-axis diameter (LA),short-axis diameter (SA) and cross-sectional area (CSA) of the median nerve were measured.The receiver operating characteristic curve of the median nerve ultrasonic measurement results was established,and the area under the curve (AUC) was calculated.The diagnostic efficiency of each index for PTS was compared with the surgical results as a reference. Results The PTS group showed larger LA[(5.02±0.50) mm vs.(3.89±0.41) mm;t=4.38,P=0.013],SA[(2.55±0.46) mm vs.(1.70±0.41) mm;t=5.19,P=0.009],and CSA[(11.13±3.72) mm2 vs.(6.88±2.68) mm2;t=8.42,P=0.008] of the median nerve than the control group.The AUC of CSA,SA,and LA was 94.3% (95%CI=0.912-0.972,Z=3.586,P=0.001),77.7% (95%CI=0.734-0.815,Z=2.855, P=0.006),and 78.8% (95%CI=0.752-0.821,Z=3.091,P=0.004),respectively.With 8.63 mm2 as the cutoff value,the sensitivity and specificity of CSA in diagnosing PTS were 93.3% and 90.0%,respectively. Conclusion High-frequency ultrasound is a practical method for diagnosing PTS,and the CSA of median nerve has a high diagnostic value.
Humans
;
Forearm/innervation*
;
Muscle, Skeletal/innervation*
;
Median Nerve/diagnostic imaging*
;
Ultrasonography/methods*
;
Sensitivity and Specificity
9.Multiresolution discrete optimization registration method of ultrasound and magnetic resonance images based on key points.
Journal of Biomedical Engineering 2023;40(2):202-207
The registration of preoperative magnetic resonance (MR) images and intraoperative ultrasound (US) images is very important in the planning of brain tumor surgery and during surgery. Considering that the two-modality images have different intensity range and resolution, and the US images are degraded by lots of speckle noises, a self-similarity context (SSC) descriptor based on local neighborhood information was adopted to define the similarity measure. The ultrasound images were considered as the reference, the corners were extracted as the key points using three-dimensional differential operators, and the dense displacement sampling discrete optimization algorithm was adopted for registration. The whole registration process was divided into two stages including the affine registration and the elastic registration. In the affine registration stage, the image was decomposed using multi-resolution scheme, and in the elastic registration stage, the displacement vectors of key points were regularized using the minimum convolution and mean field reasoning strategies. The registration experiment was performed on the preoperative MR images and intraoperative US images of 22 patients. The overall error after affine registration was (1.57 ± 0.30) mm, and the average computation time of each pair of images was only 1.36 s; while the overall error after elastic registration was further reduced to (1.40 ± 0.28) mm, and the average registration time was 1.53 s. The experimental results show that the proposed method has prominent registration accuracy and high computational efficiency.
Humans
;
Imaging, Three-Dimensional/methods*
;
Magnetic Resonance Imaging/methods*
;
Ultrasonography/methods*
;
Algorithms
;
Surgery, Computer-Assisted/methods*
10.Comparison of results of prenatal diagnosis by different techniques for fetuses with increased nuchal translucency.
Wencheng DAI ; Xinhong LIU ; Xiaorong MA ; Zhen YU ; Huijun LI
Chinese Journal of Medical Genetics 2023;40(5):532-537
OBJECTIVE:
To assess the value of chromosomal microarray analysis (CMA) and trio-whole exome sequencing (trio-WES) for fetuses with increased nuchal translucency (NT) thickness.
METHODS:
Sixty two pregnant women who had visited Urumqi Maternal and Child Care Health Hospital between June 2018 and June 2020 for NT ≥ 3.0 mm at 11 ~ 13+6 gestational weeks were selected as study subjects. Relevant clinical data were collected. The patients were divided into 3.0 ~ <3.5 mm (n = 33) and ≥3.5 mm groups (n = 29). Chromosome karyotyping analysis and chromosomal microarray analysis were carried out. And trio-WES analysis was performed on 15 samples with NT thickening but negative CMA results. The distribution and incidence of chromosomal abnormalities in the two groups were compared by using chi-square test.
RESULTS:
The median age of the pregnant women was 29 years old (22 ~ 41 years old), the median thickness of NT was 3.4 mm (3.0 ~ 9.1 mm), and the median gestational age at the detection was 13+4 weeks (11+5 ~ 13+6 weeks). Chromosome karyotyping analysis has detected 12 cases of aneuploidies and 1 case of derivative chromosome. The detection rate was 20.97% (13/62). CMA has detected 12 cases of aneuploidies, 1 case of pathogenic CNV and 5 cases of variant of uncertain significance (VUS), with a detection rate of 29.03% (18/62). The aneuploidy rate for the NT ≥ 3.5 mm group was higher than that for the 3.0 ≤ NT < 3.5 mm group [3.03% (1/33) vs. 41.38% (12/29), χ² = 13.698, P < 0.001]. There was no statistically significant difference between the two groups in the detection rate of fetal pathogenic CNV and VUS (χ² = 0.028, P > 0.05). Trio-WES analysis of 15 samples with negative CMA result and no structural abnormality has identified 6 heterozygous variants, including SOS1: c.3542C>T (p.A1181V) and c.3817C>G (p.L1273V), COL2A1: c.436C>T (p.P146S) and c.3700G>A (p.D1234N), LZTR1: c.1496T>C (p.V499A), and BRAF: c.64G>A (p.D22N), respectively. Based on the guidelines from the American College of Medical Genetics and Genomics (ACMG), all of the variants were rated as VUS.
CONCLUSION
NT thickening can indicate chromosome abnormality, and CMA and trio-WES may be used for the prenatal diagnosis.
Pregnancy
;
Humans
;
Female
;
Adult
;
Infant
;
Nuchal Translucency Measurement/methods*
;
Prenatal Diagnosis/methods*
;
Chromosome Aberrations
;
Aneuploidy
;
Fetus/diagnostic imaging*
;
Ultrasonography, Prenatal
;
DNA Copy Number Variations
;
Transcription Factors


Result Analysis
Print
Save
E-mail